    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTION
    POSSIBLE SOLUTION
    7037:inappropriate request
    Direct Group Calling Delay
    announcement groupAnnouncement (1 per system).
    already exists
    (Need a ZTN78 or TN742 CP port)
    Go to MENU = 8 Search
    ACTION = 1 DATA = 16
    ACTION = 2 DATA = 255
    ACTION = 3 DATA = 0
    (hit c to continue)
    Directed Night Service Delay
    Announcement (2 per system)
    (Need a ZTN78 or TN742 CP port)
    Go to MENU = 8 Search
    ACTION = 1 DATA = 16
    ACTION = 2 DATA = 251 or 252
    ACTION = 3 DATA = 0
    (hit c to continue)
    7039:
    incorrect PDCThe 1st digit of 4 is ambiguous.
    first digit ambiguous
    7040:
    incorrect PDC
    The 2nd digit of 4 is ambiguous.
    second digit ambiguous
    7041:incorrect PDC
    The 3rd digit of 4 is ambiguous.
    third digit ambiguous
    7042:incorrect PDCThe 4th digit of 4 is ambiguous.
    fourth digit ambiguous
    7045:
    inappropriate request
    Do a Search to find the DGC group
    PDC already member ofthat the PDC is a member of.
    the DGC group
    Go to MENU = 8 Search
    ACTION = 1 DATA = 6
    ACTION = 2 DATA = PDC
    (hit c to continue)
    7046:incorrect entry
    The entered data must be 0 to
    data must be 0
    show that the customer is
    continuing the moving of a station 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    7047:incorrect PDCCan verify that the PDC is not in a
    not in any DGC groupDGC group by:
    Go to MENU = 8 Search
    ACTION = 1 DATA = 6
    ACTION = 2 DATA = PDC
    (hit c to continue)
    7048:incorrect PDC
    Do a Search to find the DGC group
    not in this DGC groupthe PDC is a member of.
    Go to MENU = 8 Search
    ACTION = 1 DATA = 6
    ACTION = 2 DATA = PDC
    (hit c to continue)
    7049:
    incorrect PDCIncorrect virtual facility access code.
    must enter pool member
    7050: 
    action number out ofMust administer the access code
    sequencebefore administering the speed
    must enter access codedialing number.
    Go to MENU = 4
    System Administration
    ACTION = 25 DATA = 100-189
    ACTION = 26 DATA = Speed
    Number [0-9, * , #]
    Must administer the access code
    before administering the virtual
    facility number.
    ACTION = 25 DATA = 190-199
    ACTION = 26 DATA = VF number
    [0-9*, #]
    7051:entry out of rangeAccess code must be 100-189 for
    speed number must besystem speed dialing.
    100-189
    7052:incorrect entry
    Speed number must be [0-9, *, #].
    illegal character within
    speed number
    7053:entry out of rangeUnder Administering System-Wide
    must be 0-1 for pooledOptions in the Admin. manual for
    modem optionspooled modem options must be a
    0-1
    F-24 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTION
    POSSIBLE SOLUTION
    7054:out of spaceSystem speed digit pool is full.
    no more room in digit
    pool
    7200:entry out of rangeInvalid TARGET value specification.
    RS232 value out of rangeTarget value should be 1-4. See:
    MENU = 10 (RS232)
    7202:inappropriate requestACTION = 0 under MENU = 10
    improper procedure(RS232) is invalid.
    7203:incorrect entryMENU = 10 (RS232) ACTION = 1
    logical channel out of
    DATA = must be 1-4 (anything else
    range
    is invalid.)
    7204:incorrect entryMENU = 10 (RS232) ACTION = 2
    return delay out of rangeDATA = must be 0-2
    7206:incorrect entryMENU = 10 (RS232) ACTION = 3
    incorrect baud rate
    DATA = baud rates must be 300,
    1200, 4800, 9600.
    Legal baud rates for Administration
    and Maintenance are 1200, 4800,
    9600. Legal baud rate for SMDR is
    1200. Legal baud rate for Tape is
    1200.
    7300:incorrect action number
    Under Save/Restore, MENU = 9
    data must be 1,2,3,10 orAction values must be 1,2,3,10, or
    2020.
