Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-67 Add IP Interface Assembly 6 5. When done, click OK, OK. Upgrade to TN802B (R8) NOTE: The upgrade takes about 20 minutes. 1. Insert the flash disk into the right most slot on the TN802 IP trunk. On the monitor, a dialog box assigns a drive letter with the removable media designation; the default is D:. 2. Right click on Start > Explore to open the Windows NT Exploring pane and select the drive letter indicated in step 1. 3. Double-click on Medpro and select the Setup icon.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-68 Add IP Interface Assembly 6 4. Follow the Install Shield procedure to transfer all the necessary files to the TN802 IP Interface. NOTE: In the Finish dialog box, select I will restart later. Do not select Restart computer. This would be a good time to read the Readme.txt file. 5. Click on Start > Settings > Control Panel > Services. 6. Select IP Trunk and click on Startup. NOTE: Do not click on Start. 7. Under Startup Type, select Disabled and click OK to disable IP Trunk mode. NOTE: If IP trunk and MedPro services are both set to automatic, the TN802B defaults to IP Trunk and MedPro features cannot be used. 8. Select MedPro and click on Startup. NOTE: Do not click on Start. 9. Under Startup Type, select Automatic and click OK to enable MedPro mode. 10. Click Start > Shut Down and select Restart the computer? or on the TN802: Press the recessed reset button on the faceplate (see Figure 6-21 ) until the LCD shows a flashing MSHUT *. When the flashing stops and the asterisk disappears (about 2 min), reseat the circuit pack to restart the system. or on the SAT: a. Type busyout board UUCSS and press En t e r . b. Type reset board UUCSS and press En t e r. c. Type release board UUCSS and press En t e r.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-69 Add IP Interface Assembly 6 Once the system is completely initialized, the LCD reads MEDPRO *. !WARNING: When connected remotely via pcANYWHERE, only use the pcANYWHERE Restart Host Computer button on the toolbar to restart Windows NT. 11. Affix the new TN802B label to the circuit pack. 12. Disconnect the monitor, keyboard, and mouse. Circuit Pack Verification 1. Type change circuit-pack and press En t e r. 2. Check the Code column to see if it says DSMAPD or MedPro. . 3. To correct it, go to the entry just above the TN802B that says DSMAPD. 4. Type MEDPRO, and press En te r. Changing the one entry automatically changes the entry above it. If it is in IP Trunk mode, you get the following error message: MedPro type requires TN802 with application. Type MEDPRO on circuit-packs form. 5. To complete the administration, refer to the DEFINITY ECS Release 8 Network Connectivity book. change circuit-packs Page 1 of 5 CIRCUIT PACKS Cabinet: 1 Carrier: A Carrier Type: processor Slot Code Sf Mode Name Slot Code Sf Mode Name 11: MEDPRO RESERVED-IP 01: TN754 DIGITAL LINE 12: MEDPRO RESERVED-IP 02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD 03: TN2144 ANALOG LINE 14: 04: TN746 B ANALOG LINE 15: 05 16: 06: TN771 C MAINTENANCE/TEST 07: TN464 F DS1 INTERFACE 08: TN2140 E&M TIE TRUNK 09: TN767 E DS1 INTERFACE 10: TN799 B CONTROL-LAN # indicates circuit pack conflict.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-70 Add TTC Japanese 2-Mbit Trunks 6 Add TTC Japanese 2-Mbit Trunks The TN2242 Japan 2-Mbit trunk interconnects DEFINITY to other vendor equipment in Japan as well as to other DEFINITY switches through the Time Division Multiplexor (TDM). Installing the trunks Determine the port assignment of the trunk from the Trunk Group form. 1. Install a TN2242 circuit pack in assigned carrier slot. 2. Connect the H600-513 cable from the DEFINITY cabinet to the Time Division Multiplexor device. 3. To administer forms, see the following sections in the DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . nFor ISDN applications, see ISDN Service. nFor non-ISDN applications, see Managing Trunks. Adding SCC Port Cabinets Up to 3 port cabinets may be stacked on a Release 8si PPN’s basic control cabinet or EPN’s expansion control cabinet. !CAUTION: A port cabinet may weigh as much as 125 pounds. Use lifting precautions to avoid injury. Unpack and Inspect for Damage 1. Unpack the cabinets. 2. Inspect the cabinets for any damage caused during shipping. Repor t any damage per local procedures. Service Interruption 1. Since the addition of port cabinets requires a service interruption, notify the customer in advance when the addition will take place. EXAMPLE:3A0701 Cabinet (Port Network)Carrier Slot NumberPort Number
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-71 Adding SCC Port Cabinets 6 Disable Alarm Origination 1. Type change system-parameters maintenance and press En te r. 2. Set the Alarm Origination field to n. !CAUTION: If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets. 3. For some releases of software, disable Cleared Alarm Notification and Restart Notification before submitting the form. Save Translations and Announcements 1. If the system is high or critical reliability, type status system 1 and press En t e r to verify that the system is in the “active” mode. 2. Type save translation and press En te r. This instructs the system to take all translation information in memory and write it to the translation cards. 3. If the SCC port network contains a TN750/B/C Announcement circuit pack, type display announcements and press En t e r. 4. If administered recorded announcements are listed, type list configuration software-version and press En t e r. To save the announcements, type save announcements and press En te r. Shut Down DEFINITY AUDIX System !WA R N I N G : Neglecting to shut down an AUDIX assembly before powering down the system cabinet where it resides can damage the AUDIX disk. 1. Shut down the AUDIX assembly and allow the disk to completely spin down. Power Down SCC Cabinet Stack 1. At the cabinet stack being upgraded, set the circuit breaker to OFF. 2. Unplug the power cord from the receptacle of each cabinet. Position Port Cabinets 1. Stack the port cabinets on top of the control cabinet (A) or expansion control cabinet (B, if present). See Figure 6-23 .
