Home > ATT > Communications System > ATT System 25 Installation And Maintenance Manual

ATT System 25 Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual ATT System 25 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 438
    							INSTALLATION
    Connection to TN763 Auxiliary Trunk CP (278A Adapter
    Required)
    A 278A Adapter is required to connect paging equipment to a TN763 Auxiliary
    Trunk CP (Figure 2-56) when the following conditions
    l Paging equipment is not FCC registered.
    l Paging equipment requires a contact closure
    Connect as shown in Figure 2-56, following the steps
    1.
    2.
    3.
    4.Connect the CP to a 66-type block, using
    Use kit-of-parts D-1 81524 (PEC 6251 1).
    Note:The 66-block provides a 3-pairexist:
    for proper operation.
    below:
    an A25D 25-pair cable.
    interface to TN763
    (see Appendix A of this manual for details).
    Using 4-pair inside wiring cable,
    66-type block to a 278A adapter.
    CP Leads*
    T
    R
    SZ
    SZl
    S
    S1
    l T,R is the voice pair; SZ,SZ1 is
    is the seizure acknowledge pair.
    connect the following leads on the
    278A Term.
    T
    R
    BZ1
    GRD
    BY1
    BY2
    the seizure request pair; and S,S1
    Open the 278A adapter, and install a strap between terminals BZ2
    and -V.
    Move the yellow shorting plugs so that the following connections are
    made (Figure 2-57).
    A to B
    E to F
    G to H
    D to C and J to K should be open.
    2-124 
    						
    							INSTALLATION
    Loudspeaker
    System
    Cross
    Connect
    Field Red
    103A
    or
    Wall
    Jack Green
    Line CordB25A
    or
    A25D
    Auxiliary Cabinet or Wall Field
    T
    25-Pair
    F Conn.on ED-
    1E443-
    10
    PanelT
    R909A/B Universal Coupler
    25-PairF Conn.on ED-
    1E443-
    10
    Panel PG1/BZ1
    BSY1/BY1
    BSY2/BY2
    PG2/BZ2 CMS2/M2
    CMS1/M1
    Music
    Source-48 V DC
    Power SupplyPWR GRD
    +/-9.5-60V dc
    Power Supply
    Port Cabinet
    * Replaces: 36A Voice Coupler
    89A Control Unit
    27BA Adapter
    TN763
    Circuit
    Pack
    Figure 2-55a. Loudspeaker Paging with Background Music
    November 1995
    2-124a 
    						
    							INSTALLATION
    This page intentionally left blank.
    2-124bNovember 1995 
    						
    							INSTALLATION
    5.
    6.
    7.
    8.
    9.
    10.
    11.
    Set switch to NORMAL position.
    Using a D4BY (single-ended) modular cord, connect D-181321 kit of
    parts (Figure 2-56) to a KS-22911, L2 power supply (-48V dc).
    Connect terminals -V and GRD on 278A adapter to D-kit.
    If background music is desired, connect terminals Ml and M2 on the
    278A Adapter to the customer-provided music source.
    Connect the 278A adapter to a 103A connecting block, using 4-pair
    inside wiring cable.Make the following connections:
    278A Term.103A Term.
    CT1
    CR2
    C15
    C26
    Using a D4BU cord, connect the paging system to the connecting
    block.
    If you are installing a PagePac system, connect the speakers to the
    receptacle on the back of the PagePac system.
    2-125 
    						
    							INSTALLATION
    LEGEND :
    TN763 - AUXILIARY
    A-
    B1 -
    C5 -
    C6 -
    P1 -
    W1 -
    278A
    SINGLE-ENDED
    TRUNK CP
    25 PAIR CONNECTOR CABLE (A25D)
    TYPICAL -103A CONNECTING BLOCK
    MODULAR CORD (D4BU-87)
    SINGLE-ENDED MODULAR CORD
    KS-22911, L2, POWER SUPPLY, -48 VOLT DC
    INSIDE WIRING CABLE (4-PAIR)
    ADAPTER -REQUIRES –24 VOLT ZENER DIODE KIT OF PARTS
    NOTES :
    1. APPARATUS CODE D-181523 INCLUDES
    66E3-25 BLOCK CONNECTOR AND CABLE B25A 15/DE.
    2. APPARATUS CODE D-181524 INCLUDES C6, P1, 278A
    ADAPTER AND ZENER KIT.
    Figure 2-56.Paging System Connection to TN763 Circuit Pack (278A
    Adapter Required)
    2-126 
    						
    							Figure 2-57.278A Adaptor Plug Positions for Connecting TN763 Circuit
    Pack to Paging System
    2-127 
    						
