    							CHAPTER 3 ND-70182 (E)
    Page 186
    Revision 4.0
    PH-CK17
    Phase Lock Oscillator
    4. Lamp Indications
    Lamp indications for this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    AC TGreen Remains lit while this circuit card is in active state.
    Off Remains off while this circuit card is in stand-by state.
    MJ RedLights when the following MJ fault has occurred:
    All of the clock supply routes have failed when the system operates as the clock 
    subordinate office.
    32.768 MHz output clock failure.
    8 KHz output FH failure.
    5 msec ×  “n” output FH failure.
    Input Frame Pulse (FP) failure (FP is supplied by the SYNC card).
    Internal OSC (±0.3 ppm deviation) has failed when the system operates as the 
    clock source office.
    MN RedLights when the following MN fault has occurred: 
    One or more (but not all) DTI/DCS clock supply routes failed.
    Drifting failure.
    Internal OSC (±0.3 ppm deviation) failure.
    SYNCGreen Remains lit while the system is synchronized with the network.
    OFFRemains off when either of the following has occurred. 
    DCS clock failure when receiving the clock signals from the DCS. 
    DTI clock failure when receiving the clock signals from the DTI. 
    Drifting failure.
    ICK Green Lights when the internal oscillator is operating normally. 
    PALM Red Remains lit when power is abnormal. 
    						
    							ND-70182 (E) CHAPTER 3
    Page 187
    Revision 4.0
    PH-CK17
    Phase Lock Oscillator
    5. Switch Settings
    Standard settings for switches on this circuit card are shown in the table below.
    SWITCH 
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    MBUP Circuit card Make-busy.
    DOWN×Circuit card Make-busy cancel.
    SW03 1 - F 1 Fixed to “1.”
    SWITCH 
    NAMESWITCH
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    SW011ON Clock subordinate office.
    OFF Clock source office.
    2ON Digital Clock Supply route zero (DCS 0) is used.
    OFF Digital Clock Supply route zero (DCS 0) is not used.
    3ON Digital Clock Supply route one (DCS 1) is used.
    OFF Digital Clock Supply route one (DCS 1) is not used.
    4ON8 KHz of Frame Head signals are not extracted from the DCS 
    signals (which is composed of 64 KHz + 8 KHz).
    OFF8 KHz of Frame Head signals are extracted from the DCS sig-
    nals (which is composed of 64 KHz + 8 KHz).
    5ONWhen clock source failure has occurred in all supply routes, 
    the PLO outputs the original clock of the internal oscillator.
    OFFWhen clock source failure has occurred in all supply routes, 
    the PLO continues outputting the current phase clock.
    6ON This circuit card is associated with SYNC (PA-CK11) card.
    OFFThis circuit card is not associated with SYNC (PA-CK11) 
    card.
    7ON A-law CODEC is used for the hold music.
    OFF×µ-law CODEC is used for the hold music.
    8OFF ×Not used 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 188
    Revision 4.0
    PH-CK17
    Phase Lock Oscillator
    SWITCH 
    NAMESWITCH
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    SW021ON DIU 0 is used as the DTI clock supply route zero.
    OFF DIU 0 is not used.
    2ON DIU 1 is used as the DTI clock supply route one.
    OFF DIU 1 is not used.
    3ON DIU 2 is used as the DTI clock supply route two.
    OFF DIU 2 is not used.
    4ON DIU 3 is used as the DTI clock supply route three.
    OFF DIU 3 is not used.
    5ON×1.5 M clock for DIU 0
    OFF 2 M clock for DIU 0
    6ON×1.5 M clock for DIU 1
    OFF 2 M clock for DIU 1
    7ON×1.5 M clock for DIU 2
    OFF 2 M clock for DIU 2
    8ON×1.5 M clock for DIU 3
    OFF 2 M clock for DIU 3
    SW051ON  External hold tone source is used via FM lead.
    OFF×MUSIC ROM is used as the hold tone.
    2OFF Not used
    SWITCH 
    NAMESWITCH
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    SW061
    2
    3
    4
    SW8F-1 SW8F-2Impedance of the External 
    Music Source 0 (FM 0)
    OFF OFF 600 Ω
    ON OFF 8.2 Ω
    OFF ON 47K Ω
    SW8F-3 SW8F-4Impedance of the External 
    Music Source 1 (FM 1)
    OFF OFF 600 Ω
    ON OFF 8.2 Ω
    OFF ON 47K Ω 
    						
    							ND-70182 (E) CHAPTER 3
    Page 189
    Revision 4.0
    PH-CK17
    Phase Lock Oscillator
    SW041
    2
    3
    4ON Not used
    OFF×Not used
    5
    MUSIC CH1 selection. The kind of music varies depending on the melody IC  located on this 
    circuit card. 6
    7
    8ON Not used
    OFF×Not used SWITCH 
    NAMESWITCH
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    SWA0-1 SWA0-2 SWA0-3 MUSIC
    OFF OFF OFF Für Elise
    ON OFF OFF Maiden’s prayer
    Not Used OFF ON Buzzer
    Not Used ON OFF Chime 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 190
    Revision 4.0
    PH-CK17
    Phase Lock Oscillator
    6. External Interface
    When this circuit card is located in the TSWM, connect 34PH EXCLK CA-A to the EXCLK0/EXCLK1
    connectors on the backplane of the TSWM.
    Figure 3-22   LT Connector Lead Location of PLO (TSWM)
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23Slot No.
    TSWM
    FRONT VIEW
    PLO #1
    PLO #0
    26 1
    FM 1 27 2
    FM 0 28 3
    SYN 1BE
    29 4
    SYN 0BE
    30 5
    DIU 3BSYN 1A
    31 6
    DIU 2BSYN 0A
    32 7
    DIU 1BDIU 3A
    33 8
    DIU 0BDIU 2A
    34 9
    DCS BDIU 1A
    35 10 DIU 0A
    36 11 DCS A
    37 12
    38 13
    EXCLK0
    (Slot No.21) EXCLK1
    (Slot No.23)TSWMREAR VIEW
    34PH EXCLK 
    CA-A
    34PH EXCLK CA-A34PH EXCLK CA-A LEAD ACCOMMODATION
    Installation Cable
    MDF
    To Digital Interface and/or DCS
    Mounting ModuleTSWM 
    						
