Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-27 Add ISDN — PRI 6 Add ISDN — PRI North American 1. Install a TN767E (or later) DS1 or a TN464F DS1/E1 circuit pack for a signaling link and up to 23 ISDN — PRI Trunk Group members. 2. Install a Tone-Clock circuit pack to provide synchronization for the DS1 circuit pack. If using a TN464F, then packet bus support has not been added, requiring more than 8 PRI signaling groups in an MCC or 4 PRI signaling groups in an SCC. See ‘‘Add Packet Bus Support’’ on page 6-28 for adding circuit packs for packet bus support. As an option to the TN768 or TN2182B Tone-Clock, a TN780 Tone-Clock (installed in the PPN) can interface external Stratum 3 synchronization for DS1. International 1. Install a TN464C (or later) DS1/E1 circuit pack for the assignment of the 2 signaling channels and up to 30 ISDN — PRI Trunk Group members. Each E1 span provides 32 ports. 2. Install a Tone-Clock circuit pack to provide synchronization for the DS1/E1 circuit pack. If using a TN464F, then packet bus support has not been added, requiring more than 8 PRI signaling groups. See ‘‘Add Packet Bus Support’’ on page 6-28 for adding circuit packs for packet bus support. As an option to the TN768 or TN2182B Tone-Clock, a TN780 Tone-Clock (installed in the PPN) can interface external Stratum 3 synchronization for DS1. Service Interruption 1. If packet bus support must be added and TN750s must be installed as part of that support, then adding ISDN — PRI requires a service interruption. Notify the customer in advance as to when the addition will be carried out. See ‘‘Add Packet Bus Support’’ on page 6-28 for fur ther information. Add Packet Bus Support 1. If packet bus support is not already installed, see ‘‘Add Packet Bus Support’’ on page 6-28 and perform the steps.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-28 Add Packet Bus Support 6 Add Circuit Packs 1. Determine port assignment of circuit packs to be added. 2. Install the DS1 Interface circuit pack in the assigned carrier slot. 3. Remove an existing TN756 Tone Detector/Generator circuit pack and install the TN768, TN780, TN2182B, or TN419B Tone-Clock circuit pack in assigned carrier slots, if required. 4. Install a Tone Detector circuit pack if required. Install Cables 1. Install cables from the TN464F to the MDF as required. Enter Added Translations 1.Administer the forms listed under “Integrated Services Digital Network — Primary Rate Interface” in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Release 8 Maintenance for R8si . Save Translations 1. If the system is high or critical reliability, type status system 1 and press En t e r to verify that the system is in the active or standby mode. 2. Type save translation and press En te r. This instructs the system to take all translation information in memory and write it to the translation cards. 3. Update backup cards, if necessary. Add Packet Bus Support Service Interruption If no TN570s need to be installed for packet bus support, skip to and perform only the Install Circuit Packs section. This procedure does not interrupt service in this case.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-29 Add Packet Bus Support 6 Disable Alarm Origination 1. Type change system-parameters maintenance and press En te r. 2. Set the Alarm Origination Activated field to n. !CAUTION: If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets. 3. For some releases of software, disable Cleared Alarm Notification and Restart Notification before submitting the form. Save Translations 1. If the system is high or critical reliability, type status system 1 and press En t e r to verify that the system is in the active or standby mode. 2. Type save translation and press En te r. This instructs the system to take all translation information in memory and write it to the translation card. 3. If the system contains a TN750/B Announcement circuit pack, type display announcements and press En t e r. If administered recorded announcements are listed, type list configuration software-version long and press En te r. To save the announcements, type save announcements and press En t e r. Power Down Cabinet 1. At the PPN, set the main circuit breaker to OFF. 2. At an EPN, set the main circuit breaker to OFF.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-30 Add Packet Bus Support 6 Install Circuit Packs 1. Install the appropriate circuit packs. See Table 6-4. Power Up System 1. At the EPN, set the main circuit breaker to ON. 2. At the PPN, set the main circuit breaker to ON. 3. The system performs a level 4 reboot, loading the system translations from the translation cards. Rebooting takes about 10 minutes. 