4.2 System [2] Feature Guide 301 4.2.14 Class of Service—COS Settings [2-7-1] Each extension, doorphone port, incoming call distribution group, and CO line group belongs to a certain COS. Certain features can be programmed to behave differently depending on the COS. A maximum of 64 COS can be programmed. TRS / CO Restrictions to features related to making CO line calls can be programmed for each COS. COS Name Specifies the name of the COS. TRS Level—Day, Lunch, Break, Night Specifies the Toll Restriction (TRS) level for making CO line calls in each time mode. TRS Level on Extension Lock Specifies the TRS level for making CO line calls when an extension is locked. DefaultNot stored. Va lu e Ra n g eMax. 20 characters Feature Guide References None Default1 Va lu e Ra n g e1: Allows all CO line calls 2–6: Restricts CO line calls according to the combination of the Denied and Exception Code Tables 7: Restricts all CO line calls Feature Guide References Feature References 1.8.1 Toll Restriction (TRS) Programming References 4.2.8 Time Service—Week Table [2-5-1] 4.3.1 Trunk Group—TRG Settings [3-1-1]—Main—COS 4.3.6 Incoming Call Distribution Group—Group Settings [3-5-1]—Main—COS 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS 4.5.1 Doorphone [5-1]—COS 4.7.1 Denied Code [7-1] 4.7.2 Exception Code [7-2] Default7 Va lu e Ra n g e1: Allows all CO line calls 2–6: Restricts CO line calls according to the combination of the Denied and Exception Code Tables 7: Restricts all CO line calls
4.2 System [2] 302 Feature Guide TRS Level for System Speed Dialing Specifies the TRS level for making a CO line call using System Speed Dialing numbers, which overrides the TRS set for the current time mode. Extension-CO Line Call Duration Limit Enables the extension-to-CO line call duration feature. The length of the call duration can be programmed. Transfer to CO Enables the transferring of a call to a CO line. Feature Guide References Feature References 1.8.2 Extension Lock Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS 4.7.1 Denied Code [7-1] 4.7.2 Exception Code [7-2] Default1 Va lu e Ra n g e1: Allows all CO line calls 2–6: Restricts CO line calls according to the combination of the Denied and Exception Code Tables 7: Restricts all CO line calls Feature Guide References Feature References 1.8.1 Toll Restriction (TRS) Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS 4.6.1 Speed Dialing & Caller ID—Main Table [6-1-1] 4.7.4 Miscellaneous [7-4]—TRS Override by System Speed Dialing DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.10.7 CO Line Call Limitation Programming References 4.2.21 System Options—Option 2 [2-9-2]—Extension - CO Call Limitation 4.3.1 Trunk Group—TRG Settings [3-1-1]—Main—COS 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS
4.2 System [2] Feature Guide 303 Call Forward to CO Enables the forwarding of a call to a CO line. Main The use of features related to extension operations can be programmed for each COS. COS Name Specifies the name of the COS. Account Code Mode Specifies whether the entry of an account code is optional or mandatory when making a CO line call. DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.11.1 Call Transfer Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.3.1.2 Call Forwarding (FWD) Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.2 Wired Extension—FWD/DND [4-1-2] 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS 4.4.8 Portable Station—FWD/DND [4-2-2] DefaultNot stored. Va lu e Ra n g eMax. 20 characters Feature Guide References None DefaultOption Va lu e Ra n g eOption, Forced Feature Guide References Feature References 1.5.4.3 Account Code Entry
4.2 System [2] 304 Feature Guide Outgoing CO Call Printout (SMDR) Enables the automatic recording of outgoing CO line calls for SMDR output. Executive Busy Override Enables the authorization for interrupting an existing call to establish a three-party conference call. DND Override Enables the authorization for making a call to an extension in DND mode by entering the feature number.Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultEnable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.21.1 Station Message Detail Recording (SMDR) Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS 4.10.1 SMDR [10-1] DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.7.2 Executive Busy Override Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.3.1.3 Do Not Disturb (DND) Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.2 Wired Extension—FWD/DND [4-1-2] 4.4.7 Portable Station—Extension Settings [4-2-1] 4.4.8 Portable Station—FWD/DND [4-2-2]—Main—COS
4.2 System [2] Feature Guide 305 Door Unlock Enables the authorization to open the door. Call Monitor Enables the authorization for listening to a busy extension’s conversation. Options The use of features related to extension settings can be programmed for each COS. COS Name Specifies the name of the COS. Time Service Switch Enables the authorization to switch time modes manually. DefaultEnable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.15.2 Door Open Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.7.3 Call Monitor Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—COS DefaultNot stored. Va lu e Ra n g eMax. 20 characters Feature Guide References None DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 2.2.4 Time Service
4.2 System [2] 306 Feature Guide Executive Busy Override Deny Enables the authorization to prevent other extensions from interrupting calls. Group Forward Set Enables setting call forwarding for calls to an incoming call distribution group. Deny Remote Operation by Other Extension Enables the authorization to use the Walking COS or Remote Extension Control feature from a remote location (inside, or outside the PBX using DISA).Programming References 4.2.8 Time Service—Week Table [2-5-1] 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 2.2.1 Class of Service (COS) Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultEnable-Group Va lu e Ra n g eDisable: An extension cannot set call forwarding for any group. Enable-All: An extension can set call forwarding for all groups. Enable-Group: An extension can only set call forwarding for the group to which the extension belongs. Feature Guide References Feature References 1.3.1.2 Call Forwarding (FWD) Programming References 4.3.7 Incoming Call Distribution Group—Member [3-5-2] 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.8.4 Walking COS 1.22.5 Remote Extension Control by User
