Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual

Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 484
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    383 Slovak Republic 
    Slovak Republic
    Ta b l e  5 2 shows the rec ommended  c irc uit p ac ks.
    Table 52. Recommended and Available CPs in Slovak Republic 
    Equipment Equipment Type
    Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC DC-SCC 
    AC-CSCC AC-CMC
    AC Power Voltag e & Freq 220V/50Hz 
    Ring  Generator 25Hz
    Tone Detec tor > TN2182B > TN744D TN420C 
    Tone Cloc k > TN2182B TN780
    R2MFC Circ uit
    Sp eec h Synthesizer > TN457 
    Call Classifier > TN744D
    Announc ement TN750C TN750B 
    Analog  DID Trunk > TN753v17
    Analog  CO Trunk (No PPM)  > TN747Bv12
    Analog  CO Trunk (w/PPM) #TN465C> TN465B
    4 Wire Tie Trunk > TN760Dv11
    2 Wire Tie Trunk
    Auxiliary Trunk > TN763D 
    Dig ital CO/DID Trunk > TN464F TN464E 
    Dig ital Tie Trunk > TN464F TN464E 
    Dig ital PRI CO Trunk n/a 
    Dig ital BRI Trunk > TN2185
    Dig ital Converter PRI-DASS   
    Dig ital Converter PRI-DPNSS
    Dig ital Converter PRI-BRI   
    8 Port Analog  Line n/a
    16 Port Analog  Line > TN746B
    24 Port Analog  Line n/a
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    384 Slovak Republic 
    Feature Administration
    The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e 
    ap p roval was award ed . The sc reens may have c hang ed  sinc e that d ate.
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nARS/AAR Ad ministration
    To enab le ARS administration, on the System-Parameters 
    Customer-Op tions sc reen, set the ARS
     field  to y
    . You also should check all 
    ARS/AAR d efaults. All d efault ARS analysis c odes are deleted  b efore 
    d ialed  strings are ad d ed for routing when DEFINITY is installed  outsid e of 
    North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing 
    p rob lems. In p artic ular, the following  c all typ es (ap pear as ARS/AAR 
    d efaults) typ ic ally are not used  in non-North Americ an ARS/AAR tab les:
    Luc ent rec ommend s only the following  c all typ es b e used  outside North 
    Americ a: 4 Wire Digital Line > TN754B 
    2 Wire Digital Line #TN2224 > TN2181 TN2136
    Data Line > TN726B 
    BRI-U Line
    BRI-ST Line  
    fnp a: North Americ an numb ers with an area c od e.
    hnp a: North Americ an numb ers without an area c od e.
    svc : North Americ an numb ers of the screen ‘‘x11’’.
    int: For all international numbers.
    natl: For all national PN numb ers.
    pubu: For all other external (that is, not extensions) numbers. Table 52. Recommended and Available CPs in Slovak Republic  — 
    Continued
    Equipment Equipment Type
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    385 Slovak Republic 
    System Parameter Administration
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nFeature-Related System Parameters Ad ministration
    — Off-Premises Tone Detec t Timeout Interval (sec ond s): 5
    — Nig ht Servic e Disc onnec t Timer (sec ond s): 10 (10 or b lank for 
    testing  op tional responses to errors
    — Unanswered  DID Call Timer (sec ond s): 180
    — DID Busy Treatment (set to attendant for testing  op tional resp onse 
    to errors)
    display system-parameters features                              Page   1 of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
                                     Trunk-to-Trunk Transfer: all
     Coverage Subsequent Redirection/CFWD No Answer Interval: 2
               Coverage - Caller Response Interval (seconds): 4
                             Keep Held SBA at Coverage Point? y
     Automatic Callback - No Answer Timeout Interval (rings): 3
                        Call Park Timeout Interval (minutes): 10
    Off-Premises Tone Detect Timeout Interval (seconds): 5
                                  AAR/ARS Dial Tone Required? y
                                          Music/Tone on Hold: none
               Music (or Silence) on Transferred Trunk Calls? no
                            DID/Tie/ISDN Intercept Treatment: attd
                   Messaging Service Adjunct (MSA) Connected? n
      Internal Automatic Answer for Attendant Extended Calls? n