    							INSTALLATION
    Connection to ZTN76 or ZTN77 CP
    PagePac 20 system with ZoneMate 9/39 and Common Control Unit (CCU)
    provides up to nine/thirty-nine paging zones and multizone groups.
    To connect a PagePac 20 system, make connections using the following
    steps (Figure 2-58):
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    Place the PagePac amplifier on the ZoneMate and the CCU.
    Connect the three units as follows:
    a.Plug the cord attached to the CCU into the modular jack on
    the PagePac system.
    b. Connect the 25-pin cable between the ZoneMate and the
    CCU.
    c.
    Plug GR Molex connector from CCU into PagePac 20.
    Using a D4BU modular cord connect the jack on the back of the
    CCU to the 103A connecting block.
    Using 4-pair inside wiring cable, connect the 103A connecting block
    to the TAE 700A block. Make the following connections:
    700A Block Term.103A Term.
    T1
    R2
    Attach the speakers to the ZoneMate.
    Set the switch on the CCU to LS for loop-start trunks or GS for
    ground-start trunks.
    For ground start trunks, connect the black lead from the 2-pair cord
    supplied with PagePac 20 to the System 25 cabinet ground block.
    2-128 
    						
    							INSTALLATION
    LEGEND :
    ZTN76 -
    ZTN77 -
    A-
    B1 -
    C5 -
    W1 -GROUND START C’
    LOOP START C’
    3 TO 1 SPLITTER CABLE (WP-90929,L1)
    TYPICAL- 103A CONNECTING BLOCK
    MODULAR CORD (D4BU-87)
    INSIDE WIRING CABLE (4-PAIR)
    Figure 2-58.PagePac 20 System Connection to ZTN76 or ZTN77 Circuit
    Pack
    2-129 
    						
    							INSTALLATION
    Customer-provided paging equipment can also be connected to ZTN76 or
    ZTlN77 CO trunk CPs. Connection to the system is made through the TAE
    appearance of the Tip/Ring pair of the CO trunk CP (See Appendix A for
    connection details). A paging equipment interface kit D-181900 consisting of
    a Universal Telephone Access Module (UPAM) and a -48 VDC power supply,
    PRS-48, is required unless all of the following conditions exist:
    l Paging equipment is FCC registered.
    l Paging equipment does not require a contact closure for proper
    operation.
    l A trunk interface is provided.
    If kit D-181900 is required, make connections using 4-pair inside wiring as
    listed below (Figure 2-59):
    1.Connect UPAM chassis ground to building ground.
    2. Connect UPAM terminals PT and PR to paging equipment.
    3. Connect UPAM terminals +24/48 and -24/48 to respective PRS-48
    power supply terminals +48VDC and -48VDC. For ZTN76 ground
    start CP only, connect +48VDC to System 25 system ground which
    appears on the TAE block (Appendix A).
    4. Connect UPAM terminal R to trunk CP ring lead appearing on TAE
    block.
    For ZTN76 ground start CP connect UPAM terminal T to UPAM terminal N.O.
    and connect UPAM terminal COM to trunk CP tip lead appearing on TAE
    block.
    For ZTN77 loop start CP connect UPAM terminal T directly to trunk CP tip
    lead appearing on TAE block.
    If kit D-181900 is not required, use 4-pair inside wiring and connect paging
    equipment directly to trunk CP tip and ring leads appearing on TAE block.
    2-130 
    						
    							INSTALLATION
    LEGEND :
    ZTN76- GROUND START CP
    ZTN77- LOOP START CP
    A-3 TO 1 SPLITTER CABLE (WP-90929,L1)
    UPAM -UNIVERSAL TELEPHONE (PAGING) ACCESS MODULE
    P1- PRS-48 POWER SUPPLY
    W1- INSIDE WIRING CABLE (4-PAIR)
    NOTES :
    1. APPARATUS CODE D-181523 INCLUDES
    66E3-25 BLOCK CONNECTOR AND CABLE
    B25A 15/DE.
    2. APPARATUS CODE 0-181900 INCLUDES UPAM AND
    PRS-48 POWER SUPPLY. D-181900 IS REQUIRED
    UNLESS ALL OF THE FOLLOWING CONDITIONS EXIST:
    l PAGING EQUIPMENT IS FCC REGISTERED
    l PAGING EQUIPMENT DOES NOT REQUIRE A CONTACT
    CLOSURE FOR PROPER OPERATION
    l A TRUNK INTERFACE IS PROVIDED.
    Figure 2-59.
    Paging System Connection to ZTN76 or ZTN77
    2-131 
    						
    All ATT manuals Comments (0)