Have a look at the manual Toshiba Strata E Electronic Key Telephone System Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
3 I HATAS,/& GENERAL DESCRIPTION AUGUST 1989 FIGURE 9-W-button ELECTRONIC TELEPHONE FIGURE Xl-ZO-button ELECTRONIC TELEPHONE 0 CO Line Identification l Speed Dial Memo l Timed Reminders System software allows the customer to assign feature buttons on all electronic telephones in a completely flexible manner. Electronic Telephone Upgrade Options: All elec- tronic telephones may be upgraded with Off- hook Call Announce. Loud Ringing Bell and Headset capability. l Off-hook Call Announce Upgrade: Each electronic telephone may be upgraded to receive intercom calls when the handset is off-hook by installing an Off-hook Call An- nounce upgrade assembly. FIGURE 1 I-20-button LIQUID CRYSTAL DISPLAY ELECTRONIC TELEPHONE NOTE: On/y those telephones programmed to re- ceive OCA announcements need the OCA upgrade. 4 The assembly consists of two PCBs, the HVSU and the HVSI, which install inside the telephone base with plug-in connectors. l Loud Ringing Bell/Headset Upgrade: Each electronic telephone may also be upgraded to provide a loud ringing bell interface and a modular headset interface. To accomplish this. an upgrade assembly consisting of a small PCB (HHEU) installs on the main PCB. inside the telephone. with a plug-in connec- tor. An External Speaker (HESB) is directly con- nected to the upgraded phone. When the phone rings, the HESB sounds a loud tone that mimics the phone’s ring. See Peripheral Equipment.* Most standard headsets plug into the HHEU jack and are compatible with the electronic tele- phone. An electronic telephone may use all available upgrade options simultaneously. For example, the same station may be upgraded with OCA, a Loud Ringing Bell and a headset. .s -- -4-
More Electronic Telephone Standard Features: All electronic telephones may be wall mounted without additional equipment. They are also hearing aid-compatible. Each electronic telephone also features a stan- dard modular handset cord, and is connected to the system with a 2-pair modular line cord. Various upgrade options, such as the Off-hook Call An- nounce and Loud Ringing Bell upgrade assem- blies, require the telephone to be connected to the system with special wiring. (A 3-pair modular line cord is required for Off-hook Call Announce, and a custom external speaker cable is required for the Loud Ringing Bell.) 3 ELECTRICAL CHARACTERISTICS General The key service unit operates from an internal power supply: which connects to a standard 3- wire. 117 VAC. 60-Hz. grounded wall outlet. Loss of AC power will cause operational failure of the system. System memory, however. is pro- tected from loss due to power failure with a memory backup battery. ‘Full system reserve power is available as an option. NOTE: The memory backup battery is designed to maintain full memory protection for approx- imatelyone year with no externalpowersource applied. STRATAS,/VI, GENERAL DESCRIPTION AUGUST1989 4 FEATURES and SERVICES The features and services of these electronic key telephone systems are summarized in Tables’ B and C, which list the standard and optional features, respectively. The electrical characteristics of the system are summarized in Table A. -5-
alnHlAJe/Vle GENERALDESCRIPTION AUGUST1989 TABLEA SUMMARYOFELECTRICALCHARACTERISTICS Loop Limits Station Door Phone Control Unit (HDCB)-to-KSU Door Phone/Monitor Station-to-HDCB HOXB-to-Station HOLB-, HSMB-, HCNB-, HOXB-to-KSU HIOB-to-KSU HIOB-to-Peripheral Ringing Tones CO Line (idle station) CC Line (busy station) HIOB Station (Intercom) HIOB Station (CO call) Intercom Line Door Phone A & C Tones Door Phone B Tone Busy Override Tone Dial Tone (intercom) Ringback Tone Busy Tone Do Not Disturb Tone Voice Page Warning Tone Off-hook Call Announce Warning Tone Executive Override Warning Tone Hold Recall Tone Dialing Primary Power HPSU 6120 (Se) HPSU 7120 (VI,) Environmental Specifications Operating Temperature Operating Humidity 1,000’ (305 M), 24 AWG cable, 2 pair,(3-pair wit OCA) 1,000’ (305 M), 24 AWG cable, 2 pair 1 .OOO’ (305 M), 24 AWG cable, 1 -pair 500 ohms (including telephone), 48*VDC, l-pair 17’ (5.2 M), 24 AWG cable, number of pair as required 650’ (200 M), 24 AWG cable, 2-pair 300 R maximum, including peripheral resistance, 1 -pair 600/800 Hz. modulated by 16 Hz, 1 second on-3 sec- onds off 2.400 Hz, modulated by 10 Hz! 1 second on-3 seconds off 20 Hz! 15OV P-P: 1 second on-3 seconds off 20 Hz, 15OV P-P, l/4 second on-l/4 second off-l/4 second on-l/4 second off @ 4-second intervals. 