    							CHAPTER 2 ND-70182 (E)
    Page 36
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    5. Switch Settings
    Note:Make-busy of this circuit card is not allowed while the Floppy Disk Drive or Hard Disk Drive is being
    accessed.
    SWITCH NAMESWITCH 
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    SW
    (PWR)—ON×PWR is supplied to the CPR.
    OFF PWR is not supplied to the CPR.
    MB
     Note
    (FDD/HDD)—ON (Up) Make-busy of the FDD/HDD.
    OFF (Down)×Normal setting.
    MBR
    (DSP)—ON (Up)Make-busy Request of the CPR in which GT is 
    located.
    OFF (Down)×Normal setting.
    CPURST
    (DSP)——Execute the CPR processing according to the 
    SENSE setting.
    SYSTEM 
    SELECT0
    (DSP)1OFF×Not used
    2OFF×Not used
    3OFF×Not used
    4ON Watchdog Timer time-out is not detected.
    OFF×Watchdog Timer time-out is detected.
    SYSTEM 
    SELECT1
    (DSP)1ON PCI Card (Slot 0) MBR ON.
    OFF PCI Card (Slot 0) MBR OFF.
    2ON PCI Card (Slot 1) MBR ON.
    OFF PCI Card (Slot 1) MBR OFF.
    3ON PCI Card (Slot 2) MBR ON.
    OFF PCI Card (Slot 2) MBR OFF.
    4ON PCI Card (Slot 3) MBR ON.
    OFF PCI Card (Slot 3) MBR OFF.
    5~7 OFF×Fixed to “OFF.”
    8ON IMX-U System
    OFF 1 IMG/4 IMG System
    SYSTEM 
    SELECT2 
    (DSP)1~8 OFF×Not used 
    						
    							ND-70182 (E) CHAPTER 2
    Page 37
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    Note:
    The SENSE switch designates the CPR processing status. The new processing status starts when the
    CPRRST switch on the DSP is pressed while setting the SENSE switch.
    SWITCH 
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    SENSE
    (DSP)
    Note1The following three processes are executed at the FDD/HDD.
     HD formatted
     File copied from FDD to HD 
     Directory created on the HD
    2×On-line mode.
    3 File copied from FDD to HD within the FDD/HDD.
    4 Directory created on the HD of the FDD/HDD.
    5OAI memory cleared, and the CPR started up in ON LINE mode by loading 
    the ROM data.
    6 HD format of the FDD/HDD.
    C The CPR starts up in OFF LINE mode by loading the ROM data. 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 38
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    6. External Interface
    See the NEAX2400 IMX Installation Manual.
    7. Switch Setting Sheet
    SWITCH NAME SWITCH SHAPE REMARKS
    SW
    (PWR)
    MB
    (PWR:PZ-PW106)
    MB
    (FDD/HDD)
    MBR
    (DSP)
    SYSTEM
     SELECT0
    (DSP)
    SYSTEM 
    SELECT1
    (DSP)
    SYSTEM
    SELECT2
    (DSP)
    SENSE
    (DSP)
    ON
    OFF
    ON
    ON
    ON
    1234ON
    1234ON5678
    1234ON5678 
    						
    							ND-70182 (E) CHAPTER 2
    Page 39
    Revision 4.0
    PH-GT10
    Input Output Gate
    PH-GT10
    Input Output Gate
    1. General Function
    The PH-GT10 circuit card provides the TSW I/O bus interface for permitting the CPU board to control the
    TSW, HSW, and PLO cards within the Inter-node Switch Module (ISWM) of the ISW. Additionally, this
    circuit card is equipped with the copy function to be consistent with the data of TSW I/O bus in both
    systems (single/dual). This circuit card is used for the IMX-U system.
    Figure 2-12   Location of PH-GT10 (IOGT) 
    HSW01
    HSW00
    TSW03
    TSW02
    TSW01
    TSW00
    LANI
    LANI
    LANI
    LANI
    HSW11
    HSW10
    TSW13
    TSW12
    TSW11
    TSW10
    PLO 1
    PLO 0
    RES
    CPUCPU
    MISC
    IOC
    EMARES
    RESRES
    (IOGT1)
    PH-GT10 (IOGT0)
    PH-GT10
    ISAGTISAGT
    MISC I/O BUSISAGT BUS ISAGT BUSLPM TSW I/O BUS TSW I/O BUSISWM 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 40
    Revision 4.0
    PH-GT10
    Input Output Gate
    2. Mounting Location/Condition
    This circuit card can be mounted in the shaded slots shown below.
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors are shown in Figure 2-13.
    Figure 2-13   Face Layout of PH-GT10 (IOGT)
    ISWMMounting Module
    00   01    02    03    04    05   06    07    08   09    10    11    12    13   14    15    16    17    18    19   
    IOGT(#0) IOGT(#1)
    MB
    MBR OPE/MB
    PWRALM
    CA4L
    COPY 
    						
