    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-27 Add ISDN — PRI 
    6
    Add ISDN — PRI
    North American
    1. Install a TN767E (or later) DS1 or a TN464F DS1/E1 circuit pack for a 
    signaling link and up to 23 ISDN — PRI Trunk Group members. 
    2. Install a Tone-Clock circuit pack to provide synchronization for the DS1 
    circuit pack. 
    If using a TN464F, then packet bus support has not been added, requiring more 
    than 8 PRI signaling groups in an MCC or 4 PRI signaling groups in an SCC. See 
    ‘‘Add Packet Bus Support’’ on page 6-28
     for adding circuit packs for packet bus 
    support.
    As an option to the TN768 or TN2182B Tone-Clock, a TN780 Tone-Clock 
    (installed in the PPN) can interface external Stratum 3 synchronization for DS1.
    International
    1. Install a TN464C (or later) DS1/E1 circuit pack for the assignment of the 2 
    signaling channels and up to 30 ISDN — PRI Trunk Group members. Each 
    E1 span provides 32 ports. 
    2. Install a Tone-Clock circuit pack to provide synchronization for the DS1/E1 
    circuit pack.
    If using a TN464F, then packet bus support has not been added, requiring more 
    than 8 PRI signaling groups. See ‘‘Add Packet Bus Support’’ on page 6-28
     for 
    adding circuit packs for packet bus support.
    As an option to the TN768 or TN2182B Tone-Clock, a TN780 Tone-Clock 
    (installed in the PPN) can interface external Stratum 3 synchronization for DS1.
    Service Interruption
    1. If packet bus support must be added and TN750s must be installed as part 
    of that support, then adding ISDN — PRI requires a service interruption. 
    Notify the customer in advance as to when the addition will be carried out. 
    See ‘‘Add Packet Bus Support’’ on page 6-28
     for fur ther information.
    Add Packet Bus Support
    1. If packet bus support is not already installed, see ‘‘Add Packet Bus 
    Support’’ on page 6-28 and perform the steps. 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-28 Add Packet Bus Support 
    6
    Add Circuit Packs
    1. Determine port assignment of circuit packs to be added.
    2. Install the DS1 Interface circuit pack in the assigned carrier slot.
    3. Remove an existing TN756 Tone Detector/Generator circuit pack and 
    install the TN768, TN780, TN2182B, or TN419B Tone-Clock circuit pack in 
    assigned carrier slots, if required.
    4. Install a Tone Detector circuit pack if required.
    Install Cables
    1. Install cables from the TN464F to the MDF as required.
    Enter Added Translations
    1.Administer the forms listed under “Integrated Services Digital Network — 
    Primary Rate Interface” in 
    DEFINITY Enterprise Communications Server 
    Release 8 Administrator’s Guide
    .
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY 
    Enterprise Communications Server Release 8 Maintenance for R8si
    . 
    Save Translations
    1. If the system is high or critical reliability, type status system 1 and press 
    En t e r to verify that the system is in the active or standby mode.
    2. Type save translation and press 
    En te r. This instructs the system to take all 
    translation information in memory and write it to the translation cards.
    3. Update backup cards, if necessary.
    Add Packet Bus Support
    Service Interruption
    If no TN570s need to be installed for packet bus support, skip to and perform only 
    the Install Circuit Packs section. This procedure does not interrupt service in this 
    case. 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-29 Add Packet Bus Support 
    6
    Disable Alarm Origination
    1. Type change system-parameters maintenance and press En te r. 
    2. Set the Alarm Origination Activated field to n.
    !CAUTION:
    If you do not disable Alarm Origination, the system may generate 
    alarms, resulting in unnecessary trouble tickets. 
    3. For some releases of software, disable Cleared Alarm Notification 
    and Restart Notification before submitting the form.
    Save Translations
    1. If the system is high or critical reliability, type status system 1 and press 
    En t e r to verify that the system is in the active or standby mode.
    2. Type save translation and press 
    En te r. This instructs the system to take all 
    translation information in memory and write it to the translation card.
    3. If the system contains a TN750/B Announcement circuit pack, type display 
    announcements and press 
    En t e r. If administered recorded announcements 
    are listed, type list configuration software-version long and press 
    En te r. 
    To save the announcements, type save announcements and press 
    En t e r.
    Power Down Cabinet 
    1. At the PPN, set the main circuit breaker to OFF.
    2. At an EPN, set the main circuit breaker to OFF. 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-30 Add Packet Bus Support 
    6
    Install Circuit Packs
    1. Install the appropriate circuit packs. See Table 6-4.
    Power Up System
    1. At the EPN, set the main circuit breaker to ON.
    2. At the PPN, set the main circuit breaker to ON.
    3. The system performs a level 4 reboot, loading the system translations from 
    the translation cards. Rebooting takes about 10 minutes.
