    							INSTALLATION
    LEGEND:
    ZTN79 -
    WP90851-L1 -
    A2 -
    B1 -
    C1 -
    C2 -
    C3 AND C4 -
    P1-
    W1 -
    Figure 2-51.HYBRID LINE CP
    MODULAR Y ADAPTER
    KS-23475 ADAPTER
    TYPICAL -103A CONNECTING
    MODULAR CORD (D8W-87)
    OCTOPUS CABLE (WP90780)
    MODULAR CORDS BUILT INTO
    KS-23475 ADAPTER
    KS-22911 POWER SUPPLY
    INSIDE WIRING CABLE
    I
    PERSONAL
    COMPUTER
    STARLAN NETWORK
    WORKSTATION
    7300H Series Terminal/STARLAN NETWORK Workstation
    Connections
    2-116 
    						
    							INSTALLATION
    INSTALL MUSIC-ON-HOLD INTERFACE
    Note:Use of equipment that rebroadcasts copyrighted music or
    other material may be required to obtain a license from a
    third party such as ASCAP or BMI.
    FCC-Registered Music Source Interface
    The music source is connected to a ZTN78 CP through the SIP (see Figure
    2-52).
    1.
    2.
    3.
    4.
    Using an octopus cable, connect the CP to an 858A Adapter at the
    SIP.
    Using inside wire, connect T and R leads on the other side of the
    858A Adapter to the PT and PR terminals on the Music-on-Hold
    (MOH) interface (KS-23395).
    Connect the T and R terminals on the MOH interface to terminals 1
    and 2 on a 103A Connecting Block.
    Connect the music source to the 103A block using a D4BU-87
    modular cord.
    2-117 
    						
    							INSTALLATION
    LEGEND :
    TN742 –
    ZTN78 –
    B1 -
    C2 -
    C5 -
    W1 –
    MOH -
    ANALOG LINE CP
    TIP RING CP
    TYPICAL -103A CONNECTING BLOCK
    OCTOPUS CABLE (WP90780) PEC 2720-05P
    MODULAR CORD (D4BU-87)
    INSIDE WIRING CABLE
    KS-23395 INTERFACE
    Figure 2-52.Music Source, FCC Registered
    2-118 
    						
    							INSTALLATION
    Non-FCC Registered Music Source Interface
    The music source is connected to a ZTN78 CP (see Figure 2-53). Connect
    the CP to a 858A Adapter at the SIP.
    Follow the instructions for installing FCC-registered equipment. You must
    also install a kit-of-parts (D-181575; includes 36A Voice Coupler, 201213
    transformer, and KS-23395 MOH interface). Follow the wiring instructions
    included with the kit.
    LEGEND:
    TN742 - ANALOG LINE CP
    ZTN78 - TIP RING CP
    B1- TYPICAL -
    103A CONNECTING BLOCK
    C2 - OCTOPUS CABLE ( WP90780 )
    C6 - SINGLE-ENDED MODULAR CORD, D4BY
    W1
    - 4-PAIR INSIDE WIRING CABLE
    Figure 2-53.Music Source, Non-FCC Registered
    2-119 
    						
    							INSTALLATION
    Music Source
    (Customer supplied)
    Music-on-Hold
    interface
    (KS-23395)
    GRGR             GR
    MSHI
    q
    q
    q(Optional)DW8A-SE909A/B
    Univversal Coupler
    (Replaces 36A
    Voice Coupler)
    MSHI               CTCT
    J2
    MSLOMSLO                     CRCR
    Twisted Pair
    26AWG Min.PR             R
    J1
    PT             TT
    System 25
    DW8A-SE
    J3
    ZTN78
    Circuit
    Pack858A
    Adapter
    -48VGRD
    -48dc
    Power
    Source
    WP-90780
    Octopus Cable
    Figure 2-53a. Music-on-Hold
    November 19952-119a 
    						
    							INSTALLATION
    2-119b
    This page intentionally left blank.
    November 1995 
    						