    							ND-70182 (E) CHAPTER 2
    Page 41
    Revision 4.0
    PH-GT10
    Input Output Gate
    4. Lamp Indications
    The contents of lamp indications on this circuit card are shown in the table below.
    5. Switch Settings
    Standard settings of switches on this circuit card are shown in the table below.
    6. External Interface
    See the NEAX2400 IMX Installation Manual.
    7. Switch Setting Sheet
    LAMP NAME COLOR MEANING
    TSW ACTGreen Lights when this circuit card is in ACT state.
    OFF This circuit card is in ST-BY state.
    Red Lights when this circuit card is in make-busy state.
    PWRALM Red Lights when On-Board Power Supply for this circuit card is abnormal.
    CA4L Red Lights when 4MHz clock supplied for Local I/O Bus is faulty.
    COPY Green Lights when this circuit card is in COPY mode.
    SWITCH 
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    MBUP Circuit Card make busy
    DOWN×Circuit Card make busy cancel
    MBR UP Make busy request
    DOWN×Make busy request cancel
    SWITCH NAME SWITCH SHAPE
    MB
    Note:Normal operating mode is down.
    MBR
    Note:Normal operating mode is down.
    ON
    ON 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 42
    Revision 4.0
    PA - P C 9 4
    Data Link Multiplexer
    PA - P C 9 4
    Data Link Multiplexer
    1. General Function
    This circuit card mainly provides the two functions: 1) collection of BLF/TGBL information (associated
    with Attendant/Desk Console operation) from DLKC cards of all nodes in an IMX-U system, and 2)
    distribution of the collected data to ATI cards of all nodes. While a DLKC card can manage this processing
    solely on an accommodated node basis, the use of this card makes possible the BLF/TGBL management
    even on a system basis, via the Inter-node Switch (ISW). Note that this card is mounted in a PIM of any
    node, and if necessary, can have an optional dual configuration.
    For details on BLF/TGBL information, refer to the following service features explained in the “Feature
    Programming Manual”.
     Busy Lamp Field-Flexible [B-2]
     Trunk Group Busy Lamp [T-9]
    Figure 2-14   Location of PA-PC94 (DLMX)
    IMX-U System
    AT I
    AT I
    AT I
    AT I
    (TSW 1)(TSW 1)
    (TSW 1)
    (TSW 1)
    TSW/HSW 1
    DLMX 0(DLMX 1)IN OUT
    DLKC 0(DLKC 1)
    DLKC 0(DLKC 1)
    DLKC 0(DLKC 1)
    DLKC 0(DLKC 1)
    TSW 0TSW 0
    TSW 0
    TSW 0
    TSW/HSW 0
    LN 0LN 1
    LN 2
    LN 3 ISW
    Note
    :  Circuit Card
    :  Circuit Card (No. 1 System)
    :  BLF/TGBL data from DLKC
    :  BLF/TGBL data to ATI
    :  BLF/TGBL data to ATI
       (No. 1 system)
    :  BLF/TGBL data from DLKC
       (No. 1 system)
    BLF:  Busy Lamp Field - Flexible
    TGBL:  Trunk Group Busy Lamp
    Note:IN     - DLMX card gathers BLF/TGBL information from DLKC card of each node, via ISW.
    OUT - DLMX card sends the collected BLF/TGBL information to ATI card(s) of each node, via ISW. This figure shows an example where a pair of DLMX cards (No. 0/No. 1 system) is accommodated in a PIM of LN0. 
    						
