Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual

Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 484
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    403 South Africa 
    Feature Administration
    The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e 
    ap p roval was award ed . The sc reens may have c hang ed  sinc e that d ate.
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nARS/AAR Ad ministration
    To enab le ARS administration, on the System-Parameters 
    Customer-Op tions sc reen, set the ARS
     field  to y
    . You also should check all 
    ARS/AAR d efaults. All d efault ARS analysis c odes are deleted  b efore 
    d ialed  strings are ad d ed for routing when DEFINITY is installed  outsid e of 
    North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing 
    p rob lems. In p artic ular, the following  c all typ es (ap pear as ARS/AAR 
    d efaults) typ ic ally are not used  in non-North Americ an ARS/AAR tab les:
    Luc ent rec ommend s only the following  c all typ es b e used  outside North 
    Americ a: 4 Wire Digital Line > TN754B 
    2 Wire Digital Line #TN2224 > TN2181 
    Data Line > TN726B 
    BRI-U Line
    BRI-ST Line
    fnp a: North Americ an numb ers with an area c od e.
    hnp a: North Americ an numb ers without an area c od e.
    svc : North Americ an numb ers of the screen ‘‘x11’’.
    int: For all international numbers.
    natl: For all national PN numb ers.
    pubu: For all other external (that is, not extensions) numbers.
    Ta b l e  5 3 .Recommended and Available CPs in South Africa — Continued
    Equipment Equipment Type
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    404 South Africa 
    System Parameter Administration
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nFeature-Related System Parameters Ad ministration
    change system-parameters features                              Page   1 of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
                                     Trunk-to-Trunk Transfer: none
     Coverage Subsequent Redirection   No Answer Interval: 2
               Coverage - Caller Response Interval (seconds): 4
                             Keep Held SBA at Coverage Point? y
     Automatic Callback - No Answer Timeout Interval (rings): 3
                        Call Park Timeout Interval (minutes): 10
    Off-Premises Tone Detect Timeout Interval (seconds): 20
                                  AAR/ARS Dial Tone Required? y
                                          Music/Tone on Hold: none
               Music (or Silence) on Transferred Trunk Calls? no
                            DID/Tie/ISDN Intercept Treatment: 2500
                   Messaging Service Adjunct (MSA) Connected? n
      Internal Automatic Answer for Attendant Extended Calls? n
                   Automatic Circuit Assurance (ACA) Enabled? n
    change system-parameters features                              Page   2 of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
     LEAVE WORD CALLING PARAMETERS
        Maximum Number of Messages Per Station (when MSA not in service): 10
        Stations with System-wide Retrieval Permission (enter extension)
          1:         3:         5:         7:          9:
          2:         4:         6:         8:         10:
     
           WARNING:   SEE USER DOCUMENTATION BEFORE CHANGING TTI STATE
                       Terminal Translation Initialization (TTI) Enables? n
       
       SECURITY VIOLATION NOTIFICATION (SVN) PARAMETERS HAVE MOVED TO 
       THE SYSTEM-PARAMETERS SECURITY SCREEN 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    405 South Africa 
    change system-parameters features                              Page   3 of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
     
