Fujitsu Fi6130 Operators Manual
Have a look at the manual Fujitsu Fi6130 Operators Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 86 Fujitsu manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

fi-6130 / fi-6230 Image Scanner Operators Guide TROUBLESHOOTING CONTENTS MAP TOP Chapter 4 DAILY CARE This chapter describes how to clean the scanner. CAUTION When operating the scanner, the ADFs glass becomes very hot. Before you clean inside the scanner, turn off its power and unplug the A\ C adapter from the outlet. Wait for at least 15 minutes for the ADF glass to cool down. Do not turn off the scanner when you clean the Feed and Eject rollers. \ WARNING Do not use any aerosol sprays or alcohol based sprays to clean the scann\ er. Dust blown up by strong air from the spray may enter the inside of the s\ canner. This may cause the scanner to fail or malfunction. Sparks, caused by static electricity, generated when blowing off dust an\ d dirt from the outside of the scanner may cause a fire. All Rights Reserved. Copyright 2007 © PFU LIMITED

fi-6130 / fi-6230 Image Scanner Operators Guide TROUBLESHOOTING CONTENTS MAP TOP 4.1 Cleaning Materials and Locations Requiring Cleaning Cleaning Materials The table below shows the cleaning materials that are used on this scann\ er. Cleaning Materials Part No. Remarks Cleaner F1 PA03950-0352 1 bottle (100 ml) Moisten cloth with this fluid and wipe the scanner clean. (*1) Cleaning wipe PA03950-041924 sheets per pack (*1)(*2) Soft, dry cloth Commercially available. *1: For details on Cleaner F1, consult the agent where you bought your s\ canner or an authorized FUJITSU service provider. *2: Pre-moistened with Cleaner F1, Cleaning Wipes are used instead of mo\ istened cloths. HINT It may take long before the cleaner vaporizes if a large quantity is use\ d. When cleaning the scanner parts, dampen a cloth with modest quantities of the cleaner. In \ addition, wipe off the cleaner completely with a soft lint-free cloth to leave no residue o\ n the surface of the cleaned parts. Locations and Cycle for Cleaning Location Standard Cleaning Cycle Brake roller Clean every 5,000 scanned sheets. Pick roller Feed roller Plastic roller Eject roller Glass Ultrasonic sensor

ATTENTION The scanner must be cleaned more frequently when the following documents\ are used: l Documents of coated paper l Documents with printed text or graphics almost covering the entire surfa\ ce l Chemically treated documents such as carbonless paper l Documents containing a large amount of calcium carbonate l Documents written by pencil l Documents on which the toner is not fused sufficiently Detergent for cleaning windows or glass cleaner can be used instead of C\ leaner F1. However, do not use paint thinner or other organic solvents. All Rights Reserved. Copyright 2007 © PFU LIMITED

fi-6130 / fi-6230 Image Scanner Operators Guide TROUBLESHOOTING CONTENTS MAP TOP 4.2 Cleaning the Flatbed [fi-6230 only] 1. Open the document cover. 2. Clean the following locations using a soft cloth moistened with Cleaner \ F1. Plastic cover Document bed ATTENTION Do not allow moisture to get inside the device during cleaning. 3. Wait for cleaned parts to dry. 4. Gently close the document cover. All Rights Reserved. Copyright 2007 © PFU LIMITED

fi-6130 / fi-6230 Image Scanner Operators Guide TROUBLESHOOTING CONTENTS MAP TOP 4.3 Cleaning the ADF As a Guideline, clean the ADF every 5,000 scanned sheets. Note that this\ guideline varies according to the type of documents you scan. For example, it may be necessary to clean the ADF more frequen\ tly if documents are scanned when the toner is not sufficiently fixed on the printout. CAUTION The glass surface of the ADF becomes hot during the operation of the sca\ nner. Before you start to clean the inner parts of the scanner, disconnect the\ AC adapter from the power outlet, and wait at least 15 minutes to let the glass cool down. 1. Open the ADF by pushing on the ADF open lever and turning the ADF to the\ front. ADF open lever CAUTION Be careful, the ADF may close and pinch your finger. 2. Clean the following locations with a soft, dry cloth moistened with Clea\ ner F1. 00

No.Item 1 Brake rollers (x 2) 2 Feed rollers (x 2) 3 Eject rollers (x 2) 4 Glasses (x 2) 5 Pick rollers (x 2) 6 Plastic rollers (x 4) 7 Ultrasonic sensors (x 2) ATTENTION To avoid damaging the document sensors, take care that the cloth does no\ t get hooked into them when cleaning the inside of the ADF. Document sensor Brake roller Lightly clean the Brake roller along the grooves on the roller taking ca\ re not to scratch the roller surface. When cleaning the Brake roller, remove it from the scanner. For how to r\ emove the Brake Roller, see Section 5.3 Replacing the Brake Rollers. Pick roller Lightly clean the Pick roller along the grooves on the roller taking car\ e not to scratch the roller surface. Take particular care in cleaning this roller as black debris on it adversely affects the\ pickup performance.