600 Hz, 1 second on-3 seconds off 870 Hz: 1 second/710 Hz, 2-l/2 seconds (5 rings) 870 Hz. l/2 second/710 Hz, 2-l/2 seconds (5 rings) 2.400 Hz, 1 second on-3 seconds off 400 Hz, continuous 400 Hz? 1 second on-3 seconds off 400 Hz, i/4 second on-l/4 second off 400 Hz, l/8 second on-l 18 second off 600 Hz. 1 second on only (via electronic telephone speaker) 600 Hz. 1 -second on only (via electronic telephone speaker) 600 Hz. 112 second on only (via handset) 2.400 Hz. modulated by IO Hz, 1 second on-l second off Pushbutton; system-generated DTMF or dial pulse 117VAC; 60Hz 40 watts 100 watts 32 - 122F(O .., 50°C) 20 m 80% relative humidity without condensation
STRATAS,/VI, GENERALDESCRIPTION AUGUST1989 TABLEB STANDARDFEATURES SYSTEM l All Call Voice Page l Alternate Point Answer o Automatic Dialing-System l Automatic Hold Recall l Automatic Release from Hold l CO Line Call Pickup Groups (Vie only) e Conferencing (non-amplified) l CTXiPBX Compatible l CTX Ringing Repeat l Delayed Ringing l Distinctive Ringing l DTMF and Dial Pulse CO Line Compatible l DTMF Signal Time (80/160 ms) 0 Dual FCC Registration l External Page Interface l Flexible Intercom Numbering l Flexible Button Assignment 0 Flexible Line Ringing Assignment l Forced Account Code 0 Group Paging 9 Least Cost Routing (VI, only) l Automatic Callback (Intercom) @ Automatic Dialing Buttons s Automatic Dialing-Station s Automatic Off-hook Selection * Busy Override l Call Forward @ Call Pickup * Call Transfer with Camp-on * COICTXIPBX Feature Buttons l Directed Call Pickup 9 Direct Station Selection (DSS) Buttons s Distinctive LED Indications l Incoming Call l In-use l On-hold 0 Do Not Disturb s Do Not Disturb Override 0 DP’MF Mode Change (TONE Button) 0 Exclusive Hold * Executive Override (Break-in) l Live System Programming . l Message Waiting l MF Signal Time (160/80 ms) l Multiple Simultaneous Han&free Intercom Paths l Music-on-Hold Interface l Night Ringing Answer Code l Night Ringing Over External Page (Vie only) * Night Transfer * Non-blocking Dialing l Outgoing Call Restriction @ Privacy/Non-privacy * Relay Service (VI, only) l Station Hunting 0 Toll Restriction (6-digit) l Toll Restriction Override by System Automatic Dialing d ._ l Trunk-to-Trunk Connection e Voice or Tone Signaling * Wall Mountable Key Service Unit STATION s Liquid Crystal Display Features l Alphanumeric Messaging - Busy Station Messaging - Called Station Messaging - Calling Station Messaging - Remote Station Messaging l Busy Lamp Field (BLF) Indications l CO Line Identification l Speed Dial Memo l Timed Reminders 0 Microphone Cut-off Button l Modular Handset and Line Cords l On-hook Dialing * Privacy Button l Privacy Override * Private CO Lines 0 Pushbutton Dialing l Remote Retrieval of Held Calls * Repeat Last Number Dialed l Ringing Line Preference e Flash Button (CTXIPBX Transfer or CO Dial l Saved Number Redial Tone Recall) l Toll Restriction Override Code l Handsfree Answerback l ,Trunk Queuing -7-
STRATASJVI, GENERALDESCRIPTION AUGUST1989 TABLEC OPTIONALFEATURES l lA2 Key System Interface (HCNB) 0 Amplified Conference l Auxiliary Device Interface (HIOB) l Call Forward to Voice Mailbox l Message Waiting Indication l Voice Mail Control l Background Music with Station Control l Door Phone/Monitor Station l Alarm Button l Door Lock Button l Electronic Telephones l 1 O-button Handsfree Answerback or speak- erphone l 20-button Handsfree Answerback l 20-button Liquid Crystal Display l External Amplified Speaker (HE%) l Amplified Speaker , l Loud Ringing Bell * Talkback Amplified Speaker l External Page Amplifier .*- l Music-on-Hold Source l Off-hook Call Announce l Off-premises Extension l MRGU l Off-premises Line . Remote Administration/Maintenance l Station Message Detail Recording (SMDR) l System Battery Backup , Key 24 VDC Backup Battery External Speaker External Music Source Service 1 Jnit lT!@sk Standard Phone 1 O-huttnr Electronic Telephone L-_CO/PBX Lines ___f FlGURE12-SYairtlvl UlALiHAM .> -8-
STRATAS,/VI, GENERAL DESCRIPTION AUGUST 1989 STRATA 20.button LCD I I lllil Electronic Teleph - 1, To CO/PBx ‘3.Pair requred for Off-hook Call Annoonce STRATA VI, 1 O-button Electrons Telephone SSTU --2 22 25 20.button LCD I Elecrrontc Telephone I I lllll ,* EXtWnal Speaker iHESl3) FIGURE 13-FLiNCTI DNAL BLOCK DIAGRAM -- -e -9-
