Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-13 Upgrade the Software and Hardware 4 Figure 4-1. TN794/TN2400 Network Controller Interface Assembly For high or critical reliability: 3. Insert the TN792 Duplication Interface circuit packs into the slots labeled DUPN INTFC. 4. If the R8si carrier is located in a Multicarrier Cabinet, attach the 14-in. fiber optic cable to the faceplates of the installed TN792 Duplication Interface circuit packs (see Figure 4-2 ). or If the R8si carrier is in a Single-Carrier Cabinet, then attach the 10-ft fiber optic cable to the faceplates of the installed TN792 Duplication Interface circuit packs using the fiber optic pass-thru kit. C A R D I N U S E ckdfjmp4 LJK 100198
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-14 Upgrade the Software and Hardware 4 Figure 4-2. Fiber optic cable connecting the two TN792 duplication interface circuit packs (multicarrier cabinet only) 5. Install apparatus blanks over any vacated slots. 6. Check the software load number on the TN790B Processor label. Insert the appropriate flashcard into the TN794/TN2400 assembly based on the following parameters: nIf the load number is the Release 8 load number, insert the new or original translation card as directed in the Save Translation step and Remove ISDN Interface Links step. nIf the load number is not the Release 8 load number, insert the orange-labeled software memory card. fodf792 KLC 090399 C A R D I N U S E ALARMS EMER TR C A R D I N U S E ALARMS EMER TRB AU TO A OVER IDES P ELucent EMER TR B AU TO A OVER ID E S P ELucent BA BA
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-15 Upgrade the Software and Hardware 4 Power Up the System (Standard Reliability) 1. Set the cabinet circuit breaker to ON. NOTE: If the system was rebooted with the software memory flashcard, switch flashcards when prompted. This takes about 3 minutes. 2. If applicable, remove the software memory flashcard and inser t the new or original translation flashcard as directed in the Save Translation step and Remove ISDN Interface Links step. Power Up the System (H/C Reliability) If powering up with translation cards inserted: 1. Verify that SPE select switches on the TN792 Duplication Interface circuit packs are on AUTO. 2. Set the cabinet circuit breaker to ON and wait for login prompt. If powering up with software memory flashcard inserted: 1. Set the SPE select switches to the control carrier that has software memory flashcard inserted. 2. Set the cabinet circuit breaker to ON. NOTE: Look for the “Card in Use” LED below the flashcard on the TN794 to go out. This takes about 3 minutes. 3. Remove software memory flashcard and insert the new or original translation flashcard into the same carrier as directed in the Save Translation step and Remove ISDN Interface Links step. 4. Insert the software memory flashcard into the other carrier. NOTE: Wa it for login: prompt. This takes about 3 minutes. 5. Power down the cabinet. 6. Set the SPE select switches to the control carrier with the software memory card inserted.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-16 Upgrade the Software and Hardware 4 7. Set the cabinet circuit breaker to ON NOTE: Look for the “Card in Use” LED below the flashcard on the TN794 to go out. This takes about 3 minutes. 8. Remove software memory flashcard and insert the new or original translation flashcard into the same carrier as directed in the Save Translation step and Remove ISDN Interface Links step. NOTE: Wa it for login: prompt. This takes about 3 minutes. 9. Set the SPE select switches to AUTO. Affix the Label 1. Affix the new TN790B processor circuit pack position label (designation strip) to the front of the cabinet. 2. Affix the new TN794/TN2400 network controller interface assembly circuit pack position label (designation strip) to the front of the cabinet. Administer the System 1. Log in as craft at the login: prompt. 2. Check for the Translation Corruption Detected message before proceeding with the upgrade. If corruption is detected, refer to ‘‘Translation Corruption Detected’’ in Appendix B, ‘‘Troubleshooting an Upgrade’’ to correct the problem. !CAUTION: Do not continue with the upgrade process until the translations errors are corrected. 3. Type status system 1 and press En te r to check the SPE Alarms field and verify that the Tone Clock is active. Set Daylight Savings Rules You can set up to 15 customized daylight savings time rules. A daylight savings time rule specifies the exact time when you want to transition to and from daylight savings time. It also specifies the increment at which to transition NOTE: The default daylight savings rule is 0, no daylight savings.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-17 Upgrade the Software and Hardware 4 1. Type change daylight-savings-rules and press En te r. 2. Type the appropriate start and stop information in the Change Day, Month, Date, Time, and Increment (for example, 1:00 equals one hour) fields for each rule. NOTE: You can change any rule except rule 0 (zero). You cannot delete a daylight savings rule if it is in use on either the Locations or Date and Time screens. 3. When done, press En t e r. Set Date and Time 1. Type set time and press En te r to bring up the Date and Time screen. Screen 4-1. Typical Date and Time Screen DAYLIGHT SAVINGS RULES Rule Change Day Month___Date Time____Increment 0: No Daylight Savings 1: Start: first Sunday ___ on or after April___ 1 at _2:00 01:00Stop: first Sunday___ on or after October_ 25 at _2:00 2: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 3: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 4: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 5: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 6: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 7: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ DATE AND TIME DATE Day of the Week: Tuesday Month: NovemberDay of the Month: 7 Year: 2000 TIME Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 1