4. After all trouble is cleared, verify the EMERGENCY TRANSFER CONTROL switch is set to AUTO. This restores the system to the normal mode. Test the Packet Bus and C-LAN Circuit Pack 1. Type test pkt port-network 1 long and press En te r. For more detail about these tests, refer to the test pkt command section in the DEFINITY Enterprise Communications Server Release 8 Maintenance for R8si . Resolve Alarms 1. Examine the alarm log. Resolve any alarms using DEFINITY Enterprise Communications Server Release 8 Maintenance for R8si . Table 6-4. Circuit Pack Locations for Packet Bus in PPN Circuit Pack Carrier Quantity Slot TN570 Control Carrier A Control Carrier B (H/C only)1 or 2 1 1 or 2 1. Quantity of this pack should equal the number of EPNs. EXPN INTFC/1 and /2 EXPN INTFC/1 and /2 TN771C Control Carrier A 1 2 2. Required for critical-reliability EPNs and PPN. Optional for digital trunk testing in high-reliability PPN. Any Available Port Slot
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-31 Add Packet Bus Support 6 Enable Customer Options and Alarm Origination 1. Get the DOSS order number of the upgrade from the project manager and ask the regional Customer Software Administration to complete the steps in the shaded box. See ‘‘Where to Call for Technical Support’’ on page -xx for telephone numbers. NOTE: As part of the system registration process, the INADS Database Administrator enables Alarm Origination. 2. When administration is completed, log in as craft at the Login: prompt. Save Translations 1. If high or critical reliability system, type status system 1 and press En te r to verify that the system is in the “active/standby” mode. 2. Type save translation and press En te r. This instructs the system to take all translation information in memory and write it to the translation flashcards. 3. If the system contains a TN750/B/C Announcement circuit pack, type restore announcements and press En te r. Update backup flashcards, if necessary. init login administration: 1. Log in as init. 2. Type change system-parameters customer-options and press En t e r to verify that the customer options are properly set. 3. Go to screen 6, QSIG Optional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protocol b or d on an ISDN-PRI trunk group before the upgrade. 4. Type change system-parameters offer-options and press En t e r. 5. If the Activate Offer field is n, set it to y and press Ta b. A warning message lets you know whether you need to save translations and reboot to make the change permanent. 6. Press En te r to effect the changes or Canc el if there were no changes. 7. Contact the requester when done.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-32 Add CallVisor ASAI 6 Add CallVisor ASAI Service Interruption 1. If adding the packet bus support and TN570s must be installed as part of that support, then adding CallVisor ASAI requires a service interruption. Notify the customer in advance as to when the addition will take place. See ‘‘Add Packet Bus Support’’ on page 6-28 for further information. Enter Added Translations 1. On the System-Parameters Customer-Options form, disable the Calling Party Number/Billing Number (CPN/BN) option, and enable the CallVisor ASAI Interface option. 2. See DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide , for details on disabling and enabling these options. Save Translations 1. If the system is high or critical reliability, type status system 1 and press En t e r to verify that the system is in the active or standby mode. 1. Type save translation and press En te r. This instructs the system to take all translation information in memory and write it to the translation cards. Add Packet Bus Support 1. If packet bus support is not already installed, see ‘‘Add Packet Bus Support’’ on page 6-28 and perform the steps. Add Circuit Packs 1. Determine port assignment of circuit packs to be added. 2. Install the appropriate circuit packs in assigned carrier slot (as required). The TN748B (or later) or TN744/C/D Call Classifier circuit pack is required. The TN744/C/D is required for those customers who want switch call classification. A vacant port is required on a TN556/B/C ISDN—BRI circuit pack. EXAMPLE:3A0701 Cabinet (Port Network)Carrier Slot NumberPort Number
