    							CHAPTER 2 ND-70182 (E)
    Page 26
    Revision 4.0
    SN1401 CPRAC-A
    CPU Board
    5. Switch Settings
    Note:Make-busy of this circuit card is not allowed while the Floppy Disk Drive or Hard Disk Drive is being
    accessed.
    SWITCH NAMESWITCH 
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    SW
    (PWR)—ON×PWR is supplied to the CPR.
    OFF PWR is not supplied to the CPR.
    MB 
    Note
    (FDD/HDD)—ON (Up) Make-busy of the FDD/HDD.
    OFF (Down)×Normal setting.
    MBR
    (DSP)—ON (Up)Make-busy Request of the CPR in which the 
    GT is located.
    OFF (Down)×Normal setting.
    CPURST — —Execute the CPR processing according to the 
    SENSE setting.
    SYSTEM 
    SELECT0
    (DSP)1OFF×Not used
    2OFF×Not used
    3OFF×Not used
    4ON Watchdog Timer time-out is not detected.
    OFF×Watchdog Timer time-out is detected.
    SYSTEM 
    SELECT1
    (DSP)1ON PCI Card (Slot 0) MBR ON
    OFF PCI Card (Slot 0) MBR OFF
    2ON PCI Card (Slot 1) MBR ON
    OFF PCI Card (Slot 1) MBR OFF
    3ON PCI Card (Slot 2) MBR ON
    OFF PCI Card (Slot 2) MBR OFF
    4ON PCI Card (Slot 3) MBR ON
    OFF PCI Card (Slot 3) MBR OFF
    5~8 OFF×Fixed to “OFF.”
    SYSTEM 
    SELECT2 
    (DSP)1~8 OFF×Not used 
    						
    							ND-70182 (E) CHAPTER 2
    Page 27
    Revision 4.0
    SN1401 CPRAC-A
    CPU Board
    Note:
    The SENSE switch designates the CPR processing status. The new processing status starts when the
    CPRRST switch on the DSP is pressed while setting the SENSE switch.
    6. External Interface
    See the NEAX2400 IMX Installation Manual.
    7. Switch Setting Sheet
    SWITCH 
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    SENSE 
    Note
    1The following three process are executed at the FDD/HDD.
     HD format
     File copied from FDD to HD 
     Directory created on the HD
    2×On line mode.
    3 File copied from FDD to HD within the FDD/HDD.
    4 Directory created on the HD of the FDD/HDD.
    5OAI memory clear, and the CPR starts up in ON LINE mode by loading the 
    ROM data.
    6 HD format of the FDD/HDD.
    C The CPR starts up in OFF LINE mode by loading the ROM data.
    SWITCH NAME SWITCH SHAPE REMARKS
    SW
    (PWR)
    MB
    (FDD/HDD)
    MBR
    (DSP)
    NMI-SEL
    SYSTEM 
    SELECT0
    SYSTEM 
    SELECT1
    SYSTEM 
    SELECT2
    SENSE
    ON
    OFF
    ON
    ON
    ON
    1234ON
    1234ON5678
    1234ON5678 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 28
    Revision 4.0
    PH-GT09
    Gate
    PH-GT09
    Gate
    1. General Function
    The PH-GT09 (GT) circuit card provides both the TSW I/O Local bus and the MISC bus interface. The
    CPR controls TSW, PLO, DLKC, and MISC via the ISAGT and GT.
    Figure 2-7   Location of PH-GT09 (GT) Card in the System
    PLO0
    PLO1
    TDSW03
    TDSW I/O
    Local BusTDSW I/O
    Local Bus
    TDSW13
    TDSW02
    TDSW12
    TDSW01
    TDSW11
    TDSW00
    DLKC0
    MISC
    ISAGT
    DSP
    CPULANI
    LANI
    GT
    TDSW10
    CPR #0 To HUB
    To HUBTo HUB
    To HUB
    ISAGTGTDLKC1
    DSP
    CPU
    CPR #1LANI
    LANI
    EMA
    IOC/
    MISC MISC BusMISC Bus
    MISC Bus 
    						
