    Have a look at the manual Cisco Systems Active Voice Repartee Unity R2 4 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 Cisco Systems manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							APPPENDIX A: Voice and fax boards123
    Software settings
    During Unity Setup, do the following procedure when the Dia-
    logic D/SC Configuration dialog box appears.
    To enter Dialogic settings during Unity Setup
    aChange the value of “BLTInterrupt” to “5.”
    bChange the value of “BLTAddress” to the appropriate value:
    Turnkey systemSelect “D0000.”
    Component systemSelect the address that you reserved 
    during the procedure “To find and reserve memory 
    addresses and an IRQ (ISA boards in a component system 
    only),” on page 35.
    cClick “OK” to continue.
    dReturn to the procedure that you were doing when the Dia-
    logic D/SC Configuration dialog box appeared. 
    						
    							UNITY INSTALLATION GUIDE124
    Dialogic 
    D/41ESC-Euro 
    voice board
    0
    Voice board backplate
    SC bus connector Switch SW1 Switch block SW2
    To p  v i e w
    Side view
    Pin 4: Unused
    Connection pinouts
    The D/41ESC-Euro uses 
    RJ-11 connectors.
    Line 1
    Line 2
    Line 3
    Line 4
    Pin 1: Unused
    Pin 2: Tip
    Pin 3: Ring 
    						
    							APPPENDIX A: Voice and fax boards125
    Hardware settings
    Do the following procedures as you install voice boards.
    To  s e t  t h e  S W 1  s w i t c h
    For each Dialogic ISA voice board that has a rotary switch, 
    set the rotary switch to a unique value starting with 0 and 
    continuing in sequence.
    For example, set the rotary switch on the first three ISA 
    voice boards in the Unity server as shown below. This is also 
    the order in which you install the boards in the server.
    To  s e t  s w i t c h  b l o c k  S W 2
    Set SW2 switches to “Off” on all boards.
    Software settings
    During Unity Setup, do the following procedures when the Dia-
    logic D/SC Configuration dialog box appears.
    To enter Dialogic settings during Unity Setup
    aChange the value of “BLTInterrupt” to “5.”
    bChange the value of “BLTAddress” to the appropriate value:
    Turnkey systemSelect “D0000.”
    Component systemSelect the address that you reserved 
    during the procedure “To find and reserve memory 
    addresses and an IRQ (ISA boards in a component system 
    only),” on page 35.
    cDo not click “OK” to continue. Instead, continue with the 
    next procedure.
    Continued First ISA board
    Second ISA board
    Third ISA board
    0
    1
    2 
    						
    							UNITY INSTALLATION GUIDE126
    Dialogic 
    D/41ESC-Euro 
    Continued
    voice board
    To set the parameter file for the D/41ESC-Euro board
    aOn the Windows Start menu, click Programs > Dialogic Sys-
    tem Software > Dialogic Configuration Manager–DCM.
    The tree-structured list contains an entry for each Dialogic 
    board installed in the server. Note that the D/41ESC-Euro 
    board is displayed in the list as “D/41ESC.”
    bDouble-click the first occurrence of “D/41ESC” in the tree 
    list. The Properties dialog box for the board appears.
    cClick the Country tab.
    dChange the value of “Country” to “Euro (CTR-21).”
    eClick “OK.”
    fTo set additional D/41ESC-Euro boards, double-click the 
    next occurrence of “D/41ESC” in the list and repeat steps 
    cthroughe.
    gClose the DCM.
    hIn the Dialogic D/SC Configuration dialog box, click “OK” to 
    continue with Unity setup.
    iReturn to the procedure that you were doing when the Dia-
    logic D/SC Configuration dialog box appeared. 
    						