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-33 Add DCS Interface 6 Install Cables 1. Install cables from TN464F to the MDF as required. Enter Added Translations 1. Administer the required translation data using the forms listed under “Adjunct/Switch Applications Interface (ASAI)” in DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide . Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Release 8 Maintenance for R8si . Save Translations 1. If the system is high or critical reliability, type status system 1 and press En t e r to verify that the system is in the active or standby mode. 1. Type save translation and press En te r. This instructs the system to take all translation information in memory and write it to the translation cards. 2. Update backup translation cards, if required. Add DCS Interface Systems in a Distributed Communications System (DCS) network are interconnected by both tie trunks (for voice communications) and data links (for control and transparent feature information). These data links, also called DCS signaling links, support the feature transparency. Various subsets (depending on the specific configuration) of DS1 Interface circuit packs (including TN464C, TN767C, TN722, and TN760) provide the voice-communications interface. Meanwhile, the data link interface (between the processor and the physical signaling link) is provided by (or through) a TN799 Control-LAN circuit pack. In some configurations, the TN799 passes the signaling information over a separate 10BaseT TCP/IP network (usually via a hub). For use with 10BaseT, connect the appropriate pins of the I/O field to the hub. For pinouts and diagrams, refer to the installation manual. In other configurations, the TN799 circuit pack carries signaling over point-to-point protocol (PPP) for subsequent inclusion (via the switching fabric) in the same DS1 bit stream as the DSC voice transmissions. As an option to the TN768 Tone-Clock, a TN780 Tone-Clock circuit pack (installed in the PPN) can interface external Stratum 3 synchronization for DS1 connections.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-34 Add DCS Interface 6 For further information about DCS, refer to the following documents: nAT&T System 75/85 Network and Data Services Reference Manual nSystem 75 Application Notes Network Services nDEFINITY ECS Release 8 Administration for Network Connectivity Add Circuit Packs A TN464C, TN767C, TN722, or TN760 DS1 circuit pack is required for PPP connections. A TN799 C-LAN circuit pack is required. 1. Determine the port assignments of the circuit packs to be added. If the processor cabinet has no available por t slots for the C-LAN circuit pack, place it in an EPN cabinet port slot. Install Cables 1. Install cable from the cabinet to a hub or 110 (purple) wall field as required. Connect the 259A connector to the port slot containing the Control-LAN circuit pack. See Figure 6-14 . For a pinout of TN799, see Table 6-5.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-35 Add DCS Interface 6 Figure 6-14. Cable Connection for C-LAN Figure Notes 1. 259A Connector 2. DW8 Cable3. Hub or 110 (purple) wall field Table 6-5. TN799 Pinout Backplane Pin 25-Pair Wire Color Lead NamePeripheral Connector Pin 103 White/Orange TD+ 27 003 Orange/White TD- 2 104 White/Green RD+ 28 004 Green/White RD- 3 1 2 3cydflan2 EWS 101398
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Adding or Removing Hardware 6-36 Add ISDN—BRI 6 Enter Added Translations 1. Get the DOSS order number of the upgrade. Call the regional CSA to perform the steps in this section. 2. To enable DCS, set the DCS field on the System Parameters-Customer Options form to y. 3. Administer the other required translation data using the forms listed under Distributed Communications System (DCS) in DEFINITY Communications System Administration for Networking Connectivity . Save Translations 1. If the system is high- or critical-reliability, type status system 1 and press En t e r to verify that the standby SPE is refreshed and that the standby disk is in service. 2. Type save translation [spe-a or both] and press En t e r to instruct the system to copy the translation information to the disk(s). Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Release 8 Maintenance for R8si. Remove TN771 1. If you added TN771 to the PPN only (for the packet bus support in the DCS feature), remove it from the PPN. Add ISDN—BRI Service Interruption 1. If adding the packet bus support and TN570s must be installed as part of that support, adding ISDN—BRI requires a service interruption. Notify the customer in advance as to when the addition will be carried out. See ‘‘Add Packet Bus Support’’ on page 6-28 for further information. Add the Packet Bus Support 1. If packet bus support is not already installed, see ‘‘Add Packet Bus Support’’ on page 6-28 and perform the steps.