Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual
Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-13 Upgrade the Software and Hardware 3 Power Up the System (Standard Reliability) 1. Set the cabinet circuit breaker to ON. NOTE: If the system was rebooted with the software memory flashcard, you hear a beep from the SAT when you need to switch flashcards. This takes about 3 minutes. 2. If applicable, remove the software memory flashcard and inser t the new or original translation flashcard as directed in the Save Translation step and Remove ISDN Interface Links step. Power Up the System (H/C Reliability) If powering up with translation cards inserted: 1. Verify that SPE select switches on the TN792 Duplication Interface circuit packs are on AUTO. 2. Set the cabinet circuit breaker to ON and wait for login prompt. If powering up with software memory flashcard inserted: 1. Set the SPE select switches to the control carrier that has software memory flashcard inserted. 2. Set the cabinet circuit breaker to ON. NOTE: Look for the “Card in Use” LED below the flashcard on the TN794 to go out. This takes about 3 minutes. 3. Remove software memory flashcard and insert the new or original translation flashcard into the same carrier as directed in the Save Translation step and Remove ISDN Interface Links step. 4. Insert the software memory flashcard into the other carrier. NOTE: Wa it for login: prompt. This takes about 3 minutes. 5. Power down the cabinet. 6. Set the SPE select switches to the control carrier with the software memory card inserted.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-14 Upgrade the Software and Hardware 3 7. Set the cabinet circuit breaker to ON NOTE: Look for the “Card in Use” LED below the flashcard on the TN794 to go out. This takes about 3 minutes. 8. Remove software memory flashcard and insert the new or original translation flashcard into the same carrier as directed in the Save Translation step and Remove ISDN Interface Links step. NOTE: Wa it for login: prompt. This takes about 3 minutes. 9. Set the SPE select switches to AUTO. Affix the Label 1. Affix the new TN790B processor circuit pack position label (designation strip) to the front of the cabinet. 2. Affix the new TN794/TN2400 network controller interface assembly circuit pack position label (designation strip) to the front of the cabinet. Administer the System 1. Log in as craft at the login: prompt. 2. Check for the Translation Corruption Detected message before proceeding with the upgrade. If corruption is detected, refer to ‘‘Translation Corruption Detected’’ in Appendix B, ‘‘Troubleshooting an Upgrade’’ to correct the problem. !CAUTION: Do not continue with the upgrade process until the translations errors are corrected. 3. Type status system 1 and press En te r to check the SPE Alarms field and verify that the Tone Clock is active. Set Daylight Savings Rules You can set up to 15 customized daylight savings time rules. A daylight savings time rule specifies the exact time when you want to transition to and from daylight savings time. It also specifies the increment at which to transition NOTE: The default daylight savings rule is 0, no daylight savings.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-15 Upgrade the Software and Hardware 3 1. Type change daylight-savings-rules and press En te r. 2. Type the appropriate start and stop information in the Change Day, Month, Date, Time, and Increment (for example, 1:00 equals one hour) fields for each rule. NOTE: You can change any rule except rule 0 (zero). You cannot delete a daylight savings rule if it is in use on either the Locations or Date and Time screens. 3. When done, press En t e r. Set Date and Time 1. Type set time and press En te r to bring up the Date and Time screen. Screen 3-1. Typical Date and Time Screen DAYLIGHT SAVINGS RULES Rule Change Day Month___Date Time____Increment 0: No Daylight Savings 1: Start: first Sunday ___ on or after April___ 1 at _2:00 01:00Stop: first Sunday___ on or after October_ 25 at _2:00 2: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 3: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 4: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 5: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 6: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ 7: Start: first _________ on or after ________ __ at __:__ Stop: first _________ on or after ________ __ at __:__ DATE AND TIME DATE Day of the Week: Tuesday Month: NovemberDay of the Month: 7 Year: 2000 TIME Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 1
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-16 Upgrade the Software and Hardware 3 2. Type the day in English (Sunday through Saturday) in the Day of the Week: field. See Table 3-3 for English day names. When done, press Ta b to move to next field. 3. Type the current month in English (January through December) in the Month: field. See Table 3-4 for English month names. When done, press Ta b to move to next field. 4. Type the day of month (1 through 31) in the Day of the Month: field and press Ta b to move to the next field. 5. Type the current year in the Year: field and press TA B to move to the next field. 6. Type the current hour for a 24-hour clock in the Hour: field and press Ta b to move to the next field. 7. Type the current minute (0 through 59) in the Minute: field (seconds cannot be set). When done, press Ta b to move to next field Table 3-3. English Day of the Week Names Day Number Day Name 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6Friday 7 Saturday Table 3-4. English Month Names Number Name Number Name 1 January 7 July 2 February 8 August 3 March 9 September 4 April 10 October 5 May 11 November 6 June 12 December
