    Have a look at the manual Cisco Systems Active Voice Repartee Unity R2 4 Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 Cisco Systems manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							APPPENDIX A: Voice and fax boards133
    DB-37 pinouts
    Pin 37 is the ground.
    Pins 17, 34, 35, and 36 are unused.
    Continued Line number Tip connection Ring connection
    1 Pin 1 Pin 18
    2 Pin 2 Pin 19
    3 Pin 3 Pin 20
    4 Pin 4 Pin 21
    5 Pin 5 Pin 22
    6 Pin 6 Pin 23
    7 Pin 7 Pin 24
    8 Pin 8 Pin 25
    9 Pin 9 Pin 26
    10 Pin 10 Pin 27
    11 Pin 11 Pin 28
    12 Pin 12 Pin 29
    13 Pin 13 Pin 30
    14 Pin 14 Pin 31
    15 Pin 15 Pin 32
    16 Pin 16 Pin 33 
    						
    							UNITY INSTALLATION GUIDE134
    Dialogic D/160SC-LS 
    Continued
    voice boardHardware settingsDo the following procedures as you install voice boards.
    To set the SW100 switch
    For each Dialogic ISA voice board that has a rotary switch, 
    set the rotary switch to a unique value starting with 0 and 
    continuing in sequence. 
    For example, set the rotary switch on the first three ISA 
    voice boards in the Unity server as shown below. This is also 
    the order in which you install the boards in the server. 
    To  s e t  t h e  S W 4  s w i t c h
    Set switch SW4 to “Off hook” on all boards as shown below.
    First ISA board
    Second ISA board
    Third ISA board0
    1
    2
    Off hook 
    						
    							APPPENDIX A: Voice and fax boards135
    Software settings
    During Unity Setup, do the following procedure when the Dia-
    logic D/SC Configuration dialog box appears. 
    To enter Dialogic settings during Unity Setup
    aChange the value of “BLTInterrupt” to “5.”
    bChange the value of “BLTAddress” to the appropriate value:
    Turnkey systemSelect “D0000.”
    Component systemSelect the address that you reserved 
    during the procedure “To find and reserve memory 
    addresses and an IRQ (ISA boards in a component system 
    only),” on page 35.
    cClick “OK” to continue.
    dReturn to the procedure that you were doing when the Dia-
    logic D/SC Configuration dialog box appeared. 
    						
    							UNITY INSTALLATION GUIDE136
    Dialogic 
    D/240PCI-T1 
    voice boardSwitch SW100
    To p  v i e w
    Side view
    Voice board 
    backplate
    LED status
    indicators
    T1 trunk
    interfaceO
    N1
    Pin 1: Receive ring
    Pin 2: Receive tip
    Pin 3: Chassis ground
    Pin 4: Transmit ring
    Pin 5: Transmit tip
    Pin 6: Chassis ground
    Pin 7: Chassis ground
    Pin 8: Chassis ground
    Connection pinouts
    The D/240PCI-T1 uses an 
    RJ-48C connector.
    JP2–JP7CT bus connector 
    						
    							APPPENDIX A: Voice and fax boards137
    Hardware settings
    Do the following procedures as you install voice boards.
    To set the SW100 switch
    For each Dialogic PCI voice board that has a rotary switch, 
    set the switch to a unique value starting with 1 and con-
    tinuing in sequence. For example, set the switch on the first 
    three PCI voice boards in the Unity server as shown below. 
    Install the boards in the server in the same order. 
    To set jumpers JP2 to JP7
    Set jumpers JP2 to JP5 to “Off” on each board. For jumpers 
    JP6 and JP7, install shunts on the top two pins (1 and 2). 
    Software settings
    None.
    LED status indicators
    The D/240PCI-T1 includes the following status indicators.
    First PCI board
    Second PCI board
    Third PCI board
    JP2 JP3 JP4 JP5 JP6 JP7
    Setting
    Color Lit
    Green The board is powered up and receiving an external signal
    Yellow Loss of frame synchronization at far end external network
    Red Loss of frame synchronization on incoming line from external 
    network1
    2
    3 
    						
