Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 What’s New in Release 8.2si xi Discontinued hardware No equipment was discontinued with Release 8.2si. To o l s No new tools became available with Release 8.2si. Commands, screens, and fields The following commands and screens are new to or affected by Release 8.2si. The number of screens has changed, and some fields have moved to different screens. Procedures The following procedures and steps changed or were added because of problems identified in the laboratory or during early introduction. Many of the upgrade procedures were reordered and the steps within the procedure better defined. Check the task tables at the beginning of each upgrade chapter for the current order. Also, to reduce redundancy in the book, there is no longer a separate upgrade process for high or critical reliability. The procedures and steps that apply to high or critical reliability are noted where they occur in the upgrade process. Command/field Screen Notes reset translation-idSystem Parameters Security This command resets the translation-ID on the translation card to match the processor; saves translations to the memory card; and restores use of the add, change, remove, and duplicate commands. Needs init login to correct TRANS-ID alarm.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 What’s New in Release 8.2si xii Upgrade tips The following upgrade tips were generated from problems identified in the laboratory or during early introduction. nThe pooled modem requires a Lucent WP90110 L7 power supply. Although integrated conversion can use either the L5 or L7, the combined only works with an L7. Cautions and warnings The following new cautions and warnings were generated from problems affecting possible data loss that were identified in the laboratory or during early introduction. Procedure Steps Notes Check SPE 1. Type status system 1 and press En t e r to check the health of the system.Becomes first step of upgrade procedure Check Link Status 1. Type display communication-interface links and press En t e r. Write down all enabled links. 2. Type status link number and press En t e r for each enabled link. 3. Write down which links are in service. This optional step is to make sure the settings are the same after the upgrade. This step was simplified. Resolve Alarms 1. Type display alarms and press En t e r to examine the alarm log. Extra step before upgrading the software to make sure no alarms exist before the upgrade. Procedure Caution or Warning Add Pooled Modem !CAUTION: The L5 and L7 power supplies look identical. Check the label to be sure you have the L7 before installing.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 What’s New in Release 8.2si xiii Product names The following products have been renamed. Product name Old name IP Interface Assembly (TN802B)IP trunk (TN802)
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 What’s New in Release 8.2si xiv
About This Book xv Offer Categories DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 About This Book This book provides the procedures for upgrading existing systems to a DEFINITY® Enterprise Communications Server Release 8.2. This book also contains instructions for adding equipment to an existing Release 8.2 system. This document covers information related to DEFINITY ECS Release 8.2 and is intended for use by a trained installation technician. Offer Categories Features are limited depending on the category purchased by the customer. Offer Category A allows access to all DEFINITY features. Offer Category B allows access to a subset of DEFINITY features. Contact your Lucent Technologies representative for more information. Security Issues To ensure the greatest security possible for customers, Lucent Technologies offers services that can reduce toll-fraud liabilities. Contact your Lucent Technologies representative for more security information. Login security is an attribute of the DEFINITY ECS software. Existing passwords expire 24 hours after installation. For Access Security Gateway (ASG), see Appendix A, ‘‘Administering and Using ASG’’.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 About This Book xvi Upgrade Paths Upgrade Paths Table 1 correlates each upgrade to an associated chapter number. NOTE: The oldest load that can be directly upgraded to R6 is V2 4.5. If the existing load is older than that, it must first be upgraded to V2 4.5. This can be done with Remediation 687DR. Also, the existing load must be V1 8.0 or later to update to V2 4.5. If it is not, it can be upgraded to 8.0 with Remediation 645DR. NOTE: To upgrade G3 systems to at least G3V4, refer to DEFINITY Communications System Generic 3vs and Generic 3si Upgrades and Additions , 555-230-108. NOTE: For G3 systems containing the XE control carrier, refer to DEFINITY Communications System Generic 3vs and Generic 3si Upgrades and Additions , 555-230-108 for details on upgrading the control carrier to the ESCC control carrier supported in Release 8. Table 1. Software and Hardware Upgrade Chapters Description Chapter Upgrading G3vs (w/Intel 386) to R8si 1 Upgrading R5vs/R6vs to R8si 2 Upgrading G3s/si (w/Intel 386) to R8si 3 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4 Upgrading R7si to R8si 5 Adding or Removing Hardware 6