                   Automatic Circuit Assurance (ACA) Enabled? n
              Abbreviated Dial Programming by Assigned Lists? n
        Auto Abbreviated/Delayed Transition Interval (rings): 2 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    386 Slovak Republic 
    — Outp ulse Without Tone? n (for d ial tone d etec tion)
    — Network Feed b ac k During  Tone Detec tion? n (for dial tone 
    detection)
    nSystem Parameters Customer Op tions
    — ARS? y (for d ial tone d etec tion)
    display system-parameters features                              Page   5 of   6
                             FEATURE-RELATED SYSTEM PARAMETERS
                        Public Network Trunks on Conference Call: 5
                   Conference Parties with Public Network Trunks: 6
                Conference Parties without Public Network Trunks: 6
                        Night Service Disconnect Timer (seconds): 10
                                Short Interdigit Timer (seconds): 3
    Unanswered DID Call Timer (seconds): 180
                             Line Intercept Tone Timer (seconds): 20
                                                      Auto Start? n
                                                       Auto Hold? y
                                                  Attendant Tone? y
                                                   Bridging Tone? n
                                                 Conference Tone? n
                                                  Intrusion Tone? y
    DID Busy Treatment: tone
                              Allow AAR/ARS Access from DID/DIOD? n
       DISTINCTIVE AUDIBLE ALERTING
                            Internal: 1   External: 2   Priority: 3
    display system-parameters features
                             FEATURE-RELATED SYSTEM PARAMETERS
                                                          Pull Transfer: n
                                                Level Of Tone Detection: precise
                                          Wait Answer Supervision Timer? n
                                           Repetitive Call Waiting Tone? n
    Outpulse Without Tone? n
    Network Feedback During Tone Detection? n
                          Intercept Treatment On Failed Trunk Transfers? n
                                          Vector Disconnect Timer (min):
                                        Station Tone Forward Disconnect: intercept
                                                  Misoperation Alerting? n
                                             Allow Conference via Flash? y
     RECALL TIMING
             Flashhook Interval? y                   Upper Bound (msec): 1000
                                                     Lower Bound (msec): 200
                                        Forward Disconnect Timer (msec): 600
     ENHANCED DCS
           Enhanced DCS Enabled? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    387 Slovak Republic 
    — Malic ious Call Trac e? y (for Malic ious Call feature)
    — Multifreq uenc y Sig naling ? y 
    nSystem Parameter Country Op tions Ad ministration
    — Comp and ing  Mode: A-Law
    — Dig ital Loss Plan: 14
    — Analog  Ring ing  Cad enc e: 14
    — Analog  Line Transmission: 14
    display system-parameters customer-options                      Page   1 of   2
                                     OPTIONAL FEATURES
                       G3 Version: V4
             Logged-In ACD Agents: 150
         Abbreviated Dialing Enhanced List? n                  Call Work Codes? n
      A/D Grp/Sys List Dialing Start at 01? n                       CAS Branch? n
                                       ACD? n                         CAS Main? n
                        AT&T Adjunct Links? n                      DCS (Basic)? n
     Answer Supervision by Call Classifier? n                DCS Call Coverage? n
    ARS? y    DTMF Feedback Signals For VRU? n
                      ARS/AAR Partitioning? y    Emergency Access to Attendant? y
                            ASAI Interface? n     Expert Agent Selection (EAS)? n
                                      ATMS? n      External Device Alarm Admin? n
                   Audible Message Waiting? n                 Flexible Billing? n