                         Reserved Slots for Attendant Priority Queue: 5
                                          Time before Off-hook Alert: 10
                              Emergency Access Redirection Extension: 
                                      Service Observing Warning Tone? y
                                                Call Pickup Alerting? y
                   Deluxe Paging and Call Park Timeout to Originator? n
       Controlled Outward Restriction Intercept Treatment: tone
      Controlled Termination Restriction (Do Not Disturb): tone
               Controlled Station to Station Restriction : tone
     AUTHORIZATION CODE PARAMETERS       Authorization Codes Enabled: n
    change system-parameters features                              Page   4 of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
      SYSTEM PRINTER PARAMETERS
                   System Printer Extension                       Lines Per Page: 60
                        EIA Device Bit Rate: 9600
      SYSTEM-WIDE PARAMETERS
                                 Switch Name:
      CALL CENTER SYSTEM PARAMETERS
                                                 Direct Agent Announcement Delay:
                                                       Converse First Data Delay: 0
        Direct Agent Announcement Extension:          Converse Second Data Delay: 2
      CALL MANAGEMENT SYSTEM PARAMETERS
                      BCMS Measurement Interval: hour
      BCMS/VuStats Abandon Call Timer (seconds): 
                ACD Login Identification Length: 0           Adjunct CMS Release:
      MALICIOUS CALL TRACE PARAMETERS
                     Apply MCT Warning Tone? n    MCT Voice Recorder Trunk Group: 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    406 South Africa 
    nSystem Parameter Multifreq uenc y Sig naling  Ad ministration
    — Incoming Call Type: group-ii-mfc
    — Outgoing Call Type: group-ii-mfc
    — Maintenanc e Call Typ e: none
    — Test Call Extension: Ac c ept d efault
    — Interdigit Timer (sec): 15
    — Outg oing  Forward  Signal Present Timer (sec ): 20 
     system-parameters features                              Page   5 of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
                        Public Network Trunks on Conference Call: 1
                   Conference Parties with Public Network Trunks: 3
                Conference Parties without Public Network Trunks: 6
                        Night Service Disconnect Timer (seconds): 180
                                Short Interdigit Timer (seconds): 3
    Unanswered DID Call Timer (seconds):
                             Line Intercept Tone Timer (seconds): 30
                                                      Auto Start? y
                                                       Auto Hold? y
                                                  Attendant Tone? y
                                                   Bridging Tone? y
                                                 Conference Tone? n
                                                  Intrusion Tone? y
                                              DID Busy Treatment: tone
      DISTINCTIVE AUDIBLE ALERTING
                           Internal: 2    External: 2    Priority: 3
    display system-parameters features                             Page  6   of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
                                                          Pull Transfer: n
                                                Level Of Tone Detection: medium
                                          Wait Answer Supervision Timer? y
                                           Repetitive Call Waiting Tone? y
    Repetitive Call Waiting interval (sec): 4
    Outpulse Without Tone? y
    Network Feedback During Tone Detection? y
                          Intercept Treatment On Failed Trunk Transfers? n
                                          Vector Disconnect Timer (min):
                                   Station Busy Tone Forward Disconnect: intercept
      RECALL TIMING
             Flashhook Interval? y                   Upper Bound (msec): 600
                                                     Lower Bound (msec): 200
     ENHANCED DCS
           Enhanced DCS Enabled? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    407 South Africa 
    — Outg oing  Forward  Signal Ab sent Timer (sec ): 30
    — Multifreq uenc y Sig naling  Inc oming  Interc ept Treatment?: n
    — Received Signal Gain (-Loss) (dB): 0
    — Transmitted  Sig nal Gain (-Loss) (dB): -3
    —ANI Prefix:
    — ANI for PBX:
    — Next ANI Dig it: send -ani
    — Collec t All Dig its Before Seizure? n
    — Inc oming  Forward  Signal Typ es:
    GROUP-I GROUP-II GROUP-A GROUP-B
    11: ig nored
    12: ig nored 
    13: ig nored 
    14: ig nored 
    15: end -of-d ial1: normal
    2: normal
    3: normal 
    4: normal 
    5: normal
    6: normal
    7: normal 
    8: normal 
    9: normal 
    10: normal 
    11: normal
    12: normal
    13: normal 
    14: normal 
    15: normal1: next-d ig it 
    3: end -of-dial3: b usy
    5: c ong estion
    6: free 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    408 South Africa 
    — Outgoing Forward Signal Types:
    nSystem Parameter Country Op tions Ad ministration
    — Comp and ing  Mode: A-law
    — Base Tone Generation Set: 13
    — 440Hz PBX-d ial Tone? n
    — 440Hz Sec ond ary-dial Tone? n
    — Dig ital Loss Plan: 13
    — Analog ue Ring ing  Cad enc e: 10
    — Tone Detec tion Mod e: 5
    — Interd ig it Pause: long
    — Dial Tone Valid ation Timer: 600ms
    — Analog  Ring ing  Cad enc e: 10
    — Customized  tone d efinitions follow the syntax as sp ec ified :
    [ (Freq uenc y/Level)|silenc e|g oto)] [ (Duration ms)|(Step)]
    nRingback:
    — (375+ 425/-15.0)(400) GROUP-I GROUP-II GROUP-A GROUP-B
    15: end -of-d igits
        :
        :
        :
        :2: normal 
    5: attend ant 
    6: d ata-c all
       :
       :
       :
       :
       :
       :
       :
       :
       :
       :
       :
       :1: next-d ig it 
    2: c ong estion
    3: end -of-d ial
    4: c ong estion
    5: c all-info-ani
    6: setup-sppath
    7: last-2-d ig its
    8: last-3-d ig its
    9: c ong estion
    10: c ong estion
    11: c ong estion
    12: c ong estion
    13: c ong estion
    14: c ong estion