    							ND-70182 (E) CHAPTER 3
    Page 191
    Revision 4.0
    PH-CK17
    Phase Lock Oscillator
    Figure 3-23   Connecting Route Diagram
    DCSB1
    DIU0A1
    DIU0B1
    DIU1A1
    DIU1B1
    DIU2A1
    DIU2B1
    DIU3A1
    DIU3B1 DCSA1
    DCSB0
    DIU0A0
    DIU0B0
    DIU1A0
    DIU1B0
    DIU2A0
    DIU2B0
    DIU3A0
    DIU3B0 DCSA0
    POUT B POUT A
    POUT B
    POUT A
    POUT B
    POUT A
    POUT B
    POUT A
    CCT /DTI
    /PRT
    CCT /DTI
    /PRT
    CCT /DTI
    /PRT
    CCT /DTI
    /PRT
    PLO #0
    PLO #1
    DCS
    Note :
    The following circuit cards have Clock Output Leads for a PLO card:  CCT (PA-24CCTA, PA-30CCTB),
    DTI (PA-24DTR, PA-30DTS), and PRT (PA-24PRT, PA-30PRTC). 
    MDF PBX 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 192
    Revision 4.0
    PH-CK17
    Phase Lock Oscillator
    7. Switch Setting Sheet
    SWITCH NAME SWITCH SHAPE REMARKS
    MB
    SW01
    SW02
    SW03
    SW05
    SW06
    SW04
    ON
    1234ON5678
    1234ON5678
    12ON
    1234ON
    1234ON5678 
    						
    							ND-70182 (E) CHAPTER 3
    Page 193
    Revision 4.0
    PH-CK17-A
    Phase Lock Oscillator
    PH-CK17-A
    Phase Lock Oscillator
    1. General Function
    This circuit card used together with a direct digital interface circuit card, sets up network synchronization
    between networks. Since this circuit card provides a high precision base clock oscillator, the system
    containing this circuit card can be a clock source office of the digital network. As seen in the figure below,
    the PLO can be redundant regardless of the system switching network selection. This circuit card is used
    for the IMX-U system.
    Figure 3-24   Location of PH-CK17-A (PLO)
    LN0
    (IMG2/IMG3)LN3
    (IMG2/IMG3)
    32M, FH+WFH
    PLO ACT32M, FH+WFH
    PLO ACT
    CLK1
    (TSWM1)
    TSW
    10~13
    CLK0
    (TSWM1)
    TSW
    00~03
    MUX
    (System1)MUX
    (System0)
    LC/TRK
    HSW00 ISW
    HSW01
    CLK1
    (TSWM1)
    TSW
    10~13
    CLK0
    (TSWM1)
    TSW
    00~03
    MUX
    (System1)MUX
    (System0)
    LC/TRK
    LN0
    (IMG0/IMG1)from
    LN DTIfrom
    LN DTI
    32M, FH+WFH
    PLO ACT32M, FH+WFH
    PLO ACT
    (BWB)32M, FH+WFH
    PLO ACT
    (BWB)
    64K+FH, WFH
    TSW ACT
    (Cable)64K+FH, WFH
    TSW ACT
    (Cable)
    PLO 1
    (TSWM0)
    TSW
    10~13
    PLO 0
    (TSWM0)
    TSW
    00~03
    MUX
    (System1)MUX
    (System0)
    LC/TRK
    LN3
    (IMG0/IMG1)
    32M, FH+WFH
    PLO ACT
    PLO 1
    (TSWM0)
    TSW
    10~13
    PLO 0
    (TSWM0)
    TSW
    00~03
    MUX
    (System1)MUX
    (System0)
    LC/TRK
    TSW00 TSW03HSW10 OSC64K+8K
    (BWB)
    (BWB)
    CLK, FH, WFH
    ACT, ALM
    PLO 0
    DTI0 DCS0 (MDF) DCS1123
    PLO 1
    SEL
    PLL
    Drv
    HSW11
    TSW10 TSW13
    SEL
    PLL
    Drv
    OSC
    ~
    ~~
    ~ 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 194
    Revision 4.0
    PH-CK17-A
    Phase Lock Oscillator
    2. Mounting Location/Condition
    This circuit card can be mounted in the shaded slots shown below.
    Mounting ModuleISWM
    00 01 02 03 04 05 06 070809 10 111213 14 15 16 17 18 19
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 1920212223
    PLO (#0) PLO (#1)
    Mounting ModuleTSWM0 (IMG1)
    PLO (#0) PLO (#1) 
    						
    							ND-70182 (E) CHAPTER 3
    Page 195
    Revision 4.0
    PH-CK17-A
    Phase Lock Oscillator
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors are shown in Figure 3-25
    Figure 3-25   Face Layout of PH-CK17-A (PLO)
    1   2  3  4  
    1   2    
    SW11
    SW10SW12
    MB OPE
    1   2  3  4  5  6  7  8 
    SW01
    SW02
    SW03
    12345678 12345678
    MJ
    MN
    SYNC
    ICK
    CKPKG
    ALM0
    ALM1
    PALM 
    						
    All NEC manuals Comments (0)