CHAPTER 2 ND-70182 (E) Page 126 Revision 4.0 PU-SW00 Time Division Switch 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS TSW MB TSW MBR ON ON
ND-70182 (E) CHAPTER 2 Page 127 Revision 4.0 PU-SW01 Highway Switch PU-SW01 Highway Switch 1. General Function The PU-SW01 circuit card, which is used for the IMX-U system, supports the following functions. (a) The switch composition is T-T-S-T (T: Time division, S: Space division, T: Time division), and the space division is composed with this circuit card. (b) This circuit card collects the 16 highways of PCM data from and sends 8 highways to TSW by one card. It is used to perform 16 highways switching by 2 PU-SW01 cards. Figure 2-61 Location of PU-SW01 (HSW) (1/2) MUX00 LC/TRK LC/TRK LC/TRK LC/TRK DLKC0 LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK LC/TRK MUX01 MUX02 MUX03 MUX10 MUX11 MUX12 MUX13 TSW00 TSW10 TSW01 TSW11 TSW02 TSW12 TSW03 TSW13 PLO 0 PLO 0 DLKC1 PLO 1 PLO 1 MUX MUX TSW00 TSW01 TSW02 TSW03HSW00 HSW01HSW10 HSW11TSW10 TSW11 TSW12 TSW13 2M PCM HW x8 2M PCM HW x8 2M PCM HW x8 2M PCM HW x82M PCM HW x8 2M PCM HW x8 2M PCM HW x8 2M PCM HW x8 32M TSW Matrix HW32M SERIAL HW 32M SERIAL HW x4 32M SERIAL HW x432M SERIAL HW x4 32M SERIAL HW x4 64KHz Clock 64KHz Clock32M TSW Matrix HW 32.768MHz Clock DCS 32.768MHz Clock DCS 32.768MHz Clock 32.768MHz Clock TSW Configuration
CHAPTER 2 ND-70182 (E) Page 128 Revision 4.0 PU-SW01 Highway Switch Figure 2-61 Location of PU-SW01 (HSW) (2/2) HSW01 HSW00 TSW03 TSW02 TSW01 TSW00 LANI LANI LANI LANI HSW11 HSW10 TSW13 TSW12 TSW11 TSW10 PLO 1 PLO 0 RES CPUCPU MISC IOC EMARES RESRES IOGT1 IOGT0 ISAGTISAGT MISC I/O BUSISAGT BUS ISAGT BUSLPM TSW I/O BUS TSW I/O BUSISWM [INT Configuration]
ND-70182 (E) CHAPTER 2 Page 129 Revision 4.0 PU-SW01 Highway Switch 2. Mounting Location/Condition This circuit card is mounted in ISWM located in the ISW. The mounted slots are the shaded parts shown below. 3. Face Layout of lamps, Switches, and Connectors The face layout of lamps, switches, and connectors are shown in Figure 2-62. Figure 2-62 Face Layout of PU-SW01 (HSW) 00 01 0203 04 05 06 07 08 09 10 11 12 13 14 15 16 171819 Mounting ModuleISWM HSW (00) HSW (01) HSW (10) HSW (11) MB HSWACT PWRALM CKALF CKALE CKALD CKALC CKALB CKALA CKAL9 CKAL8 CKAL7 CKAL6 CKAL5 CKAL4 CKAL3 CKAL2 CKAL1 CKAL0
CHAPTER 2 ND-70182 (E) Page 130 Revision 4.0 PU-SW01 Highway Switch 4. Lamp Indications Lamp indications for this circuit card are shown in the table below. LAMP NAME COLOR STATE HSWACTGreen Lights when the HSW block is active. Red Lights when the HSW block is in Make-busy state. PWPALM Red Lights when the On-Board Power Supply (-48 V) for this circuit card is abnormal. CKALFGreen Lights when the clock/Frame Head signals are sent from #15 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #15 circuit of TSW in ISW. CKALEGreen Lights when the clock/Frame Head signals are sent from #14 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #14 circuit of TSW in ISW. CKALDGreen Lights when the clock/Frame Head signals are sent from #13 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #13 circuit of TSW in ISW. CKALCGreen Lights when the clock/Frame Head signals are sent from #12 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #12 circuit of TSW in ISW. CKALBGreen Lights when the clock/Frame Head signals are sent from #11 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #11 circuit of TSW in ISW. CKALAGreen Lights when the clock/Frame Head signals are sent from #10 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #10 circuit of TSW in ISW. CKAL9Green Lights when the clock/Frame Head signals are sent from #09 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #09 circuit of TSW in ISW. CKAL8Green Lights when the clock/Frame Head signals are sent from #08 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #08 circuit of TSW in ISW. CKAL7Green Lights when the clock/Frame Head signals are sent from #07 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #07 circuit of TSW in ISW. CKAL6Green Lights when the clock/Frame Head signals are sent from #06 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #06 circuit of TSW in ISW. CKAL5Green Lights when the clock/Frame Head signals are sent from #05 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #05 circuit of TSW in ISW. CKAL4Green Lights when the clock/Frame Head signals are sent from #04 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #04 circuit of TSW in ISW.
