CHAPTER 3 ND-70182 (E) Page 186 Revision 4.0 PH-CK17 Phase Lock Oscillator 4. Lamp Indications Lamp indications for this circuit card are shown in the table below. LAMP NAME COLOR STATE AC TGreen Remains lit while this circuit card is in active state. Off Remains off while this circuit card is in stand-by state. MJ RedLights when the following MJ fault has occurred: All of the clock supply routes have failed when the system operates as the clock subordinate office. 32.768 MHz output clock failure. 8 KHz output FH failure. 5 msec × “n” output FH failure. Input Frame Pulse (FP) failure (FP is supplied by the SYNC card). Internal OSC (±0.3 ppm deviation) has failed when the system operates as the clock source office. MN RedLights when the following MN fault has occurred: One or more (but not all) DTI/DCS clock supply routes failed. Drifting failure. Internal OSC (±0.3 ppm deviation) failure. SYNCGreen Remains lit while the system is synchronized with the network. OFFRemains off when either of the following has occurred. DCS clock failure when receiving the clock signals from the DCS. DTI clock failure when receiving the clock signals from the DTI. Drifting failure. ICK Green Lights when the internal oscillator is operating normally. PALM Red Remains lit when power is abnormal.
ND-70182 (E) CHAPTER 3 Page 187 Revision 4.0 PH-CK17 Phase Lock Oscillator 5. Switch Settings Standard settings for switches on this circuit card are shown in the table below. SWITCH NAMESETTINGSTANDARD SETTINGMEANING MBUP Circuit card Make-busy. DOWN×Circuit card Make-busy cancel. SW03 1 - F 1 Fixed to “1.” SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW011ON Clock subordinate office. OFF Clock source office. 2ON Digital Clock Supply route zero (DCS 0) is used. OFF Digital Clock Supply route zero (DCS 0) is not used. 3ON Digital Clock Supply route one (DCS 1) is used. OFF Digital Clock Supply route one (DCS 1) is not used. 4ON8 KHz of Frame Head signals are not extracted from the DCS signals (which is composed of 64 KHz + 8 KHz). OFF8 KHz of Frame Head signals are extracted from the DCS sig- nals (which is composed of 64 KHz + 8 KHz). 5ONWhen clock source failure has occurred in all supply routes, the PLO outputs the original clock of the internal oscillator. OFFWhen clock source failure has occurred in all supply routes, the PLO continues outputting the current phase clock. 6ON This circuit card is associated with SYNC (PA-CK11) card. OFFThis circuit card is not associated with SYNC (PA-CK11) card. 7ON A-law CODEC is used for the hold music. OFF×µ-law CODEC is used for the hold music. 8OFF ×Not used
CHAPTER 3 ND-70182 (E) Page 188 Revision 4.0 PH-CK17 Phase Lock Oscillator SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW021ON DIU 0 is used as the DTI clock supply route zero. OFF DIU 0 is not used. 2ON DIU 1 is used as the DTI clock supply route one. OFF DIU 1 is not used. 3ON DIU 2 is used as the DTI clock supply route two. OFF DIU 2 is not used. 4ON DIU 3 is used as the DTI clock supply route three. OFF DIU 3 is not used. 5ON×1.5 M clock for DIU 0 OFF 2 M clock for DIU 0 6ON×1.5 M clock for DIU 1 OFF 2 M clock for DIU 1 7ON×1.5 M clock for DIU 2 OFF 2 M clock for DIU 2 8ON×1.5 M clock for DIU 3 OFF 2 M clock for DIU 3 SW051ON External hold tone source is used via FM lead. OFF×MUSIC ROM is used as the hold tone. 2OFF Not used SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW061 2 3 4 SW8F-1 SW8F-2Impedance of the External Music Source 0 (FM 0) OFF OFF 600 Ω ON OFF 8.2 Ω OFF ON 47K Ω SW8F-3 SW8F-4Impedance of the External Music Source 1 (FM 1) OFF OFF 600 Ω ON OFF 8.2 Ω OFF ON 47K Ω