    							UNITY INSTALLATION GUIDE138
    Dialogic 
    GammaLink 
    CP4/LSI 
    Series 1 
    fax board
    Pin 3: First fax line tip Pin 2: First fax line ring
    Connection pinouts
    The CP4/LSI Series 1 
    uses RJ-11 connectors.
    Pin 1: Second fax line tip
    Pin 4: Second fax line ring
    Pin 3: Third fax line tip Pin 2: Third fax line ring
    Pin 1: Fourth fax line tip
    Pin 4: Fourth fax line ringSwitch block SW1
    Side view
    Fax board backplate
    Lines 3 & 4
    Lines 1 & 2
    LED status indicators
    Switch block SW1
    Side view 
    						
    							APPPENDIX A: Voice and fax boards139
    Hardware settings
    Do the following procedure as you install fax boards.
    To  s e t  s w i t c h  b l o c k  S W 1
    The switch block SW1 settings determine the fax ports’ I/O 
    addresses.
    The CP4/LSI Series 1 board contains four fax ports. Depending 
    on the configuration of the Unity server and on whether Active-
    Fax is installed on a separate server, you can install up to eight 
    CP4/LSI Series 1 boards.
    Set the SW1 switches on each board as shown below.
    LED status indicators
    There are two LED status indicators for each fax port. The fol-
    lowing table describes the meaning of the status indicators.
    SW1
    switchSW1
    switch
    First board
    Ports 0–3Fourth board
    Ports 12–15
    Second board
    Ports 4–7Fifth board
    Ports 16–19
    Third board
    Ports 8–11Sixth board
    Ports 20–23
    Color Lit Unlit Blinking
    Green Port is off hook Port is on hook ---
    Amber Board is 
    operationalBoard is not 
    operationalBoard configuration 
    problem
    On
    Off
    123
    On
    Off
    123
    On
    Off
    123
    On
    Off
    123
    On
    Off
    123
    On
    Off
    123 
    						
    							UNITY INSTALLATION GUIDE140
    Dialogic 
    GammaLink 
    CP4/LSI 
    Series 2 
    (CPi/400) 
    fax board
    Pin 3: First fax line tip Pin 2: First fax line ring
    Connection pinouts
    The CP4/LSI Series 2 
    uses RJ-11 connectors.
    Pin 1: Second fax line tip
    Pin 4: Second fax line ring
    Pin 3: Third fax line tip Pin 2: Third fax line ring
    Pin 1: Fourth fax line tip
    Pin 4: Four th fax line ringLED status indicators
    Rotar y switch
    Fax board backplate
    Lines 3 & 4
    Lines 1 & 2
    Side view 
    						
    							APPPENDIX A: Voice and fax boards141
    The CP4/LSI Series 2 fax board is also known as the CPi/400.
    Hardware settings
    Do the following procedure as you install fax boards.
    To set the rotary switch
    The rotary switch setting determines the fax ports’ I/O 
    addresses.
    The CP4/LSI Series 2 board contains four fax ports. Depending 
    on the configuration of the Unity server and on whether Active-
    Fax is installed on a separate server, you can install up to eight 
    CP4/LSI Series 2 boards.
    Set the rotary switch on each board as shown below.
    LED status indicators
    There are two LED status indicators for each fax port. The fol-
    lowing table describes the meaning of the status indicators.
    Rotary
    switchRotary
    switch
    First board
    Ports 0–3Fourth board
    Ports 12–15
    Second board
    Ports 4–7Fifth board
    Ports 16–19
    Third board
    Ports 8–11Sixth board
    Ports 20–23
    Color Lit Unlit Blinking
    Green Port is off hook Port is on hook ---
    Amber Board is 
    operationalBoard is not 
    operationalBoard configuration 
    problem
    03
    14
    25 
    						
    							UNITY INSTALLATION GUIDE142
    Dialogic 
    GammaLink 
    CPD/220 
    fax board
    Fax board backplate
    Pin 3: Tip 1 Pin 2: Ring 1
    DID cable (miniature jack)
    Miniature 
    jack
    Pin 1: Ring 2
    Pin 4: Tip 2RJ-11 
    wall jack
    LED status indicators
    Pin 1: Ring 2
    Pin 2: Ring 1
    Pin 3: Tip 1
    Pin 4: Tip 2
    Switch block 
    SW1
    LSI cable (RJ-11 wall jack)
    Side view 
    						