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-17 Upgrade the Software and Hardware 3 8. Type standard or daylight savings in the Type field, according to the current time in the local time zone. For example, if currently on standard time, type standard. 9. Type the rule number in the Daylight Savings Rule field. 10. When all the information is correct, press En te r. 11. Type display time and press En t e r to verify date and time data. Set Additional Administration For standard reliability: 1. Type list configuration software-version and press En t e r to verify the system software version (in the Memory Resident field). For high or critical reliability: 1. Type list configuration software-version long and press En t e r to verify the system software version (in the Memory Resident field) For all reliabilities: 2. Perform a sanity check on the system by executing the following commands to ensure the translations were read in properly: a. list station b. list trunk-group c. list hunt-group This ensures there is no translation corruption and the translations can be saved with the new software. 3. Notify the switch administrator that for any previous login names and passwords that still exist, the passwords expire in 24 hours. When changed, the new login names and passwords must conform to the following requirements: As before, a login name must have 3 to 6 alphanumeric characters. A password must have 4 to 11 characters, including at least 1 alphabetic character and 1 numeric character. 4. Since an R1V3.0 G3-MA cannot notify users about expiring passwords, disable password aging for any login name used with an R1V3.0 G3-MA. Enable TTI NOTE: Do this step only if the TTI is disabled and you want it enabled. 1. Type change system-parameters features and press En te r to change the TTI field back to its value before the upgrade.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-18 Upgrade the Software and Hardware 3 Resolve Alarms 1. Type display alarms and press En te r to examine the alarm log. Resolve any alarms that may exist using DEFINITY Enterprise Communications Server Maintenance for R8si . Check Link Status 1. Type display communication-interface links and press En t e r. 2. Type status link number and press En t e r. Repeat this step for each link. Enable Scheduled Maintenance 1. Type change system-parameters maintenance and press En t e r to enable the scheduled daily maintenance. 2. Check the time fields. Enable Customer Options and Alarm Origination to INADS 1. Get the DOSS order number of the upgrade from the project manager and ask the regional Customer Software Administration to complete the steps in the shaded box. See ‘‘Where to Call for Technical Support’’ on page -xx for telephone numbers. NOTE: As part of the system registration process, the INADS Database Administrator enables Alarm Origination. 2. When administration is completed, log in as craft at the Login: prompt.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-19 Upgrade the Software and Hardware 3 Save Translations 1. Type save translation and press En t e r to copy upgraded translations in memory to the upgraded translation card, which takes about 10 minutes. Restore Announcements (if necessary) 1. Type restore announcements and press En t e r to copy announcements from the upgraded translation flashcard to memory, which takes about 40 minutes. Power Up DEFINITY LAN Gateway System 1. Log onto the DEFINITY LAN Gateway. 2. On the main menu, select Maintenance > Reset System > Reboot System. Power Up DEFINITY AUDIX System 1. To power up the AUDIX assembly, refer to ‘‘DEFINITY AUDIX Power Procedures’’ on page 1-26. init login administration: 1. Log in as init. 2. Type change system-parameters customer-options and press En t e r to verify that the customer options are properly set. 3. Go to screen 6, QSIG Optional Features, and set the Basic Call Setup field to y if the customer was using Supplementary Services Protocol b or d on an ISDN-PRI trunk group before the upgrade. 4. Type change system-parameters offer-options and press En t e r. 5. If the Activate Offer field is n, set it to y and press Ta b. A warning message lets you know whether you need to save translations and reboot to make the change permanent. 6. Press En te r to effect the changes or Canc el if there were no changes. 7. Contact the requester when done.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading G3s/si (w/Intel 386) to R8si 3-20 Upgrade the Software and Hardware 3 Return Replaced Equipment 1. Return the replaced equipment to Lucent Technologies according to the requirements outlined in the following books: BCS/Material Logistics, MSL/Attended Stocking Locations Methods and Procedures for Basic Material Returns 2. If the original translation card is not being used with the Release 8 software, retain it for up to 10 business days to verify that the customer is satisfied and that there is no need to reverse the upgrade. 3. After 10 days, return the translation card to Lucent Technologies.
Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-1 4 DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 4 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN This chapter provides the information necessary to upgrade the hardware and software from a DEFINITY ECS Release 5si or Release 6si system with a TN790/B processor to a Release 8si system. This includes the Survivable Remote EPN (SR EPN). You are replacing the following hardware: nThe TN790/B Processor with a new TN790B Processor, which contains the Release 8 software. nThe TN777B Network Control and TN778 Packet Control (if present) with the TN794/TN2400 Network Controller Interface Assembly nTN772 Duplication Interfaces with the TN792 Duplication Interfaces for high or critical reliability systems. The procedures step you through a software and hardware upgrade that can be done on either a standard reliability system or a high or critical reliability system. For more help refer to the following books: — DEFINITY Enterprise Communications Server Release 8 Administrator’s Guide — DEFINITY Enterprise Communications Server Release 8 Maintenance for R8si NOTE: Upgrading an SR EPN is similar to upgrading an R8si system. If you are upgrading an SR EPN: 1. Check the link status between the G3r PPN and the associated SR EPN. The link must be up and functioning before you can upgrade. If the system is in survive mode, resolve the alarms and return the link to service before proceeding with the upgrade.
DEFINITY ECS Release 8.2 Upgrades and Additions for R8.2si 555-233-122 Issue 1 April 2000 Upgrading R5si/R6si/R6 SR EPN to R8si/R8 SR EPN 4-2 Read this First 4 Read this First Service Interruption The upgrade process requires a service interruption of about 15 minutes. Closely coordinate the service interruption with the customer and the local account team. Call Management System (CMS) The CMS link is dropped and restarted during the upgrade. This causes CMS data to be lost. This data loss can be minimized if the upgrade is performed just after the last CMS measurement interval. All measurement data is lost during the upgrade (including BCMS). If needed, the repor ts may be printed before the upgrade begins. CMS could abort the processing of a call if a measured trunk that was par t of the conference dropped off the call before the end of the call. Customers experiencing this symptom and who are running R3V4 CMS should update to r3v4ao.e or higher. Contact Network Technicians Contact the technician for each public and private network before the upgrade begins. Otherwise, it is possible that network access trunk facilities will be busied out at the far end. Translation Card Compatibility An upgrade from a G3V4 requires a Release 8 formatted translation card. A MIPS formatted translation card ships with each upgrade. Usable Circuit Packs Every circuit pack used in the Release 8 system must conform to the minimum usable vintage requirements for that system. At a presale site inspection, the remediation process checks the vintages of existing circuit packs to be reused in the Release 8 system. Replace all unusable vintage circuit packs with current vintages. Refer to Te c h n i c a l Q u a r t e r l y, Reference Guide for Circuit Pack Vintages, Change Notices, and to the Software Release Letter for information about usable circuit pack vintages. For information about usable vintages of non-U.S. circuit packs, refer to the ITAC Technical Alert from your regional distributor.