CHAPTER 3 ND-70182 (E) Page 206 Revision 4.0 PH-CK17-A Phase Lock Oscillator Figure 3-31 shows an example of distributing clock from a digital interface. This figure assumes that the Digital Trunk POUT leads are used as the first clock distribution route. Figure 3-31 Cable Connection Diagram (4-IMG System/LN) for Receiving Clock from Digital Interface DIU0A1 DIU0B1 DIU1A1 DIU1B1 DIU2A1 DIU2B1 DIU3A1 DIU3B1 DIU0A0 DIU0B0 DIU1A0 DIU1B0 DIU2A0 DIU2B0 DIU3A0 DIU3B0 RA RB TA TB POUT A POUT BPCM Cable (2P) to other nodePCM Carrier Equipment DSU CLK Note 1:Note 2 Note 1 PLO has a maximum of 4 inputs. DIU0xx leads are used for the 1st clock distribution routes. DIU3xx leads are used for the 4th. The first input has the highest priority. Note 2:The connection is required for a dual PLO system. MDF maximum 100 meters (330 feet) (24AWG) Installation Cable LT Connector Installation Cable Installation Cable EXCLK1PLO#1 EXCLK0PLO#0 Digital Interface IMG1 maximum 200 meters (660 feet) (24 AWG)
ND-70182 (E) CHAPTER 3 Page 207 Revision 4.0 PH-CK17-A Phase Lock Oscillator Figure 3-32 Connection of External Music-On-Hold 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE MB SW01 SW02 SW03 SW10 SW11 SW12 ISW-LN PLO CA-A cable/ 34PH ISWM EXCLK CA-A Pin Assignment PIN No. 26 27 28 29 30 31 32 33LEAD NAME FM1 FM0LEAD NAME E E PIN No. 1 2 3 4 5 6 7 8 9MUSIC SOURCE MDFISW-LN PLO CA-A / 34PH ISWM EXCLK CA-A and Installation Cable(25P) Multiple connections between the systems 0 and 1 are required on the MDF. Note Note: FM1 is not used at this time. ON 1234ON5678 1234ON5678 12ON 1ON234 1234ON5678
CHAPTER 3 ND-70182 (E) Page 208 Revision 4.0 PH-CK18 Clock PH-CK18 Clock 1. General Function This circuit card is used for the Local Node of the IMX-U system. The main function of this circuit card is to supply basic clock signals to the system. This card receives clock signals from the Phase Lock Oscillator (PLO) located in TSWM0 of IMG1, distributing the following signals to the Time Division Switch (TSW) located in TSWM1 of IMG2. 32.768 MHz CLK 8 KHz FH 5 msec × “n” FH (for Wireless System)
ND-70182 (E) CHAPTER 3 Page 209 Revision 4.0 PH-CK18 Clock Figure 3-33 Location of PH-CK18 (CLK) LN0 (IMG2/IMG3)LN3 (IMG2/IMG3) 32M, FH+WFH PLO ACT32M, FH+WFH PLO ACT CLK1 (TSWM1) TSW 10~13 CLK0 (TSWM1) TSW 00~03 MUX (System1)MUX (System0) LC/TRK HSW00 ISW HSW01 CLK1 (TSWM1) TSW 10~13 CLK0 (TSWM1) TSW 00~03 MUX (System1)MUX (System0) LC/TRK LN0 (IMG0/IMG1)from LN DTIfrom LN DTI 32M, FH+WFH PLO ACT32M, FH+WFH PLO ACT (BWB)32M, FH+WFH PLO ACT (BWB) 64K+FH, WFH TSW ACT (Cable)64K+FH, WFH TSW ACT (Cable) PLO 1 (TSWM0) TSW 10~13 PLO 0 (TSWM0) TSW 00~03 MUX (System1)MUX (System0) LC/TRK LN3 (IMG0/IMG1) 32M, FH+WFH PLO ACT PLO 1 (TSWM0) TSW 10~13 PLO 0 (TSWM0) TSW 00~03 MUX (System1)MUX (System0) LC/TRK TSW00 TSW03HSW10 OSC64K+8K (BWB) (BWB) CLK, FH, WFH ACT, ALM PLO 0 DTI0 DCS0 (MDF) DCS1123 PLO 1 SEL PLL Drv HSW11 TSW10 TSW13 SEL PLL Drv OSC ~ ~~ ~
CHAPTER 3 ND-70182 (E) Page 210 Revision 4.0 PH-CK18 Clock 2. Mounting Location/Condition Mounting locations for this circuit card are shown below. 3. Face Layout of Lamps, Switches, and Connectors The face layout of each lamp and switch on this circuit card is shown in Figure 3-34. Figure 3-34 Face Layout of PH-CK18 (CLK) 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 2223 Mounting ModuleTSWM1 (IMG2) CLK (#1) CLK (#0) MB OPE ALM0 ALM1 PALM
ND-70182 (E) CHAPTER 3 Page 211 Revision 4.0 PH-CK18 Clock 4. Lamp Indications Lamp indications for this circuit card are shown below: 5. Switch Settings Switch settings for this circuit card are shown below. LAMP COLOR MEANING OPE Green Lights when this circuit card is in ACT state. ALM 0 Red Lights when clock signal failure has occurred. ALM 1 Red Lights when Frame Head signal failure has occurred. PALM Red Lights when the On Board Power Supply failure has occurred. SWITCH NAMESETTINGSTANDARD SETTINGMEANING MBON Circuit card Make-busy. OFF×Circuit card Make-busy cancel.