ND-70182 (E) CHAPTER 2 Page 131 Revision 4.0 PU-SW01 Highway Switch 5. Switch Settings Switch settings on this circuit card are shown in the table below. 6. External Interface No cable connections are required. 7. Switch Setting Sheet CKAL3Green Lights when the clock signal is sent normally from #03 circuit of TSW in ISW. Off Goes off when the clock failure occurs on #03 circuit of TSW in ISW. CKAL2Green Lights when the clock/Frame Head signals are sent from #02 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #02 circuit of TSW in ISW. CKAL1Green Lights when the clock/Frame Head signals are sent from #01 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #01 circuit of TSW in ISW. CKAL0Green Lights when the clock/Frame Head signals are sent from #00 circuit of TSW in ISW. Off Goes off when the clock/Frame Head signals are not sent from #00 circuit of TSW in ISW. SWITCH NAMESETTINGSTANDARD SETTINGMEANING MBUP Circuit card Make-busy. DOWN×Circuit card Make-busy cancel. SWITCH NAME SWITCH SHAPE REMARKS MB LAMP NAME COLOR STATE ON
CHAPTER 2 ND-70182 (E) Page 132 Revision 4.0 PZ-GT13 Industrial Standard Architecture Gateway PZ-GT13 Industrial Standard Architecture Gateway 1. General Function The PZ-GT13 (ISAGT) circuit card controls the TSDW, DLKC, PLO etc. using the PH-GT09 (GT) in the TSWM. This card also provides the MISC I/O bus interface, which permits a microprocessor on the CPR to control EMA and IOC/MISC. The Industrial Standard Architecture (ISA) bus is used to connect this circuit card onto the CPR. Figure 2-63 Location of PZ-GT13 (ISAGT) PLO0 PLO1 TSW03 TDSW I/O Local BusTDSW I/O Local Bus TSW13 TSW02 TSW12 TSW01 TSW11 TSW00 DLKC0 MISC ISAGT DSP CPULANI LANI GT TSW10 CPR #0 To HUB To HUBTo HUB To HUB ISAGTGTDLKC1 DSP CPU CPR #1LANI LANI EMA IOC/ MISC MISC I/O Bus MISC I/O Bus
ND-70182 (E) CHAPTER 2 Page 133 Revision 4.0 PZ-GT13 Industrial Standard Architecture Gateway Figure 2-64 Location of PZ-GT13 (ISAGT) in the IMX-U System (ISW) 2. Mounting Location/Condition The PZ-GT13 is located on the ISA bus, which is allocated in the CPR as shown below. HSW01 HSW00 TSW03 TSW02 TSW01 TSW00 LANI LANI LANI LANI HSW11 HSW10 TSW13 TSW12 TSW11 TSW10 PLO 1 PLO 0 RES CPUCPU MISC IOC EMARES RESRES (IOGT1) PH-GT10 (IOGT0) PH-GT10 (ISAGT) PZ-GT13(ISAGT) PZ-GT13 MISC I/O BUSISAGT BUS ISAGT BUSLPM TSW I/O BUS TSW I/O BUSISWM PZ-GT13 (ISAGT) CPU BOARD PZ-DK224 (DSP) PZ-PC19 (LANI) PZ-PW92 (PWR) PZ-IO27 (FDD/HDD) LPMMounting Module
CHAPTER 2 ND-70182 (E) Page 134 Revision 4.0 PZ-GT13 Industrial Standard Architecture Gateway 3. Face Layout of Connectors The face layout of connectors is shown Figure 2-65. Neither lamps nor switches are located on this circuit card. Figure 2-65 Face Layout of PZ-GT13 (ISAGT) 4. External Interface This card has no lamps. 5. Switch Settings No switch settings are required. 6. External Interface See the NEAX2400 IMX Installation Manual. 7. Switch Setting Sheet No switch settings are required. ISA BUS INTERFACE FRONT VIEW PWG DSPP CONN AB
ND-70182 (E) CHAPTER 2 Page 135 Revision 4.0 PZ-GT16 Industrial Standard Architecture Gateway PZ-GT16 Industrial Standard Architecture Gateway 1. General Function The PZ-GT16 (ISAGT) circuit card provides both the I/O Local bus and the MISC bus interface, which permits a microprocessor on the CPR to control the lower echelons of circuit cards. The Industrial Standard Architecture (ISA) bus is used to connect this circuit card onto the CPR. Figure 2-66 Location of PZ-GT16 (ISAGT) DSP CPU LANI LANI CPR#0 DSP ISAGTCPU LANI LANI EMA IOC/ MISC TSWTSW To HUBTo HUB To HUBTo HUB I/O Local BusI/O Local Bus CPR#1 MISC BusMISC Bus ISAGT