Home > NEC > Communications System > NEC Neax 2400 Imx Circuit Card Manual

NEC Neax 2400 Imx Circuit Card Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Circuit Card Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 2 ND-70182 (E)
    Page 136
    Revision 4.0
    PZ-GT16
    Industrial Standard Architecture Gateway
    2. Mounting Location/Condition
    The PZ-GT16 (ISAGT) is located on the ISA bus, which is allocated in the CPR as shown below.
    PZ-GT16 (GT)
    CPU BOARD
    PZ-DK224 (DSP) PZ-PC19 (LANI)
    PZ-PW92 (PWR)
    PZ-IO27 (FDD/HDD)
    LPMMounting Module 
    						
    							ND-70182 (E) CHAPTER 2
    Page 137
    Revision 4.0
    PZ-GT16
    Industrial Standard Architecture Gateway
    3. Face Layout of Connectors
    The face layout of connectors is shown in Figure 2-67. There are no lamps or switches on this circuit card. 
    Figure 2-67   Face Layout of PZ-GT16 (ISAGT)
    4. Lamp Indications
    This card contains no lamps.
    5. Switch Settings
    No switch settings are required.
    6. External Interface
    See the NEAX2400 IMX Installation Manual.
    7. Switch Setting Sheet
    No switch settings are required.
    ISA BUS INTERFACE
    FRONT VIEW
    PWG
    DSPP
    CONN
    AB 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 138
    Revision 4.0
    PZ-GT20
    Industry Standard Architecture Gateway
    PZ-GT20
    Industry Standard Architecture Gateway
    1. General Function
    The main function of the PZ-GT20 circuit card is to connect the Industry Standard Architecture (ISA) bus
    located on the CPU and the Local I/O bus, permitting the microprocessor on the CPU to control the TSW,
    MUX cards of IMG2, 3 via the PH-GT09 card in the TSWM1. This circuit card is used for the IMX-U
    system.
    Figure 2-68   Location of PZ-GT20 (ISAGT)
    TSW03
    TSW02
    TSW01
    TSW00
    LANI
    LANI
    LANI
    LANI
    TSW13
    TSW12
    TSW11
    TSW10
    PLO 1
    PLO 0
    CPU#0CPU#1EMAPH-GT09
    (IOGT1) PH-GT09
    (IOGT0)PZ-GT13
    (ISAGT)
    PZ-GT20
    (ISAGT)PZ-GT20
    (ISAGT)
    PZ-GT13
    (ISAGT)
    ISA BUS
    ISA BUS
    LPM (IMG0) GT-BUS
    GT-BUSTSWM#1 (IMG2)
    TSWM#0 (IMG1)
    TSW03
    TSW02
    TSW01
    TSW00
    TSW13
    TSW12
    TSW11
    TSW10
    CLK 1
    CLK 0
    PH-GT09
    (IOGT1) PH-GT09
    (IOGT0)TSW I/O BUS
    TSW I/O BUS
    IOC/MISC
    MISC 
    						
    							ND-70182 (E) CHAPTER 2
    Page 139
    Revision 4.0
    PZ-GT20
    Industry Standard Architecture Gateway
    2. Mounting Location/Condition
    The PZ-GT20 resides on the ISA bus that is located in the CPR as shown below.
    3. Face Layout of Connectors
    The face layout of connectors are shown in Figure 2-69. Neither lamps nor switches are located on this cir-
    cuit card.
    Figure 2-69   Face Layout of PZ-GT20 (ISAGT)
    PZ-GT20 (ISAGT) PZ-GT13 (ISAGT)
    CPU BOARD
    PZ-DK224 (DSP) PZ-PC19 (LANI)
    PZ-PW92 (PWR)
    PZ-IO27 (FDD/HDD)
    LPM(IMG0)Mounting Module
    ISA BUS INTERFACE 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 140
    Revision 4.0
    PZ-GT20
    Industry Standard Architecture Gateway
    4. External Interface
    This card contains no lamps.
    5. Switch Settings
    No switch settings are required.
    6. External Interface
    See the NEAX2400 IMX Installation Manual.
    7. Switch Setting Sheet
    No switch settings are required. 
    						