    							INSTALLATION
    INSTALL EXTERNAL ALERTS
    External
    54).
    1.
    2.
    3.
    alerts are connected to the system through a ZTN78 CP (Figure 2-
    Connect the CP to a 858A Adapter at the SIP.
    Connect the other side of the adapter to a 103A Connecting Block
    using building wiring.
    Connect the block and alerting device with a D4BU cord.
    LEGEND :
    TN742 - ANALOG LINE CP
    ZTN78 - TIP RING CP
    B1- TYPICAL -103A CONNECTING BLOCK
    C2 - OCTOPUS CABLE ( WP90780 )
    C5 - MODULAR CORD ( D4BU-87 )
    R1- ElCM-50 RINGER OR EQUIVALENT
    W1- INSIDE WIRING CABLE
    Figure 2-54.External Alerts
    2-120 
    						
    							INSTALLATION
    INSTALL RECORDED DELAY ANNOUNCEMENT
    Delayannouncements are installed the same way as external alerts.
    INSTALL DICTATION SYSTEM INTERFACE
    If the equipment does not require a contact closure, follow the instructions
    for installing external alerts.
    If the equipment requires a contact closure, follow the instructions below for
    connecting a paging system to the TN763 CP.
    INSTALL PAGING SYSTEM INTERFACE
    PagePac*Paging System,
    or compatible paging equipment, may be
    connected to System 25.
    System 25 provides three types of paging system interfaces. The paging
    equipment can be connected to a TN763 Auxiliary Trunk, ZTN76 Ground
    Start, or ZTN77 Loop Start Trunk CP.The type of connection provided
    depends on the customer’s equipment and/or requirements. Read the
    paragraphs preceding the instructions provided to determine the correct
    procedure.
    Note:The PagePac 20 system is not normally connected to an
    Auxiliary Trunk CP because only 1-zone paging is provided
    by this connection.However, three PagePac systems can be
    used for three zones provided by TN763.
    lTrademark of Harris Corporation Dracon Division
    2-121 
    						
    							INSTALLATION
    Direct Connection to TN763 Auxiliary Trunk CP
    Paging
    (Figure
    l
    l
    equipment can be connected directly to a TN763 Auxiliary Trunk CP
    2-55) when the following conditions exist:
    Paging equipment is FCC registered.
    Paging equipment requires a contact closure
    Connect as shown in Figure 2-55, following the steps
    1.Connect the CP to a 66-type block, using
    Use kit-of-parts D-1 81524 (PEC 62511).
    Note:The 66-block provides a 3-pairfor proper operation.
    below:
    an A25D 25-pair cable.
    interface to TN763
    (see Appendix A of this manual for details).
    2.Using 4-pair inside wiring cable, connect the 66-block to a 103A
    connecting block. Make the following connections:
    66-Block Term.*103A Term.
    T1
    R2
    SZ3
    SZl4
    s5
    S16
    * T,R is the voice pair; SZ,SZ1 is the seizure request pair; and S,S1
    is the seizure acknowledge pair to the TN763.
    3.Using a D4BU cord, connect the paging equipment to the 103A
    block.
    4.If you are installing a PagePac 20 system, connect the speakers to
    the receptacle on the back of the PagePac system.
    2-122 
    						
    							INSTALLATION
    SYSTEM 25
    CABINETPART OF
    25 PAIR CABLE
    PART OF
    66-BLOCK
    AW1C5
    TN763B1
    <
    PAGING OR
    DICTATION
    SYSTEM
    LEGEND :
    TN763– AUXILIARY TRUNK CP
    A – SINGLE-ENDED 25 PAIR CONNECTOR CABLE (A25D)
    B1 -TYPICAL -103A CONNECTING BLOCK
    C5 -MODULAR CORD (D4BU-87)
    W1 -INSIDE WIRING CABLE (4-PAIR)
    NOTE :
    Figure
    APPARATUS CODE D-181523 INCLUDES
    66E3-25 BLOCK CONNECTOR AND CABLE
    B25A 15/DE.
    2-55.Paging System Connection to TN763 Circuit Pack
    2-123 
    						