    							CHAPTER 2 ND-70182 (E)
    Page 116
    Revision 4.0
    PH-SW12
    Time Division Switch
    The TONE ROM located on this circuit card contains the audible tones, such as Dial Tone, Busy Tone, Ring
    Back Tone, etc. The music on hold source, either the MUSIC ROM or the external source via FM lead, is
    located on the PLO card. The tone and the music are inserted into their time slot at this circuit card.
    Additionally, this circuit card provides the Voice Prompt function that inserts the designated time slot of
    PCM (Speech Path Memory : SPM) into the tone or music time slot.
    Figure 2-55   Music/Tone Insertion
    SELSEL
    SEL
    Speech Path Memory
    for Music/Tone
    Music/Tone
    MUSIC ROM
    TDSW00PLO#0
    TONE ROM
    SELSEL
    SEL
    Speech Path Memory
    for Music/Tone
    Music/Tone
    MUSIC ROM
    TDSW1PLO#1
    TONE ROM
    FMFM 
    						
    							ND-70182 (E) CHAPTER 2
    Page 117
    Revision 4.0
    PH-SW12
    Time Division Switch
    Figure 2-56   Speech Path Memory (SPM) for Voice Prompt Function
    2. Mounting Location/Condition
    This circuit card is mounted in the TSWM of the slot shown below. The IMX-U system accommodates two
    TSWMs (TSWM0/1).
    PIM 3
    [SPM for music channel 16-29]
    MG = 01, Unit = 2, Group = 24, Level = 0-7
    MG = 01, Unit = 2, Group = 25, Level = 0-5
    PIM 2
    [SPM for music channel 0-15]
    MG = 01, Unit = 0, Group = 24, Level = 0-7
    MG = 01, Unit = 0, Group = 25, Level = 0-7
    PIM 1
    [SPM for tone channel 16-31]
    MG = 00, Unit = 2, Group = 24, Level = 0-7
    MG = 00, Unit = 2, Group = 25, Level = 0-7
    PIM0
    [SPM for tone channel 0-15]
    MG = 00, Unit = 0, Group = 24, Level = 0-7
    MG = 00, Unit = 0, Group = 25, Level = 0-7
    Note :Note
    MG = 01,Unit = 2, Group = 25, Level = 6-7 are exclusively used by the DLKC.
    00 01 02 03 04 05 06 07 08 09 10 111213141516171819 20 21 22 23
    Mounting ModuleTSWM
    TSW 00 TSW 01 TSW 02 TSW 03
    TSW 10 TSW 11 TSW 12 TSW 13
    TSWM 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 118
    Revision 4.0
    PH-SW12
    Time Division Switch
    The definition of the TSW00 - TSW03/TSW10 - TSW13 are listed below.
    4-IMG System
    IMX-U system
    This card is mounted in the TSWM0/1 for the IMX-U system.
    For the card in TSWM0 
    For the card in TSWM1
    SYMBOL SYSTEM CONTROLLED IMG
    TSW00
    0IMG 0
    TSW01 IMG 1
    TSW02 IMG 2
    TSW03 IMG 3
    TSW10
    1IMG 0
    TSW11 IMG 1
    TSW12 IMG 2
    TSW13 IMG 3
    SYMBOL SYSTEM FUNCTION CONTROLLED IMG
    TSW00
    0Collects the PCM dataIMG 0
    TSW01IMG 1
    TSW02
    Sends the PCM data to the ISWIMG 0
    TSW03IMG 1
    TSW10
    1Collects the PCM dataIMG 0
    TSW11IMG 1
    TSW12
    Sends the PCM data to the ISWIMG 0
    TSW13IMG 1
    SYMBOL SYSTEM FUNCTION CONTROLLED IMG
    TSW00
    0Collects the PCM dataIMG 2
    TSW01IMG 3
    TSW02
    Sends the PCM data to the ISWIMG 2
    TSW03IMG 3 
    						
