Comdial Impact Dsu Instructions Manual
Have a look at the manual Comdial Impact Dsu Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 133 Comdial manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
MUTE SHIFT SPEAKERINTERCOM TRNS/CNF TAP HOLD OPER TUV PRS WXYDEF ABC QZ MN O JKL GHI 0 879 321 # 6 54 DIGITECH COMDIAL SPKRTAP TRANS CONF MUTE HOLD ITCM LCD Alphanumeric DisplayInteractive Buttons (NOT Programmable) Speaker Handset TA P Button Transfer/ Conference Button Message Waiting Light Hold Button Intercom ButtonMicrophone Opening Speaker Button Mute Button Shift Button Volume Control Keypad Progammable Buttons Auxiliary Jack (On bottom) TA P Button Transfer/ Conference Button Speaker Mute Button Speaker Button Volume Control Message Waiting Light Hold ButtonMicrophone Opening Intercom Button Programmable Buttons Interactive Buttons (NOT Programmable) LCD Alphanumeric Display CAJS107 Figure 1–9: Station Controls And Indicators OnImpactAnd DigiTech Telephones IMI66–107Digital Telephone System Introducing The DSU 1 – 17
cajs110 LCD Display Interactive Buttons Speaker Mute Button T/C Button SPKR Button Message Waiting Light Hold Button TAP Button ITCM ButtonFeature Buttons, Line Buttons, and DSS Buttons Volume Control Microphone Opening 1 2 4 7 0 89 56 3 # ABC GHI PRS OPERTUVWXY JKLMNO DEF SPKR HOLD TAPITCM T/C MUTE Figure 1–10:Station Controls And Indicators OnImpression Telephones Digital Telephone SystemIMI66–107 1 – 18 Introducing The DSU
1.7 General Specifications System Capacity G0408 G0816 G1632 GM408 Lines 4 8 16 4 Stations 8 16 32 8 DSS/BLF Consoles Two Per Station (One Per Station Port)Two Per Station (One Per Station Port)Two Per Station (One Per Station Port)Two Per Station (One Per Station Port) Intercom Paths Non-blocking Non-blocking Non-blocking Non-blocking Maximum Simultaneous Intercom ConversationsNon-blocking Non-blocking Non-blocking Non-blocking Paging Ports1 1 1 Not Applicable Park Orbits9 9 9 Not Applicable System Speed Dials 99 99 99 Not Applicable Station Speed Dials 10 10 10 Not Applicable Autodials Unused Buttons Unused Buttons Unused Buttons Not Applicable Power Fail Circuits1111 Common Equipment Dimensions G0408 G0816 G1632 GM408 Width (inches) 16.5 16.5 16.5 16.5 Height (inches) 21.3 27.1 27.6 9.25 Depth (inches) 3.8 3.8 4.5 1.75 Weight (pounds) 17.5 26 30.5 4 Station Dimensions DigiTech+ Multiline Single-Line Proprietary Footprint (inches) 8.625 X 7.658 6.5 X 8.5 Weight (pounds) 2.5 1.9 Impact+ 12-line 24-line Single-Line Proprietary Footprint (inches) 9.08 X 8.9 10.75 X 8.9 8.9 X 7.13 Weight (pounds) 2.3 2.6 1.75 IMI66–107Digital Telephone System Introducing The DSU 1 – 19
Conferencing Maximum Combinations at Any One Time G0408 and G0816 G1632 1 five-way plus 1 three-way plus 2 SOHVA 4 five-way plus 1 three-way plus 1 SOHVA 2 four-way plus 2 SOHVA 6 four-way plus 2 three-way 1 four-way plus 3 three-way 3 four-way plus 9 three-way 5 three-way plus 1 SOHVA 16 three-way SMDA Storage Capacity G0408 G0816 G1632 800 1600 1600 Station Cable Requirements Type2-wire (1-pair) twisted, non-shielded cable Maximum Length1000 feet with 24 gauge wire, 2000 feet with 22 gauge wire Switching PrincipleDigital, time division multiplexing (TDM). Provides non-blocking switching with stored program control. Operating Environment Temperature32-122 degrees F (0-50 degrees C) Humidity90 percent relative, non-condensing Power Requirements G0408 G0816 G1632 GM408 Voltage90-129 VAC Single phase all models Current0.6A 2.0 A 2.1A Not Applicable Power70W 135W 150W Not Applicable Volt/Amps80VA 190VA 200VA Not Applicable Terminations StationStandard 50-pin male connectors for connection to external distribution field LineStandard 6-conductor mini-jack (USOC 14C) Digital Telephone SystemIMI66–107 1 – 20 Introducing The DSU
Music Interface Input Level3 Volts peak-to-peak maximum Input Impedance Approximately 500 Ohms Connector RCA phono jack Station Message Detail Recording Port FormatSerial, pseudo RS-232C ParityNone Data Bits7 or 8 (programmable) Stop Bits1 or 2 (programmable) Baud RateProgrammable in class of service HandshakingX on -X off Hardware -CTS Cable Length500 feet maximum PA Port Output Level400 Millivolts peak-to-peak (typical speech) Output ImpedanceApproximately 500 Ohms ConnectorRCA phono jack Central Office Limits Loop Limits1900 Ohms maximum loop Cable Insulation Leakage15,000 Ohms minimum Industry/Regulatory Standards FCC Certified, part 15 (Class A) FCC Registered (fully protected) LISTED by OSHA-accredited, nationally recognized, test laboratory EIA RS478 Bell publication 48002 guidance Hearing aid compatible handset Memory Retention After Power Loss60 hours minimum Ringer Equivalence Number1.3B IMI66–107Digital Telephone System Introducing The DSU 1 – 21
1.7.1 Feature Codes Feature Dialing Code All Call Page (Through Station Speakers) INTERCOM, 87 Attendant Calling INTERCOM, 0 Automatic Redialing Programmed Button Background Music On INTERCOM,S1 Off INTERCOM, # 1 Automatic Call Back Activate INTERCOM, (ext no),S6 Cancel INTERCOM, # 6 Station-to-Station MessagingActivate INTERCOM, (ext no),S7 Cancel INTERCOM, # 7, (ext no) LCD Messaging Set INTERCOM,S02 (10) Cancel INTERCOM, # 02 Call Forward Personal INTERCOM,S05, (ext no) Cancel INTERCOM, # 05 All Calls INTERCOM,S5, (ext no) Cancel INTERCOM, # 5 Call Park Park Orbits 19 INTERCOM,S(9199) Pick Up INTERCOM, # (9199) Call Pick Up Directed INTERCOM,S4, (ext no) Group INTERCOM, # 4 Call Waiting Tone Send INTERCOM, (ext no),S01 Cancel Hang Up Do Not Disturb Set Programmed Button Cancel Programmed Button Executive Override INTERCOM, (ext no),S03 External Page INTERCOM, 89 Handsfree Answer Inhibit Set MUTE Cancel MUTE Hold Manual HOLD Exclusive HOLD, HOLD Direct INTERCOM,S90, (ext no) Direct Hold Pick UpINTERCOM, # 90 Line Answer From Any Station INTERCOM, 80 Line Group Access Group 1 INTERCOM, 9 Group 2 INTERCOM, 81 Group 3 INTERCOM, 82 Group 4 INTERCOM, 83 Line Queuing Enable Line Group INTERCOM, (gp code),S8 Cancel INTERCOM, # 8 Meet Me Answer Paging INTERCOM, 88 Message Waiting Set INTERCOM,S3, (ext no) Cancel From Idle INTERCOM, # 3, (ext no) Digital Telephone SystemIMI66–107 1 – 22 Introducing The DSU
Cancel On Line INTERCOM, Retrieve Message INTERCOM, HOLD Night Transfer (Attendant) On INTERCOM, S # 03, Programmed Button Off INTERCOM,S# 03, Programmed Button Personal Ringing Tones Set Tones 16 INTERCOM,S S4 (16) Pulse/Tone Switching # Redial Last Dialed Number # Save Number Redial Use HOLD, Programmed Button Store Programmed Button Service Observing INTERCOM, # 03, (ext no) Speed Dial Station 09 SystemS0199 TAP (on line) Activate INTERCOM, #04 Toll Restriction Override Activate INTERCOM,SS6 (extension number, code) Tracker Pager Enable INTERCOM,S06 Disable INTERCOM, #06 Send Message INTERCOM, #01 Voice Announce Block Block INTERCOM,S2 Unblock INTERCOM, # 2 Zone Page Zone 1 INTERCOM, 84 Zone 2 INTERCOM, 85 Zone 3 INTERCOM, 86 IMI66–107Digital Telephone System Introducing The DSU 1 – 23
1.7.2 System Ringing Patterns Ring TypeRing Cadence CO/PBX Line Ring Host system ring cadence Intercom Tone Signaling Two 150 msec. tone bursts every four seconds Voice Signaling alert One 215 msec. tone burst Timed hold recall at station that put call on hold Three 150 msec. tone bursts at the end of each timeout period Call back alert One 80 msec. tone burst followed by three 150 msec. tone bursts and one 80 msec. tone burst Queue Enabled ^ Call forward alert One 80 msec. tone burst Transfer ringing Two 1.1 sec tone busts every four seconds Tone TypeTone Cadence Dial Tone Continuous on Called station ring-back One sec. on and three sec. off Base level program entry 80 msec. tone burst sounded once Error toneincorrect entry 530 msec. tone burst sounded three times All-call and zone paging notification tone 80 msec. tone burst followed by 280 msec. tone Busy tone 530 msec. tones sounded continuously Override feature not allowed ^ Night transfer feature not allowed ^ Call waiting tone Three 80 msec. tone bursts sounded once Called station in do-not-disturb mode140 msec. tone burst sounded twice every 1.5 sec. Call-back busy feature on 260 msec. tone burst sounded once System is awaiting memory dial number or key mapping entry after location is specified80 msec. tone burst sounded continuously Override feature on warning tone Six 100 msec. tone bursts sounded for 1.5 secs. SOHVA tone ^ DISD ringback tone Dual 440/480 Hz tone sounded 1 sec. on/1 sec. off DISD dial tone 381 Hz tone sounded continuously DISD confirmation tone Two 125 sec. bursts of 381 Hz tone sounded once DISD busy/error tone Three 500 msec. bursts of 381 Hz tone sounded once Digital Telephone SystemIMI66–107 1 – 24 Introducing The DSU
1.8 Seeking Repair Assistance If your common equipment cabinet or individual stations need repair, you may return the equipment to Comdial. Comdial will, at its option, either repair or replace it. There is a fixed charge for this repair. For information on this charge, call or write to the address given below. Comdial P.O. Box 7266 Charlottesville VA 22906 Attn: Repair Department Telephone: (804) 978-2400 1-800-877-4448 If you do return equipment for repair, pack it carefully to prevent damage. Any damages during shipment are your responsibility. You should ship the equipment freight or postage prepaid. IMI66–107Digital Telephone System Introducing The DSU 1 – 25