CHAPTER 2 ND-70182 (E) Page 66 Revision 4.0 PH-IO24 Input/Output Controller PH-IO24 Input/Output Controller 1. General Function The PH-IO24 (IOC) circuit card supplies the system with a serial interface, which conforms to RS-232C, between external equipment such as the Maintenance Administration Terminal (MAT), Station Message Detail Recording System (SMDR), Message Center Interface (MCI). Property Management System (PMS). The relationship between the IOC card and the associated cards is as follows, when the CPU is composed in a dual configuration. Note:Firmware SP-3290 IO24 LV2 PROG-A is required in the Hotel system for PMS and Hotel Printer. Figure 2-24 Location of PH-IO24 (IOC) Card within the System CPU BOARD #0 FDD/HDD #0 GT #1GT #0 MISC EMA MISC/IOCCPU I/OBOARD #1 MISC I/O BUS FDD/HDD #1 I/O IOC for Hotel IOC for Business MAT SMDR MCIPMS Hotel Printer
ND-70182 (E) CHAPTER 2 Page 67 Revision 4.0 PH-IO24 Input/Output Controller 2. Mounting Location/Condition The IOC cards can be accommodated in the shaded slots (02, 03) as shown below. Note:When using Business system and Hotel system, prepare the circuit card for each system. 3. Face Layout of Lamps, Switches and Connectors The face layout of lamps, switches and connectors on this circuit card is shown in Figure 2-25. Figure 2-25 Face Layout of PH-IO24 (IOC) Card LPMMounting Module 00 01 02 03 04 IOC #1 IOC #0 OPE IOC ALMMB PORT0 SW50 MBR PORT1 PORT2 PORT3
CHAPTER 2 ND-70182 (E) Page 68 Revision 4.0 PH-IO24 Input/Output Controller 4. Lamp Indications The table below shows lamp indications on this circuit card. 5. Switch Settings The following is a brief description of the switches on this circuit card. When a switch has a standard set- ting, it is indicated with “×” in the table below. LAMP NAME COLOR DESCRIPTION OPE/MB Green This circuit card is operating normally. Red This circuit card is placed in the make busy state. IOC ALM Red Clock down WDT alarm occurs to the microprocessor. PORT0 - PORT3 RS-232C signal status indication. n = port number (0-3) SDn Green SD:Send Data RDn Green RD:Receive Data ERn Green ER:Equipment Ready DRn Green DR:Data Ready CDn Green CD:Carrier Detect SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGDESCRIPTION MBUP The circuit card is placed into a make busy status. DOWN ×Cancellation of Make Busy. MBRUP The circuit card is placed into a make busy request status. DOWN ×Cancellation of Make Busy Request. SW501ON This circuit card is used as the extended I/O circuit card #1. OFF This circuit card is used as the extended I/O circuit card #0. 2ON Not used (For Business System Only). OFF × 2ON Free Wheeling with ACK signal (For Hotel System Only). OFF×Free Wheeling. 3ON Not used OFF × 4ON Not used OFF ×
ND-70182 (E) CHAPTER 2 Page 69 Revision 4.0 PH-IO24 Input/Output Controller 6. External Interface As illustrated below, the “68PH S 2PORTS CA-A” cable is required to connect external equipment such as the MAT, SMDR, MCI and PRT. Figure 2-26 External Cable Connection for PH-IO24 (IOC) Securely insert the connector of the 68PH S 2PORTS CA-A into the appropriate MISC connector. Refer to the table listed below. The relationship between the MISC connectors and the mounting slot of the IOC (PH-IO24) circuit card is shown below. The type of