Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-17 Installing Fiber Optic Cable Pass-Thru Kit (SCC) 6 Figure 6-11. Install the Rear Panels 15. Replace the front cover panel. 16. Discard the pass-thru tool. Test the Installation 1. Log into the management terminal. 2. Administer the system by referring to the ATM section. 3. Type list configuration all and press En t e r to determine if the new circuit pack appears in the correct slot and that there are no circuit pack conflicts. fodapnlb LJK 041398
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-18 Adding External Modem to EPN 6 Adding External Modem to EPN U.S. Robotics Model 839 External Modem Figure 6-12. Connect External Modem to EPN 1. Connect an RS-232 cable to the modem. See Figure 6-12 . NOTE: The following steps refer to a PC or laptop with Windows 95 or Windows NT 4.0. Use the Hyperterminal (terminal emulation) application. 2. Connect the opposite end of the RS-232 cable to a PC. 3. Set the PC to full duplex mode. 4. Type AT&N6 to set the baud rate to 9600. NOTE: The modem connects at 9600 baud but throughput is at 1200 baud. 5. Type AT & W 0 to save the setting into non-volatile RAM. 6. Set Switch 5 to the OFF (up) position to disable auto answer. 7. Disconnect the RS-232 cable from the PC and connect it to the TERM connector on the rear of the system cabinet. Figure Notes: 1. U.S. Robotics External Modem 2. RS-232 Cab le3. Expansion Port Network cydfepns KLC 100397 1 3 2
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-19 Add CO, FX, WATS, and PCOL 6 Add CO, FX, WATS, and PCOL Requirements Each Central Office (CO), Foreign Exchange (FX), Personal Central Office Line (PCOL), or Wide Area Telecommunications Service (WATS) trunk connects to 1 port of either an 8-port TN747B or TN797 or to 1 of several CO trunk circuit packs. Installation 1. Determine the port assignment of the trunk from the Trunk Group form. 2. Install a TN747B or a CO Trunk circuit pack in the assigned carrier slot (if an additional circuit pack is required). 3. Administer the forms listed under CO, FX, WATS, or PCOL Trunk Group in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Add DID Trunks Requirements Each Direct Inward Dial (DID) trunk connects to 1 port DID Trunk circuit pack or to 1 port of an assortment of DID trunk circuit packs. Installation 1. Determine the port assignment of the trunk from the Trunk Group form. EXAMPLE:3A0701 Cabinet (Port Network)Carrier Slot NumberPort Number EXAMPLE:3A0701 Cabinet (Port Network)Carrier Slot NumberPort Number
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-20 Add Tie Trunks 6 2. Install a DID Trunk circuit pack in assigned carrier slot (if an additional circuit pack is required). 3.Administer forms listed under “DID Trunk Group” in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Add Tie Trunks Requirements Each tie trunk connects to 1 port of a 4-port tie trunk circuit pack or to an assortment of international tie trunk circuit packs. Installation 1. Determine the port assignment of the trunk from the trunk group screen. 2. Install the tie trunk or an international tie trunk circuit pack in assigned carrier slot (if an additional circuit pack is required). 3. For customer-owned (not leased) tie-trunk facilities (such as campus environments), tie trunk circuit packs provide signaling capabilities beyond those specified by the industry-wide E&M standard. Use Figure 6-13 and Table 6-3 to choose the preferred signaling format, set switches on the circuit pack, and administer the port. 4.Administer forms listed under “Tie Trunk Group” in the DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . EXAMPLE:3A0701 Cabinet (Port Network)Carrier Slot NumberPort Number
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-21 Add DS1 Tie and OPS 6 Figure 6-13. Tie Trunk Circuit Packs (Component Side) Add DS1 Tie and OPS The TN722B DS1 Tie Trunk and TN767B (or later) DS1 Interface circuit packs provide connections to a 1.544-Mbps DS1 facility (T1) as 24 independent 64-kbps trunks. The TN722B DS1 Tie Trunk, and TN464C (or later) DS1 Interface circuit packs provide connections to a 2.048-Mbps DS1 facility (E1) as 32 independent 64-kbps trunks. Table 6-3. Tie Trunk Option-Switch Settings and Administration Installation Situation Preferred Signaling FormatE&M/SMPLX SwitchProt/Unprot SwitchAdministered Port Circumstance To System Far-End Collocated DEFINITY E&M Type 1 E&M Type 1 E&M Unprotected Type 1 Compatible Standard Compatible Inter-Building DEFINITY Protected Type 1Protected Type 1E&M Protected Type 1 Compatible Standard PlusCompatible Protection Unit Collocated Net IntegratedE&M Type 1 Any PBX E&M Unprotected Type 1 Standard 4321 PORT 4 PORT 3PORT 2PORT 1 UNPROT PROTSMPLX E&M SMPLX E&MSMPLX E&MSMPLX E&M
