Home > Telrad Digital > Communications System > Telrad Digital Emagen Unified Messaging System Manual

Telrad Digital Emagen Unified Messaging System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Telrad Digital Emagen Unified Messaging System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 22 Telrad Digital manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							76-110-0887/0, Issue 1
    3-6
    emaGEN, on one, two or three OCD cards;
     inserting the OCD card(s), with MIM(s) mounted, in the 
    unite 
    system cabinet.
     Connection between 
    emaGEN and the unite system;
    Section 3.9.3 and Section 3.9.4, below, describe:
     making the data connections between: 
    -- the first and, if present, fourth or last, 
    emaGEN-PC card -- 
    and the OCD card(s) in the 
    unite system cabinet;
     making the audio connection between: 
    -- each 
    emaGEN card in the emaGEN-PC 
    -- and the OCD block in the 
    unite system MDF, via the audio 
    junction box.
    3.8 INSTALLING emaGEN VOICE MAIL CARDS 
    IN THE emaGEN-PC
    3.8.1emaGEN voice mail card jumper settings
    One or more of the following three types of 
    emaGEN-PC four tele-
    phony port, single slot, half-sized, ISA compatible voice processing 
    cards, manufactured by Brooktrout Technology, are used, in order to 
    set up your system. 
    Depending on which of these cards are to be used in your system, 
    refer to  the corresponding Brooktrout Technology Hardware instal-
    lation Guide brochure:
     Prelude Quartet card -- Part Number 934-011-40, Revision 1.00;
     Vantage Volare card  -- Part Number 934-009-90, Revision 1.00;
     RDSP 432 card         -- Part Number 73-00-0014, Revision 1.00.
    You should comply with all instructions in the brochure before insert-
    ing the respective type of 
    emaGEN-PC card into the emaGEN-
    PC.
    The Quartet board has fixed settings as card no. 1, for which no 
    juper setting is required. For junper settings of all other cards, follow 
    the required jumper settings shown in Table 3-1, below, for each of 
    the respective cards. In this table: O = open circuit X = closed cir-
    cuit. 
    						
    							Section 3:  INSTALLATION
    3-7
    Table 3-1    I/O port jumper settings
    3.8.2
    emaGEN-PC voice mail card insertion
    You must insert the 
    emaGEN-PC cards into the emaGEN-PC.  
    Cards can be placed in any PCI slot.
    WARNING
    Turn off and disconnect power to the PC,
    before starting any card insertion proce-
    dure.
    The physical act of installation is the same as for any  other PC card. 
    This procedure is not described here, since it may vary from one PC 
    model to another. Refer to your PC manual for card installation 
    instructions.
    CAUTION
    The 
    emaGEN-PC printed circuit cards
    contain components that are sensitive to
    static electricity and should not be handled
    except as needed to avoid any problem
    with electrostatic discharge. Hold the card
    by its outer edges. The use of a wrist
    ground strap is recommended, as shown in
    Figure 3-1, below.
    Card 
    no.MSB jumpers LSB
    9876543210
    1 OOXXXXXXXX
    2 OOXXXXXXXO
    3 OOXXXXXXOX
    4 OOXXXXXXOO
    5 OOXXXXXOXX
    6 OOXXXXXOOO
    7 OOXXXXXOXX 
    						
    							76-110-0887/0, Issue 1
    3-8
    Figure 3-1    Wrist strap guarding against electrostatic discharge
    3.9 SYSTEM PREPARATION AND CONNECTIONS
    TO emaGEN
    3.9.1 Mounting an MIM on an OCD card
    Figure 3-2, below, shows the three module positions on the OCD 
    card. Each OCD card can accommodate up to three cartridge mod-
    ules, each serving a special option function. 
    You must connect one MIM (multiple interface module) on the OCD 
    card for each group of four 
    emaGEN ports to be connected to the 
    card. The MIM connects the voice channels to the 
    emaGEN-PC.
    An 
    emaGEN system of up to 12 voice mail ports can be handled by 
    one OCD card. However, a 16 port voice mail system requires four 
    MIMs, which necessitates two OCD cards. For a system of between 
    five and 12 ports you can, if you choose, take advantage of the Mul-
    tiple Communication Ports feature and balance system load (espe-
    cially if the system includes SMDR) and improve system 
    performance by placing MIMs on two different OCD cards, as 
    described in Section 3.9.3, below.
    You can select any positions on the OCD cards for the MIMs. If you 
    require two OCD cards, for example, you can put two MIMs on each 
    card; or you could put three MIMs on one card and the fourth on the 
    second.
    1. You must appropriately program the 
    unite system, as described 
    in configuration programming covered in Section 19, below, to 
    match the selected MIM position(s).
    BuckleStrap
    Belt
    Desk for ground 
    						