    							ND-70182 (E) CHAPTER 2
    Page 29
    Revision 4.0
    PH-GT09
    Gate
    2. Mounting Location/Condition
    This circuit card is mounted in the TSWM of the slot shown below.
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors is shown in Figure 2-8.
    Figure 2-8   Face Layout of PH-GT09 (GT) 00 01 02 03 04 05 06 07 08 09
    1011 12 13 14 15 16 17 18 19 20 21 22 23
    Mounting ModuleTSWM
    GT1
    GT0
    MB
    MBR OPE/MB 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 30
    Revision 4.0
    PH-GT09
    Gate
    4. Lamp Indications
    Lamp indications for this circuit card are shown in the table below.
    5. Switch Settings
    Standard settings for switches on this circuit card are shown in the table below.
    Note:Prior to extracting the GT card, flip the MBR switch on and then flip the MB switch on.
    6. External Interface
    See the NEAX2400 IMX Installation Manual.
    7. Switch Setting Sheet
    LAMP NAME COLOR STATE
    OPE/MB Green Remains lit while this circuit card is in ACT state.
    SWITCH 
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    MBUP Make-busy of circuit card
    DOWN×Normal setting
    MBR 
    NoteUPWhen the ACT side of GT’s MBR switch is flipped, the ST-BY side of 
    TSW, DLKC, and GT is forced to switch over the ACT side. (When the 
    TSW is dual configuration.)
    DOWN×Normal setting.
    SWITCH NAME SWITCH SHAPE REMARKS
    MB
    MBR
    ON
    ON 
    						
    							ND-70182 (E) CHAPTER 2
    Page 31
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    1. General Function
    The CPR consists of the following components.
    (a) CPU BOARD: Contains the Main Processor Unit (MPU), ROM, and 128 Mbyte of Random Access 
    Memory (RAM). This board may also contain the ISAGT (PZ-GT13/PZ-GT20) on 
    its Industrial Standard Architecture (ISA) bus, and LANI (PZ-PC19) on the 
    Peripheral Component Interconnect (PCI).
    (b) DSP: Contains the CPR switches and the CPR status indicator lamps.
    (c) FDD/HDD:  Floppy Disk Drive (FDD) and Hard Disk Drive (HDD) are mounted on a circuit 
    card, which, if necessary, can be extracted and/or inserted while the system is in 
    operation.
    (d) PWR:  Supplies the operating power to the CPR and also the MISC slots of the LPM.
    Figure 2-9   Location of SN1455 CPRAQ-A/SN1531 CPRAS-A (CPR) 
    LANI
    LANILANI
    LANI
    HDD
    FDDHDD
    FDD
    CPU CPUDSPDSP
    ISAGT ISAGT
    CPR#0 CPR#1To HUB
    To HUB To HUB
    To HUBTo I/O local bus
    To MISC bus 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 32
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    2. Mounting Location/Condition
    The CPR is composed of the CPU BOARD, DSP, FDD/HDD, and PWR and is located in the Local
    Processor Module (LPM) as shown in Figure 2-10. Since the CPR provides the Industrial Standard
    Architecture (ISA) bus and Peripheral Component Interconnect (PCI) bus, the ISAGT and LANI cards are
    located in those busses respectively. 
    Figure 2-10   CPR Location
    PZ-GT20 (ISAGT) Note
    CPU BOARD
    PZ-DK224 (DSP)PZ-PC19
     (LANI)
    PZ-GT13
     (ISAGT)
    PZ-IO27(FDD/HDD) PZ-PC19 (LANI) 
    PZ-PW92 (PWR)
    CPR LPM
    ISWM/PIM0
    BSCM
    Note:This card is mounted in the IMG0 of the IMX-U system only. 
    						
