CHAPTER 2 ND-70182 (E) Page 136 Revision 4.0 PZ-GT16 Industrial Standard Architecture Gateway 2. Mounting Location/Condition The PZ-GT16 (ISAGT) is located on the ISA bus, which is allocated in the CPR as shown below. PZ-GT16 (GT) CPU BOARD PZ-DK224 (DSP) PZ-PC19 (LANI) PZ-PW92 (PWR) PZ-IO27 (FDD/HDD) LPMMounting Module
ND-70182 (E) CHAPTER 2 Page 137 Revision 4.0 PZ-GT16 Industrial Standard Architecture Gateway 3. Face Layout of Connectors The face layout of connectors is shown in Figure 2-67. There are no lamps or switches on this circuit card. Figure 2-67 Face Layout of PZ-GT16 (ISAGT) 4. Lamp Indications This card contains no lamps. 5. Switch Settings No switch settings are required. 6. External Interface See the NEAX2400 IMX Installation Manual. 7. Switch Setting Sheet No switch settings are required. ISA BUS INTERFACE FRONT VIEW PWG DSPP CONN AB
CHAPTER 2 ND-70182 (E) Page 138 Revision 4.0 PZ-GT20 Industry Standard Architecture Gateway PZ-GT20 Industry Standard Architecture Gateway 1. General Function The main function of the PZ-GT20 circuit card is to connect the Industry Standard Architecture (ISA) bus located on the CPU and the Local I/O bus, permitting the microprocessor on the CPU to control the TSW, MUX cards of IMG2, 3 via the PH-GT09 card in the TSWM1. This circuit card is used for the IMX-U system. Figure 2-68 Location of PZ-GT20 (ISAGT) TSW03 TSW02 TSW01 TSW00 LANI LANI LANI LANI TSW13 TSW12 TSW11 TSW10 PLO 1 PLO 0 CPU#0CPU#1EMAPH-GT09 (IOGT1) PH-GT09 (IOGT0)PZ-GT13 (ISAGT) PZ-GT20 (ISAGT)PZ-GT20 (ISAGT) PZ-GT13 (ISAGT) ISA BUS ISA BUS LPM (IMG0) GT-BUS GT-BUSTSWM#1 (IMG2) TSWM#0 (IMG1) TSW03 TSW02 TSW01 TSW00 TSW13 TSW12 TSW11 TSW10 CLK 1 CLK 0 PH-GT09 (IOGT1) PH-GT09 (IOGT0)TSW I/O BUS TSW I/O BUS IOC/MISC MISC
ND-70182 (E) CHAPTER 2 Page 139 Revision 4.0 PZ-GT20 Industry Standard Architecture Gateway 2. Mounting Location/Condition The PZ-GT20 resides on the ISA bus that is located in the CPR as shown below. 3. Face Layout of Connectors The face layout of connectors are shown in Figure 2-69. Neither lamps nor switches are located on this cir- cuit card. Figure 2-69 Face Layout of PZ-GT20 (ISAGT) PZ-GT20 (ISAGT) PZ-GT13 (ISAGT) CPU BOARD PZ-DK224 (DSP) PZ-PC19 (LANI) PZ-PW92 (PWR) PZ-IO27 (FDD/HDD) LPM(IMG0)Mounting Module ISA BUS INTERFACE
CHAPTER 2 ND-70182 (E) Page 140 Revision 4.0 PZ-GT20 Industry Standard Architecture Gateway 4. External Interface This card contains no lamps. 5. Switch Settings No switch settings are required. 6. External Interface See the NEAX2400 IMX Installation Manual. 7. Switch Setting Sheet No switch settings are required.
ND-70182 (E) CHAPTER 2 Page 141 Revision 4.0 PZ-PC19 Local Area Network Interface PZ-PC19 Local Area Network Interface 1. General Function The PZ-PC19 (LANI) circuit card provides the interface for the 10-BASE-T and the Peripheral Component Interconnect (PCI) Bus. The microprocessor on the CPR sends/receives the Fusion Link Data and/or Maintenance Administration Terminal (MAT) data across the LAN interface (LANI). Figure 2-70 Location of PZ-PC19 (LANI) To another Fusion Node FCCH DTI DTI FCCH HUB HUB HUB LANI LANI LANI CPUISAGT ISAGT LANIDSP DSP CPR #1 CPR #0 NIC MAT PCI 10-BASE-T 10-BASE-TCPU IMX
CHAPTER 2 ND-70182 (E) Page 142 Revision 4.0 PZ-PC19 Local Area Network Interface 2. Mounting Location/Condition The PZ-PC19 (LANI) is located on the PCI bus in the CPR as shown below. 3. Face Layout of Lamps, Switches and Connectors The face layout of lamps, switches and connectors is shown in Figure 2-71. Figure 2-71 Face Layout of PZ-PC19 Mounting ModuleLPM PZ-GT13/GT16 (ISAGT) CPU BOARD PZ-DK224 (DSP) PZ-PC19 (LANI) PZ-PW92 (PWR) PZ-IO27 (FDD/HDD) 10 BASE-T EST3EST2 EST1 EST0 PCI BUS INTERFACE
ND-70182 (E) CHAPTER 2 Page 143 Revision 4.0 PZ-PC19 Local Area Network Interface 4. Lamp Indications Lamp indications for this circuit card are shown in the table below. 5. Switch Settings No switch settings are required. LAMP NAME COLOR DESCRIPTION EST0 Green Layer 1 link has established. EST1 Green Data packet sending/receiving. EST2 Red Layer 1 link failure. EST3 Yellow Data packet collision has occurred.
CHAPTER 2 ND-70182 (E) Page 144 Revision 4.0 PZ-PC19 Local Area Network Interface 6. External Interface 7. Switch Setting Sheet No switch settings are required. 24DTR CN2FCH FCH PZ-PC19(LANI) HUB 10 BASE-T straight Cable 10 BASE-T straight Cable TO IMX MAT10 BASE-T straight CableHUB 10AL (10)FLT CA DTI
ND-70182 (E) CHAPTER 3 Page 145 Revision 4.0 CHAPTER 3 LINE/TRUNK CIRCUIT CARD REFERENCE 1. General This chapter explains the following items about circuit cards. General Function Explains the general function and purpose for each control circuit card. Mounting Location/Condition Explains the mounting location (mounting module name and slot number, etc.) of each circuit card. If there are any conditions pertaining to mounting the circuit cards, they are also explained. Face Layout of Lamps, Switches, and Connectors The locations of the lamps, switches, and connectors provided on each circuit card are illustrated by a face layout. Lamp Indications Names, colors, and indication states of lamps mounted on each circuit card are listed. Switch Settings Each circuit card’s switches are listed with their names, switch numbers, setting and its meaning, standard setting, etc. External Interface If the lead outputs of the circuit card are provided by an LT connector, the relation between the mounting slots and the LT connectors is illustrated by an LT Connector Lead Face Layout. If the lead outputs are provided by other than an LT connector, or are provided by the circuit card front connector, the connector lead locations and the connecting routes are shown. In addition, a Switch Setting Sheet is provided at the end of the explanation of circuit cards.