CHAPTER 3 ND-70182 (E) Page 212 Revision 4.0 PH-CK18 Clock 6. External Interface Figure 3-35 LT Connector Lead Location (ISW-LN0) 7. Switch Setting Sheet SWITCH NAME SWITCH SHAPE REMARKS MB PIM CLK00 (Slot No.08) CLK10 (Slot No.12) TSWM1 TSWM0 ISWM Installation Cable DIU Connection Note MDF To Digital Interface and/or DCS EXCLK0 (Slot No.21) PLO CLOCK0 (Slot No.21) EXCLK1 (Slot No.23) PLO CLOCK1 (Slot No.23)PLO CLOCK0 (Slot No.21)PLO CLOCK1 (Slot No.23) ISW-LN PLO CA-A PLO-CLK CA-A DCS Connection Note:For DIU connection route diagram, see the figure on the next page. 261 LEAD NAMELEAD NAME 272 283 PIN No. PIN No. 294 305 316 327 338 349 3510 DIU 3B DIU 2BDIU 3A DIU 2A DIU 1B DIU 1A DIU 0B DIU 0A ON
ND-70182 (E) CHAPTER 3 Page 213 Revision 4.0 PA - C S 0 8 Hotel Attendant Interface PA - C S 0 8 Hotel Attendant Interface 1. General Function This circuit card is the Hotel Attendant Console (Hotel ATTCON) interface card that supports the interface function for the Hotel ATTCON (maximum two sets of Hotel ATTCON per card), PM function (controlling of Hotel ATTCON and exchanging of control commands with the CPU), PB/DP sending function (sending of PB signals or DP signals under control of the PM), receiving data (Hotel ATTCON Call Termination Information) link interface function, etc. Figure 3-36 Location of PA-CS08-B (HMATI) Card in the System 2. Mounting Location/Condition The PA-CS08-B (HMATI) card can be mounted in the shaded slots as shown below. CPU GTTDSW MUX 2M PCM Highway PM Bus ATTENDANT CONSOLE (×2) : Control Line : Speech Path IO Local Bus : Input Output Local Bus PM Bus : Port Microprocessor Bus HMATI 00 01 02 03 04 05 06 07 08 09 10 1112 13 14 15 16 17 18 19 20 21 2223 Mounting ModulePIM HMATI HMATI
CHAPTER 3 ND-70182 (E) Page 214 Revision 4.0 PA - C S 0 8 Hotel Attendant Interface 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors on this circuit card is shown in Figure 3-37. Figure 3-37 Face Layout of HMATI Card 4. Lamp Indications Lamp indications for this circuit card are shown in the table below. LAMP COLOR STATE OPE Green Remains lit while this circuit card is operating. N-OPE Red Remains lit while this circuit card is in Make-busy state. BLS0 BLS1Red Lights when the corresponding circuit is busy. BlinkBlinks when the corresponding circuit is busy. Note:The lamp also blinks when dial signals are being sent out. OPE N-OPE MB FU0 (Note ) SW11 BLS1 BLA1 BLA0 SW04 SW03 SW02 SW08 SW07 SW09 SW12 3210 FU1 (Note) BLS0 Note:When extracting/inserting this card, care should be taken as to the FU0, FU1. ➀ MB key → ON ➁ Remove the FU0 and FU1. ➂ Extract this card. ➀ Mount this card without the FU0 and FU1. ➁ Plug in the FU0 and FU1. ➂ MB key → OFF
ND-70182 (E) CHAPTER 3 Page 215 Revision 4.0 PA - C S 0 8 Hotel Attendant Interface 5. Switch Settings Standard settings for various switches on this circuit card are shown in the table below. BLA0 BLA1Red Lights when the corresponding circuit is busy. Blink Blinks when the corresponding circuit is in Make-busy state. SWITCHSWITCH NO.SETTINGSTANDARD SETTINGMEANING MBUP Circuit card Make-busy. DOWNCircuit card Make-busy cancel. SW02 (TAS0) SW03 (TAS1)1 2 3 4 SW041ON ×Fixed 2OFF ×Fixed 3ON ×Fixed 4OFF ×Fixed SW07 (TAS0) SW08 (TAS1)1 2 3 4 LAMP COLOR STATE SETTING OF TAS SIGNALLING SYSTEM SWITCH TAS (A WIRE) TAS (B WIRE) 1-48VG 2CRG 3GG 4 LOOP LOOP SETTING OF TAS CURRENT LIMIT RESISTANCE SW7-1/ SW8-1SW7-2/ SW8-2SW7-3/ SW8-3SW7-4/ SW8-4RESISTANCE ON OFF ON OFF ON OFF ON OFFON ON OFF OFF ON ON OFF OFFON ON ON ON OFF OFF OFF OFFOFF OFF OFF OFF OFF OFF OFF OFF0 Ω ΩΩ Ω 200 Ω ΩΩ Ω 390 Ω ΩΩ Ω 590 Ω ΩΩ Ω 820 Ω ΩΩ Ω 1020 Ω ΩΩ Ω 1210 Ω ΩΩ Ω 1410 Ω ΩΩ Ω