                       Authorization Codes? n    Forced Entry of Account Codes? n
                              BCMS (Basic)? n              Hospitality (Basic)? y
                     BCMS/VuStats LoginIDs? n    G3V3 Hospitality Enhancements? n
                BCMS/VuStats Service Level? n  Hospitality Parameter Reduction? n
    display system-parameters customer-options
                                     OPTIONAL FEATURES
                                ISDN-PRI? n            Service Observing (VDNs)? n
                    ISDN-PRI over PACCON? n               Station and Trunk MSP? n
               Lookahead Interflow (LAI)? n                 Tenant Partitioning? n
                    Malicious Call Trace? y         Terminal Trans. Init. (TTI)? n
    Multifrequency Signaling? y                 Time of Day Routing? n
     Multiple Call Handling (On Request)? n                Uniform Dialing Plan? n
         Multiple Call Handling (Forced)? n                   Vectoring (Basic)? n
       PASTE (Display PBX Data on Phone)? n               Vectoring (Prompting)? n
                                                      Vectoring (G3V4 Enhanced)? n
                Premier Business Package? y   Vectoring (ANI/II-Digits Routing)? n
                Processor and System MSP? n   Vectoring (G3V4 Advanced Routing)? n
                      Private Networking? n          VDN of Origin Announcement? n
                                                         VDN Return Destination? n
           Restrict Call Forward Off Net? y      Voice Mail Application Support? n
                   Secondary Data Module? n                             VuStats? n
               Service Observing (Basic)? y             VuStats (G3V4 Enhanced)? n
       Service Observing (Remote/By FAC)? n                  Wideband Switching? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    388 Slovak Republic 
    — Tone Detec tion Mod e: 5
    — Customized Individual Tones
    In this sec tion, c ustomized tone d efinitions follow the data-entry 
    syntax as sp ec ified  for entry on the Ind ivid ual Tone Ad ministration 
    Sc reen:
    [ (Freq uenc y/Level)|silenc e|g oto)] [ (Duration ms)|(Step)]
    — Intrusion:
    n(425/-11.0)(350)
    n(silenc e)(350)
    n(425/-5.0)(350)
    n(silenc e)(1500)
    n(goto)(1)
    — Reord er (Cong estion):
    n(425/-5)(150)
    n(silenc e)(150)
    n(goto)(1)
    — Sec ond ary Dial Tone:
    n(425/-5)(150)
    n(silenc e)(150)
    n(425/-5)(150)
    n(silenc e)(150)
    n(425/-5)(150)
    n(silenc e)(150)
    n(425/-5)(650)
    display system-parameters country-options                       Page   1 of  21
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
    Companding Mode: A-Law             Base Tone Generator Set: 14
              440Hz PBX-dial Tone? n               440Hz Secondary-dial Tone? n
    Digital Loss Plan: 14
    Analog Ringing Cadence: 14     Set Layer 1 timer T1 to 30 seconds? n
    Analog Line Transmission: 14
     TONE DETECTION PARAMETERS
    Tone Detection Mode: 5        Dial Tone Validation Timer(msec): 500
                 Interdigit Pause: long 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    389 Slovak Republic 
    n(silenc e)(650)
    n(goto)(1)
    —PBX Dial Tone:
    n(425/-5)(500)
    n(goto)(1)
    —Busy:
    n(425/-5)(350)
    n(silenc e)(350)
    n(goto)(1)
    — Ringback:
    n(425/-5)(1000)
    n(silenc e)(4000)
    n(goto)(1)
    — Call Wait 1:
    n(425/-11)(350)
    — Rec all Dial:
    n(425/-4)(150)
    n(silenc e)(150)
    n(425/-4)(150)
    n(silenc e)(150)
    n(425/-4)(1000)
    n(goto)(5)
    nC D R Sys t e m  Pa r a m e t e r s
    — Primary Outp ut Format: int-d irec t (for showing  PPM) 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    390 Slovak Republic 
    nSystem Parameter Multifreq uenc y Sig naling  Ad ministration (Pay c lose 
    attention to the values on the following  three sc reens. They are c ritic al.)
    — Req uest Inc oming  ANI (non-AAR/ARS)? n (To c hec k Inc oming  ANI, 
    enter yes. It is p art of the malic ious c all trac e op tion.)
    NOTE:
    On Pag e 2 of the Multifreq uenc y-Sig naling -Related  System Parameters sc reen, 
    Group -I, numb ers 12, 13, and  14, should  all b e 
    ani-not-avail.
