Home > ATT > Communications System > ATT System 25 Installation And Maintenance Manual

ATT System 25 Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual ATT System 25 Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 438
    							APPENDIX E: Administration Codes and Data
    Table E-AE.Pod/Board Type—Specific Representation (Contd)
    CATEGORY:DESCRIPTION:DATA:
    Voice Station
    (Contd)
    ATTENDANT VOICE TERMINALS:
    Direct Trunk Attendant Console
    (34-Button Deluxe or
    34-Button Deluxe
    Built-in-Speakerphone)309
    Switched Loop Attendant Console
    (34-Button Built-in-Speakerphone
    with 16-Character Display) 
    -310
    Switched Loop Attendant Console,
    Deluxe (34-Button Deluxe
    Built-in-Speakerphone with
    16-Character Display)311
    MET VOICE TERMINALS:
    10-Button MET401
    10-Button MET with Built-in-
    Speakerphone401
    12-Button MET401
    Trunk
    Ground Start, CO701
    Ground Start, WATS702
    Loop Start, CO801
    Loop Start, WATS802
    PBX/Centrex805
    DID Immediate Dial901
    DID Wink Start902
    1001
    1002
    1003
    1004
    1005
    1006
    E-52 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-AE.Port/Board Type—Specific Representation (Contd)
    CATEGORY:DESCRIPTION:DATA:
    Trunk
    (Contd)
    Delay Dial-in/Auto-out
    1007
    Delay Dial-in/Delay Dial-out
    1008
    Special
    Service Circuit ZTN85 (R1V1, R2V2)
    1101
    Service Circuit Pack ZTN131 (R3)1102
    External Alerts
    253
    First Paging Zone
    1301
    Second Paging Zone1302
    Third Paging Zone
    1303
    DGC Delay Announcement
    255
    Music-on-Hold
    254
    First Selector Console
    1601
    Second Selector Console1602
    First Directed Night Service Delay
    251
    Announcement
    Second Directed Night Service Delay252
    Announcement
    Pooled Modem
    1901
    Tone Detector
    2101
    Dial Dictation
    201 and/
    or 2201
    VMS: Standard Voice Mail Services260
    VMS: Call Coverage/Auto-Attendant261
    VMS: Message Drop
    262
    VMS: Announcement Service
    263
    Data
    Standard Data Port1801
    STARLAN Interface Port (STARLAN CP),1802
    DLC compatible
    E-53 
    						