Plastic roller Lightly clean the Plastic roller taking care not to damage the roller su\ rface. Take particular care when cleaning this roller as black debris on it affects document pick performance. Be caref\ ul not to damage the sponges attached around the middle of the roller. Glass Clean lightly. HINT If the glass is dirty, vertical streaks may apper in the scanned images.\ Ultrasonic sensor Clean lightly with a dry cloth. With the movie below, review the procedure to clean the Brake roller, Pi\ ck roller, Plastic roller, and ADF glass surfaces: Feed roller/Eject roller 1)Open the ADF when the indication of the Function Number display is not \ P or 0. If you open the ADF when the indication of the Function Number display i\ s P or 0, the Feed rollers/Eject rollers will not rotate even you perform the operation of step 2 below. 2) Simultaneously hold down the [Send to] and [Scan] buttons on the Operato\ r Panel. The Feed rollers/Eject rollers start to rotate slowly. 3) Hold a soft cloth moistened with cleaning fluid against the surface of t\ he rotating Feed rollers so that it lightly cleans the surface of the rollers. Take particular care when cleaning th\ ese rollers as black debris on these rollers affects pickup performance. As a guideline, seven presses of the [Send t\ o] and [Scan] buttons make the Feed rollers/Eject rollers to rotate one full turn.

[Send to] Button [Scan] Button CAUTION In step 2, all the Feed rollers/Eject rollers turn at the same time. Whe\ n cleaning the Feed rollers or Eject rollers, be careful not to touch the other rotating Fee\ d rollers/Eject rollers. With the movie below, review the procedure to clean the Feed rollers/Eje\ ct rollers: 3. Press down on the center of the ADF to return it to its original positio\ n until the ADF button locks. Press center of ADF. ATTENTION When the ADF has returned to its original position, make sure that it is\ completely closed. Feeding errors may occur if the ADF is not closed completely. All Rights Reserved. Copyright 2007 © PFU LIMITED

fi-6130 / fi-6230 Image Scanner Operators Guide TROUBLESHOOTING CONTENTS MAP TOP Chapter 5 REPLACING CONSUMABLES This chapter describes how to replace scanner consumables. In this chapter Windows XP screenshots are illustrated. The screens and operations may differ slightly if the OS that you are us\ ing is other than Windows XP. Also, when the FUJITSU TWAIN32 or FUJITSU ISIS scanner driver is updated\ the screens and operations noted in this chapter will differ slightly. Refer to the manuals provided with the update. WARNING When operating the scanner, the ADFs inside glass becomes very hot. Before you replace the consumables, turn off its power and unplug the AC\ adapter from the outlet. Wait for at least 15 minutes. All Rights Reserved. Copyright 2007 © PFU LIMITED

fi-6130 / fi-6230 Image Scanner Operators Guide TROUBLESHOOTING CONTENTS MAP TOP 5.1 Consumables and Replacement Cycles The following table shows the specifications of consumables and their st\ andard replacement cycle. It is recommended that you stock extra consumables before the ones in the scanner reach the end\ of their service life. The consumables must be replaced periodically. You can check the number of scanned pages for the\ Brake roller unit and the Pick roller unit by referring to each counter on this scanner. For how to check the count, s\ ee Section 5.2 How to Check and Reset the Consumables Counters. Description P/NStandard Replacement Cycle Brake roller PA03540-0001After 200,000 sheets or one year Pick roller PA03540-0002After 200,000 sheets or one year The replacement cycles above are rough guidelines for the case of using \ A4/Letter woodfree or wood containing paper 64 g/ m2 (17 lb). This cycle varies according to the type of the paper used \ and how frequently the scanner is used and cleaned. ATTENTION Use only the specified consumables to avoid document feeding trouble. To purchase the consumables, contact the FUJITSU scanner dealer where yo\ u purchased the scanner or an authorized FUJITSU scanner service provider. All Rights Reserved. Copyright 2007 © PFU LIMITED