    							CHAPTER 2 ND-70182 (E)
    Page 66
    Revision 4.0
    PH-IO24
    Input/Output Controller
    PH-IO24
    Input/Output Controller
    1. General Function
    The PH-IO24 (IOC) circuit card supplies the system with a serial interface, which conforms to RS-232C,
    between external equipment such as the Maintenance Administration Terminal (MAT), Station Message
    Detail Recording System (SMDR), Message Center Interface (MCI). Property Management System
    (PMS). The relationship between the IOC card and the associated cards is as follows, when the CPU is
    composed in a dual configuration.
    Note:Firmware SP-3290 IO24 LV2 PROG-A is required in the Hotel system for PMS and Hotel Printer.
    Figure 2-24   Location of PH-IO24 (IOC) Card within the System
    CPU
    BOARD
    #0
    FDD/HDD #0
    GT #1GT #0
    MISC
    EMA
    MISC/IOCCPU
    I/OBOARD
    #1
    MISC I/O BUS
    FDD/HDD #1 I/O
    IOC
     for 
    Hotel IOC
     for 
    Business
    MAT
    SMDR
    MCIPMS
    Hotel Printer 
    						
    							ND-70182 (E) CHAPTER 2
    Page 67
    Revision 4.0
    PH-IO24
    Input/Output Controller
    2. Mounting Location/Condition
    The IOC cards can be accommodated in the shaded slots (02, 03) as shown below.
    Note:When using Business system and Hotel system, prepare the circuit card for each system.
    3. Face Layout of Lamps, Switches and Connectors
    The face layout of lamps, switches and connectors on this circuit card is shown in Figure 2-25.
    Figure 2-25   Face Layout of PH-IO24 (IOC) Card
    LPMMounting Module
    00   01    02    03    04    
    IOC #1 IOC #0
    OPE
    IOC ALMMB
    PORT0
    SW50
    MBR
    PORT1
    PORT2
    PORT3 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 68
    Revision 4.0
    PH-IO24
    Input/Output Controller
    4. Lamp Indications
    The table below shows lamp indications on this circuit card.
    5. Switch Settings
    The following is a brief description of the switches on this circuit card. When a switch has a standard set-
    ting, it is indicated with “×” in the table below.
    LAMP NAME COLOR DESCRIPTION
    OPE/MB Green This circuit card is operating normally.
    Red This circuit card is placed in the make busy state.
    IOC ALM Red Clock down WDT alarm occurs to the microprocessor.
    PORT0 - PORT3 RS-232C signal status indication. n = port number (0-3)
    SDn Green SD:Send Data
    RDn Green RD:Receive Data
    ERn Green ER:Equipment Ready
    DRn Green DR:Data Ready
    CDn Green CD:Carrier Detect
    SWITCH
    NAMESWITCH
    NO.SETTINGSTANDARD
    SETTINGDESCRIPTION
    MBUP The circuit card is placed into a make busy status.
    DOWN
    ×Cancellation of Make Busy.
    MBRUP The circuit card is placed into a make busy request status.
    DOWN
    ×Cancellation of Make Busy Request.
    SW501ON This circuit card is used as the extended I/O circuit card #1.
    OFF This circuit card is used as the extended I/O circuit card #0.
    2ON
    Not used (For Business System Only).
    OFF
    ×
    2ON Free Wheeling with ACK signal (For Hotel System Only).
    OFF×Free Wheeling.
    3ON
    Not used
    OFF
    ×
    4ON
    Not used
    OFF
    × 
    						
    							ND-70182 (E) CHAPTER 2
    Page 69
    Revision 4.0
    PH-IO24
    Input/Output Controller
    6. External Interface
    As illustrated below, the “68PH S 2PORTS CA-A” cable is required to connect external equipment such as
    the MAT, SMDR, MCI and PRT.
    Figure 2-26   External Cable Connection for PH-IO24 (IOC)
     Securely insert the connector of the 68PH S 2PORTS CA-A into the appropriate MISC connector. Refer to the table listed below.
    The relationship between the MISC connectors and the mounting 
    slot of the IOC (PH-IO24) circuit card is shown below.
    The type of cables varies depending on a connected terminal and/or 
    whether modems are used or not. More detailed information on the 
    connecting cables is explained in the “Installation Procedure 
    Manual”.
    MISC 3B/4B (Note 1)
    68PH S 2PORTS CA-A Backplane
    PH-IO24
    (IOC)Circuit #0
    Circuit #1
    Circuit #2
    Circuit #3
    RS-232C cable (Note 2)
    68PH S 2PORTS CA-A
    MISC 3A/4A (Note 1)
    17161514131211
    ST210
    ST109
    RT08
    PB/CI07
    ER06
    CD05
    SG04 CS03 RS02 RD01 SDPin Signal name
    4241403938373635343332313029282726Pin Signal nameTYP0, 1 Connector 
    AMP
    AMP
    TYP0
    TYP1
    TYP1
    TYP0
    To RS-232C
    Terminal
    DR
    TYP0, 1 Lead Accommodation
    Note 1:
    Note 2:
    Mounting Slot
    02
    03IOC Circuit Number
    #0, #1
    #2, #3
    #0, #1
    #2, #3MISC 3B
    MISC 3A
    MISC 4B
    MISC 4A MISC Connector 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 70
    Revision 4.0
    PH-IO24
    Input/Output Controller
    7. Switch Setting Sheet
    SWITCH
    NAMESWITCH SHAPE REMARKS
    MB
    MBR
    SW50Meaning of SW50-1:
    ON:
    OFF:This card is used as the No. 1 circuit card.
    This card is used as the No. 0 circuit card.
    1
    ON
    234 
    						