4.2 System [2] Feature Guide 307 Accept the Call from DISA Enables the authorization to receive calls from DISA. Accept Wireless XDP Parallel Set by Other PS Enables the authorization to allow Wireless XDP Parallel Mode to be set by a PS. Programming Mode Level Specifies the level of authorization for performing PT programming. Manager Specifies the authorization to use manager features.Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultEnable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.15.6 Direct Inward System Access (DISA) Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS 4.5.4 DISA—Message Setting [5-3-2] DefaultEnable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 1.20.3 Wireless XDP Parallel Mode Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS DefaultPROG Only Va lu e Ra n g eDisable: A PT user cannot perform any programming. PROG Only: A PT user can perform only personal programming. PROG and PROG **/*#: A PT user can perform personal and system programming. Feature Guide References Feature References 2.3.2 PT Programming Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS
4.2 System [2] 308 Feature Guide 4.2.15 Class of Service—External Call Block [2-7-2] Each COS can have different CO line groups available for making CO line calls, depending on the time mode (day/lunch/break/night). Select the desired time mode from the list. Outgoing Trunk Group 1–64 Specifies the available CO line groups. 4.2.16 Class of Service—Internal Call Block [2-7-3] Internal Call Block determines the restrictions placed on making intercom calls. The extensions, incoming call distribution groups, and doorphones belonging to a certain COS can be programmed to not receive intercom calls from those belonging to a certain COS. COS Number of the Extension Which Receive the Call from Other Extension 1–64 Specifies the COS combination that blocks intercom calls. DefaultDisable Va lu e Ra n g eDisable, Enable Feature Guide References Feature References 2.2.6 Manager Features Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS DefaultAll Trunk groups: Non Block Va lu e Ra n g eBlock, Non Block Feature Guide References Feature References 1.5.5.3 CO Line Access Programming References 4.2.8 Time Service—Week Table [2-5-1] 4.4.1 Wired Extension—Extension Settings [4-1-1] 4.4.7 Portable Station—Extension Settings [4-2-1] 4.9.1 CO Line Setting [9-1] DefaultAll extensions: Non Block Va lu e Ra n g eBlock, Non Block Feature Guide References Feature References 1.1.2.2 Internal Call Block
4.2 System [2] Feature Guide 309 4.2.17 Ring Tone Patterns—Call from CO [2-8-1] Different ring tone patterns can be selected for incoming CO line calls depending on the CO line groups the calls come through. A maximum of 8 Ring Tone Pattern Tables can be programmed, and any pattern table can be selected for use by an extension. Ring Tone Pattern Table 1–8 Specifies the ring tone pattern for incoming CO line calls. 4.2.18 Ring Tone Patterns—Call from Doorphone [2-8-2] Different ring tone patterns can be selected for incoming doorphone calls depending on the doorphone ports the calls come through. A maximum of 8 Ring Tone Pattern Tables can be programmed, and any pattern table can be selected for use by an extension. Ring Tone Pattern Table 1–8 Specifies the ring tone pattern for incoming doorphone calls.Programming References 4.3.6 Incoming Call Distribution Group—Group Settings [3-5-1]—Main—COS 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—COS 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—COS 4.5.1 Doorphone [5-1]—COS DefaultSingle Va lu e Ra n g eSingle, Double, Triple Feature Guide References Feature References 1.1.3.2 Ring Tone Pattern Selection Programming References 4.9.1 CO Line Setting [9-1]—Trunk Group Number 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—Ring Pattern Table 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—Ring Pattern Table DefaultTriple Va lu e Ra n g eSingle, Double, Triple, S-Double Feature Guide References Feature References 1.1.3.2 Ring Tone Pattern Selection Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—Ring Pattern Table 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—Ring Pattern Table 4.5.1 Doorphone [5-1]
4.2 System [2] 310 Feature Guide 4.2.19 Ring Tone Patterns—Call from Others [2-8-3] Different ring tone patterns can be selected for incoming intercom calls and ringing triggered by certain PBX features (Timed Reminder, Call Back, and Live Call Screening). A maximum of 8 Ring Tone Pattern Tables can be programmed, and any pattern table can be selected for use by an extension. Extension—Ring Tone Pattern Table 1–8 Specifies the ring tone pattern for incoming intercom calls. Timed Reminder—Ring Tone Pattern Table 1–8 Specifies the ring tone pattern for alarm ringing by Timed Reminder. Call Back—Ring Tone Pattern Table 1–8 Specifies the ring tone pattern for callback ringing by Automatic Callback Busy. Live Call Screening—Ring Tone Pattern Table 1–8 Specifies the ring tone pattern for alarm ringing by LCS. DefaultDouble Va lu e Ra n g eSingle, Double, Triple Feature Guide References Feature References 1.1.3.2 Ring Tone Pattern Selection Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—Ring Pattern Table 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—Ring Pattern Table DefaultTriple Va lu e Ra n g eSingle, Double, Triple Feature Guide References Feature References 1.1.3.2 Ring Tone Pattern Selection Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—Ring Pattern Table 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—Ring Pattern Table DefaultS-Double Va lu e Ra n g eSingle, Double, Triple, S-Double Feature Guide References Feature References 1.1.3.2 Ring Tone Pattern Selection Programming References 4.4.1 Wired Extension—Extension Settings [4-1-1]—Main—Ring Pattern Table 4.4.7 Portable Station—Extension Settings [4-2-1]—Main—Ring Pattern Table