STRATAS,/VI, GENERAL DESCRIPTION AUGUST 1989 STMU SDTU FIGURE 14-STRATA S, KEY SERVICE UNIT 5 SYSTEM OPERATION General A system (Figure 12) consists of a key service unit (VI, HKSU is shown), power supply. up to 16 stations”, HIOB, HDCB, HCNB, HOLB. HSMB and HOXB optional modules. and a maximum of six door phones. The door phone control unit(s) (HDCB) occupy one or two station location(s). All connec- tions between the key service unit and the tele- phones are made via a customer-provided main distribution frame. Using modular line cord(s), the CO lines are then connected between the left side panel and the locally provided RJ-2% (up to two each) or RJ-11 C (up to six each) jacks. An external tuner (or equivalent) is required if the Music-on- Hold/Back-ground Music feature is utilized. “Some optional features reduce maximum station capacities (see Optional Features). Functional block diagrams of both key service units are shown in Figure 13. Each consists of CO and station imerfaces on the main PCB. including a solid-state, space-division matrix and the central control equipment (SCCU/VCCU). Optional inter- facing equipment includes additional station con- nections (SSTU), off-hook call announce (SVCU). remote maintenance (SDTU), off-premises line (HOLB), station message detail record (HSMB/ STMU”), IA2 interface (HCNB), auxiliary device interface (HIOB), door phone controller (HDCB) and door pl,~ne/monitor station, external page SEPU vcou FIGURE 15-STRATA VI, KEY SERVICE UNIT amplifier (SEPU), internal music-on-hold source (SMOU), and power failure (SPFU*) PCBs are also shown. *STRATA Se only -. The system is entirely under the control of a single-chip microprocessor, located (along with the system program and data memories) on the SCCUiVCCU PCB (STRATASe/VIe, respectively), which mounts on the SMAWVMAU, respectively. Connections between the station voice lines and the CO lines are via the switching matrix provided on the SMAU/VMAU PC6 (STRATA Se/ VI,. respectively). The SMAUIVMAU also pro- vides a similar matrix for intercom connection, background music. paging connections and the distribution of various system tones (dial, busy. etc.). 6 SYSTEM CONFIGURATION Key Service Unit The STRATA Se key service unit arrangement illustrated in Figure 14 shows the locations of the various printed circuit boards and optional equip- ment. The STRATA VI, key service unit arrangement illustrated in Figure 1.5 shows the locations of the various printed circuit boards and optional equip- ment. .s -. . -lO-
STRATAS,/VI, GENERALDESCRIPTION - AUGUST1989 NOTE: The optional modules are used on/y when required. All internal boards connect to the main PCB (in some cases, they also attach to the key service unit’s side panel). Complete with all available options, both key service units utilize up to eight printed circuit boards internally (as shown in Figures 14 and 1.5) and various option modules. The names and functions are as follows: SMAUNMAU: The main printed circuit board of the key service unit consists of the following three functions: a) Station interface: An interface between the key service unit and up to four stations (Se) or up to eight stations (VI,), which includes the solid-state. space-division matrix used for voice connections between the stations and the CO/PBX lines. Two-pair wiring is required for each station; one pair carrying voice and other pair carrying control data to and from the station: b) CO Interface: An interface between the key service unit and the public telephone network or PBX for up to two lines (Se) or up to three lines (VI,). Ring detection, hold and dial outpulsing for these lines are performed by this board. Depending upon local CO re- quirements, each incoming line can be sepa- rately connected and programmed to provide DTMF or rotary-dial outpulsing. CJ Tone: Performs a number of miscellaneous system functions: * General system tones e Provides the switching matrix for the de- livery of tones for both paging and inter- com connections. SCCUIVCCU: All system control functions are performed by the single-chip microprocessor on this printed circuit board. The system program stored in ROM. RAM for system operations. and the RAM for system data storage are also lo- cated on this circuit board. A battery on this board protects system memory should a power failure occur. SCOUNCOd: An optional interface between the SMAUNMAU and one/three additional CO line(s). Depending upon local CO