Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual
Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 183 France Time of Day Routing nOBJECT: time-of-d ay-routing — En g li s h : EN TER A C TI VATI O N RO U TE PL A N , D AY & TI M E Translation: SAISIR H/DATE ACTIVATION AGENDA ROUTAGE — En g li s h : EN TER D EA C TI VATI O N D AY A N D TI M E Translation: SAISIR H/DATE DESACTIVATION AGENDA — Eng lish: OLD ROUTE PLAN: ENTER NEW PLAN: Translation: ANCIEN AGENDA: SAISIR NOUVEAU: — Eng lish: OLD ROUTE PLAN: NEW PLAN: Translation: ACIEN AGENDA: NOUVEAU: — En g li s h : ROU TE PL A N : FO R A C T- TI M E: Translation: AGENDA: HeureDeb ut: — En g li s h : ROU TE PL A N : FO R D EA C T- TI M E: Translation: AGENDA: POUR Heure Fin: Softkey Labels The following translations are c onsistent with the 8400 and 9400 DCP Terminals - Foreig n Lang uag e Translation Req uirements). nOBJECT: softkey-lab els —English: AD Translation: NoAb r — Eng lish: AutCB Translation: Rap pl —English: CFrwd Translation: RTemp — Eng lish: CnLWC Translation: AnMsg — Eng lish: Cnslt Translation: Notif — Eng lish: Count Translation: Comp t — Eng lish: CPark Translation: Parc
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 184 France — Eng lish: CPkUp Translation: Intc p —English: Dir Translation: Rp ert —English: Excl Translation: Protc —English: HFAns Translation: inter — Eng lish: IAuto Translation: IAuto — Eng lish: IDial Translation: IAbr — Eng lish: Insp t Translation: Info — Eng lish: Last Translation: Bis —English: LWC Translation: Msg —English: Mark Translation: ModMF — English: Pause Translation: Pause — Eng lish: PCall Translation: Prior —English: Prog Translation: Prog — Eng lish: Rng Of Translation: SOff —English: SAC Translation: RFixe —English:SFunc Translation: FSp ec
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 185 France —English: Spres Translation: Sup p r — Eng lish: Stats Translation: Stats — Eng lish: Stop Translation: Stop —English: Timer Translation: Chron — Eng lish: TmDay Translation: H/Dat — Eng lish: View Translation: AffNo —English: Wait Translation: AttTo Vu S t a t s nOBJECT: vustats —English: FORMAT Translation: FORMAT — Eng lish: NOT DEFINED Translation: NON DEFINI — En g li s h : D O ES N O T A L L OW OR REQU I RE I D Translation: NO IDENTIFICATION REQUIS —English: AGENT Translation: AGENT — Eng lish: SPLIT/SKILL Translation: GROUPE ACD — Eng lish: TRUNK GROUP Translation: GR. LIGNES —English: VDN Translation: VDN — En g li s h : N O T AD M I N I STERED Translation: NON ADMINISTRE
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 186 France — Eng lish: NOT MEASURED Translation: NON MESURE — En g l i s h : A GEN T N O T L OG G ED I N Tr a n sl a t i o n : AG EN T N ’AYA N T PA S ETA B L I L A
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 187 Germany Germany Ta b l e 2 9 shows the rec ommended c irc uit p ac ks. Table 29. Recommended and Available CPs in Germany Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 220V/50Hz Ring Generator 25Hz Tone Detec tor > TN2182B > TN744D TN420C Tone Cloc k > TN2182B TN780 R2MFC Circ uit n/a Sp eec h Synthesizer n/a Call Classifier > TN744D Announc ement #TN750C > TN750B Analog DID Trunk > TN2184 (See the note that follows this tab le.) Analog CO Trunk (No PPM) > TN2147C Analog CO Trunk (w/PPM) > TN2184 4 Wire Tie Trunk n/a 2 Wire Tie Trunk n/a Auxiliary Trunk > TN763D Dig ital CO/DID Trunk n/a Dig ital Tie Trunk > TN464F TN464E Dig ital PRI CO Trunk > TN464F Dig ital BRI Trunk > TN2185 Dig ital Converter PRI-DASS Dig ital Converter PRI-DPNSS Dig ital Converter PRI-BRI #TN-PRI-BRI 8 Port Analog Line n/a 16 Port Analog Line #TN2183 > TN2180 Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 188 Germany NOTE: TN2184 p rovides DIOD op eration and PPM at 12Hz or 16Hz, b ut not at 50Hz. Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nARS/AAR Ad ministration To enab le ARS administration, on the System-Parameters Customer-Op tions sc reen, set the ARS field to y . You also should check all ARS/AAR d efaults. All d efault ARS analysis c odes are deleted b efore d ialed strings are ad d ed for routing when DEFINITY is installed outsid e of North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing p rob lems. In p artic ular, the following c all typ es (ap pear as ARS/AAR d efaults) typ ic ally are not used in non-North Americ an ARS/AAR tab les: 24 Port Analog Line n/a 4 Wire Digital Line > TN754B 2 Wire Digital Line #TN2224 > TN2181 Data Line > TN726B BRI-U Line BRI-ST Line TN556B fnp a: North Americ an numb ers with an area c od e. hnp a: North Americ an numb ers without an area c od e. svc : North Americ an numb ers of the sc reen ‘‘x11’’. Ta b l e 2 9 .Recommended and Available CPs in Germany — Continued Equipment Equipment Type Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 189 Germany Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: System Parameter Administration Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nFeature-Related System Parameters Ad ministration — Trunk-to-Trunk Transfer: Restric ted (of Pub lic trunks not p ermitted in Germany) — Coverag e - Sub sequent Redirec tion No Answer Interval: 1 — Coverag e - Caller Resp onse Interval (sec ond s): 1 — Keep Held SBA at Coverag e Point? y — Automatic Callb ac k - No Answer Timeout Interval (ring s): 2 — Call Park Timeout Interval (minutes): 3 — Off-Premises Tone Detec t Timeout Interval (sec ond s): 15 — AA R/ ARS Dia l To ne Req u ire d : y — DID/TIE/ISDN Interc ep t Treatment: Attend ant — Time b efore Off-hook Alert: 10 — Servic e Ob serving Warning Tone: Yes — Pub lic Network Trunks on Conferenc e Call: 1 — Conferenc e Parties With PNTs: 3 — Conferenc e Parties Without PNTs: 6 — Nig ht Servic e Disc onnec t Timer: 180 sec — Short Interd ig it Timer: 3 sec — Unanswered DID Call Timer: 25 sec — Line Interc ep t Tone Timer (sec onds): 30 —Auto-Hold: Yes1 — Attend ant Tone: Yes — Bridg ing Tone: No int: For all international numb ers. natl: For all national PN numbers. p ub u: For all other external (that is, not extensions) numbers.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 190 Germany — Conferenc e Tone: Yes — Intrusion Tone: Yes — DID Busy Treatment: Attend ant — Pull Transfer: No — Level of Tone Detec tion: Med ium — Wait Answer Sup ervision Timer: No — Rep etitive Call Waiting Tone: Yes — Outp ulse Without Tone: No — Network Feed b ac k During Tone Detec tion: No — Interc ept Treatment On Failed Trunk Transfers: No — (Station-to-switc h) Rec all Timing : nFlashhook Interval: No nDisc onnec t Timing : 250 ms nSystem Parameter Country Op tions Ad ministration — Comp and ing Mode: A-law — Base Tone Generation Set: 13 — Tone Detec tion Mod e: 4 — Interd ig it Pause: long — Dial Tone Valid ation Timer: 600ms — Analog Ring ing Cad enc e: 13 — Customized Individual Tones — Customized tone d efinitions follow the syntax as sp ec ified : [ (Freq uenc y/Level)|silenc e|g oto)] [ (Duration ms)|(Step)] nBusy — (425/-4)(500) — (silence)(500) (475 is desired, but not possible) — (go to)(1) nRe o rd e r — (425/-4)(250) — (silence)(250) — (go to)(1) nRingback — (425/-4)(1000)
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 191 Germany — (silenc e)(4000) — (go to)(1) Analog Trunk Administration nCO Trunks — Trunk Group Sc reen nGroup Typ e: CO nCOR: COR for CO trunks must have a hig her FRL than all inc oming Tie trunk g roup s. (This is req uired sinc e German reg ulations p rohib it c onnec ting two trunks even throug h a p rivate network.) nDirec tion: two-way nDial Ac c ess: Customer Op tion, No is rec ommend ed to avoid toll fraud nCountry Code: 13 nDig it Ab sorp tion List: b lank nPre f i x -1 : N o nTrunk Type: loop -start nOutg oing Dial Typ e: tone nTrunk Termination: rc (c omp lex imp ed anc e) nParameters b ased on loop leng th (whic h itself is not ad ministrable) nAuto Guard : no nSig Bit Inversion: none nCall Still Held : no nRec eive Answer Sup ervision: no nAnswer Supervision Timeout: 10 (This sets both the CP firmware timer and software timer. Set to 0 for any trunk rec eiving answer supervision.) nDisc onnec t Sup ervision - In: — Analog Trunks: yes — Dig ital Trunks: yes Loop Length Trunk Gain Terminal Balance RA Trunk Loss short low n 0dB long high n 2dB
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 192 Germany nDisc onnec t Sup ervision - Out: no nDisc onnec t Timing : 500 msec (This field will not b e used with CPs that c an ac c ep t the Inc oming Disc onnec t and Outg oing Disc onnec t timers. Set these latter two timers from the Ad ministrab le Timers Sc reen.) nSup p ress # Outpulsing : yes — Trunk Group Ad ministration Sc reen (Timing ) Set the following timers from the Administrab le Timers sc reen d uring ad ministration of eac h trunk g roup . Selec t the following CO trunk timer values for this c ountry: nInc oming Disc onnec t: 1100 ms nOutg oing Disc onnec t: 1100 ms nOutg oing Dial Guard : 4000 ms nInc oming Glare Guard : 1500 ms nOutg oing Glare Guard : 1500 ms nOutg oing Rotary Dial Interd igit: 800 ms nRing Monitor Timer: 5200 ms nInc oming Seizure: 500 ms nOutg oing End -of-Dial: 10 sec nOutg oing Seizure Resp onse: — Analog trunks: 5 sec — Dig ital trunks: 2 sec nProg rammed Dial Pause: 1500 ms nFlash Leng th: 540 ms nEnd -To-End Sig naling Pause: 150 ms nEnd -To-End Sig naling Tone: 350 ms nPPS: 1 0 nMake: 40 ms nBreak: 60 ms nPPM : n nDIOD Trunks — Trunk Group Sc reen nGroup Typ e: DIOD nDirec tion: two-way nCountry Code: 13