    							ND-70182 (E) CHAPTER 2
    Page 119
    Revision 4.0
    PH-SW12
    Time Division Switch
    3. Face Layout of Lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors is shown below.
    Figure 2-57   Face Layout of PH-SW12 (TSW) TSW10
    1Collects the PCM dataIMG 2
    TSW11IMG 3
    TSW12
    Sends the PCM data to the ISWIMG 2
    TSW13IMG 3 SYMBOL SYSTEM FUNCTION CONTROLLED IMG
    MB
    TSWMBR TSWACT
    M3SY
    M2SY 
    M1SY
    M0SY
    PLO 1
    PLO 0
    TONE 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 120
    Revision 4.0
    PH-SW12
    Time Division Switch
    4. Lamp Indications
    Lamp indications for this circuit card are shown in the table below.
    5. Switch Settings
    Standard settings for switches on this circuit card are shown in the table below.
    6. External Interface
    See  the NEAX2400 IMX Installation Manual for information about the cable connection to MUX.
    LAMP NAME COLOR STATE
    TSWACTGreen Remains lit while the TSW block is in ACT state.
    Red Remains lit while the TSW block is in Make-busy state.
    Off Remains off while the TSW block is ST-BY side.
    M3SY Green Lights when MUX #3 synchronization has been established.
    M2SY Green Lights when MUX#2 synchronization has been established.
    M1SY Green Lights when MUX#1 synchronization has been established.
    M0SY Green Lights when MUX#0 synchronization has been established.
    PLO 1 Green Lights when the Frame Head signal and clock signals are received from the PLO 1.
    PLO 0 Green Lights when the Frame Head signal and clock signals are received from the PLO 0.
    SWITCH
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    MBUP Circuit card Make-busy.
    DOWN×Circuit card Make-busy cancel.
    TSWMBRUP TSW Make-busy request.
    DOWN×TSW Make-busy request cancel.
    SWITCH 
    NAMESWITCH
    NO.SETTINGSTANDARD 
    SETTINGMEANING
    TONE1OFF×Fixed.
    2ON (The last byte data of the DTG ROM is “FE.”)
    OFF×(The last byte data of the DTG ROM is “FF.”) 
    						
    							ND-70182 (E) CHAPTER 2
    Page 121
    Revision 4.0
    PH-SW12
    Time Division Switch
    7. Switch Setting Sheet
    SWITCH NAME SWITCH SHAPE REMARKS
    MB
    TSWMBR
    TONE
    ON
    ON
    12ON 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 122
    Revision 4.0
    PU-SW00
    Time Division Switch
    PU-SW00
    Time Division Switch
    1. General Function
    The PU-SW00 circuit card provides the Time division Switch (TSW) and INT function for the IMX-U
    system. Each circuit card provides switching for a Local Node (LN) and four PU-SW00 cards and two PU-
    SW01 (HSW) cards achieve a maximum of 32,768 time slot (TS) switching for four (4) LNs. This circuit
    card is located in ISWM of the ISW. 
    Figure 2-58   Location of PU-SW00 (TSW) (1/2)
    MUX00
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    DLKC0
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    LC/TRK
    MUX01
    MUX02
    MUX03
    MUX10
    MUX11
    MUX12
    MUX13
    TSW00
    TSW10
    TSW01
    TSW11
    TSW02
    TSW12
    TSW03
    TSW13
    PLO 0
    PLO 0
    DLKC1
    PLO 1
    PLO 1
    MUX
    MUX
    TSW00
    TSW01
    TSW02
    TSW03HSW00
    HSW01HSW10
    HSW11TSW10
    TSW11
    TSW12
    TSW13
    TSW Configuration
    2M  PCM  HW  x8
    2M  PCM  HW  x8
    2M  PCM  HW  x8
    2M  PCM  HW  x82M  PCM  HW  x8
    2M  PCM  HW  x8
    2M  PCM  HW  x8
    2M  PCM  HW  x8
    32M  TSW
    Matrix HW32M  SERIAL  HW
    32M  SERIAL  HW
                          x4
    32M  SERIAL  HW
                          x432M  SERIAL  HW
                          x4
    32M  SERIAL  HW
                          x4
    64KHz
    Clock 64KHz
    Clock32M  TSW
    Matrix HW
    32.768MHz  Clock
                              DCS     32.768MHz  Clock
    DCS
    32.768MHz  Clock32.768MHz  Clock 
    						