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-22 Add Speech Synthesis 6 Service Interruption 1. Since the addition of DS1 tie-trunk service may require a service interruption, notify the customer in advance as to when the addition will occur. 2. For information about administering DS1 Tie Trunks, refer to DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Add Speech Synthesis The Speech Synthesizer circuit pack is required when the Voice Message Retrieval, Automatic Wakeup, or Do Not Disturb features are activated. The circuit pack does not require administration. 1. Determine the port assignment of the Speech Synthesizer circuit pack being added. 2. Install the Speech Synthesizer circuit pack in the designated carrier slot. Add Code Calling Access The tones for the Code Calling feature are generated by the Tone-Clock circuit packs in the port networks. 1. Install an Auxiliary Trunk circuit pack or a Speech Synthesizer circuit pack and connect for Loudspeaker Paging. The Code Calling Access feature shares the same ports as Loudspeaker Paging. An Auxiliary Trunk circuit pack provides 4 ports for Loudspeaker Paging and Code Calling Access. 2.Administer the form listed under “Code Calling Access” in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Add Pooled Modem Modem pooling supports two types of conversion resources: integrated and combined. An integrated conversion requires a Pooled Modem circuit pack for each 2 conversion resources provided. A combined conversion requires a port of a TN745B or TN2136 Digital Line circuit pack and a port of either an 8-port TN742, TN769, a 16-port TN746B, or a 24-port TN793/B, TN2793/B Analog Line circuit pack for each conversion resource provided.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-23 Add Pooled Modem 6 The pooled modem requires a Lucent WP90110 L7 power supply. Although integrated conversion can use either the L5 or L7, the combined only works with an L7. !CAUTION: The L5 and L7 power supplies look identical. Check the label to be sure you have the L7 before installing. 1. Determine the port assignment of the circuit packs to be added (if required). 2. Install the appropriate circuit packs in assigned carrier slot (if required). 3. For Paradyne 3800 series modems: a. Type AT&F&D2&S4\D3S2=128x7V2S7=60S85=1 and press En t e r. b. Type ATY0S10=100S78=2M0E0\N1&W and press En t e r. 4.For other types of modems, refer to the vendor’s documentation. Settings for Modem Connected to Data Module 1. Type add data-module next and press En te r. 2. Type pdm in the Type field. 3. Type x in the Port field. 4. Type dte in the Connected to field and press En t e r. 5. Type add station next and press En te r. 6. Type 2500 in the Type field. 7. Type x in the Port field. 8. Type n in the Tests field and press En te r. 9. Type add modem-pool next and press En t e r. 10. Type combined in the Group Type field. 11. Type 5 in the Hold Time (min) field. 12. Type two-way in the Direction field. 13. Type 9600 in the Speed field. 14. Type Full in the Duplex field. 15. Type async in the Synchronization field. 16. Type the port pair assignments in the Analog and Digital fields and press En t e r.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-24 Add Multiple Integrated Recorded Announcement 6 Settings for Modem Connected to the Data Terminal Equipment (DTE) 1. Type add station next and press En te r. 2. Type 2500 in the Type field. 