requirements, the SCOUNCOU is programmed to. provide DTMF or rotary-dial outpulsing. The SCOU _ serves one CO line; the VCOU serves up to three CO lines, and both serve up to three off- premises lines. SSTU: An optional interface between the key serv- ice unit and stations 18 - 25 (stations 14 - 17 on Se). Each SSTU PCB serves up to four stations. Two-pair wiring is required for each station; one pair carrying voice and the other pair carrying control data to and from the station. SMOU: An optional music-on-hold source that provides electronic synthesized music. A choice of two musical tunes are available, selected via a switch on this board. The SMOU is connected to the SMAUNMAU via an 8-pin connector. SEPU: An optional 3-watt amplifier for external paging. using a customer-supplied 8-ohm speaker (connected to the SMAUNMAU via a 1 O-pin connector). SVCU: The Off-hook Call Announce interface that mounts on the main printed circuit board of the key service unit to provide OCA access. One SVCU is required for every eight stations requir- ing OCA. (Adds two intercom lines in VI,.) SDTU: Provides Remote AdministrationiMainte- nance access via its built-in 300/1200 bps modem. One SDTU per system is required for Remote AdministratioNMaintenance. STMU: Required for connection to an HSMB to provide SMDR for a STRATA Se key service unit. HPSU 6120/7120: Each system’s required volt- ages are provided by one of these factory- installed power supplies. The HPSU connects to a standard 3-wire, 117 VAC, 60-Hz, grounded wall outlet. with a permissible AC input voltage range of 90 -- 130 VAC. HPFB: An optional battery backup unit that is available for the HPSU 6120 (Se). With the optional battery backup assembly installed, all functions of the system will continue to operate
STRATASJVI, GENERAL DESCRIPTION AUGUST 1989 for approximately two to three hours after a loss of normal electrical power. Calls will not be disconnected during switch-over to or from bat- tery power. HPBU-7: An optional battery backup unit for the HPSU 7120 (VI,). It is a printed circuit board that mounts inside the power supply housing and is connected to the recommended battery pack (which is customer-supplied, consisting of two 12 VDC. maintenance-free, automobile-type batteries-80 amp/hour maximum rating). With the optional battery backup assembly installed, all functions of the system will continue to oper- ate for several hours (the actual time period is in direct ratio to the type and size of batteries se- lected) after a loss of normal electrical power. Calls will not be disconnected during switch- over to or from battery power. The HPBU-7 also provides a charge to the battery pack during normal operations. Option Modules HOLB: An off-premises line module that allows the bridging of a CO line! which appears in the system! with a conventional telephone: supervi- sion is provided. Each HOLB provides three circuits, all three of which may be directed to an answering machine (or similar device) attached to the HUNT connector. HDCB: An optional module (two per system maxi- mum) connected to the key service unit at sta- tion 13 and/or 14 (station 11 and/or 12 on Se) that allows up to three (each HDCB) door phonei monitor stations (MDFBs) to ring pre-selected stations. The HDCB has three outputs (A, 8. C), which are modular connectors for the three MDFBs. Outputs B and C may be used for the Door Lock feature. An alarm monitor can be used at station 11113C only. HOXB: An external module that serves as an interface between the key service unit and con- ventional. standard telephones or off-premises extension (OPX) lines. Each HOXB PCB serves two extensions: Se supports two HOXBs, VI, supports four. An HOXB will operate with either DTMF or rotary-dial telephones. One auxiliary ring generator/power supply (MRGU) is required for use with up to three HOXBs. HSMB: Serves as an interface between the key ’ service unit and a printer or storage device used for the SMDR feature. The module is equipped with an RS-232C interface and connects to the left side panel via one supplied 8-wire modular connector (one HSMB per Svstem). (Se also requires an STMU PCB.) - HCNB: Provides an interface between a IA2 key system and the CO lines appearing therein to a STRATA, system. One HCNB is required for every three lines where (j ::i appearances are desireo. AI.$IJ. A-IeD-! _._ rVI bLI Ji, lamp signal detec- tion and cir,; outpulsing are performed by this module (see Figure 16). ’ Kev -CO/CTX/PBX Lines HKSU 1 co [- T&R : OPL OPL HCNB 1 1 FIGURE16 1A2lNTERFACEFUNCTlONALBLOCKDlAGRAM HIOB: Provides one circuit to interface with exter- nal devices such as voice mail port, answering machine, standard telephone. modem, etc. Up to eight HlOBs (four in Se) may be installed in a system. A 24 VDC power supply, which con- nects to the unit via a 7’ cord and plugs into a 117 VAC! 60 Hz outlet, is included with each HIOB. Each HIOB is connected to a proprietary station port. reducing station capacity accordingly. Station Equipment The principal components of the electronic