ND-70182 (E) CHAPTER 3 Page 189 Revision 4.0 PH-CK17 Phase Lock Oscillator SW041 2 3 4ON Not used OFF×Not used 5 MUSIC CH1 selection. The kind of music varies depending on the melody IC located on this circuit card. 6 7 8ON Not used OFF×Not used SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SWA0-1 SWA0-2 SWA0-3 MUSIC OFF OFF OFF Für Elise ON OFF OFF Maiden’s prayer Not Used OFF ON Buzzer Not Used ON OFF Chime
CHAPTER 3 ND-70182 (E) Page 190 Revision 4.0 PH-CK17 Phase Lock Oscillator 6. External Interface When this circuit card is located in the TSWM, connect 34PH EXCLK CA-A to the EXCLK0/EXCLK1 connectors on the backplane of the TSWM. Figure 3-22 LT Connector Lead Location of PLO (TSWM) 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23Slot No. TSWM FRONT VIEW PLO #1 PLO #0 26 1 FM 1 27 2 FM 0 28 3 SYN 1BE 29 4 SYN 0BE 30 5 DIU 3BSYN 1A 31 6 DIU 2BSYN 0A 32 7 DIU 1BDIU 3A 33 8 DIU 0BDIU 2A 34 9 DCS BDIU 1A 35 10 DIU 0A 36 11 DCS A 37 12 38 13 EXCLK0 (Slot No.21) EXCLK1 (Slot No.23)TSWMREAR VIEW 34PH EXCLK CA-A 34PH EXCLK CA-A34PH EXCLK CA-A LEAD ACCOMMODATION Installation Cable MDF To Digital Interface and/or DCS Mounting ModuleTSWM
ND-70182 (E) CHAPTER 3 Page 191 Revision 4.0 PH-CK17 Phase Lock Oscillator Figure 3-23 Connecting Route Diagram DCSB1 DIU0A1 DIU0B1 DIU1A1 DIU1B1 DIU2A1 DIU2B1 DIU3A1 DIU3B1 DCSA1 DCSB0 DIU0A0 DIU0B0 DIU1A0 DIU1B0 DIU2A0 DIU2B0 DIU3A0 DIU3B0 DCSA0 POUT B POUT A POUT B POUT A POUT B POUT A POUT B POUT A CCT /DTI /PRT CCT /DTI /PRT CCT /DTI /PRT CCT /DTI /PRT PLO #0 PLO #1 DCS Note : The following circuit cards have Clock Output Leads for a PLO card: CCT (PA-24CCTA, PA-30CCTB), DTI (PA-24DTR, PA-30DTS), and PRT (PA-24PRT, PA-30PRTC). MDF PBX
CHAPTER 3 ND-70182 (E) Page 192 Revision 4.0 PH-CK17 Phase Lock Oscillator 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS MB SW01 SW02 SW03 SW05 SW06 SW04 ON 1234ON5678 1234ON5678 12ON 1234ON 1234ON5678
ND-70182 (E) CHAPTER 3 Page 193 Revision 4.0 PH-CK17-A Phase Lock Oscillator PH-CK17-A Phase Lock Oscillator 1. General Function This circuit card used together with a direct digital interface circuit card, sets up network synchronization between networks. Since this circuit card provides a high precision base clock oscillator, the system containing this circuit card can be a clock source office of the digital network. As seen in the figure below, the PLO can be redundant regardless of the system switching network selection. This circuit card is used for the IMX-U system. Figure 3-24 Location of PH-CK17-A (PLO) LN0 (IMG2/IMG3)LN3 (IMG2/IMG3) 32M, FH+WFH PLO ACT32M, FH+WFH PLO ACT CLK1 (TSWM1) TSW 10~13 CLK0 (TSWM1) TSW 00~03 MUX (System1)MUX (System0) LC/TRK HSW00 ISW HSW01 CLK1 (TSWM1) TSW 10~13 CLK0 (TSWM1) TSW 00~03 MUX (System1)MUX (System0) LC/TRK LN0 (IMG0/IMG1)from LN DTIfrom LN DTI 32M, FH+WFH PLO ACT32M, FH+WFH PLO ACT (BWB)32M, FH+WFH PLO ACT (BWB) 64K+FH, WFH TSW ACT (Cable)64K+FH, WFH TSW ACT (Cable) PLO 1 (TSWM0) TSW 10~13 PLO 0 (TSWM0) TSW 00~03 MUX (System1)MUX (System0) LC/TRK LN3 (IMG0/IMG1) 32M, FH+WFH PLO ACT PLO 1 (TSWM0) TSW 10~13 PLO 0 (TSWM0) TSW 00~03 MUX (System1)MUX (System0) LC/TRK TSW00 TSW03HSW10 OSC64K+8K (BWB) (BWB) CLK, FH, WFH ACT, ALM PLO 0 DTI0 DCS0 (MDF) DCS1123 PLO 1 SEL PLL Drv HSW11 TSW10 TSW13 SEL PLL Drv OSC ~ ~~ ~
CHAPTER 3 ND-70182 (E) Page 194 Revision 4.0 PH-CK17-A Phase Lock Oscillator 2. Mounting Location/Condition This circuit card can be mounted in the shaded slots shown below. Mounting ModuleISWM 00 01 02 03 04 05 06 070809 10 111213 14 15 16 17 18 19 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 1920212223 PLO (#0) PLO (#1) Mounting ModuleTSWM0 (IMG1) PLO (#0) PLO (#1)
ND-70182 (E) CHAPTER 3 Page 195 Revision 4.0 PH-CK17-A Phase Lock Oscillator 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors are shown in Figure 3-25 Figure 3-25 Face Layout of PH-CK17-A (PLO) 1 2 3 4 1 2 SW11 SW10SW12 MB OPE 1 2 3 4 5 6 7 8 SW01 SW02 SW03 12345678 12345678 MJ MN SYNC ICK CKPKG ALM0 ALM1 PALM