    							APPENDIX E:
    Table
    For Action=1,Administration Codes and Data
    E-K Save/Restore and System Restarts (Menu=9)
    you need to press the PLAY and RECORD buttons.
    For Action=2 and Action=3, you need to press the PLAY button.
     ACTIONDESCRIPTIONDATA
    1Save (Backup) translations[1 to run]
    2Verify translations[1 to run]
    3Restore translations[1 to run]
    10
    Force a system warm start.FOR[1 to run]
    QUALIFIED SYSTEMS TECHNICIAN
    ONLY
    20
    Force a system cold start.FOR [1 for Full
    QUALIFIED SYSTEMS TECHNICIAN
    Default, 2 for
    ONLY.
    Full Default cold start willLimited Default]
    reinstate all default values (true cold
    start).
    Limited Default  cold start will
    reinstate default values everywhere
    except for port boards.
    Caution:Action=3 will interrupt phone service for about ten
    minutes.
    You should save and restore translations during system off-hours, since
    these operations can affect phone service and call traffic can affect these
    operations.
    E-54 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-AG.RS232 Port Administration (Menu=10)
    In response to RS232=,enter the RS232 connector (1-5*) to be
    administered.
    ACTIONDESCRIPTIONDATA
    1Reassign RS232 connector capability[0 to disconnect
    port or see
    footnote † for
    options and
    defaults]
    2For Ports 1-4 ONLY*: Change the[0-2;0]
    RETURN delay
    3For Ports 1-4 ONLY*: Change the[300, 1200,
    baud rate4800, 9600
    See footnote †
    for defaults]
    lPorts 1-4 are the RS232 connectors off the Call Processor. Port 5 is a special modem port
    accessed through the switch fabric for RIMS.
    † The default for each Target connector is as follows:
    TARGET DEFAULT DATA (= Capability) DEFAULT BAUD RATE
    11 (= Administration)1200, 300 (auto-baud)
    22 (=SMDR)1200
    33 (= Save/Restore Tape)1200
    4
    Reserved9600, 1200 (auto-baud)
    5RIMS1200
    E-55 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-AH.Automatic Route Selection Administration (Menu=1)
    ACTIONDESCRIPTIONDATA
    100Assign a pattern number[1-8]
    101
    Assign a start time for subpattern 1 A in[HHMM]
    the form HOUR, MINUTES (HHMM)
    102
    Assign a stop time for subpattern 1A[HHMM]
    110Assign Route 1 for subpattern 1A (a
    [FAC or VFC]
    facility access code [FAC] or virtual
    facility code [VFC])
    111Assign facility restriction level (FRL O-3)[FRL]
    for subpattern 1A, route 1
    120Assign Route 2 for subpattern 1A (a[FAC or VFC]
    facility access code [FAC] or virtual
    facility code [VFC])
    121 Assign facility restriction level (FRL O-3)[FRL]
    for subpattern 1A, route 2
    130Assign Route 3 for subpattern 1 A (a[FAC or VFC]
    facility access code [FAC] or virtual
    facility code [VFC])
    131Assign facility restriction level (FRL O-3)[FRL]
    for subpattern 1A, route 3
    140Allow subpattern 1A to overflow to[1/0]
    DDD (1=YES,0=NO)
    141
    Assign facility restriction level (O-3) for[FRL]
    DOD overflow
    200Assign a pattern number[1 -8]
    210Assign Route 1 for subpattern 1 B (a[FAC or VFC]
    facility access code [FAC] or virtual
    facility code [VFC])
    211Assign facility restriction level (FRL O-3)[FRL]
    for subpattern 1 B, route 1
    220Assign Route 2 for subpattern 1 B (a[FAC or VFC]
    facility access code [FAC] or virtual
    facility code [VFC])
    221Assign facility restriction level (FRL O-3)[FRL]
    for subpattern 1 B, route 2
    E-56 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-AH. Automatic Route Selection Administration(Menu=11)
    (Contd)
    ACTIONDESCRIPTIONDATA
    230Assign Route 3 for subpattern 1 B (a[FAC or VFC]
    facility access code [FAC] or virtual
    facility code [VFC])
    231Assign facility restriction level (FRL 0-3)[FRL]
    for subpattern 1 B, route 3
    240Allow subpattern 1 B to overflow to[1/0]
    DDD (1=YES,0=NO)
    241Assign facility restriction level (0-3) for[FRL]
    DDD overflow
    300Area Code for which an ARS pattern is[Area Code]
    being assigned
    301
    ARS pattern number associated with[1-8; O for none; 1]
    this Area Code
    401Assign the ARS access code[dial code: 9]
    402Assign ARS pattern number for[1-8; 0 for none; 0]
    international calls
    500Home Area Code (HAC) exception list[1-4]
    number (l-4)
    501ARS routing pattern associated with[1-8]
    this HAC exception list
    511
    Display CO codes on this HAC
    exception list (READ ONLY)
    512
    Add CO code to HAC exception list[Code Number]
    513Remove CO code from HAC exception[Code Number]
    list
    521Display HAC exception list telephone[7-digit number]
    numbers (7 digits)
    522Add a (7-digit) telephone number to the[7-digit number]
    HAC exception list
    523Remove a (7-digit) telephone number
    [7-digit number]
    from the HAC exception list
    E-57 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-AH. AutomaticRoute Selection Administration (Menu=11)
    (Contd)
    ACTIONDESCRIPTlONDATA
    601Assign a 7-digit emergency telephone[7-digit number]
    number
    602Assign a 7-digit emergency telephone[7-digit number]
    number
    603Assign a 7-digit emergency telephone
    [7-digit number]
    number
    700Enter facility (route) code number
    [FAC or VFC]
    701Assign associated area code[Associated
    area code]
    702Specify how many digits to strip from[Number of digits]
    the front when the dialed number is to
    the associated area code
    703Specify digits to be prefixed, after[Digits to be
    deleting digits as specified by Actionprefixed]
    702 above, for calls to the associated
    area code
    704Specify how many digits to strip from
    [Number of digits]
    the front when the dialed number is
    NOT to the associated area code
    705Specify digits to be prefixed, after[Digits to be prefixed]
    deleting digits as specified by Action
    704 above, for calls NOT to the
    associated area code
    800Pattern number for other area codes[1-8]
    exception telephone numbers
    821Display entries in other area codes
    .
    exception list
    822Add a number to the other area codes[Number]
    exception list (first 8 or fewer digits of
    a 10-digit telephone number)
    823Remove a number from the other area[Telephone number]
    code exception list
    E-58 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-AH.Automatic Route Selection Administration
    (Menu=11)
    (Contd)
    ACTIONDESCRIPTlON
    DATA
    900
    N11 CO exchange for which a pattern[N11 code]
    is being assigned (where N=2-8)
    901ARS pattern number to route these[1-8 or O if this
    N11 callsN11 Code must
    be followed by
    4 other digits
    (N11 -XXXX)]
    E-59 
    						
