    							CHAPTER 3 ND-70182 (E)
    Page 286
    Revision 4.0
    PA-FCHA
    Fusion Call Control Handler
    Note 2:
    Data speed 64 kbps is used for the T1 or E1 interface. 
    Data speed 56 kbps is used for the T1 interface with bit stealing.
    Data speed 48 kbps is used for the T1 interface with both bit stealing and the Zero Code
    Suppression (or Bit 7 Stuffing).   
    Note 3:When a node is set “network,” the distant node over the fusion link should be set “user,” and vice versa.
    6. External Interface
    The cable connections among the FCH, HUB, 24DTR are shown in Figure 3-71.
    Figure 3-71   FCH/HUB/DTI Connection
    24DTRFCH
    10AL (10) FLT CA
    10 BASE-T
    straight cable DTI
    FCH
    CN2
    HUB 
    						
    							ND-70182 (E) CHAPTER 3
    Page 287
    Revision 4.0
    PA-FCHA
    Fusion Call Control Handler
    See the following figure when multiple numbers of FCH circuit cards are connected to a 24DTR as a
    cascade connection. The FCH can be combined with CCH/DCH on a cascade connection.
    One DTI card can have a maximum of five (5) Handler circuits cascaded within the FCH card, the CCH
    card, and/or DCH card. Since the FCH card contains one Handler circuit per card, a maximum of five (5)
    FCH cards can be cascaded to a DTI card.
    As an example, the following (a), (b) and (c) can coexist on a cascade connection.
    (a) FCH card (One (1) Handler circuit card per card)
    (b) CCH card (Two (2) Handler circuits per card)
    (c) DCH card (Two (2) Handler circuits per card)
    Also, you must consider the cascading cable length. Note
    Figure 3-72   FCH Cascade Connection
    Note:
    A maximum cable distance between DTI and the last cascaded FCH (or CCH/DCH) is 50 cm (1’ 7.6 ”).
    24DTRFCHFCHFCH
    Max. 5  handling circuits of FCH/CCH/DCH           Note
    To the next 
    FCH/CCH/DCH
    CN2
    DTI
    FCH
    DTI
    FCH
    DTI
    FCH
    To HUB 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 288
    Revision 4.0
    PA-FCHA
    Fusion Call Control Handler
    7. Switch Setting Sheet
    SWITCH NAME SWITCH SHAPE REMARKS
    MB
    MNT
    MODE
    SW10
    SW11
    SW12
    SW13
    SW14
    ON
    ON
    OFF
    8
    1   2   3   4   5   6    7  8ON
    1   2   3   4   5   6    7  8ON
    1   2   3   4   5   6    7  8ON
    1   2   3   4   5   6    7  8ON
     1   2   3   4ON 
    						
    							ND-70182 (E) CHAPTER 3
    Page 289
    Revision 4.0
    PA - M 9 6
    HUB
    PA-M96
    HUB
    1. General Function
    This circuit card provides the repeater function which is based on ANSI/IEEE 802.3. Eight (8) of the
    10BASE-T ports are located on a HUB card. 
    As seen from the functional connection diagram below, the HUB card is located between the CPR (LANI)
    and the FCH card. The HUB card distributes the Fusion link data onto FCH cards. 
    Figure 3-73   Location of PA-M96 (HUB) Card in the System Note:  This figure shows the fusion link with full redundancy (N+1) configuration.
    CPU
    LANI
    (PZ-PC19)
    CPR #0
    CPU
    LANI
    (PZ-PC19)
    CPR #1
    TO/FROM
     THE OTHER FUSION
    NODE
    TO/FROM
    THE OTHER FUSION
    NODEDTI
    DTI FCH
    FCH HUB
    (PA-M96)
    HUB
    (PA-M96)10BASE-T cross cable is used
    for cascade connection
    10BASE-T straight cable 
    Note: This figure shows the fusion link with full redundancy (N+1) configuration. 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 290
    Revision 4.0
    PA - M 9 6
    HUB
    2. Mounting Location/Condition
    The PA-M96 (HUB) card can be mounted in any universal slot of PIM0 as shown below.
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors is shown in Figure 3-74.
    Figure 3-74   Face Layout of PA-M96 (HUB) Card 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    PIM0
    Mounting ModulePIM
    Universal SlotsUniversal Slots
    MB
    OPE
    CRS7
    CRS0
    SENS
    TP7-X
    TP6-X
    TP5-X
    TP4-X
    TP3-X
    TP2-X
    TP1-X
    TP0-X
    x
    x
    x
    x
    x
    x
    x
    x
    ST7
    ST0 
    						
