    							CHAPTER 3 ND-70182 (E)
    Page 306
    Revision 4.0
    PA - 8 R S T Y
    Register Sender Trunk
    SWITCH FUNCTION SWITCH SETTING MEANING
    SW10
    1
    3
    DTMF Signal 
    Receiver
    Threshold Value 
    [Standard Setting]
    4
    OFF Fixed to OFF
    SW11
    1
    3
    MFR Signal Receiver
    Threshold Value
    [Standard Setting]
    4
    OFF Fixed to OFF
     1   2   3   4
    ~
    ON
    OFF 1   2   3   4
    Selection of PBR Threshold Value
    SW10-1 SW10-2 SW10-3DTMF Threshold Value
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFFON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFFON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF-21.0 dBm0
    -23.0 dBm0
    -25.0 dBm0
    -27.0 dBm0
    -29.0 dBm0
    -31.0 dBm0
    -33.0 dBm0
    -35.0 dBm0
     1   2   3   4
    ~
    ON
    OFF 1   2   3   4
    Selection of MFR Threshold Value
    SW11-1 SW11-2 SW11-3MFR Threshold Value
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFFON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFFON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF-17.0 dBm0
    -19.0 dBm0
    -21.0 dBm0
    -23.0 dBm0
    -25.0 dBm0
    -27.0 dBm0
    -29.0 dBm0
    -31.0 dBm0 
    						
    							ND-70182 (E) CHAPTER 3
    Page 307
    Revision 4.0
    PA - 8 R S T Y
    Register Sender Trunk
    SWITCH FUNCTION SWITCH SETTING MEANING
    SW12
    1
    Designation of MFR 
    SpecificationAT & T specification
    ITU-T No. 5 specification
    2
    DTMF Signal
    Cut-off Guard 
    TimerSHORT (less than 10 ms)
    [Standard Setting]
    LONG (less than 20 ms)
    3Register Selection
    (MFR/PBR)REG #0, #1, #2, #3 function as MFR.
    REG #0, #1, #2, #3 function as PBR.
    4Register Selection
    (MFR/PBR)REG #4, #5, #6, #7 function as MFR.
    REG #4, #5, #6, #7 function as PBR.
     1   2   3   4
     1   2   3   4
     1   2   3   4
     1   2   3   4
     1   2   3   4
     1   2   3   4
     1   2   3   4
     1   2   3   4
     1   2   3   4 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 308
    Revision 4.0
    PA - 8 R S T Y
    Register Sender Trunk
    SWITCH SWITCH 
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    SW13
    1ON MF Transmission Level:-9dBm
    OFF MF Transmission Level:-5dBm
    2OFF×Fixed to OFF
    3OFF×Fixed to OFF
    4OFF×Fixed to OFF
    SW14
    1OFF×Fixed to OFF
    2OFF×Fixed to OFF
    3OFF×Fixed to OFF
    4OFF×Fixed to OFF
    SW15
    1OFF×Fixed to OFF
    2OFF×Fixed to OFF
    3OFF×Fixed to OFF
    4OFF×Fixed to OFF
    SW161ON
    ×Fixed to ON
    2OFF
    ×Fixed to OFF
    3OFF
    ×Fixed to OFF
    4OFF
    ×Fixed to OFF
    SW171OFF
    ×Fixed to OFF
    2OFF
    ×Fixed to OFF
    3OFF
    ×Fixed to OFF
    4OFF
    ×Fixed to OFF 
    						
    							ND-70182 (E) CHAPTER 3
    Page 309
    Revision 4.0
    PA - 8 R S T Y
    Register Sender Trunk
    MODULE SLOT NO. SWITCH NAME SWITCH SHAPE REMARKS
    PIMSW00
    (MB)Circuit card make busy cancel.
    Standard Setting: Down
    SW01
    (MBR0-7)
    SW02
    (MBS0-7)
    SW10
    SW11
    7
    6
    5
    4OFF
    3
    2
    1 8
    7
    6
    5
    4
    3
    2
    1 8
    OFF
    ON 1   2   3   4
    ON 1   2   3   4 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 310
    Revision 4.0
    PA - 8 R S T Y
    Register Sender Trunk
    PIMSW12
    SW13
    SW14
    SW15
    SW16
    SW17 MODULE SLOT NO. SWITCH NAME SWITCH SHAPE REMARKS
     1   2   3   4ON
     1   2   3   4ON
     1   2   3   4ON
     1   2   3   4ON
     1   2   3   4ON
     1   2   3   4ON 
    						