    							APPPENDIX A: Voice and fax boards127
    Dialogic 
    D/120JCT-LS 
    voice board
    Continued
    Vo i c e  b oa r d  b a c k p l a t e Connection pinouts
    The D/120JCT-LS uses 
    RJ-25 connectors.
    Lines 1 and 2
    Lines 3 and 4
    Lines 5 and 6
    Lines 7 and 8
    Pin 6: Ear th recall 2
    Pin 5: Ring 2
    Pin 4: Tip 1
    Pin 3: Ring 1
    Pin 2: Tip 2
    Pin 1: Ear th recall 1Switch SW100 Switch SW1
    Side view To p  v i e w
    Lines 9 and 10
    Lines 11 and 12 CT bus connector 
    						
    							UNITY INSTALLATION GUIDE128
    Dialogic 
    D/120JCT-LS voice 
    Continued
    boardHardware settingsDo the following procedures as you install voice boards.
    To set the SW100 switch
    For each Dialogic PCI voice board that has a rotary switch, 
    set the rotary switch to a unique value starting with 1 and 
    continuing in sequence. 
    For example, set the rotary switch on the first three PCI 
    voice boards in the Unity server as shown below. This is also 
    the order in which you install the boards in the server. 
    To  s e t  t h e  S W 1  s w i t c h
    Set switch SW1 to “On hook” on all boards as shown below.
    Software settings
    None.
    First PCI board
    Second PCI board
    Third PCI board1
    2
    3
    On hook 
    						
    							APPPENDIX A: Voice and fax boards129
    Dialogic 
    D/160SC 
    voice board
    Continued
    SC bus connector
    Side view To p  v i e w
    Switch SW 100 
    						
    							UNITY INSTALLATION GUIDE130
    Dialogic D/160SC 
    Continued
    voice board
    Use the Dialogic D/160SC voice board with the VTG VoiceBridge 
    2000 feature-set board to provide feature-set integration on 
    Mitel SX-200 and SX-2000 phone systems.
    All of the D/160SC and VoiceBridge 2000 boards that you are 
    installing must be in the same box because they all must be con-
    nected with an SC bus cable. If there are not enough slots in the 
    Unity server, then you must put all of the boards into an expan-
    sion chassis.
    Hardware settings
    Do the following procedures as you install voice boards.
    The IRQ for Dialogic D/160SC boards is 2 on all Unity turnkey 
    systems except the Dell 2400. On the Dell 2400, the IRQ for 
    D/160SC boards is 5.
    To set the SW100 switch
    For each Dialogic ISA voice board that has a rotary switch, 
    set the rotary switch to a unique value starting with 0 and 
    continuing in sequence. 
    For example, set the rotary switch on the first three ISA 
    voice boards in the Unity server as shown below. This is also 
    the order in which you install the boards in the server. 
    First ISA board
    Second ISA board
    Third ISA board0
    1
    2 
    						
    							APPPENDIX A: Voice and fax boards131
    Software settings
    During Unity Setup, the Dialogic D/SC Configuration dialog box 
    appears. Do the following procedure after you have done the pro-
    cedure “To enter VoiceBridge 2000 settings during Unity Setup,” 
    on page 161.
    To enter Dialogic settings during Unity Setup
    aChange the value of “BLTInterrupt” to the appropriate value:
    All turnkey systems, except Dell 2400Select “2.”
    Dell 2400 turnkey systemSelect “5.”
    Component systemSelect the IRQ that you reserved dur-
    ing the procedure “To find and reserve memory addresses 
    and an IRQ (ISA boards in a component system only),” on 
    page 35.
    bChange the value of “BLTAddress” to the appropriate value:
    Turnkey systemSelect “D0000.”
    Component systemSelect the address that you reserved 
    during the procedure “To find and reserve memory 
    addresses and an IRQ (ISA boards in a component system 
    only),” on page 35.
    cClick “OK” to continue.
    dReturn to the procedure that you were doing when the Dia-
    logic D/SC Configuration dialog box appeared. 
    						
    							UNITY INSTALLATION GUIDE132
    Dialogic 
    D/160SC-LS 
    voice boardSC bus
    connectorSwitch
    SW100Switch 
    SW600
    DB-37 connector
    To p  v i e w
    Side view
    Connection pinouts
    The D/160SC-LS uses a DB-37 
    connector. See the table on the 
    next page for pinout information.
    Pin 1
    Pin 20 
    						