    4. After all trouble is cleared, verify the EMERGENCY TRANSFER 
    CONTROL switch is set to AUTO. This restores the system to the normal 
    mode.
    Test the Packet Bus and C-LAN Circuit Pack
    1. Type test pkt port-network 1 long and press En te r. For more 
    detail about these tests, refer to the test pkt command section in the 
    DEFINITY Enterprise Communications Server Release 8 Maintenance for 
    R8si
    . 
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms using DEFINITY Enterprise 
    Communications Server Release 8 Maintenance for R8si
    . 
    Table 6-4. Circuit Pack Locations for Packet Bus in PPN
    Circuit Pack Carrier Quantity Slot
    TN570 Control Carrier A
    Control Carrier B 
    (H/C only)1 or 2
    1
    1 or 2
    1. Quantity of this pack should equal the number of EPNs.
    EXPN INTFC/1 and /2
    EXPN INTFC/1 and /2
    TN771C Control Carrier A 1
    2
    2. Required for critical-reliability EPNs and PPN. Optional for digital trunk testing in
    high-reliability PPN.
    Any Available Port Slot 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-31 Add Packet Bus Support 
    6
    Enable Customer Options and Alarm Origination
    1. Get the DOSS order number of the upgrade from the project manager and 
    ask the regional Customer Software Administration to complete the steps 
    in the shaded box. See ‘‘Where to Call for Technical Support’’ on page -xx
     
    for telephone numbers.
    NOTE:
    As part of the system registration process, the INADS Database 
    Administrator enables Alarm Origination.
    2. When administration is completed, log in as craft at the Login: prompt.
    Save Translations
    1. If high or critical reliability system, type status system 1 and press En te r to 
    verify that the system is in the “active/standby” mode.
    2. Type save translation and press 
    En te r. This instructs the system to take all 
    translation information in memory and write it to the translation flashcards.
    3. If the system contains a TN750/B/C Announcement circuit pack, type 
    restore announcements and press 
    En te r.
    Update backup flashcards, if necessary.
    init login administration:
    1. Log in as init.
    2. Type change system-parameters customer-options and press 
    En t e r 
    to verify that the customer options are properly set.
    3. Go to screen 6, QSIG Optional Features, and set the Basic Call 
    Setup field to y if the customer was using Supplementary Services 
    Protocol b or d on an ISDN-PRI trunk group before the upgrade.
    4. Type change system-parameters offer-options and press 
    En t e r.
    5. If the Activate Offer field is n, set it to y and press 
    Ta b. A warning 
    message lets you know whether you need to save translations and 
    reboot to make the change permanent.
    6. Press 
    En te r to effect the changes or Canc el if there were no changes.
    7. Contact the requester when done. 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-32 Add CallVisor ASAI 
    6
    Add CallVisor ASAI
    Service Interruption
    1. If adding the packet bus support and TN570s must be installed as part of 
    that support, then adding CallVisor ASAI requires a service interruption. 
    Notify the customer in advance as to when the addition will take place. See 
    ‘‘Add Packet Bus Support’’ on page 6-28
     for further information.
    Enter Added Translations
    1. On the System-Parameters Customer-Options form, disable the Calling 
    Party Number/Billing Number (CPN/BN) option, and enable the CallVisor 
    ASAI Interface option. 
    2. See 
    DEFINITY Enterprise Communications Server Release 8 
    Administrator’s Guide
    , for details on disabling and enabling these options.
    Save Translations
    1. If the system is high or critical reliability, type status system 1 and press 
    En t e r to verify that the system is in the active or standby mode.
    1. Type save translation and press 
    En te r. This instructs the system to take all 
    translation information in memory and write it to the translation cards.
    Add Packet Bus Support
    1. If packet bus support is not already installed, see ‘‘Add Packet Bus 
    Support’’ on page 6-28 and perform the steps.
    Add Circuit Packs
    1. Determine port assignment of circuit packs to be added.
    2. Install the appropriate circuit packs in assigned carrier slot (as required).
    The TN748B (or later) or TN744/C/D Call Classifier circuit pack is required. 
    The TN744/C/D is required for those customers who want switch call 
    classification.
    A vacant port is required on a TN556/B/C ISDN—BRI circuit pack. EXAMPLE:3A0701
    Cabinet (Port 
    Network)Carrier Slot 
    NumberPort 
    Number 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-33 Add DCS Interface 
    6
    Install Cables
    1. Install cables from TN464F to the MDF as required.
    Enter Added Translations
    1. Administer the required translation data using the forms listed under 
    “Adjunct/Switch Applications Interface (ASAI)” in 
    DEFINITY Enterprise 
    Communications Server Release 8 Administrator’s Guide
    .
