Have a look at the manual Cisco Systems Active Voice Repartee Unity R2 4 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 Cisco Systems manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
APPPENDIX A: Voice and fax boards123 Software settings During Unity Setup, do the following procedure when the Dia- logic D/SC Configuration dialog box appears. To enter Dialogic settings during Unity Setup aChange the value of “BLTInterrupt” to “5.” bChange the value of “BLTAddress” to the appropriate value: Turnkey systemSelect “D0000.” Component systemSelect the address that you reserved during the procedure “To find and reserve memory addresses and an IRQ (ISA boards in a component system only),” on page 35. cClick “OK” to continue. dReturn to the procedure that you were doing when the Dia- logic D/SC Configuration dialog box appeared.
UNITY INSTALLATION GUIDE124 Dialogic D/41ESC-Euro voice board 0 Voice board backplate SC bus connector Switch SW1 Switch block SW2 To p v i e w Side view Pin 4: Unused Connection pinouts The D/41ESC-Euro uses RJ-11 connectors. Line 1 Line 2 Line 3 Line 4 Pin 1: Unused Pin 2: Tip Pin 3: Ring
APPPENDIX A: Voice and fax boards125 Hardware settings Do the following procedures as you install voice boards. To s e t t h e S W 1 s w i t c h For each Dialogic ISA voice board that has a rotary switch, set the rotary switch to a unique value starting with 0 and continuing in sequence. For example, set the rotary switch on the first three ISA voice boards in the Unity server as shown below. This is also the order in which you install the boards in the server. To s e t s w i t c h b l o c k S W 2 Set SW2 switches to “Off” on all boards. Software settings During Unity Setup, do the following procedures when the Dia- logic D/SC Configuration dialog box appears. To enter Dialogic settings during Unity Setup aChange the value of “BLTInterrupt” to “5.” bChange the value of “BLTAddress” to the appropriate value: Turnkey systemSelect “D0000.” Component systemSelect the address that you reserved during the procedure “To find and reserve memory addresses and an IRQ (ISA boards in a component system only),” on page 35. cDo not click “OK” to continue. Instead, continue with the next procedure. Continued First ISA board Second ISA board Third ISA board 0 1 2
UNITY INSTALLATION GUIDE126 Dialogic D/41ESC-Euro Continued voice board To set the parameter file for the D/41ESC-Euro board aOn the Windows Start menu, click Programs > Dialogic Sys- tem Software > Dialogic Configuration Manager–DCM. The tree-structured list contains an entry for each Dialogic board installed in the server. Note that the D/41ESC-Euro board is displayed in the list as “D/41ESC.” bDouble-click the first occurrence of “D/41ESC” in the tree list. The Properties dialog box for the board appears. cClick the Country tab. dChange the value of “Country” to “Euro (CTR-21).” eClick “OK.” fTo set additional D/41ESC-Euro boards, double-click the next occurrence of “D/41ESC” in the list and repeat steps cthroughe. gClose the DCM. hIn the Dialogic D/SC Configuration dialog box, click “OK” to continue with Unity setup. iReturn to the procedure that you were doing when the Dia- logic D/SC Configuration dialog box appeared.
APPPENDIX A: Voice and fax boards127 Dialogic D/120JCT-LS voice board Continued Vo i c e b oa r d b a c k p l a t e Connection pinouts The D/120JCT-LS uses RJ-25 connectors. Lines 1 and 2 Lines 3 and 4 Lines 5 and 6 Lines 7 and 8 Pin 6: Ear th recall 2 Pin 5: Ring 2 Pin 4: Tip 1 Pin 3: Ring 1 Pin 2: Tip 2 Pin 1: Ear th recall 1Switch SW100 Switch SW1 Side view To p v i e w Lines 9 and 10 Lines 11 and 12 CT bus connector
UNITY INSTALLATION GUIDE128 Dialogic D/120JCT-LS voice Continued boardHardware settingsDo the following procedures as you install voice boards. To set the SW100 switch For each Dialogic PCI voice board that has a rotary switch, set the rotary switch to a unique value starting with 1 and continuing in sequence. For example, set the rotary switch on the first three PCI voice boards in the Unity server as shown below. This is also the order in which you install the boards in the server. To s e t t h e S W 1 s w i t c h Set switch SW1 to “On hook” on all boards as shown below. Software settings None. First PCI board Second PCI board Third PCI board1 2 3 On hook
APPPENDIX A: Voice and fax boards129 Dialogic D/160SC voice board Continued SC bus connector Side view To p v i e w Switch SW 100
UNITY INSTALLATION GUIDE130 Dialogic D/160SC Continued voice board Use the Dialogic D/160SC voice board with the VTG VoiceBridge 2000 feature-set board to provide feature-set integration on Mitel SX-200 and SX-2000 phone systems. All of the D/160SC and VoiceBridge 2000 boards that you are installing must be in the same box because they all must be con- nected with an SC bus cable. If there are not enough slots in the Unity server, then you must put all of the boards into an expan- sion chassis. Hardware settings Do the following procedures as you install voice boards. The IRQ for Dialogic D/160SC boards is 2 on all Unity turnkey systems except the Dell 2400. On the Dell 2400, the IRQ for D/160SC boards is 5. To set the SW100 switch For each Dialogic ISA voice board that has a rotary switch, set the rotary switch to a unique value starting with 0 and continuing in sequence. For example, set the rotary switch on the first three ISA voice boards in the Unity server as shown below. This is also the order in which you install the boards in the server. First ISA board Second ISA board Third ISA board0 1 2
APPPENDIX A: Voice and fax boards131 Software settings During Unity Setup, the Dialogic D/SC Configuration dialog box appears. Do the following procedure after you have done the pro- cedure “To enter VoiceBridge 2000 settings during Unity Setup,” on page 161. To enter Dialogic settings during Unity Setup aChange the value of “BLTInterrupt” to the appropriate value: All turnkey systems, except Dell 2400Select “2.” Dell 2400 turnkey systemSelect “5.” Component systemSelect the IRQ that you reserved dur- ing the procedure “To find and reserve memory addresses and an IRQ (ISA boards in a component system only),” on page 35. bChange the value of “BLTAddress” to the appropriate value: Turnkey systemSelect “D0000.” Component systemSelect the address that you reserved during the procedure “To find and reserve memory addresses and an IRQ (ISA boards in a component system only),” on page 35. cClick “OK” to continue. dReturn to the procedure that you were doing when the Dia- logic D/SC Configuration dialog box appeared.
UNITY INSTALLATION GUIDE132 Dialogic D/160SC-LS voice boardSC bus connectorSwitch SW100Switch SW600 DB-37 connector To p v i e w Side view Connection pinouts The D/160SC-LS uses a DB-37 connector. See the table on the next page for pinout information. Pin 1 Pin 20