    							ND-70182 (E) CHAPTER 3
    Page 311
    Revision 4.0
    PA - S D TA
    SDH/SONET Digital Trunk
    PA - S D TA
    SDH/SONET Digital Trunk
    1. General Function
    The PA-SDTA circuit card provides a maximum of 28 interface (1.5 Mbps) used with the fiber optic cable.
    This card has also the MUX function and is connected directly to the TSW card. This card is used with the
    PA-SDTB card.
    Figure 3-78   Location of PA-SDTA (SDT) Card in the System 
    F u s i o n
    Node-A
    Fiber Optic Cable
    Fiber Optic Cable
    For Dual Configuration Connection Link (Data Link)
    Connection Trunk (Speech Path)
    Internal LAN
    FCH
    S
    D
    T
    B
    Node-B
    Internal LAN
    S
    D
    T
    BFCH+
    Fusion Link with FCCH
    Fusion Link without FCCH
    F u s i o n
    Node-A
    Internal LANNode-B
       )  SDT: SDH/SONET Digital Trunk
          FCH: Fusion Call Control Handler*
    Fiber Optic Cable
    Fiber Optic Cable
    For Dual Configuration Connection Trunk (Speech Path)
    S
    D
    T
    BS
    D
    T
    B
    SDTA
    SDTA
    SDTA
    SDTA
    SDTA
    SDTA
    SDTA
    SDTA 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 312
    Revision 4.0
    PA - S D TA
    SDH/SONET Digital Trunk
    2. Mounting Location/Condition
    This circuit card is mounted in a universal slot next to (either left or right side of) PA-SDTB. When this
    card is provided in a dual configuration, mount this card on both sides of PA-SDTB.
    Mounting conditions are shown below.
    Only the power is supplied from Back Wiring Board (BWB).
    This card is connected to the PA-SDTB card using the following front cables.
    For single configuration: SDT CABLEB 
    For dual configuration: SDT CABLEA 
    Fiber optic cables are connected to this card.
    Time slots used for this circuit card are determined by the cable connection between the PA-SDTB and
    TSW.
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting ModulePIM
    Universal SlotsUniversal Slots 
    						
    							ND-70182 (E) CHAPTER 3
    Page 313
    Revision 4.0
    PA - S D TA
    SDH/SONET Digital Trunk
    Example: When the PA-SDTA card is mounted in the 1-IMG system
    As shown in Figure 3-79, time slots of Module Group 01 are used. AUNT data is required even if PIM2/
    PIM3 is not actually mounted.
    Figure 3-79   PA-SDTA Card Mounted in the 1 IMG System
    ( TS of PIM3 is used for SDT. )
    ( TS of PIM2 is used for SDT. )
    PH-PC30 (MUX) PH-SW10 (TSW)
    MUX3
    MUX2
    MUX1
    MUXPH-PC30 (MUX) PH-SW10 (TSW)
    MUX3
    MUX2
    MUX1
    MUX
    PA-SDTB (SDTB)
    MUX1A MUX0A
    MUX0B
    MUX1B
    PA-SDTA (SDTA)
    PIM3
    (Not actually
    mounted)
    PIM2
    (Not actually
    mounted)
    PIM1
    PIM0
    LPM
    I/O
    PCMI/O
    PCM 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 314
    Revision 4.0
    PA - S D TA
    SDH/SONET Digital Trunk
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout for lamps, switches, and connectors are shown in Figure 3-80.
    Figure 3-80   Face Layout of PA-SDTA (SDT)
    MB
    PCM
    SC P-SW
    I/O
    SW11 SW12
    OPE
    ACT
    PALM
    OPT
    SYNC
    LPB
    1234567812345678 
    						
    							ND-70182 (E) CHAPTER 3
    Page 315
    Revision 4.0
    PA - S D TA
    SDH/SONET Digital Trunk
    4. Lamp Indications
    Lamp indications for this circuit card are shown in the table below.
    5. Switch Settings
    Switch settings on this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    OPEGreen Remains lit while this circuit card is operating normally.
    Red Remains lit while this circuit card is in Make-busy state.
    PALM Red Lights when the OBP in this circuit card is abnormal.
    OPT Red Lights when the optical input signals are cut off.
    SYNC Red Lights when receiving 52 Mbps clock synchronization.
    LPB Green Lights when Loop-back is designated.
    AC TGreen Remains lit while this circuit card is in active state.
    Off Remains off while this circuit card is in stand-by state.
    SWITCH 
    NAMESWITCH
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    MBUP Circuit card Make-busy
    DOWN×Circuit card Make-busy cancel
    SW111OFF×Fixed
    2ON×Fixed
    3ON×Fixed
    4OFF×Fixed
    5OFF×Not used
    6ON PAD function is effective.
    OFF×PAD function is not effective.
    7ON Setting of A-law
    OFF×Setting of µ-law
    8ON ×OPT#0 Act (This card is used for System 0)
    OFF OPT#1 Act (This card is used for System 1)
    SW12 1-8 OFF×Not used
    P-SW1ON Designation of OLLPB (OPT Local Loop-back)
    OFF×Designation of OLLPB cancel
    2ON Designation of ORLPB (OPT Remote Loop-back)
    OFF×Designation of ORLPB cancel.
    3OFF×Not used
    4ON Make-busy request
    OFF×Make-busy request cancel 
    						
    All NEC manuals Comments (0)