    TROUBLESHOOTING 
    CONTENTS MAP 
    TOP    
     
     5.2 How to Check and Reset the Consumables Counters 
     
     
    For confirming the abrasion of consumables and resetting the counters, u\
    se [Software Operation Panel] on your computer as 
    shown below.
     
     Checking the Consumables Counters
     
    1.  Turn on the scanner, and confirm if it is connected correctly to your co\
    mputer.
    2.  From the [start] menu, select [All Programs]Õ[Scanner Utility for Microsoft Windows]Õ[Software  Operation Panel].
       
     
    The [Software Operation Panel] dialog box appears.
       
     
       
    3.  From the list on the left of the panel, select [Device Setting]. 
    						
    							
     
      
      You can confirm the following information in this panel: 
     
    Total Page Count (ADF) Total scanned sheets
    Brake Roller  Number of sheets scanned since last replacement of the Brake roller
    Pick Roller  Number of sheets scanned since last replacement of the Pick roller
    Remaining Ink  Remaining ink in the imprinters (sold separately) ink cartridge. 
    (Displayed only when the imprinter option is used.)
      
     Resetting the Consumables Counters 
    Reset the consumables counter(s) every time you replace the consumable\
    (s), following the procedure given below.
     
    1.  Click the [Clear] button beside the replaced consumable. 
    						
    							
      
    2.  Click the [OK] button on the displayed confirmation message. 
     
    The counter is reset to 0. 
    (The remaining ink indication (percentage) is reset to 100.)
       
    3.  If you want to close the [Software Operation Panel] dialog box, click th\
    e [OK] button.
     
         
     Consumables Replacement Message
    The following message may appear while using the scanner:
     
     
     Replace consumables when this message is displayed. 
    						
    							
      
    When you click the [Ignore] button, this message disappears and scanning\
     continues. 
    You may be able to continue scanning for a while, however, it is recomme\
    nded that you replace the consumable as soon as 
    possible. 
    To stop the scanning and replace the consumable right away, click the [C\
    ancel] button.
       
    For the replacement of consumables, refer to the following sections.
    Pick roller: 5.4 Replacing the Pick Roller
    Brake roller: 5.3 Replacing the Brake Roller
         
     
    All Rights Reserved. Copyright 2007 © PFU LIMITED 
    						
    							
    fi-6130 / fi-6230 Image Scanner Operators Guide
     
     
     
    TROUBLESHOOTING 
    CONTENTS MAP 
    TOP    
     
     5.3 Replacing the Brake Roller 
     
     
    1.  Remove any documents from the ADF paper chute.
      2.  Open the ADF by pulling the ADF open lever and turning the ADF to the fr\
    ont. 
       
     ADF open lever 
     
     
     CAUTION
    Be careful, the ADF may close and pinch your finger.
     
      
    3.  Remove the Brake roller from the scanner. 
     1)Grab both sides of the Brake roller cover, and press to the inside and p\
    ull down (towards you), as shown in the 
    illustration below.
     
     
       
     
    2) Lift up the right side of the Brake roller and remove the right side of \
    the shaft. Then pull the left side of the shaft 
    out of its hole to remove it. 
    						
    							
     
     
      
    4.  Remove the Brake roller from the shaft.
      
     
       
    5.  Attach a new Brake roller.
     Insert the shaft to the Brake roller aligning the shaft tab with the slo\
    t of the Brake roller.
     
     
     Brake rollers slot  
     Shaft tab 
       
    6.  Attach the Brake roller to the scanner.
     Attach the Brake roller to the scanner in reverse order of removing.
       
      1)Set the left side of the shaft into place first, then fix the right side\
     of the shaft.
     
     
     
       
      2)Close the Brake roller cover.
       
    7.  Close the ADF. Press down on the center of the ADF to return it to its o\
    riginal position until the ADF 
    button locks.  
    						
    							
      
     
       
      With the movie below, review the procedure to replace the Brake roller.
     
      
    8.  Reset the Brake roller counter.
     For how to reset the Brake roller counter, see Section 5.2 How to Check and Reset the Consumables Counters.
       
     
    All Rights Reserved. Copyright 2007 © PFU LIMITED 
    						
    							
    fi-6130 / fi-6230 Image Scanner Operators Guide
     
     
     
    TROUBLESHOOTING 
    CONTENTS MAP 
    TOP    
     
     5.4 Replacing the Pick Roller 
     
     
    1.  Remove any documents from the ADF paper chute.
      2.  Remove the ADF paper chute from the scanner.
     ADF paper chute 
     3.  Open the ADF by pulling the ADF open lever and turning the ADF to the fr\
    ont. 
      ADF open lever 
     
     CAUTION
    Be careful, the ADF may close and pinch your finger.
       
    4.  Remove the Pick roller from the scanner. 
     
    1) Use the handle in the middle of the sheet guide to open it as shown \
    below. 
    						
    							
     
     Sheet guide  
     2) Rotate the Pick roller lever in the direction of the arrow.
     
     Lever
      3) Slide the Pick roller in the direction of teh arrow, and then lift i\
    t up to remove the shaft from the hole.
     
     
     
     CAUTION
    Be careful not to touch the gear beside the lever of the Pick Roller as \
    grease is applied to it. 
       
       
    5.  Remove the Pick roller from the shaft.
     
    Remove the Pick roller from the shaft while lifting up the tab on the Pi\
    ck roller. 
    						
    							
     Tab  Pick roller   Shaft
      
     
     CAUTION
     
    If you lift the pick roller tab with your fingernail, it may hurt your f\
    ingernail. Use a 
    paper clip to lift the pick roller tab if you cannot do it with your fin\
    ger. 
       
    6.  Attach a new Pick roller.
     
    Insert the new Pick roller aligning the screw on the shaft with the slot\
     in the Pick roller.
       
     
     Pick roller shaft  Screw  Slot  Pick roller 
     ATTENTION
     
    Make sure that the Pick roller is correctly attached. The incompletely-a\
    ttached Pick roller 
    might cause document jams or other feed errors. 
    When attaching the Pick roller to the shaft, make sure that the roller’\
    s tab clicks into place. 
       
    7.  Attach the Pick roller shaft to the scanner. Attach the Pick roller shaft to the scanner in reverse order of removing\
    . 
    1) Set the right side of the Pick roller into place first, then fix the\
     left side of the roller.
       
    						