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-72 Adding SCC Port Cabinets 6 2. Install cabinet labels on the front and rear of cabinets to the left of the circuit pack labels. Label the second cabinet “B”, the third cabinet “C”, and the four th cabinet “D”. Figure 6-23. PPN Cabinet — Front View Connect TDM or TDM/LAN Cables 1. Disconnect the TDM or TDM/LAN bus terminator from Slot 22 of the control cabinet, or from Slot “18” of an expansion control cabinet, or from Slot “17” of a por t cabinet. Figure Notes 1. Control Cabinet or Expansion Control Cabinet (“A” Position) 2. Port Cabinet (“B” Position)3. Port Cabinet (“C” Position) 4. Port Cabinet (“D” Position)
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-73 Adding SCC Port Cabinets 6 2.Move the terminator to slot “17” of the top port cabinet. See Figure 6-24, Figure 6-25 , or Figure 6-26. 3. Connect the TDM/LAN cables behind the lower rear cover. Figure 6-24. TDM/LAN Connections for Standard or High Reliability PPN or EPN Figure Notes 1. AHF110 TDM/LAN Bus Terminator 2. Slot 17 3. TDM/LAN Cable (WP91716 L3) 4. Slot 00 5. Slot 226. Slot 02 7. Port Cabinet (“D” Position) 8. Port Cabinet (“C” Position) 9. Port Cabinet (“B” Position) 10. Control Cabinet (“A” Position)
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-74 Adding SCC Port Cabinets 6 Figure 6-25. TDM/LAN Connections High or Critical Reliability PPN Figure Notes 1. AHF110 TDM/LAN Bus Terminator 2. Slot 17 3. TDM/LAN Cable (WP91716 L3) 4. Slot 00 5. Slot 226. Slot 02 7.Port Cabinet (“D” Position) 8. Port Cabinet (“C” Position) 9. Duplicated Control Cabinet (“B” Position) 10. Control Cabinet (“A” Position)
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-75 Adding SCC Port Cabinets 6 Figure 6-26. TDM/LAN Connections for Critical Reliability EPN Figure Notes 1. AHF110 TDM/LAN Bus Terminator 2. Slot 17 3. TDM/LAN Cable (WP91716 L3) 4. Slot 00 5. Slot 186. Slot 01 (TDM/LAN Bus Terminator) 7.Port Cabinet (“D” Position) 8. Port Cabinet (“C” Position) 9. Port Cabinet (“B” Position) 10. Expansion Control Cabinet (“A” Position)
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-76 Adding SCC Port Cabinets 6 Connect ICC Cables If the new port cabinet is cabinet B” of a critical reliability EPN, install ICC cables. 1. Connect the cables to the “ICC” block on expansion control cabinet A and port cabinet B. Install each cable so the dark stripe on the cable is on the bottom. See Table 6-10 , Figure 6-27, and Figure 6-28. Figure 6-27. ICC Pin-Field Blocks on J58890N Expansion Control Cabinet Table 6-10. Intercabinet Cable Connections Connect ICC Cables From To CarrierPin-Field Block CarrierPin-Field Block EPN J58890N ICCA ICCBJ58890H ICCA ICCB 114 25 12 24 00 00 20 19 20 19 0 3 2 1 2 1 2 1 ICCB ICCA TERM CURL Pinfield