Have a look at the manual Cisco Systems Active Voice Repartee Unity R2 4 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 Cisco Systems manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
APPPENDIX A: Voice and fax boards133 DB-37 pinouts Pin 37 is the ground. Pins 17, 34, 35, and 36 are unused. Continued Line number Tip connection Ring connection 1 Pin 1 Pin 18 2 Pin 2 Pin 19 3 Pin 3 Pin 20 4 Pin 4 Pin 21 5 Pin 5 Pin 22 6 Pin 6 Pin 23 7 Pin 7 Pin 24 8 Pin 8 Pin 25 9 Pin 9 Pin 26 10 Pin 10 Pin 27 11 Pin 11 Pin 28 12 Pin 12 Pin 29 13 Pin 13 Pin 30 14 Pin 14 Pin 31 15 Pin 15 Pin 32 16 Pin 16 Pin 33
UNITY INSTALLATION GUIDE134 Dialogic D/160SC-LS Continued voice boardHardware settingsDo the following procedures as you install voice boards. To set the SW100 switch For each Dialogic ISA voice board that has a rotary switch, set the rotary switch to a unique value starting with 0 and continuing in sequence. For example, set the rotary switch on the first three ISA voice boards in the Unity server as shown below. This is also the order in which you install the boards in the server. To s e t t h e S W 4 s w i t c h Set switch SW4 to “Off hook” on all boards as shown below. First ISA board Second ISA board Third ISA board0 1 2 Off hook
APPPENDIX A: Voice and fax boards135 Software settings During Unity Setup, do the following procedure when the Dia- logic D/SC Configuration dialog box appears. To enter Dialogic settings during Unity Setup aChange the value of “BLTInterrupt” to “5.” bChange the value of “BLTAddress” to the appropriate value: Turnkey systemSelect “D0000.” Component systemSelect the address that you reserved during the procedure “To find and reserve memory addresses and an IRQ (ISA boards in a component system only),” on page 35. cClick “OK” to continue. dReturn to the procedure that you were doing when the Dia- logic D/SC Configuration dialog box appeared.
UNITY INSTALLATION GUIDE136 Dialogic D/240PCI-T1 voice boardSwitch SW100 To p v i e w Side view Voice board backplate LED status indicators T1 trunk interfaceO N1 Pin 1: Receive ring Pin 2: Receive tip Pin 3: Chassis ground Pin 4: Transmit ring Pin 5: Transmit tip Pin 6: Chassis ground Pin 7: Chassis ground Pin 8: Chassis ground Connection pinouts The D/240PCI-T1 uses an RJ-48C connector. JP2–JP7CT bus connector
APPPENDIX A: Voice and fax boards137 Hardware settings Do the following procedures as you install voice boards. To set the SW100 switch For each Dialogic PCI voice board that has a rotary switch, set the switch to a unique value starting with 1 and con- tinuing in sequence. For example, set the switch on the first three PCI voice boards in the Unity server as shown below. Install the boards in the server in the same order. To set jumpers JP2 to JP7 Set jumpers JP2 to JP5 to “Off” on each board. For jumpers JP6 and JP7, install shunts on the top two pins (1 and 2). Software settings None. LED status indicators The D/240PCI-T1 includes the following status indicators. First PCI board Second PCI board Third PCI board JP2 JP3 JP4 JP5 JP6 JP7 Setting Color Lit Green The board is powered up and receiving an external signal Yellow Loss of frame synchronization at far end external network Red Loss of frame synchronization on incoming line from external network1 2 3
UNITY INSTALLATION GUIDE138 Dialogic GammaLink CP4/LSI Series 1 fax board Pin 3: First fax line tip Pin 2: First fax line ring Connection pinouts The CP4/LSI Series 1 uses RJ-11 connectors. Pin 1: Second fax line tip Pin 4: Second fax line ring Pin 3: Third fax line tip Pin 2: Third fax line ring Pin 1: Fourth fax line tip Pin 4: Fourth fax line ringSwitch block SW1 Side view Fax board backplate Lines 3 & 4 Lines 1 & 2 LED status indicators Switch block SW1 Side view
APPPENDIX A: Voice and fax boards139 Hardware settings Do the following procedure as you install fax boards. To s e t s w i t c h b l o c k S W 1 The switch block SW1 settings determine the fax ports’ I/O addresses. The CP4/LSI Series 1 board contains four fax ports. Depending on the configuration of the Unity server and on whether Active- Fax is installed on a separate server, you can install up to eight CP4/LSI Series 1 boards. Set the SW1 switches on each board as shown below. LED status indicators There are two LED status indicators for each fax port. The fol- lowing table describes the meaning of the status indicators. SW1 switchSW1 switch First board Ports 0–3Fourth board Ports 12–15 Second board Ports 4–7Fifth board Ports 16–19 Third board Ports 8–11Sixth board Ports 20–23 Color Lit Unlit Blinking Green Port is off hook Port is on hook --- Amber Board is operationalBoard is not operationalBoard configuration problem On Off 123 On Off 123 On Off 123 On Off 123 On Off 123 On Off 123
UNITY INSTALLATION GUIDE140 Dialogic GammaLink CP4/LSI Series 2 (CPi/400) fax board Pin 3: First fax line tip Pin 2: First fax line ring Connection pinouts The CP4/LSI Series 2 uses RJ-11 connectors. Pin 1: Second fax line tip Pin 4: Second fax line ring Pin 3: Third fax line tip Pin 2: Third fax line ring Pin 1: Fourth fax line tip Pin 4: Four th fax line ringLED status indicators Rotar y switch Fax board backplate Lines 3 & 4 Lines 1 & 2 Side view
APPPENDIX A: Voice and fax boards141 The CP4/LSI Series 2 fax board is also known as the CPi/400. Hardware settings Do the following procedure as you install fax boards. To set the rotary switch The rotary switch setting determines the fax ports’ I/O addresses. The CP4/LSI Series 2 board contains four fax ports. Depending on the configuration of the Unity server and on whether Active- Fax is installed on a separate server, you can install up to eight CP4/LSI Series 2 boards. Set the rotary switch on each board as shown below. LED status indicators There are two LED status indicators for each fax port. The fol- lowing table describes the meaning of the status indicators. Rotary switchRotary switch First board Ports 0–3Fourth board Ports 12–15 Second board Ports 4–7Fifth board Ports 16–19 Third board Ports 8–11Sixth board Ports 20–23 Color Lit Unlit Blinking Green Port is off hook Port is on hook --- Amber Board is operationalBoard is not operationalBoard configuration problem 03 14 25
UNITY INSTALLATION GUIDE142 Dialogic GammaLink CPD/220 fax board Fax board backplate Pin 3: Tip 1 Pin 2: Ring 1 DID cable (miniature jack) Miniature jack Pin 1: Ring 2 Pin 4: Tip 2RJ-11 wall jack LED status indicators Pin 1: Ring 2 Pin 2: Ring 1 Pin 3: Tip 1 Pin 4: Tip 2 Switch block SW1 LSI cable (RJ-11 wall jack) Side view