    							ND-70182 (E) CHAPTER 2
    Page 43
    Revision 4.0
    PA - P C 9 4
    Data Link Multiplexer
    2. Mounting Location/Condition
    When this circuit card is used in a single configuration.
    Mount this circuit card in any of the shaded slots
    Mounting conditions of this circuit card are as follows:
    1. This circuit card cannot be mounted in Slot 05, 07, 09, 10, 11, 12, 16, 18, 19, 21, 22, 23.
    2. This card is used in odd-number group (G) of the shaded slots above.
    3. To used this card, be sure to assign “RT=938” on the ASDT command.
    4. Do not mount another line/trunk circuit card in a slot adjoining the DLMX card within the same
    Highway Block (HW) (i.e. do not mount other line/trunk card in the right side of the slot where a
    DLMX card is mounted).
    When this circuit card is used in a dual configuration.
    Mount this circuit card in any of the shaded slots:
    Mounting conditions of this circuit card are as follows:
    1. A pair of DLMX card No. 0/No. 1 systems must be mounted in the same Highway Block (HW).
    2. This circuit card cannot be mounted in 32-port slot (10, 11,12, 21, 22, 23).
    3. This card is used in odd-number group (G) of the shaded slots above.
    4. To use this card, be sure to assign “RT = 9 3 8” on the ASDT command.
        
    HW 0HW 1HW 2HW 6HW 7HW 8 Highway block
    DLMXDLMXDLMXDLMXDLMX
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 1918 20 21 22 23
    DLMX
    Mounting ModulePIM
    Mounting Condition
    HW 0HW 1HW 2HW 6HW 7HW 8 Highway Block
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 1918 20 21 22 23
    DLMX #0 DLMX #1
    DLMX #0
    DLMX #1 DLMX #0 DLMX #1 DLMX #0 DLMX #1 DLMX #0 DLMX #1 DLMX #0 DLMX #1
    Mounting ModulePIM
    Mounting Condition 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 44
    Revision 4.0
    PA - P C 9 4
    Data Link Multiplexer
    3. Face Layout of Lamps and Switches
    The face layout of lamps and switches is shown in Figure 2-15.
    Figure 2-15   Face Layout of PA-PC94 (DLMX)
    4. Lamp Indications
    The contents of lamp indications on this circuit card are shown in the table below:
    LAMP NAME COLOR STATE
    OPE Green Remains lit while this circuit card is in normal operation.
    ACTGreen Lights when this circuit card is in a active state.
    OFF Off when this circuit card is in a stand-by state.
    LYR OFF Off when this circuit card is in normal operation.
    LB OFF Off when this circuit card is in normal operation.
    LOAD OFF Off when this circuit card is in normal operation.
    PWALM Red Lights when OBP alarm
    ACT
    PWALMLOADLBLY R
    MB KEYOPE
    MNT
    MODE 
    						
    							ND-70182 (E) CHAPTER 2
    Page 45
    Revision 4.0
    PA - P C 9 4
    Data Link Multiplexer
    5. Switch Settings
    Standard settings of switches on this circuit card are shown in the table below.
    6. Switch Setting Sheet
    SWITCH
     NAMESWITCH
    No.SETTINGSTANDARD
    SETTINGMEANING
    MBUP Circuit card make-busy.
    DOWN Circuit card make-busy cancel
    MNT0OFF×Fixed to OFF.
    1OFF×Fixed to OFF.
    2OFF×Fixed to OFF.
    3ON Make-busy-request.
    OFF Cancel the make-busy-request. 
    MODE0×Standard setting. (TSW fixed connection)
    1-7 Not used
    SWITCH
     NAMESWITCH SHAPE REMARKS
    MB
    MNT
    MODE
    ON
    0 1 2 3
    ON
    0 
    						