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 About This Book xvii Related Documents The following table indicates the processes and their corresponding time allotment. Not all processes are required for every upgrade; the table shows maximum times and includes high and critical reliability processes. Related Documents As supplemental information, the following books may be required to perform upgrades and additions to DEFINITY ECS Release 8 systems: nBCS Products Security Handbook nDEFINITY Enterprise Communications Server Release 8 Installation for Adjuncts and Peripherals nDEFINITY Enterprise Communications Server Release 5 Installation and Upgrades for CSCC nDEFINITY Enterprise Communications Server Release 8 Installation and Test for Single-Carrier Cabinets nDEFINITY Enterprise Communications Server Release 8 Administrator’s Guide nDEFINITY Enterprise Communications Server Release 8 Maintenance for R8si nDEFINITY Enterprise Communications Server Release 8 Maintenance for R8csi nDEFINITY Enterprise Communications Server Release 8 System Description Process Minutes Save translations 10 Busyout/release multimedia interface circuit packs 2 Disable/enable TTI 2 Disable/enable scheduled maintenance and alarm origination2 Save announcements (TN750/B Only) 40 Restore announcements (TN750/B Only) 40 List configuration software long 5 Shutdown/restart AUDIX and LAN Gateway 20 Reboot and upgrade software 15 Remove PRI/PI links 15 Miscellaneous 15
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 About This Book xviii Conventions Used in This Book nDEFINITY Enterprise Communications Server Release 8 Administration for Network Connectivity nSwitch Administration for DEFINITY AUDIX Conventions Used in This Book This book uses the following conventions: nKeyboard keys are shown as: En te r. nInformation you type is shown as: save announcements. To submit the command you typed, press the En te r key in the numbers section of the keyboard, not the En te r/Re t u r n key in the letters section. nInformation displayed on the screen is shown as: login: nCircuit pack codes (for example, TN772 or TN754B) are shown with the minimum acceptable alphabetic suffix (like the ‘‘B” in the code ‘‘TN754B”). Generally, an alphabetic suffix higher than the 1 shown is also acceptable. However, not every vintage of either the minimum suffix or a higher suffix code is necessarily acceptable. NOTE: Refer to Technical Monthly: Reference Guide for Circuit Pack Vintages and Change Notices , for current information about the usable vintages of specific circuit pack codes (including the suffix) in a DEFINITY ECS Release 8 system. The following conventions are used to describe the systems referred to in this book. nThe word system, is a general term encompassing Release 8 and includes references to the DEFINITY Enterprise Communications Server nSystems in this book are called: G3V4, Release 5, Release 6, Release 7, and Release 8 nOlder DEFINITY Communications Systems Generic 3vs, Generic 3s, and Generic 3i are referred to as G3vs, G3s, and G3i nAll occurrences of G3s, G3i, G3siV4, G3siV4+m, Release 5si, Release 5si + memory, and Release 6si are called Release 6si unless a specific configuration is required to differentiate between product offerings nInformation in this book is applicable for G3V4 through Release 8, unless otherwise specified nDEFINITY Enterprise Communications Server is abbreviated as DEFINITY ECS
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 About This Book xix How to Order Books How to Order Books In addition to this book, other description, installation and test, maintenance, and administration books are available. A complete list of DEFINITY books can be found in the Business Communications System Publications Catalog, 555-000-010. This book and any other DEFINITY books can be ordered directly from the Lucent Technologies Business Communications System Publications Fulfillment Center at 1-317-322-6791 or toll free at 1-800-457-1235. How to Comment on This Book Lucent Technologies welcomes your feedback. Please fill out the reader comment card found at the front of this manual and return it. Your comments are of great value and help improve our documentation. If the reader comment card is missing, FAX your comments to 1-303-538-1741 or to your Lucent Technologies representative, and mention this book’s name and number, DEFINITY Enterprise Communication Server Release 8 Upgrades and Additions for R8si, 555-233-104. LASER Product DEFINITY ECS may contain a Class 1 LASER device if single-mode fiber optic cable is connected to a remote Expansion Port Network (EPN). The LASER device operates within the following parameters: Maximum Power Output: -5 dBm Wavelength: 1310 nm Mode Field Diameter: 8.8 mm CLASS 1 LASER PRODUCT IEC 825 1993 !CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Contact your Lucent Technologies representative for more information.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 About This Book xx Where to Call for Technical Support Single-Mode Fiber Attenuators Attenuators may be required when using single-mode fiber. See the table below. A different value attenuator may be required on the transmit side versus the receive side, even though the fiber span is between the same 2 cabinets (local and remote cabinet). Refer to DEFINITY Enterprise Communications Server Release 8 Installation and Test for Multicarrier Cabinets for detailed fiber attenuator information. Where to Call for Technical Support Use the telephone numbers in the following table for technical support.106060718 5 dB attenuator 2 for each fiber connection 106060734 10 dB attenuator 2 for each fiber connection Te l e p h o n e N u m b e r DEFINITY Helpline (feature administration and system applications)1-800-225-7585 Lucent Technologies Toll Fraud Intervention 1-800-643-2353 Lucent Technologies National Customer Care Center 1-800-242-2121 Lucent Technologies Corporate Security 1-800-822-9009 Streamlined Implementation (for missing equipment) 1-800-772-5409 USA/Canada Technical Service Center 1-800-248-1234 ITAC 1-303-804-3777 Lucent Technologies Centers of Excellence Asia/Pacific Regional Support Center 65-872-8686 Western Europe/Middle East/South Africa 44-1252-77-4800 Central/Eastern Europe 361-345-4334 Central/Latin America Caribbean 1-303-804-3778 Australia 61-2-9352-9090 North America (INADS Database Administration) 1-800-248-1111