    							ND-70182 (E) CHAPTER 2
    Page 71
    Revision 4.0
    PH-M22
    MMC
    PH-M22
    MMC
    1. General Function
    The main functions of the PH-M22 circuit card are:
    To collect the key setting information on the TOPU of the ISW and send the information to the ISW/
    the other LNs, depending on the ISEL key setting on the ISW.
    To collect various alarm information from all the IMGs/ISW and activate MJ/MN LED on the TOPU
    display.
    This circuit card is used for the IMX-U system.
    Figure 2-27   Location of PH-M22 (MMC)
    PZ-DK222
           (TOP KEY)
    PH-PC40 PH-M22
    EMA
    RELAY
    RECEIVER
    PZ-DK222
           (TOP KEY)
    PH-PC40 PH-M22
    EMA
    RELAY
    RECEIVER
    PZ-DK227
           (TOP KEY)
    PH-PC40 PH-M22
    EMA SEL
    RELAY
    RECEIVER
    ISEL ISW
    LN LN
    AUDIBLE
    AND
    VISUAL
    ALARM
    INDICATING
    PANEL
    KEY INFORMATION
    ALM INFORMATION 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 72
    Revision 4.0
    PH-M22
    MMC
    2. Mounting Location/Condition
    This circuit card can be mounted in the shaded slots shown below.
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors are shown in Figure 2-28.
    Figure 2-28   Face Layout of PH-M22 (MMC)
    LPMMounting Module
    00   01    02    03    04    
    MMCCPRAQ-A/CPRAS-A
    CPRAQ-A/CPRAS-A
    OPE
    MB
    CN7
    CN6
    CN5
    CN4
    CN3
    CN2
    CN1
    CN0
    KEY 
    						
    							ND-70182 (E) CHAPTER 2
    Page 73
    Revision 4.0
    PH-M22
    MMC
    4. Lamp Indications
    The contents of lamp indications on this circuit card are shown in the table below.
    5. Switch Settings
    Switch settings on this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    OPE Green Lights when this circuit card is in operation.
    SWITCH 
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    MBUP Circuit Card make-busy
    DOWN×Circuit Card make-busy cancel 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 74
    Revision 4.0
    PH-M22
    MMC
    6. External Interface
    Figure 2-29   Connection of Alarm Indicating Panel
    01 02 03 04 05 01 02 03 04 05
     1 
     2 
     3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12MPALM 
     
    EXTAA 
     
    BELAA 
    - 
    MNAA 
    SUPAA 
    MJAA 26 
     27 
     28 
     29 
     30 
     31 
     32 
     33 
     34 
     35 
     36 
     37 
     
    MNBA 
    SUPBA 
    MJBABELAA 
    MNAA 
    SUPAA 
    MJAA 
    MNBA 
    SUPBA 
    MJBA 
       RPT1(G) 
       RPT0(-48V)MDF
    MJ/MN/BELL -48V 
    (RPT0)G 
    (RPT1)
    AUDIBLE AND VISUAL 
    ALARM INDICATING PANEL
    MDFMJ 
    MN 
    BELL (BASEU) LPM
    MISC0A 
    Connector
    RPT Terminal on front 
    of the BASEU REAR VIEW
    MMC (PH-M22) : Slot No.00
    68PH EXMISC CA
    68PH EXMISC CA and 
    Installation Cable
    68PH EXMISC CA 
    						
    							ND-70182 (E) CHAPTER 2
    Page 75
    Revision 4.0
    PH-M22
    MMC
    7. Switch Setting Sheet
    SWITCH NAME SWITCH SHAPE REMARKS
    MBNote:Normal operating mode is down.ON 
    						