    							ND-70182 (E) CHAPTER 3
    Page 291
    Revision 4.0
    PA - M 9 6
    HUB
    4. Lamp Indications
    Lamp indications for this circuit card are shown in the table below.
    Note 1:This lamp is used to indicate the status of the TPn-X port. Therefore, the circuit card operates normally
    regardless of the cable polarity.
    Note 2:This circuit card can detect data packet collisions at a TPn-X port when it would be a collision of  2048bit-
    times (2.048 ms) or when the packet collides 32 times consecutively.  The port is  then  locked-out  until the
    collision is over.
    LAMP NAME COLOR STATE
    OPE Green Remains lit while this circuit card is in normal operation.
    CRS0~CRS7 Green Lights when the circuit card detects the carrier signal form the TPn-X port. 
    ST0~ST7 GreenThe meanings of the ST0~ST7 lamps vary depending on the SEL switch settings as 
    shown in the table below.
    SEL SWITCH MEANINGS
    0Lights when the receiving pair cable polarity of the TPn-X port 
    is reversed. (n = 0~7)  Note 1
    2Lights when the 10 BASE-T (RJ-45) cable is attached to the 
    TPn-X port, and the TCP/IP link has been established. The lamp 
    may light regardless of the receiving pair cable polarity. (n = 
    0~7) 
    3Lights when the TPn-X port is normal.
    Remains off when collisions have occurred at the TPn-X port. 
    (n = 0~7) Note 2 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 292
    Revision 4.0
    PA - M 9 6
    HUB
    5. Switch Setting
    Standard settings for switches on this circuit card are shown in the table below.
     
    SWITCH 
    NAMESETTINGSTANDARD 
    SETTINGDESCRIPTION
    MBUP Circuit card Make-busy.
    DOWN×Circuit card Make-busy cancel.
    SENSE0 Polarity indication on the STn lamps for TPn-X ports (n = 0~7).
    1Not used.
    2×TPn-X ports operate as a repeater HUB. (n = 0~7).
    3Data-Packet-Collision indication on the STn lamps for TPn-X ports 
    (n = 0~7).
    4 - F Not used 
    						
    							ND-70182 (E) CHAPTER 3
    Page 293
    Revision 4.0
    PA - M 9 6
    HUB
    6. External Interface
    24DTR
    CN2FCH
    FCH
    PZ-PC19 (LANI)
    10 BASE-T straight Cable 10 BASE-T straight CableHUB
    10AL (10) FLT CA
    DTI 
    						
    							CHAPTER 3 ND-70182 (E)
    Page 294
    Revision 4.0
    PA - M 9 6
    HUB
    7. Switch Setting Sheet
    SWITCH NAME SWITCH SHAPE REMARKS
    MB
    SEL
    ON
    2 
    						
    							ND-70182 (E) CHAPTER 3
    Page 295
    Revision 4.0
    PA - 8 R S T M
    Register Sender Trunk
    PA - 8 R S T M
    Register Sender Trunk
    1. Function
    This circuit card is an 8-circuit register sender trunk card that transmits and sends selective signals (DP
    signals, PB signals, MF signals).
    Figure 3-75   Location of the PA-8RSTM Card in the System
    ATTLC
    COT
    TLT TSW
    ATIStation
    C.O. Line
    Tie Line
    RST 
    						