    							Section 3:  INSTALLATION
    3-9
    2.  You then assign voice channel and DN numbers to the ema-
    GEN
     ports. 
    3. Lastly, you physically connect 
    emaGEN-PC cards, via the 
    audio cable, junction box, and MDF, to the audio channels of the 
    OCD card MIM(s).
    To mount the MIM on the OCD card, perform the following steps, as 
    shown in Figure 3-2, below:
    1. Place the OCD card on a soft, clean surface (a piece of sponge 
    or cardboard) with the components facing up.
    2. Select the position in which the MIM is to be attached to the 
    OCD card:
     3, the upper position, with 20 and 64-pin connectors 
    J6 and J9, respectively;
     2, the middle position, with 20 and 64-pin connectors 
    J5 and J8, respectively;
     1, the lower position, with 20 and 64-pin connectors 
    J4 and J7, respectively.
    3. Plug the MIM into the selected pair of 20 and 64-pin connectors.
    4. Make sure the module is seated firmly against the OCD card.
    5. Tighten the screw on the top of the module.
    NOTE
    The position in which the MIM is assigned
    and mounted on the OCD card determines
    which voice channels and which wires will
    be dedicated to it for connection between
    the 
    emaGEN-PC and the unite system
    cabinet. 
    						
    							76-110-0887/0, Issue 1
    3-10
    Figure 3-2   Inserting the MIM on the OCD card
    3.9.2 Inserting an OCD card into the system cabinet
    To insert an OCD card in one of the 
    unite system cabinet slots, 
    perform the following steps, as shown in Figure 3-3, below:
    1. With the two plastic extension tabs on the end of the OCD card 
    extended outwards, slide the card into the guide runners of the 
    selected slot.
    2. Carefully fit the card into the V-shaped insertion guides.
    3. Ensure that the female connector on the card is aligned with its 
    male counterpart on the system cabinet backplane.
    4. Place both thumbs on the plastic tabs and press the card firmly 
    into place.
    5. Fold the tabs flat against the card until they snap into place.
    Each OCD card is connected to the MDF by means of a 25-pair 
    cable. This cable is standard for all cards in the 
    unite system, as 
    described in the 
    unite family of systems Installation manual. 
    						
    							Section 3:  INSTALLATION
    3-11
    Figure 3-3   OCD card insertion 
    3.9.3 Completing the data connection
    The first 
    emaGEN card in the emaGEN-PC connects, as 
    described below, directly to the OCD card in the 
    unite system cab-
    inet, by means of the RJ45 connector located at the end of  the OCD 
    card. If two, or more, 
    emaGEN-PC cards are installed, you connect 
    only the first 
    emaGEN-PC card, card number 1, to the OCD card. If 
    four, or more, 
    emaGEN-PC cards are installed, you must connect 
    the fourth, or last, 
    emaGEN-PC card to the second OCD card. 
    If you choose, for a system of between five and 28 ports, as 
    described earlier, to take advantage of the Multiple Communication 
    Ports feature by placing MIMs on two different OCD cards, there 
    must be a data cable connection between the last 
    emaGEN-PC 
    card and the second OCD card as well.
    NOTE
    If your system has two, or more, OCD
    cards, it is recommended that you also con-
    nect the second, or last, OCD card to the
    emaGEN-PC card assigned the ports
    operating the SMDR features. This will
    divide the communication load between the
    emaGEN-PC and the two cards. 
    						