    							ND-70182 (E) CHAPTER 2
    Page 141
    Revision 4.0
    PZ-PC19
    Local Area Network Interface
    PZ-PC19
    Local Area Network Interface
    1. General Function
    The PZ-PC19 (LANI) circuit card provides the interface for the 10-BASE-T and the Peripheral Component
    Interconnect (PCI) Bus. The microprocessor on the CPR sends/receives the Fusion Link Data and/or
    Maintenance Administration Terminal (MAT) data across the LAN interface (LANI). 
    Figure 2-70   Location of PZ-PC19 (LANI)
    To another Fusion Node
    FCCH DTI DTI FCCH
    HUB
    HUB HUB
    LANI
    LANI LANI CPUISAGT
    ISAGT
    LANIDSP DSP
    CPR #1 CPR #0
    NIC  MAT PCI
    10-BASE-T 10-BASE-TCPU
    IMX 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 142
    Revision 4.0
    PZ-PC19
    Local Area Network Interface
    2. Mounting Location/Condition
    The PZ-PC19 (LANI) is located on the PCI bus in the CPR as shown below.
    3. Face Layout of Lamps, Switches and Connectors
    The face layout of lamps, switches and connectors is shown in Figure 2-71.
    Figure 2-71   Face Layout of PZ-PC19
    Mounting ModuleLPM
    PZ-GT13/GT16 (ISAGT)
    CPU BOARD
    PZ-DK224 (DSP) PZ-PC19 (LANI)
    PZ-PW92 (PWR)
    PZ-IO27 (FDD/HDD)
    10 BASE-T
    EST3EST2 EST1 EST0
    PCI BUS INTERFACE 
    						
    							ND-70182 (E) CHAPTER 2
    Page 143
    Revision 4.0
    PZ-PC19
    Local Area Network Interface
    4. Lamp Indications
     Lamp indications for this circuit card are shown in the table below.
    5. Switch Settings
    No switch settings are required.
    LAMP NAME COLOR DESCRIPTION
    EST0 Green Layer 1 link has established.
    EST1 Green Data packet sending/receiving.
    EST2 Red Layer 1 link failure.
    EST3 Yellow Data packet collision has occurred. 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 144
    Revision 4.0
    PZ-PC19
    Local Area Network Interface
    6. External Interface
    7. Switch Setting Sheet
    No switch settings are required.
    24DTR
    CN2FCH
    FCH
    PZ-PC19(LANI)
    HUB
    10 BASE-T straight Cable 10 BASE-T straight Cable TO IMX MAT10 BASE-T straight CableHUB
    10AL (10)FLT CA
    DTI 
    						
    							ND-70182 (E) CHAPTER 3
    Page 145
    Revision 4.0
    CHAPTER 3 LINE/TRUNK CIRCUIT CARD REFERENCE
    1. General
    This chapter explains the following items about circuit cards.
    General Function
    Explains the general function and purpose for each control circuit card.
    Mounting Location/Condition
    Explains the mounting location (mounting module name and slot number, etc.) of each circuit card. If there
    are any conditions pertaining to mounting the circuit cards, they are also explained. 
    Face Layout of Lamps, Switches, and Connectors
    The locations of the lamps, switches, and connectors provided on each circuit card are illustrated by a face
    layout.
    Lamp Indications
    Names, colors, and indication states of lamps mounted on each circuit card are listed.
    Switch Settings
    Each circuit card’s switches are listed with their names, switch numbers, setting and its meaning, standard
    setting, etc.
     External Interface
    If the lead outputs of the circuit card are provided by an LT connector, the relation between the mounting
    slots and the LT connectors is illustrated by an LT Connector Lead Face Layout. If the lead outputs are
    provided by other than an LT connector, or are provided by the circuit card front connector, the connector
    lead locations and the connecting routes are shown.
     In addition, a Switch Setting Sheet is provided at the end of the explanation of circuit cards. 
    						
    All NEC manuals Comments (0)