3. Type the port assignment in the Port field and press En t e r. Add Multiple Integrated Recorded Announcement TN750C circuit packs are required if the system has multiple announcement circuit packs. Up to 5 TN750Cs are allowed in a Release 8. The announcements from a TN750 or TN750B can be copied to a TN750C. !CAUTION: Do not copy or restore announcements from a TN750C to a TN750 or TN750B circuit pack, as this process may corrupt the announcement data. 1. Install the TN750C circuit pack into any port or service (TDM) slot. NOTE: Only 1 TN750 or TN750B can reside in the system with a TN750C. The TN750C need not reside in a control carrier for extra power holdover. TN750C Announcement Circuit Pack The TN750C circuit pack contains on-board flash memory that provides internal backup of announcements. Thus, the TN750C circuit pack does not need the save and restore processes. The TN750C circuit pack can replace a TN750 or TN750B. The difference in operation is that the TN750C automatically restores and reports the availability of announcements from its own internal flash memory in 5 minutes, rather than the 40 minutes for the TN750 or TN750B. If a circuit pack already has announcements in its flash memory, the yellow LED flashes as the announcements copy to the voice RAM.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-25 Add Multiple Integrated Recorded Announcement 6 Save and Restore Recorded Announcements !CAUTION: If the yellow LED is flashing, do not remove the circuit pack, as this will corrupt the announcement data. 1. Type save announcements and press En t e r. 2. To restore announcements, type restore announcements to and press En te r. After 5 minutes (with no alterations to the announcements), the TN750C automatically copies the announcements from the voice RAM to the internal flash memory. The yellow LED on the front of the TN750C flashes. You can only save the announcement contents of 1 circuit pack at a time. For the contents of every circuit pack, save to separate translation cards. Label each translation card so that it matches the circuit pack. TN750 and TN750B Announcement Circuit Packs To save the recorded announcements in the system, type save announcements and press En t e r. Use these codes after business hours or when the system is operating during a low-usage period. The system takes about 40 minutes to transfer the recorded announcements from the announcement circuit pack to the translation card. During this time, the management terminal cannot be used to administer the system; however, all other administration terminals, if provided, are allowed to perform administration procedures. Ty p e restore announcements and press En t e r to restore the recorded announcements from the translation card to system memory. Replace a TN750/B with a TN750C or Move all Announcements from a TN750/B to a TN750C Use this procedure to replace a TN750/B circuit pack with a TN750C circuit pack or to move every announcement from a TN750/B to a TN750C. !CAUTION: Do not copy or restore announcements from a TN750C to a TN750 or TN750B circuit pack, as this may corrupt the announcement data. 1. Save announcements from the TN750/B to the translation card. 2. Insert the TN750C into a vacant slot of a carrier.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-26 Add Multiple Integrated Recorded Announcement 6 3. Type add data-module next and press En te r to administer a new data module on the TN750C. 4. Type announcement in the Type field. 5. Type the location in the Board field and submit the form. 6. Type restore announcements for the TN750C. Wait until announcements copy from voice RAM to flash memory (yellow LED on the TN750C stops flashing). This may take about 10 minutes. 7. Type busyout board and press En t e r for the TN750/B. 8. Type change integrated announcements and press En t e r. This modifies the translations for the TN750/B to reference the TN750C circuit pack. 9. Verify proper playback of the announcements from the TN750C. 10. Type release board and press En te r for the TN750/B. 11. Remove the TN750/B circuit pack if it is no longer necessary. Add TN750C Circuit Packs 1. Insert the TN750C into a vacant slot in a carrier and administer a new data module on the TN750C, as described in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . 2. To administer new announcements to that TN750C slot, type change announcements and press En t e r. 3. Record the announcements, as described in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Wait until the announcements copy from voice RAM to the onboard flash memory (the yellow LED on the TN750C starts and then stops flashing). This takes about 10 minutes. Move a Single Announcement to Another Announcement Circuit Pack 1. Type change announcements and press En t e r to change the circuit pack locations of a particular announcement. (You may also change the compression rate at this time.) 2. Move the announcement, as described in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide .