    Have a look at the manual Cisco Systems Active Voice Repartee Unity R2 4 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 Cisco Systems manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							APPPENDIX A: Voice and fax boards143
    Hardware settings
    Do the following procedure as you install fax boards.
    WARNING!Do not remove the cover from the server or expansion 
    chassis while the power is on, if a CPD/220 fax board is already 
    installed. The voltage level from the board can cause injury.
    WARNING!Never connect a loop-start phone line to a DID fax 
    port. The voltage in the loop-start line will damage the fax board. If 
    you are unsure whether the line is a loop-start line, test it with a 
    volt meter to confirm that there is no voltage.
    To  s e t  s w i t c h  b l o c k  S W 1
    The switch block SW1 settings determine the fax ports’ I/O 
    addresses. 
    The CPD/220 board contains four fax ports. Depending on the 
    configuration of the Unity server, you can install up to two 
    CPD/220 boards.
    Set the SW1 switches on each board as shown below.
    LED status indicators
    There are two LED status indicators for each fax port. The fol-
    lowing table describes the meaning of the status indicators.
    SW1
    First board
    Ports 0–3
    Second board
    Ports 4–7
    Color Lit Unlit Blinking
    Green Port is off hook Port is on hook ---
    Amber Board is 
    operationalBoard is not 
    operationalBoard configuration 
    problem
    123456
    On
    Off
    123456
    On
    Off 
    						
    							UNITY INSTALLATION GUIDE144
    Dialogic 
    GammaLink 
    CPi/200 
    fax boardLED status indicators
    Fax board backplate
    Pin 3: First fax line tip Pin 2: First fax line ring
    Connection pinouts
    The CPi/200 uses an 
    RJ-14 connector.
    Lines 1 & 2
    Pin 1: Second fax line tip
    Pin 4: Second fax line ring
    Switch block SW1Side view 
    						
    							APPPENDIX A: Voice and fax boards145
    Hardware settings
    Do the following procedure as you install fax boards.
    To  s e t  s w i t c h  b l o c k  S W 1
    The switch block SW1 settings determine the fax ports’ I/O 
    addresses.
    The CPi/200 board contains two fax ports. Depending on the 
    configuration of the Unity server, you can install up to two 
    CPi/200 boards.
    Set the SW1 switches on each board as shown below.
    LED status indicators
    There are two LED status indicators for each fax port. The fol-
    lowing table describes the meaning of the status indicators.
    SW1
    First board
    Ports 0–1
    First board
    Ports 4–5
    Color Lit Unlit Blinking
    Green Port is off hook Port is on hook ---
    Amber Board is 
    operationalBoard is not 
    operationalBoard configuration 
    problem
    On
    Off
    123
    On
    Off
    123 
    						
    							UNITY INSTALLATION GUIDE146
    Dialogic 
    GammaLink 
    CPi/200 PCI 
    fax board
    LED status indicators
    Fax board backplate
    Pin 3: First fax line tip Pin 2: First fax line ring
    Connection pinouts
    The CPi/200 PCI uses 
    an RJ-11 connector.
    Lines 1 & 2
    Pin 1: Second fax line tip
    Pin 4: Second fax line ringRotary switch
    Side view To p  v i e w 
    						
    							APPPENDIX A: Voice and fax boards147
    Hardware settings
    Do the following procedure as you install fax boards.
    To set the rotary switch
    The rotary switch setting identifies the fax board and specifies 
    which fax ports are on which board. 
    The CPi/200 PCI board contains two fax ports. Depending on the 
    configuration of the Unity server, you can install up to four 
    CPi/200 PCI boards.
    Set the rotary switch on each board as shown below.
    LED status indicators 
    There are two LED status indicators for each fax port. The fol-
    lowing table describes the meaning of the status indicators.
    Switch
    First board
    Second board
    Third board
    Fourth board
    Color Lit Unlit Blinking
    Green Port is off hook Port is on hook ---
    Amber Board is 
    operationalBoard is not 
    operationalBoard configuration 
    problem
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF 
    						
    							UNITY INSTALLATION GUIDE148
    Dialogic 
    GammaLink 
    CPi/400 PCI 
    fax board
    LED status indicators
    Pin 3: First fax line tip Pin 2: First fax line ring
    Connection pinouts
    The CPi/400 PCI uses 
    RJ-11 connectors.
    Pin 1: Second fax line tip
    Pin 4: Second fax line ringRotar y switch
    Pin 3: Third fax line tip Pin 2: Third fax line ring
    Pin 1: Fourth fax line tip
    Pin 4: Fourth fax line ring
    Fax board backplate
    Lines 3 & 4
    Lines 1 & 2
    Side view To p  v i e w 
    						
    							APPPENDIX A: Voice and fax boards149
    Hardware settings
    Do the following procedure as you install fax boards.
    To set the rotary switch
    The rotary switch setting identifies the fax board and specifies 
    which fax ports are on which board. 
    The CPi/400 PCI board contains four fax ports. Depending on 
    the configuration of the Unity server, you can install up to eight 
    CPi/400 PCI boards.
    Set the rotary switch on each board as shown below.
    LED status indicators
    There are two LED status indicators for each fax port. The fol-
    lowing table describes the meaning of the status indicators.
    Switch Switch
    First board Fourth board
    Second board Fifth board
    Third board Sixth board
    Color Lit Unlit Blinking
    Green Port is off hook Port is on hook ---
    Amber Board is 
    operationalBoard is not 
    operationalBoard configuration 
    problem
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF
    4
    08
    C
    675
    9AB
    123
    DEF 
    						
    							UNITY INSTALLATION GUIDE150
    Natural 
    MicroSystems 
    AG 2000 
    voice and fax 
    boardSwitch SW1H.100 bus connector
    Voice boar d b ac kp la te
    Lines 1 & 2
    Lines 3 & 4
    Lines 7 & 8
    Pin 1: Not used
    Pin 2: Tip 2
    Pin 3: Ring 1
    Pin 4: Tip 1
    Pin 5: Ring 2
    Pin 6: Not used
    Connection pinouts
    The AG 2000 uses 
    RJ-14 connectors.
    Lines 5 & 6
    Side view 
    						
    							APPPENDIX A: Voice and fax boards151
    Using AG 2000 boards
    AG 2000 boards can be used for both voice and fax ports. 
    The number of ports that are dedicated to fax is determined by 
    the Unity system key. If you want more or fewer fax ports, you 
    must upgrade the system key. For more information, see “Sys-
    tem key upgrades,” on page 112.
    A fax port can only send and receive faxes. It cannot answer 
    voice calls.
    If the AG 2000 boards are used for both voice and fax, voice 
    ports are assigned first, beginning with the first port on the first 
    board. Fax ports are then assigned, beginning with the next 
    available port. The AG 2000 does not include a setting to desig-
    nate board sequence, so you need to perform single-line tests to 
    determine which ports are voice ports and which are fax ports. If 
    Unity answers the call, the port is a voice port. If you hear the 
    fax tone, the port is a fax port.
    Continued 
    						
    							UNITY INSTALLATION GUIDE152
    Natural 
    MicroSystems 
    AG 2000 
    Continued
    voice and fax boardHardware settings
    Do the following procedure as you install voice boards.
    To set the DIP switch that controls H.100 bus 
    termination
    The setting on the DIP switch on the AG 2000 board depends on 
    how many boards you are installing:
    One board  Set all switches to “Off.”
    Two boar ds  Set all switches on both boards to “On.”
    Three or more boards  Set all switches on the first and last 
    boards to “On,” and set all switches on the middle boards to 
    “Off.”
    Number of boards Setting
    One
    Two Both boards
    Three or more First and last boards
    All other boards
    123456
    On
    Off
    78
    123456
    On
    Off
    78
    123456
    On
    Off
    78
    123456
    On
    Off
    78 
    						
    All Cisco Systems manuals Comments (0)