    							APPENDIX F:
    Administration Error Messages
    APPENDIX F shows Basic Administration error codes and descriptions. The
    Advanced Administration system uses different terminology. For additional
    details about an error message in Basic Administration, press the “?” key.
    The following table lists and describes error messages that can be displayed at
    the SAT while administering the system.
    The table also includes possible
    solutions for some of the error messages.
    AND DESCRIPTIONERROR MESSAGE
    POSSIBLE SOLUTION
    1000:entry out of range must be
    Entered data must be a 3- or 4-digit
    3-4 digitsnumber or 0.
    1001:incorrect entry
    This error occurs you try to change
    must be 0 with equipped
    the terminal code type. EXAMPLE:
    facility
    Go to MENU 2 (PDC). Go to any
    PDC target value and type
    ACTION = 1, you see
    DATA = terminal code
    type 304 etc.
    (Try to change the DATA value to
    another terminal code type) DATA =
    305 you get error 1001: (You have to
    O the terminal type code if you want
    to change its value)
    1002:incorrect PDC
    Could be existing PDC number
    does not exist or used
    Go to MENU 8 (search)
    improperly
    ACTION = 1 DATA= 11
    Hit c to continue to search for
    assigned PDCs
    1003:inappropriate request
    The entered mode does not exist.
    incorrect mode
    1004:incorrect entry or cabinet
    Cabinet-Slot-Port (CSSPP) SS must
    number out of range
    be a number from 1 to 3
    1005:incorrect entry
    Cabinet-Slot-Port (CSSPP) SS must
    slot number out of rangebe a number from 1 to 12
    F-1 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    1006:incorrect entryCabinet-Slot-Port (CSSPP) PP must
    port-on-board number out
    be a number from 1 to 8 (varies on
    of rangedifferent circuit packs)
    1007:incorrect action number
    Must administer ACTION = 1 before
    can ‘t exceed 1 withproceeding.
    unequipped facility
    1008:incorrect entryThe entered port is greater than
    port-on-board number out
    maximum port number on the
    of rangeassociated board.
    1009:incorrect entryNumber must be 5 digits. Nonspecial
    number must be 5 digitsport does not have 5 digits.
    1010:incorrect facility typeThe facility type is not valid for this
    does not exist or usedsystem.
    improperly
    1011:inappropriate requestGo to MENU 5 (FPDC)
    FPDC already existsACTION = 1
    Hit c to continue to list FPDCs.
    FPDC could be not assigned.
    1012:incorrect PDC
    The entered number is valid but is not
    does not exist or useda station or data port.
    improperly
    1013:inappropriate requestPort type has to be administered
    slot not equipped before proceeding.
    1014:inappropriate request
    Must be a station supported by
    must be stationSystem 25. See Voice Terminal Type
    Codes in Administration Manual. Can
    only move port associated with
    station.
    1015:inappropriate requestCan not move the port associated
    can’t move CAP portwith the CAP.
    1016:incorrect action number
    Item numbers must be 0-2 at this
    must be 0-2point.
    F-2 
    						
    All ATT manuals Comments (0)

    Related Manuals for ATT System 25 Installation And Maintenance Manual