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY 
    Enterprise Communications Server Release 8 Maintenance for R8si
    . 
    Save Translations
    1. If the system is high or critical reliability, type status system 1 and press 
    En t e r to verify that the system is in the active or standby mode.
    1. Type save translation and press 
    En te r. This instructs the system to take all 
    translation information in memory and write it to the translation cards.
    2. Update backup translation cards, if required.
    Add DCS Interface
    Systems in a Distributed Communications System (DCS) network are 
    interconnected by both tie trunks (for voice communications) and data links (for 
    control and transparent feature information). These data links, also called DCS 
    signaling links, support the feature transparency. 
    Various subsets (depending on the specific configuration) of DS1 Interface circuit 
    packs (including TN464C, TN767C, TN722, and TN760) provide the 
    voice-communications interface.
    Meanwhile, the data link interface (between the processor and the physical 
    signaling link) is provided by (or through) a TN799 Control-LAN circuit pack. In 
    some configurations, the TN799 passes the signaling information over a separate 
    10BaseT TCP/IP network (usually via a hub). For use with 10BaseT, connect the 
    appropriate pins of the I/O field to the hub. For pinouts and diagrams, refer to the 
    installation manual. In other configurations, the TN799 circuit pack carries 
    signaling over point-to-point protocol (PPP) for subsequent inclusion (via the 
    switching fabric) in the same DS1 bit stream as the DSC voice transmissions.
    As an option to the TN768 Tone-Clock, a TN780 Tone-Clock circuit pack (installed 
    in the PPN) can interface external Stratum 3 synchronization for DS1 connections. 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-34 Add DCS Interface 
    6
    For further information about DCS, refer to the following documents:
    nAT&T System 75/85 Network and Data Services Reference Manual
    nSystem 75 Application Notes Network Services
    nDEFINITY ECS Release 8 Administration for Network Connectivity
    Add Circuit Packs
    A TN464C, TN767C, TN722, or TN760 DS1 circuit pack is required for PPP 
    connections. A TN799 C-LAN circuit pack is required.
    1. Determine the port assignments of the circuit packs to be added. If the 
    processor cabinet has no available por t slots for the C-LAN circuit pack, 
    place it in an EPN cabinet port slot. 
    Install Cables
    1. Install cable from the cabinet to a hub or 110 (purple) wall field as required. 
    Connect the 259A connector to the port slot containing the Control-LAN 
    circuit pack. See Figure 6-14
    . For a pinout of TN799, see Table 6-5.  
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-35 Add DCS Interface 
    6
    Figure 6-14. Cable Connection for C-LAN
    Figure Notes
    1. 259A Connector
    2. DW8 Cable3. Hub or 110 (purple) wall field
    Table 6-5. TN799 Pinout
    Backplane Pin 25-Pair Wire Color Lead NamePeripheral 
    Connector Pin
    103 White/Orange TD+ 27
    003 Orange/White TD- 2
    104 White/Green RD+ 28
    004 Green/White RD- 3
    1
    2
    3cydflan2  EWS 101398 
    						
    							DEFINITY ECS Release 8.2
    Upgrades and Additions for R8.2si  555-233-122  Issue 1
    April 2000
    Adding or Removing Hardware 
    6-36 Add ISDN—BRI 
    6
    Enter Added Translations
    1. Get the DOSS order number of the upgrade. Call the regional CSA to 
    perform the steps in this section.
    2. To enable DCS, set the DCS field on the System Parameters-Customer 
    Options form to y.
    3. Administer the other required translation data using the forms listed under 
    Distributed Communications System (DCS) in 
    DEFINITY Communications 
    System Administration for Networking Connectivity
    . 
    Save Translations
    1. If the system is high- or critical-reliability, type status system 1 and press 
    En t e r  to verify that the standby SPE is refreshed and that the standby disk is 
    in service.
    2. Type save translation [spe-a or both] and press 
    En t e r to instruct the 
    system to copy the translation information to the disk(s).
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY 
    Enterprise Communications Server Release 8 Maintenance for R8si.
     
    Remove TN771
    1. If you added TN771 to the PPN only (for the packet bus support in the DCS 
    feature), remove it from the PPN.
    Add ISDN—BRI
    Service Interruption
    1. If adding the packet bus support and TN570s must be installed as part of 
    that support, adding ISDN—BRI requires a service interruption. Notify the 
    customer in advance as to when the addition will be carried out. See ‘‘Add 
    Packet Bus Support’’ on page 6-28 for further information.
    Add the Packet Bus Support
    1. If packet bus support is not already installed, see ‘‘Add Packet Bus 
    Support’’ on page 6-28 and perform the steps. 
    						