    display system-parameters cdr
                                 CDR SYSTEM PARAMETERS
      Node Number (Local PBX ID): 1                     CDR Date Format: month/day
    Primary Output Format: int-direct         Primary Output Ext: eia
         Secondary Output Format:
                Use ISDN Layouts? n                 EIA Device Bit Rate: 9600
            Use Enhanced Formats? n
                       Record Outgoing Calls Only? n            Intra-switch CDR? n
       Suppress CDR for Ineffective Call Attempts? y          CDR Call Splitting? y
           Disconnect Information in Place of FRL? n    Attendant Call Recording? y
                                                          Interworking Feat-flag? n
      Force Entry of Acct Code for Calls Marked on Toll Analysis Form? n
                                         Calls to Hunt Group - Record: member-ext
     Record Called Vector Directory Number Instead of Group or Member? n
       Record Non-Call-Assoc TSC? n
           Record Call-Assoc TSC? n   Digits to Record for Outgoing Calls: dialed
        Privacy - Digits to Hide: 0               CDR Account Code Length: 2
    display system-parameters multifrequency-signaling              Page   1 of   3
                  MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
                                               Incoming Call Type: group-ii-mfc
                                               Outgoing Call Type: group-ii-mfc
                                            Maintenance Call Type: none
                                              Test Call Extension:
                                           Interdigit Timer (sec): 20
                      Outgoing Forward Signal Present Timer (sec): 20
                       Outgoing Forward Signal Absent Timer (sec): 12
            Multifrequency Signaling Incoming Intercept Treatment? y
                                 Received Signal Gain(-Loss) (dB): 0
                              Transmitted Signal Gain(-Loss) (dB): -3
          ANI Prefix: 42        Collect All Digits Before Seizure? n
         ANI for PBX: 400
      Next ANI Digit: send-ani
    Request Incoming ANI (non-AAR/ARS)? n
                                            Called Party Category: user-type
                               Use COR for Calling Party Category? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    391 Slovak Republic 
    nARS Digit Analysis 
    — Rte Pat: 2 (for d ial tone d etec t)
    display system-parameters multifrequency-signaling              Page   2 of   3
                  MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
     INCOMING FORWARD SIGNAL TYPES           INCOMING BACKWARD SIGNAL TYPES
     (Tones from CO)                         (Tones to CO)
           Group-I             Group-II            Group-A             Group-B
      11: send-congest     1: normal          1 : next-digit      3 : busy
      12: send-congest     2: busy-rt-attd    3 : end-of-dial     4 : congestion
      13: ani-not-avail    3: busy-rt-attd    4 : congestion      5 : intercept
      14: send-congest     4: normal          5 : send-ani        6 : free
      15: end-of-dial      5: busy-rt-attd      :                   :
                           6: normal            :                   :
    7: normal            :                   :
    8: normal            :                   :
    9: busy-rt-attd      :                   :
    10: normal            :                   :
    11: send-intercept    :                   :
                          12: send-intercept    :                   :
                          13: normal            :                   :
                          14: normal            :                   :
                          15: send-intercept    :                   : 
    display system-parameters multifrequency-signaling
                  MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
     OUTGOING FORWARD SIGNAL TYPES           OUTGOING BACKWARD SIGNAL TYPES
     (Tones to CO)                           (Tones from CO)
           Group-I             Group-II            Group-A             Group-B
      12: ani-not-avail   1 : normal           1: next-digit       1: free
      15: end-of-digits   1 : attendant        2: last-digit       2: congestion
        :                 6 : data-call        3: end-of-dial      3: busy
        :                   :                  4: congestion       4: congestion
        :                   :                  5: send-ani         5: intercept
                            :                  6: setup-sppath     6: free
                            :                  7: last-2-digits    7: free
                            :                  8: last-3-digits    8: intercept
                            :                  9: congestion       9: congestion
                            :                 10: congestion      10: congestion
                            :                 11: congestion      11: congestion
                            :                 12: congestion      12: congestion
                            :                 13: congestion      13: congestion
                            :                 14: congestion      14: congestion
                            :                 15: congestion      15: congestion  
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    392 Slovak Republic 
    nRoute Pattern
    — Inserted  Digits: +  (for d ial tone d etec t)
    nConsole Parameters
    display ars analysis 0
                                  ARS DIGIT ANALYSIS TABLE
                                Partitioned Group Number:  1     Percent Full:    2
            Dialed      Total Rte Call Nd ANI       Dialed      Total Rte Call Nd ANI
            String      Mn Mx Pat Type Num Rq       String      Mn Mx Pat Type Num Rq
     2                  2  7  2   pubu     n                                       n
     3                  2  7  2   pubu     n                                       n
     4                  2  7  2   pubu     n                                       n
     5                  2  7  2   pubu     n                                       n
     6                  7  7  2   hnpa     n                                       n
     7                  2  7  2   pubu     n                                       n
     8                  2  7  2   pubu     n                                       n
     9                  2  7  2   pubu     n                                       n
                                           n                                       n
                                           n                                       n
                                           n                                       n
                                           n                                       n
                                           n                                       n
                                           n                                       n
    display route-pattern 2
                                 Pattern Number: 2
        Grp.  FRL NPA Pfx Hop Toll No. Del Inserted
        No.           Mrk Lmt List Digits  Digits
      1: 29    0                           +
      2:
      3:
      4:
      5:
      6: 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Application Notes For Type Approval Manual