    							ND-70182 (E) CHAPTER 2
    Page 123
    Revision 4.0
    PU-SW00
    Time Division Switch
    Figure 2-59   Location of PU-SW00 (TSW) (2/2)
    2. Mounting Location/Condition
    This circuit card can be mounted in the shaded slots shown below.
    HSW01
    HSW00
    TSW03
    TSW02
    TSW01
    TSW00
    LANI
    LANI
    LANI
    LANI
    HSW11
    HSW10
    TSW13
    TSW12
    TSW11
    TSW10
    PLO 1
    PLO 0
    RES
    CPUCPU
    MISC
    IOC
    EMARES
    RESRES
    IOGT1
    IOGT0
    ISAGTISAGT
    MISC I/O BUSISAGT BUS ISAGT BUSLPM TSW I/O BUS TSW I/O BUSISWM [INT Configuration]
    00 01 02 0304050607 08 09 10 11 12 1314151617 18 19 20 21 22 23
    Mounting ModuleISWR
    TSW (00) TSW (01) TSW (02) TSW (03) TSW (10) TSW (11)
    TSW (12) TSW (13) 
    						
    							CHAPTER 2 ND-70182 (E)
    Page 124
    Revision 4.0
    PU-SW00
    Time Division Switch
    3. Face Layout of lamps, Switches, and Connectors
    The face layout of lamps, switches, and connectors is shown in Figure 2-60.
    Figure 2-60   Face Layout of PU-SW00 (TSW)
    4. Lamp Indications
    Lamp indications for this circuit card are shown in the table below.
    LAMP NAME COLOR STATE
    TSWACTGreen Lights when the TDSW block is active.
    Red Lights when the TDSW block is in Make-busy state.
    PWPALM Red Lights when the On-Board Power Supply (+5V) for this circuit card is abnormal.
    HCKALM Red Lights when clock failure (clock down or FH output failure) occurs on the HSW card.
    LN33 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN32 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN31 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN30 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    TSW MB
    TSW MBR
    TSWACT
    1234
    PWPALM
    HCKALM
    LN33
    LN32
    LN31
    LN30
    LN23
    LN22
    LN21
    LN20
    LN13
    LN12
    LN11
    LN10
    LN03
    LN02
    LN01
    LN00
    SWE5 
    						
    							ND-70182 (E) CHAPTER 2
    Page 125
    Revision 4.0
    PU-SW00
    Time Division Switch
    5. Switch Settings
    Switch settings for this circuit card are shown in the table below.
    6. External Interface
    See the NEAX2400 IMX Installation Manual. 
    LN23 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN22 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN21 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN20 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN13 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN12 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN11 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN10 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN03 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN02 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN01 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    LN00 Green Lights when this circuit card is synchronized with the corresponding TSW/MUX of LN.
    SWITCH
    NAMESETTINGSTANDARD 
    SETTINGMEANING
    TSW MBUP Circuit card Make-busy.
    DOWN×Circuit card Make-busy cancel.
    TSW MBRUP Circuit card Make-busy request.
    DOWN×Circuit card Make-busy request cancel.
    SWITCH 
    NAMESWITCH
    NO.SETTINGSTANDARD
    SETTINGMEANING
    SWE51ON×Local Node connection mode.
    OFF MUX connection mode.
    2OFF×Not used
    3OFF×Not used
    4OFF×Not used LAMP NAME COLOR STATE 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx Circuit Card Manual