CHAPTER 3 ND-70182 (E) Page 166 Revision 4.0 PH-CK16-A Phase Lock Oscillator PH-CK16-A Phase Lock Oscillator 1. General Function This circuit card, used together with a direct digital interface circuit card, sets up network synchronization. With this circuit card, the system can be a clock subordinate office of the digital network. As seen in the figure below, the PLO can be redundant regardless of the system switching network selection. This circuit card is used for the IMX-U system.
ND-70182 (E) CHAPTER 3 Page 167 Revision 4.0 PH-CK16-A Phase Lock Oscillator Figure 3-10 Location of PH-CK16-A (PLO) LN0 (IMG2/IMG3)LN3 (IMG2/IMG3) 32M, FH+WFH PLO ACT32M, FH+WFH PLO ACT CLK1 (TSWM1) TSW 10~13 CLK0 (TSWM1) TSW 00~03 MUX (System1)MUX (System0) LC/TRK HSW00 ISW HSW01 CLK1 (TSWM1) TSW 10~13 CLK0 (TSWM1) TSW 00~03 MUX (System1)MUX (System0) LC/TRK LN0 (IMG0/IMG1)from LN DTIfrom LN DTI 32M, FH+WFH PLO ACT32M, FH+WFH PLO ACT (BWB)32M, FH+WFH PLO ACT (BWB) 64K+FH, WFH TSW ACT (Cable)64K+FH, WFH TSW ACT (Cable) PLO 1 (TSWM0) TSW 10~13 PLO 0 (TSWM0) TSW 00~03 MUX (System1)MUX (System0) LC/TRK LN3 (IMG0/IMG1) 32M, FH+WFH PLO ACT PLO 1 (TSWM0) TSW 10~13 PLO 0 (TSWM0) TSW 00~03 MUX (System1)MUX (System0) LC/TRK TSW00 TSW03HSW10 OSC64K+8K (BWB) (BWB) CLK, FH, WFH ACT, ALM PLO 0 DTI0 DCS0 (MDF) DCS1123 PLO 1 SEL PLL Drv HSW11 TSW10 TSW13 SEL PLL Drv OSC ~ ~~ ~
CHAPTER 3 ND-70182 (E) Page 168 Revision 4.0 PH-CK16-A Phase Lock Oscillator 2. Mounting Location/Condition This circuit card can be mounted in the shaded slots shown below. Mounting ModuleISWM 00 01 02 03 04 05 06 07 0809 10 11 1213 14 15 16 17 18 19 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 2021 2223 PLO (#0) PLO (#1) Mounting ModuleTSWM0 (IMG1) PLO (#0) PLO (#1)
ND-70182 (E) CHAPTER 3 Page 169 Revision 4.0 PH-CK16-A Phase Lock Oscillator 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors are shown in Figure 3-11. Figure 3-11 Face Layout of PH-CK16-A (PLO) 1 2 3 4 1 2 SW11 SW10SW12 MB OPE 1 2 3 4 5 6 7 8 MJ MN SYNC ICK CKPKG ALM0 ALM1 PALM SW01 SW02 SW03 12345678 12345678
CHAPTER 3 ND-70182 (E) Page 170 Revision 4.0 PH-CK16-A Phase Lock Oscillator 4. Lamp Indications Lamp indications for this circuit card are shown in the table below: Note:This lamp is effective when this card is mounted in TSWM0 of the IMX-U system. 5. Switch Settings Standard settings for switches on this circuit card are shown in the table below. LAMP NAME COLOR STATE OPE Green Remains lit while this circuit card is in active state. MJ RedLights when the following MJ fault has occurred: All of the clock supply routes have failed when the system operates as the clock subordinate office 32.768 MHz output clock failure (including CLK card) 8 KHz output clock failure (including CLK card) Input Frame Pulse (FP) failure (FP is supplied by the SYNC card) Internal OSC (±5 ppm deviation) has failed when the system operates as the clock source office MN RedLights when the following MN fault has occurred: One or more (but not all) DTI/DCS clock supply route has failed Drifting failure Internal OSC (±5 ppm deviation) failure SYNC Green Remains lit while the system is synchronized with the network. ICK Green Lights when the internal oscillator is operating normally. CKPKG NoteGreen Lights when the CLK card in TSWM1 is in normal operation. ALM0 NoteRed Lights when clock failure has occurred in the CLK card. ALM1 NoteRed Lights when FH failure has occurred in the CLK card. PALM Red Remains lit when the On-Board Power Supply is abnormal. SWITCH NAMESETTINGSTANDARD SETTINGMEANING MBUP Circuit card Make-busy. DOWN×Circuit card Make-busy cancel. SW03 1 - F 1 Fixed to “1.