    							76-110-0887/0, Issue 1
    3-12
    The emaGEN-PC card connection to the OCD card is by means of 
    a cable, shown in Figure 3-4 terminated by:
     A 9-pin D-type female connector on the 
    emaGEN-PC com port;
     An RJ45 male connector on the OCD card end of the cable.
    Figure 3-4    Data cable from 
    emaGEN card to OCD card
    The wire functions and connections for the 
    emaGEN-PC card to 
    the OCD card data cable are shown in Table 3-1.
    Table 3-2     Connections of data cable from emaGEN-PC card 
    to OCD card
    3.9.4 Performing the audio connection
    Each 
    emaGEN-PC card must have an audio connection to the 
    unite system. It is connected to an OCD card, as shown in Figure 3-
    5, below:
    9-pin D-type connectorRJ45 connector
    pin numberfunctionpin numberfunction
    2transmit6receive
    3receive5transmit
    5ground4ground
    5
    9
    6
    1
    2
    3 4
    87
    9-pin D-type female cable connector
     -- plugs into male PC com  port RJ45 m ale cable connector - plugs  into
    RJ45 female connector on OCD card
    With spring clip up - as shown -
    cable w ires  are num bered 1 to 8, from  left to rig456
    5
    3
    2 
    						
    							Section 3:  INSTALLATION
    3-13
    Figure 3-5   emaGEN cabling from emaGEN-PC to OCD card
    Note in the Figure 3-5, that:
     Connector J3 on the 
    emaGEN-PC card connects to the OCD 
    card containing the MIM by means of a cable, shown in Figure 3-
    6, terminated by an RJ11 connector on both ends.
    Each of the terminal pairs in the junction box is connected, via a 
    pair of wires, as shown in Figure 3-6, to the audio terminals in the 
    MDF of the corresponding voice channel utilized as an 
    ema-
    GEN
     port.
     A standard 25-pair cable, or cables, used to connect the OCD 
    block in the MDF to each OCD card in the 
    unite system cabinet, 
    will then also make the final connection of  the  corresponding 
    emaGEN ports.
    This information should assist the installer in selecting the MDF ter-
    minals to which each 
    emaGEN audio port from the junction box is 
    to be wired.
    PC
    PC com portJ1
    J2
    MDF
    OC D card in system cabinet
    Standard 25-pair cable/s from  M DF Audio cable/s from junction box to MDF
    Vo ic e  m a il c a rd
     in the P CJunction box
    Data cable from
    PC to OCD card
    Two two-pair audio cables  from
    PC card to junction box 
    						
    							76-110-0887/0, Issue 1
    3-14
    The wire functions and connections for the audio cable from the 
    emaGEN-PC card to a junction box, and from that junction box to 
    the MDF, are shown in Figure 3-6. For a detailed description of the 
    unite system cabinet to MDF connections, refer to the unite family 
    of systems Installation manual.
    .
    Figure 3-6   Audio cable from 
    emaGEN-PC voice mail card 
    to four port junction box
    Figure 3-7, below, shows the numbers and colors of each pin of the 
    25-pair cable connector from the OCD block in MDF to the OCD 
    card in the 
    unitesystem cabinet, and each wire in this standard 
    cable which corresponds to the voice channels of each OCD card.
    1
    2
    3
    4 1
    2
    3
    4
     1 2 3 4  1 2 3 4Four-pair wiring 
    -- one pair per port -- 
    to OCD block in MDF
    1
    2
    3
    4
    1
    2
    3
    4
    J1
    J2
    Four audio port
     junction box,
    Avdor model
    TA0666,
     or equivalent
    RJ11 connectors to
    emaGEN-PC card 
    						
    							Section 3:  INSTALLATION
    3-15
    Figure  3-7     Typical 25-pair cable connector  from  OCD block in MDF
    3.10 ADDITIONAL STEPS BEFORE ACTIVATING emaGEN
    Although you have made all the required physical connections 
    between the 
    emaGEN-PC and the unite system, you are not yet 
    ready to activate 
    emaGEN. You must now carry out the following 
    steps: 
    						
    All Telrad Digital manuals Comments (0)

    Related Manuals for Telrad Digital Emagen Unified Messaging System Manual