cables varies depending on a connected terminal and/or whether modems are used or not. More detailed information on the connecting cables is explained in the “Installation Procedure Manual”. MISC 3B/4B (Note 1) 68PH S 2PORTS CA-A Backplane PH-IO24 (IOC)Circuit #0 Circuit #1 Circuit #2 Circuit #3 RS-232C cable (Note 2) 68PH S 2PORTS CA-A MISC 3A/4A (Note 1) 17161514131211 ST210 ST109 RT08 PB/CI07 ER06 CD05 SG04 CS03 RS02 RD01 SDPin Signal name 4241403938373635343332313029282726Pin Signal nameTYP0, 1 Connector AMP AMP TYP0 TYP1 TYP1 TYP0 To RS-232C Terminal DR TYP0, 1 Lead Accommodation Note 1: Note 2: Mounting Slot 02 03IOC Circuit Number #0, #1 #2, #3 #0, #1 #2, #3MISC 3B MISC 3A MISC 4B MISC 4A MISC Connector
CHAPTER 2 ND-70182 (E) Page 70 Revision 4.0 PH-IO24 Input/Output Controller 7. Switch Setting Sheet SWITCH NAMESWITCH SHAPE REMARKS MB MBR SW50Meaning of SW50-1: ON: OFF:This card is used as the No. 1 circuit card. This card is used as the No. 0 circuit card. 1 ON 234
ND-70182 (E) CHAPTER 2 Page 71 Revision 4.0 PH-M22 MMC PH-M22 MMC 1. General Function The main functions of the PH-M22 circuit card are: To collect the key setting information on the TOPU of the ISW and send the information to the ISW/ the other LNs, depending on the ISEL key setting on the ISW. To collect various alarm information from all the IMGs/ISW and activate MJ/MN LED on the TOPU display. This circuit card is used for the IMX-U system. Figure 2-27 Location of PH-M22 (MMC) PZ-DK222 (TOP KEY) PH-PC40 PH-M22 EMA RELAY RECEIVER PZ-DK222 (TOP KEY) PH-PC40 PH-M22 EMA RELAY RECEIVER PZ-DK227 (TOP KEY) PH-PC40 PH-M22 EMA SEL RELAY RECEIVER ISEL ISW LN LN AUDIBLE AND VISUAL ALARM INDICATING PANEL KEY INFORMATION ALM INFORMATION
CHAPTER 2 ND-70182 (E) Page 72 Revision 4.0 PH-M22 MMC 2. Mounting Location/Condition This circuit card can be mounted in the shaded slots shown below. 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors are shown in Figure 2-28. Figure 2-28 Face Layout of PH-M22 (MMC) LPMMounting Module 00 01 02 03 04 MMCCPRAQ-A/CPRAS-A CPRAQ-A/CPRAS-A OPE MB CN7 CN6 CN5 CN4 CN3 CN2 CN1 CN0 KEY
ND-70182 (E) CHAPTER 2 Page 73 Revision 4.0 PH-M22 MMC 4. Lamp Indications The contents of lamp indications on this circuit card are shown in the table below. 5. Switch Settings Switch settings on this circuit card are shown in the table below. LAMP NAME COLOR STATE OPE Green Lights when this circuit card is in operation. SWITCH NAMESETTINGSTANDARD SETTINGMEANING MBUP Circuit Card make-busy DOWN×Circuit Card make-busy cancel
CHAPTER 2 ND-70182 (E) Page 74 Revision 4.0 PH-M22 MMC 6. External Interface Figure 2-29 Connection of Alarm Indicating Panel 01 02 03 04 05 01 02 03 04 05 1 2 3 4 5 6 7 8 9 10 11 12MPALM EXTAA BELAA - MNAA SUPAA MJAA 26 27 28 29 30 31 32 33 34 35 36 37 MNBA SUPBA MJBABELAA MNAA SUPAA MJAA MNBA SUPBA MJBA RPT1(G) RPT0(-48V)MDF MJ/MN/BELL -48V (RPT0)G (RPT1) AUDIBLE AND VISUAL ALARM INDICATING PANEL MDFMJ MN BELL (BASEU) LPM MISC0A Connector RPT Terminal on front of the BASEU REAR VIEW MMC (PH-M22) : Slot No.00 68PH EXMISC CA 68PH EXMISC CA and Installation Cable 68PH EXMISC CA
ND-70182 (E) CHAPTER 2 Page 75 Revision 4.0 PH-M22 MMC 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS MBNote:Normal operating mode is down.ON