ND-70182 (E) CHAPTER 3 Page 171 Revision 4.0 PH-CK16-A Phase Lock Oscillator Note: When this card is used in the 4-IMG or ISWM of the IMX-U system, specify the clock source (DCS or DTI) according to the clock network configuration for the office. Note 1:This standard setting is applicable when this card is mounted in TSWM0 of the IMX-U system. SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW01 Note1ON × Note 1Clock subordinate office. OFF Clock source office. 2ON × Note 1Digital Clock Supply route zero (DCS 0) is used. OFF Digital Clock Supply route zero (DCS 0) is not used. 3ON × Note 1Digital Clock Supply route one (DCS 1) is used. OFF Digital Clock Supply route one (DCS 1) is not used. 4ON8 KHz of Frame Head signals are extracted from the DCS sig- nals (which is composed of 64 KHz + 8 KHz). OFF × Note 18 KHz of Frame Head signals are not extracted from the DCS signals (which is composed of 64 KHz + 8 KHz). 5ONWhen clock source failure has occurred in all supply routes, the PLO outputs the original clock of the internal oscillator. OFF×When clock source failure has not occurred, the PLO keeps on outputting the current phase clock. 6ON × Note 1T h i s c i r c u i t c a r d i s associated with SYNC (PA-CK11) card. OFFThis circuit card is not associated with SYNC (PA-CK16 WCS) card. 7ON A-law CODEC is used for Music-on-Hold. OFF×µ-law CODEC is used for Music-on-Hold. 8OFF ×Fixed OFF (Not used).
CHAPTER 3 ND-70182 (E) Page 172 Revision 4.0 PH-CK16-A Phase Lock Oscillator Note: When this card is mounted in TSWM0 of the IMX-U system, the DCS clock from the ISW is used. The DTI clock can also be used as an alternate clock supply route in case of DCS clock failure. SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW02 Note1ON DIU 0 is used as the DTI clock supply route zero. OFF DIU 0 is not used. 2ON DIU 1 is used as the DTI clock supply route one. OFF DIU 1 is not used. 3ON DIU 2 is used as the DTI clock supply route two. OFF DIU 2 is not used. 4ON DIU 3 is used as the DTI clock supply route three. OFF DIU 3 is not used. 5ON×1.5 M clock for DIU 0. OFF 2 M clock for DIU 0. 6ON×1.5 M clock for DIU 1. OFF 2 M clock for DIU 1. 7ON×1.5 M clock for DIU 2. OFF 2 M clock for DIU 2. 8ON×1.5 M clock for DIU 3. OFF 2 M clock for DIU 3. SW101ON External hold tone source is used via FM lead. OFF×MUSIC ROM is used as the hold tone. 2ON CLK card is not used. OFF CLK card is used.
ND-70182 (E) CHAPTER 3 Page 173 Revision 4.0 PH-CK16-A Phase Lock Oscillator SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW111 2 3 4 SW121 2 3 4ON Not used OFF×Not used 5 MUSIC (CH1) selection. The music varies depending on the melody IC located on this circuit card. 6 7 8ON Not used OFF×Not used SW11-1 SW11-2Impedance of the External Music Source 0 (FM 0) OFF OFF 600 Ω ON OFF 8.2 Ω OFF ON 47K Ω SW11-3 SW11-4Impedance of the External Music Source 1 (FM 1) OFF OFF 600 Ω ON OFF 8.2 Ω OFF ON 47K Ω SW12-1 SW12-2 SW12-3 MUSIC OFF OFF OFF Für Elise ON OFF OFF Maiden’s prayer Not Used ON OFF Buzzer Not Used OFF ON Chime
CHAPTER 3 ND-70182 (E) Page 174 Revision 4.0 PH-CK16-A Phase Lock Oscillator 6. External Interface PLO leads appear on the LT connectors labeled EXCLK0 and EXCLK1. PLO mounting slots The PLO card is mounted in Slots 21 and 23 of TSWM. LT cable connectors Connect the LT cables to the connectors labeled EXCLK0 and EXCLK1 on the TSWM backplane. Figure 3-12 PLO Pin Assignments for Receiving Clock (4 IMG System) (1/2) 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 EXCLK0EXCLK1 PLO PLO TSW Front View TSWM EXCLK0EXCLK1 TSWMBackplane
ND-70182 (E) CHAPTER 3 Page 175 Revision 4.0 PH-CK16-A Phase Lock Oscillator EXCLK0/EXCLK1 connector Pin Assignment Pins are assigned as follows on the EXCLK0/EXCLK1 connectors. When the clock is distributed from a digital interface, use one pair of DIUxxx in one of the 4 inputs. (There are a maximum of 4 inputs.) DIU leads have the following precedence: DIU0xx (high) ➝ DIU3xx (low). Figure 3-12 PLO Pin Assignments for Receiving Clock (4 IMG System) (2/2) PLO input leads appear on the LT connectors labeled EXCLK0 and EXCLK1. PLO mounting slots The PLO card is mounted in Slots 09 and 13 of ISWM. 34PH ISWM EXCLK CA-A 34PH ISWM EXCLK CA-A REAR VIEW EXCLK0EXCLK1TSWM MDF Installation Cable To Digital Interface and/or DCS 34PH ISWM EXCLK CA-A Cable Lead Location 26 27 28 29 30 31 32 33 34 35 36 37 381 2 3 4 5 6 7 8 9 10 11 12 13 FM1 FM0 DIU3B DIU2B DIU1B DIU0B DCSB SYN1B SYN0BE E DIU3A DIU2A DIU1A DIU0A DCSA SYN1A SYN0A 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 23EXCLK0EXCLK1 PLO PLO Front View ISWM