    							ND-70182 (E) CHAPTER 2
    Page 33
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    3. Face Layout of Lamps, Switches, and Connectors
    The CPR contains the following lamps, switches and connectors.
    Slots 0-3 provide the Peripheral Component Interconnect (PCI) bus, and Slots 4-6 are the Industrial
    Standard Architecture (ISA) bus.
    Figure 2-11   Front View of CPR
    4. Lamp Indications
    Lamp Indications vary depending on the node. The following shows the lamp indications for the CPR in
    the IMG.
    LAMP NAME COLOR DESCRIPTION
    ON (PWR) Green Lights green when the PWR is supplied.
    ALM (PWR) Red Lights red when the PWR is abnormal.
    HDD
    (FDD/HDD)Red Lights red while the HDD or FDD is being accessed.
    WDT (DSP) Red Lights red when Watch-dog Timer (WDT) time-out has occurred.
    CPU OPE (DSP) Green Lights green when the CPU is in active state.
    CPU OPE (DSP) Green Lights green when the CPU is in active state.
    SW DC-40V~-58.6VPZ-PW92
    MBRCPU OPE
    ON HDD-48V OUTON
    OFF
    5A
    125V
    AC/DC I
    O
    PALM
    ON
    ALM OUTPWR
    INPWR
    ON
    14
    IMG1
    SYSTEM SELECT0 STATUS
    SENSE
    CPURST
    SLOT NO. 0 1 2 3 4 5 6
    WDT
    IMG2
    IMG0AB
    IMG3
    ON
    112SYSTEM SELECT1
    ON
    13 20SYSTEM SELECT2
    PWR(PZ-PW92)
    FDD/HDD(PZ-IO27)DSP(PZ-DK224)
    Note
    Note:This card is mounted in the IMG0 of the IMX-U system only. 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 34
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    Note:
    No lamp indication in STBY mode.
    The following shows the lamp indication for the CPR in the ISW
    Note:No lamp indication in STBY mode.
    IMG0 (DSP) Green Flashes green when PZ-GT13 (located in slot number 6) is in operation.
    IMG1 (DSP) Green Flashes green when IMG1 is mounted. Note
    IMG2 (DSP) Green Flashes green when IMG2 is mounted. Note
    IMG3 (DSP) Green Flashes green when IMG3 is mounted. Note
    LAMP NAME COLOR DESCRIPTION
    ON (PWR) Green Lights green when the PWR is supplied.
    ALM (PWR) Red Lights red when the PWR is abnormal.
    HDD (FDD/HDD) Red Lights red while the HDD or FDD is being accessed.
    WDT (DSP) Red Lights red when Watch-dog Timer (WDT) time-out has occurred.
    CPU OPE (DSP) Green Lights green when the CPU of the ISW is in active state.
    IMG0 (DSP) GreenLights green when the CPU of the ISW is in active state.
    Flashes green when the CPU of the ISW is in stand-by state.
    IMG1 (DSP) Green Lights green when the TSW1 of the ISW is used. Note
    IMG2 (DSP) Green Lights green when the TSW2 of the ISW is used. Note
    IMG3 (DSP) Green Lights green when the TSW3 of the ISW is used. Note LAMP NAME COLOR DESCRIPTION 
    						
    							ND-70182 (E) CHAPTER 2
    Page 35
    Revision 4.0
    SN1455 CPRAQ-A/SN1531 CPRAS-A
    CPU Board
    Note:
    The segment spinning indication shows a processing status has completed successfully, or indicates “E”
    meaning the processing failed.
    LAMP
    NAMEDESCRIPTION
    STATUS
    (DSP)Two sets of “7-segment LED” show the CPR processing status. The CPR processing status is determined by the 
    SENSE switch settings, and the new processing status starts when the CPURST switch is pressed. The 7-segment 
    LED indication on each CPR processing status is listed below.
    SENSESTATUS
    DESCRIPTION
    LEFT RIGHT
    1Not used“F”
    “c”
    “d”1. When Program Install
    The HD in the CPR is initialized and the program is installed. (These three 
    processes execute) 
    “F” indicated during HD format.
    “c” indicated when copying data from FD to HD 
    “d”  indicated while making the directory on the HD
    Not used “1”2. When Program Load 
    After program installation, the program should be transferred from the HD 
    to memory. 
    “1”  is indicated during this process.
    2“0-9” “0-9”3.  On-line active CPR 
    The active CPR which is in ON LINE status indicates the CPU occupancy 
    rate by percentage. (00-99%)
    Not used “S”
    “b”
    “y”4.  On-line stand-by CPR 
    The stand-by CPR which is in ON LINE status indicates “S,” “b,” “y”
    Not used5. Program & Office data load 
    “1” indicated during the Program and Office data transfer from the HD to 
    the memory
    “0”  indicated during the Office data load
    3 Not used “c” “c” indicated when copying the data from FD to HD
    4 Not used “d” “d” indicated while making the directory on the HD
    5 Not usedThe CPR is starting-up with ON LINE (OAI memory clear restart).
    “1” indicated during the Program load.
    “0” indicated during the process.
    6 Not used “F” “F”  indicated during HD format.
    C Not used  “H”The CPR is starting-up OFF LINE. 
    “H” indicated during the ROM data loading.
    “1”
    “0”
    “1”
    “0”
    Segment Spinning Indication 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx Circuit Card Manual