telephone are: handset, dial pad. speaker, mi- crophone, two volume controls, four fixed feature buttons, an 5 button, and 9 or 19 flexible CO/ feature buttons, LED indicators are provided for all buttons except m and m. See Figures 9? 10 and 11. A 20-button Liquid Crystal Display electronic telephone (Figure 11) with speakerphone may be located at any or all of the stations. The 32- character alphanumeric display provides many capabilities-an accurate clock/calendar in its idle state; and elapsed time, dialed number, calling station and CO line are just a few of the features available. For additional explanations of the fea- tures listed below, see Liquid Crystal Display. @ Alphanumeric Messaging l Busy Station Messaging l Called Station Messaging l Calling Station Messaging l Remote Station Messaging l Busy Lamp Field (BLF) Indication l CO Line Identification l Speed Dial Memo l Timed Reminders All phones are easily converted for wall mount- ing, feature .moduiar handset cords. are equipped with a second modular connector for headset connection. and are connected to the system via modular line cords. The optional door phone/monitor station (Fig- ure 8) ailows distinctive ringing to preselected station(s). When a station dials an individual door phone, a circuit providing monitoring capabilities on the intercom is established. This option requires station 13 and/or 14 (station I 1 and/or 12 in STRATA Se) to be replaced by a door phone control unit (HDCB) and up to six door phone units (MDFBs)- three each HDCB. One door phone/monitor (only station 13C for VI,; 11 C for S,) can be replaced by an alarm control circuit on starion 13/i 1 HDCB and one by a door lock control circuit on ail HDCBs. An external amplified speaker (HESB) may be connected in any one of the following three appli- cations: l Loud Ringing Bell: Allows you to amplify the tone of a pagingiringing signal without using STRATAS,/VI, GENERAL DESCRIPTION AUGUST 1989 other manufacturer’s equipment. Three-pair wiring is required for this application. . Amplified Speaker: Allows you to use the HESB . as a paging speaker, reducing the need for other manufacturer’s paging equipment. Taikback Amplified Speaker: Allows you to provide a talkback speaker in areas where a telephone is not needed. For&alkback opera- tion, connect the HESB to the door phone unit (MDFB), which is used as a microphone; how- ever, the push-button is inoperative. The HESB is a 6” 3-watt speaker with an amplifier that is built into an attractive speaker box (Figure 8). A +I2 VDC power supply (HACU-120), which connects to the back panel via an 8’ cord. is included with each HESB. Installation The key service unit is configured for wall mounting only. * All external devices are connected to the key service unit via connectors and terminals on the side panels as follows: a) CO lines are connected to the key service unit right side panel via separate (one for each line) single-pair modular cords or a single 3-pair modular cord (Se); or two 3-pair or six single- pair modular cords (Vle). b) The station connection points are extended from the key service unit to the main distribution frame using 3-pair modular line cords. The individual telephones are connected to the main distribution frame using 3-pair station cables. c) A screw-terminal barrier strip is mounted on the left-hand side of the key service unit to provide attachment points for the music-on-hold source input. relay service (Vie only) and external page output). d) Two (only one for Se) modular connectors are also provided on the left side panel for two (only one for Se) optional off-premises line moduies (HOLBs). The power supply is mounted inside the key service unit. In STRATA Se a connector is provided on the left side panel for optional system reserve power (HPFB). In STRATA VI, an optional battery -13-