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-18 Upgrade the Software and Hardware 4 2. Type the day in English (Sunday through Saturday) in the Day of the Week: field. See Table 4-3 for English day names. When done, press Ta b to move to next field. 3. Type the current month in English (January through December) in the Month: field. See Table 4-4 for English month names. When done, press Ta b to move to next field. 4. Type the day of month (1 through 31) in the Day of the Month: field and press Ta b to move to the next field. 5. Type the current year in the Year: field and press TA B to move to the next field. 6. Type the current hour for a 24-hour clock in the Hour: field and press Ta b to move to the next field. 7. Type the current minute (0 through 59) in the Minute: field (seconds cannot be set). When done, press Ta b to move to next field Table 4-3. English Day of the Week Names Day Number Day Name 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6Friday 7 Saturday Table 4-4. English Month Names Number Name Number Name 1 January 7 July 2 February 8 August 3 March 9 September 4 April 10 October 5 May 11 November 6 June 12 December
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-19 Upgrade the Software and Hardware 4 8. Type standard or daylight savings in the Type field, according to the current time in the local time zone. For example, if currently on standard time, type standard. 9. Type the rule number in the Daylight Savings Rule field. 10. When all the information is correct, press En te r. 11. Type display time and press En t e r to verify date and time data. Set Additional Administration For standard reliability: 1. Type list configuration software-version and press En t e r to verify the system software version (in the Memory Resident field). For high or critical reliability: 1. Type list configuration software-version long and press En t e r to verify the system software version (in the Memory Resident field) For all reliabilities: 2. Perform a sanity check on the system by executing the following commands to ensure the translations were read in properly: a. list station b. list trunk-group c. list hunt-group This ensures there is no translation corruption and the translations can be saved with the new software. 3. Notify the switch administrator that for any previous login names and passwords that still exist, the passwords expire in 24 hours. When changed, the new login names and passwords must conform to the following requirements: NOTE: As before, a login name must have 3 to 6 alphanumeric characters. A password must have 4 to 11 characters, including at least 1 alphabetic character and 1 numeric character. 4. Since an R1V3.0 G3-MA cannot notify users about expiring passwords, disable password aging for any login name used with an R1V3.0 G3-MA. NOTE: You must have init login and password to change any login information or to add a login.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-20 Upgrade the Software and Hardware 4 Enable TTI NOTE: Do this step only if the TTI is disabled and you want it enabled. 1. Type change system-parameters features and press En te r to change the TTI field back to its value before the upgrade. Resolve Alarms 1. Type display alarms and press En te r to examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Maintenance for R8si . Check Link Status 1. Type display communication-interface links and press En t e r. 2. Type status link number and press En t e r. Repeat this step for each link. Enable Scheduled Maintenance 1. Type change system-parameters maintenance and press En t e r to enable the scheduled daily maintenance. 2. Check the time fields. Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the regional Customer Software Administration to complete the steps in the shaded box. See ‘‘Where to Call for Technical Support’’ on page -xx for telephone numbers. NOTE: As part of the system registration process, the INADS Database Administrator enables Alarm Origination. 2. When administration is completed, log in as craft at the Login: prompt.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-21 Upgrade the Software and Hardware 4 Save Translations 1. Type save translation and press En t e r to copy upgraded translations in memory to the upgraded translation card, which takes about 10 minutes. Restore Announcements (if necessary) 1. Type restore announcements and press En t e r to copy announcements from the upgraded translation flashcard to memory, which takes about 40 minutes. Power Up DEFINITY LAN Gateway System 1. Log onto the DEFINITY LAN Gateway. 2. On the main menu, select Maintenance > Reset System > Reboot System. Power Up DEFINITY AUDIX System 1. To power up the AUDIX assembly, refer to ‘‘DEFINITY AUDIX Power Procedures’’ on page 1-26. init login administration: 1. Log in as init. 2. Type change system-parameters customer-options and press En t e r to verify that the customer options are properly set. 3. Go to screen 6, QSIG Optional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protocol b or d on an ISDN-PRI trunk group before the upgrade. 4. Type change system-parameters offer-options and press En t e r. 5. If the Activate Offer field is n, set it to y and press Ta b. A warning message lets you know whether you need to save translations and reboot to make the change permanent. 6. Press En te r to effect the changes or Canc el if there were no changes. 7. Contact the requester when done.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-22 Upgrade the Software and Hardware 4 Return Replaced Equipment 1. Return the replaced equipment to Lucent Technologies according to the requirements outlined in the following books: BCS/Material Logistics, MSL/Attended Stocking Locations Methods and Procedures for Basic Material Returns 2. If the original translation card is not being used with the Release 8 software, retain it for up to 10 business days to verify that the customer is satisfied and that there is no need to reverse the upgrade. 3. After 10 days, return the translation card to Lucent Technologies.