Panasonic Kx Taw848 Feature Manual
Have a look at the manual Panasonic Kx Taw848 Feature Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
3.3 PT Programming Feature Guide 231 3.3.11 Card Programming Slot Card Type Reference [900] Slot Card Deletion [901] Slot Card Reset [902] [900]01–11 Reference onlySlot No.Card Name STOREEND [901] 01–11Slot No.Delete To the Next Slot No. NEXT Confirming the deleting operation. STORESTOREEND [902] 01–11Slot No.ResetConfirming the resetting operation.STORESTOREEND
Feature Guide 233 Section 4 KX-TAW848 Maintenance Console Operating Instructions
4.1 Configuration [1] 234 Feature Guide 4.1 Configuration [1] 4.1.1 Slot [1-1] The operating characteristics associated with each service card can be programmed. Slot Type Indicates the type of each slot (reference only). Card Type Indicates the type of service card that is installed or pre-installed in each slot (reference only). This column offers two ways to open the screen to specify the property of each card: Click the desired card in the column. Use the arrow keys to select the desired card in the column, and then click Property. DefaultNot applicable. Va lu e Ra n g eFixed Slot: For initially installed 4 Hybrid ports Free Slots Type A (02–04): For LCOT4/HLC4/PLC4 Free Slots Type B (05–06): For PLC8/SLC8 Option Slots (08–09): For MSG2/DPH4/ECHO8/EXT-CID card Option Slots (10–11): For MSG2/ECHO8/EXT-CID card Installation Manual References 2.2.6 Installing/Removing the Optional Service CardsFeature Guide References None DefaultSlot 00: MPR (Main Processing Card: fixed) Slot 01: HLC4 (Hybrid ports: fixed) Slot 02: LCOT4 (4-Port Analog Trunk Card: installed by default) Other slots: Not stored.
4.1 Configuration [1] Feature Guide 235 Status Indicates the status of the service card in each slot (reference only). This column offers two ways to open the screen to select the card command: Click the desired cell in the column. Use the arrow key to select the desired cell in the column, and then click Command. Value Range Card Type: HLC4: 4-Port Hybrid Extension Card PLC8: 8-Port Proprietary Extension Card PLC4: 4-Port Proprietary Extension Card SLC8: 8-Port Single Line Telephone Extension Card LCOT4: 4-Port Analog Trunk Card MSG2: 2-Channel Message Card DPH4: 4-Por t Doorphone Card ECHO8: 8-Channel Echo Canceller Card EXT-CID: Extension Caller ID Card Maximum Quantity: Extension card: 3 (1 in the Free Slots Type A; 2 in the Free Slots Ty p e B ) Trunk card: 2 MSG2 card: 2 DPH4 card: 1 ECHO8 card: 1 EXT-CID card: 1 Installation Manual References 1.3.1 OptionsFeature Guide References Feature References None Programming References 4.1.2 Slot [1-1] Extension Card Property 4.1.3 Slot [1-1] LCO Card Property 4.1.4 Slot [1-1] DPH Card Property DefaultSlot 00: - (fixed) Other slots: Current status
4.1 Configuration [1] 236 Feature Guide Versi o n Indicates the version of the installed card (reference only). 4.1.2 Slot [1-1] Extension Card Property The property for the extension cards can be specified. SLT Pulse Dial Mode Selects the type of pulse dial transmission appropriate to your area. SLT Off Hook Time Specifies the minimum time required by the PBX to recognize the pulse dial sent from an SLT as an off-hook signal. Va lu e Ra n g eINS: The card is in service. OUS: The card is out of service. Fault: The card has been removed from the slot, or is not communicating with the PBX. Fault-OVER: The number of CO line and/or extension ports exceed the system capacity. Fault-DIF: The card installed in the slot differs from the programmed card type. Pre-Install: There is no card in the slot, but the card type is programmed for the slot. Idle: There is no card in the slot, nor programming of the card type for the slot. Feature Guide References Feature References None Programming References 4.1.6 Slot [1-1] Card Command DefaultCurrent version number Va lu e Ra n g eVersion number Feature Guide References None DefaultNormal Va lu e Ra n g eNormal, Sweden, New Zealand Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1]
4.1 Configuration [1] Feature Guide 237 SLT Off Hook Guard Time Specifies the length of time used to prevent the PBX from mistaking an off-hook signal as a pulse dial. SLT Pulse Maximum Break Width Specifies the maximum length of the break signal in a pulse dial. SLT Pulse Minimum Make Width Specifies the minimum length of the make signal in a pulse dial. Default160 ms Va lu e Ra n g e8 × n (n=3–255) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default504 ms Va lu e Ra n g e8 × n (n=12–63) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default96 ms Va lu e Ra n g e8 × n (n=9–20) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default8 ms Va lu e Ra n g e8 × n (n=1–5) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1]
4.1 Configuration [1] 238 Feature Guide SLT Flash Detection Enables the PBX to detect a flash signal an SLT user sent by pressing the hookswitch or the Flash/Recall button. Flash Timing - Min. Specifies the minimum time before the PBX starts recognizing a hookswitch flash signal sent from an SLT. Flash Timing - Range Specifies the length of time required by the PBX to recognize a hookswitch flash signal sent from an SLT. DTMF-R STD Detection Time Specifies the minimum time required by the PBX to detect the DTMF tone. DefaultEnable Va lu e Ra n g eDisable: The PBX disconnects the line to prevent placing the call on hold. Enable: The PBX places the call on consultation hold. Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default112 ms Va lu e Ra n g e8 × n (n=3–63) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default904 ms Va lu e Ra n g e8 × n (n=3–191) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default30 ms Va lu e Ra n g e2 × n (n=1–31) ms
4.1 Configuration [1] Feature Guide 239 4.1.3 Slot [1-1] LCO Card Property The properties of the analog CO line cards can be specified. Outgoing Guard Time Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the line. First Dial Timer (CO) Specifies the minimum time that the PBX waits after seizing a CO line, before sending the dialed digits to the telephone company. This allows the telephone company to have enough time to accept the dialed digits correctly. CO Feed Back Tone Specifies whether to turn on or turn off the pulse feedback tone. For outgoing CO line calls, the dialed number is toned out, which informs the extension user that the dialed number has been dialed out. Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default3 s Va lu e Ra n g e3–6 s Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default1.0 s Va lu e Ra n g e0.5 × n (n=1–16) s Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] DefaultYe s Va lu e Ra n g eNo, Yes
4.1 Configuration [1] 240 Feature Guide Bell Detection—Bell Start Detection Timer Specifies the minimum time required by the PBX to confirm the bell signal sent from the telephone company, before the PBX detects an arriving call. Bell Detection—Bell Off Detection Timer Specifies the minimum time required by the PBX to confirm that the bell signal is no longer sent from the telephone company, before the PBX realizes the call is lost. Pulse / DTMF Dial—DTMF Inter Digit Pause Specifies the length of the DTMF inter-digit pause. This allows the telephone company to have enough time to accept the dialed digits correctly. Pulse / DTMF Dial—Pulse Inter Digit Pause Specifies the length of the pulse inter-digit pause. This allows the telephone company to have enough time to accept the dialed digits correctly. Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default144 ms Va lu e Ra n g e24 × n (n=1–50) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default6.0 s Va lu e Ra n g e1.0 s–15.0 s Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1] Default112 ms Va lu e Ra n g e16 × n (n=4–19) ms Feature Guide References Feature References None Programming References 4.1.1 Slot [1-1]