    15: c ong estion1: free 
    2: c ong estion
    3: b usy 
    4: c ong estion
    5: c ong estion 
    6: free 
    7: interc ep t
    8: c ong estion
    9: c ong estion 
    10: c ong estion
    11: c ong estion
    12: c ong estion
    13: c ong estion
    14: c ong estion
    15: c ong estion 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    409 South Africa 
    — (silence)(200)
    — (375+ 425/-15.0)(400)
    — (silenc e)(2000)
    — (go to)(1)
    nSec ond ary-Dial:
    — (375+ 425/-15.0)(50)
    — (go to)(1)
    nBusy:
    — (404/-11.0)(500)
    — (silence)(500)
    —(goto)(1)
    nInterc ept:
    — (404/-11.0)(2500)
    — (silence)(500)
    —(goto)(1)
    nRe o rd e r :
    — (404/-11.0)(250)
    — (silence)(250)
    —(goto)(1)
    Trunk Administration
    nBothWay CO Trunk
    — Trunk Gain: low
    — RA Trunk Loss: 0d B
    — Make/Break Ratio: 35/65 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    410 South Africa 
    change trunk-group 1                                          Page   1 of  10
                                     TRUNK GROUP
     Group Number: 1                   Group Type: co            CDR Reports: y
       Group Name: OUTSIDE CALL               COR: 1                     TAC: 30
        Direction: two-way       Outgoing Display? n
      Dial Access? y               Busy Threshold: 99          Night Service:
     Queue Length: 0                      Country: 13   Incoming Destination: 2100
        Comm Type: voice                Auth Code? n   Digit Absorption List:
         Prefix-1? n                  Trunk Flash? n         Toll Restricted? n
     TRUNK PARAMETERS
    Trunk Type: loop-start
    Outgoing Dial Type: tone                              Cut-Through? n
          Trunk Termination: rc                    Disconnect Timing(msec): 500
                 Auto Guard? n    Call Still Held? n     Sig Bit Inversion: none
          Terminal Balanced? n                               RA Trunk Loss: 0db
                                       Trunk Gain: low
      Disconnect Supervision - In? y  Out? n
    Answer Supervision Timeout: 10             Receive Answer Supervision? n 
    change trunk-group 1                                          Page   2 of  10
     TRUNK FEATURES
               ACA Assignment? n            Measured: none
                                                               Maintenance Tests? y
                                    Data Restriction? n
       Abandoned Call Search? n 
       Suppress # Outpulsing? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    411 South Africa 
    nAnalog ue E&M Trunk (setup  as wink/wink for Transtel)
    — Make/Break Ratio: 35/65
    change trunk-group 1                                         Page   3 of  10
                                     TRUNK GROUP
      ADMINISTRABLE TIMERS
     Incoming Disconnect(msec): 500             Outgoing Disconnect(msec): 500
                                                   Outgoing Dial Guard(msec): 1600
       Incoming Glare Guard(msec): 1500           Outgoing Glare Guard(msec): 1500
            Ringing Monitor(msec): 5200               Incoming Seizure(msec): 500
        Outgoing End of Dial(sec): 10         Outgoing Seizure Response(sec): 5
      Programmed Dial Pause(msec): 1500
               Flash Length(msec): 540
     END TO END SIGNALING
         Tone(msec): 350      Pause(msec): 150
     OUTPULSING INFORMATION
          PPS: 10    Make(msec): 35   Break(msec): 65      PPM? n
     change trunk-group 2                                          Page   1 of  10
                                     TRUNK GROUP
     Group Number: 2                   Group Type: tie           CDR Reports: y
       Group Name: e&m                        COR: 1                     TAC: 31
        Direction: two-way       Outgoing Display? n    Trunk Signaling Type:
      Dial Access? y               Busy Threshold: 99          Night Service:
     Queue Length: 0                                    Incoming Destination:
        Comm Type: voice                Auth Code? n   
     TRUNK PARAMETERS (tone or rotary)
    Trunk Type (in/out): immed/immed     Incoming Rotary Timeout (sec): 10
    Outgoing Dial Type: rotary                     Incoming Dial Type: rotary
                                                   Disconnect Timing(msec): 500
            Digit Treatment:                                        Digits:
                                                         Sig Bit Inversion: none
          Connected to Toll? n      STT Loss: normal       DTT to DCO Loss: normal
         Incoming Dial Tone? y
      Disconnect Supervision - In? y  Out? n
    Answer Supervision Timeout: 10             Receive Answer Supervision? n  
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    412 South Africa 
    nMFC-R2 DID
    — Country: 8
    — Trunk Gain: low
    change trunk-group 2                                          Page   2 of  10
     TRUNK FEATURES
               ACA Assignment? n            Measured: none
                                      Internal Alert? n      Maintenance Tests? n
                                    Data Restriction? n
       Abandoned Call Search? n 
       Suppress # Outpulsing? n
                Used for DCS? n
       Suppress # Outpulsing? n
                        Seize When Maintenance Busy: neither-end
     change trunk-group 2                                         Page   3 of  10
                                     TRUNK GROUP
      ADMINISTRABLE TIMERS
     Incoming Disconnect(msec): 500             Outgoing Disconnect(msec): 500
       Incoming Dial Guard (msec): 70              Outgoing Dial Guard(msec): 1600
      Incoming Glare Guard (msec): 1500           Outgoing Glare Guard(msec): 1500
      Incoming Partial Dial (sec): 18
                                      Outgoing Rotary Dial Interdigit (msec): 800
                           
        Outgoing End of Dial(sec): 10         Outgoing Seizure Response(sec): 5
      Programmed Dial Pause(msec): 1500        Disconnect Signal Error (sec): 240
                                        Incoming Incomplete Dial Alarm (sec): 255
      END TO END SIGNALING
         Tone(msec): 350      Pause(msec): 150
      OUTPULSING INFORMATION
          PPS: 10    Make(msec): 35   Break(msec): 65       
    						
    All Lucent Technologies manuals Comments (0)