    7302:inappropriate request
    Cannot administer system during
    can’t update translation -tape backup.
    tape lockout
    7400:incorrect entryMENU = 10 (RS-232) TARGET = 3
    data must be 1 or 4 onlyACTION = 1 DATA = 2 or 3
    SMDR output can come out of the
    NOTE: Above istape port.
    statement is wrong.
    data must be 2 or 3 only
    F-25 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    7401:incorrectMENU = 10 (RS-232) TARGET = 1
    entryACTION = 1 DATA = 1 or 4
    data must be 2 or 3(Reassign RS232 connector)
    NOTE: Above statement
    is wrong. data must be 1
    or 4 only
    8000:incorrect action numberA blank space is not acceptable.
    can’t contain space
    8001:incorrect action number3 digits must be entered for this
    must be 3 digitsitem number.
    8002:incorrect entryThe item ars activity area specified
    does not exist
    is not valid.
    8100:action number out ofMust enter an ARS pattern before
    sequenceproceeding.
    must enter pattern
    number first
    8101:entry out of rangeTime for ARS subpattern must be in
    time data must be 4 digits
    the form HOUR, MINUTES
    [HHMM], military time.
    8102:entry out of rangeARS subpattern hours [HHMM]
    hours data can’t exceedcannot exceed 23.
    23
    8103:
    entry out of rangeARS subpattern minutes [HHMM]
    minutes data can’tcannot exceed 59.
    exceed 59
    8106:entry out of rangeARS FRL (Facility Restriction level)
    number must be 0-3must be between 0-3.
    8108:incorrect entryFacility access code (FAC) in ARS
    incorrect pool numberhas to be a valid pool number.
    8109:incorrect facility typeThe entered facility must be 4 digits.
    facility does not exist
    8110:facility type out of rangeA virtual facility access code must
    must be 190-199be between 190-199.
    F-26 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTION
    POSSIBLE SOLUTION
    8111:    incorrect entry           
    trunk pool does not exist
    Check the original trunk pool
    entered against the ARS trunk pool
    you are trying administer.
    8112:    action number out of  
    range
    number must be 0-1Only 1 and 0 are valid entries for 
    DDD overflow in ARS.
    8113:    inappropriate request 
    must install pool for this
    route memberMust administer an ARS FAC
    before trying to administer the FRL.
    8201:    inapproriate request
    incorrect patternThe pattern cannot be changed
    without a valid pattern display
    8202:    inappropriate request
    must enter pattern
    numberAn NPA was not entered before the
    pattern read.
    8203:    incorrect entry                    pattern digits incorrect or
    conflictingThe entered NPA is not valid
    8204;    entry out of range         
    pattern number must be 1
    digitPatterns are 1 digit only.
    8205:    entry out of range     
    pattern number must be
    1-8The pattern range is 1-8
    8300:    incorrect action number
    must be 401 or 402The only action items acceptable
    are 401 or 402
    8301:    entry out of range       
    access code can;t exceed
    4 digitsThe ARS access code cannot
    exceed 4 digits
    8302:    entry out of range       
    pattern must be 0-8The ARS international range is 0-8
    only.
    8400;    incorrect action number
    must be 0 unitl pattern
    entered.Must be 0 until you entered pattern.
    Can only enter Action 500 unitl list
    is entered.
    F-27 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    8402:entry out of rangeThe list number range is between
    list reference can’t1-4.
    exceed 4
    8403:entry out of rangeThe pattern range is 1-8 or 0 for
    must be 0-8 for removalremoval.
    8404:incorrect entryThe list cannot exceed 4.
    list reference can’t
    exceed 4
    8406:inappropriate requestAll information for the list was
    all members of list weredisplayed. There is no more
    displayedinformation in the list.
    8407:incorrect entry
    The entry must be 3 digits in which
    must be 3 digits - firstthe first digit cannot be a 0 or 1.
    can’t be 0 or 1
    8408:at installed maxHome NPA exception lists, 3-digit
    800 office codesoffice codes are divided among 4
    lists. Eight entries may be 7 digits.
    Max is 800 office codes
    8409:
    inappropriate requestThe office code is already entered
    office code exists-list 1
    in list 1.
    8410:inappropriate requestThe office code is already entered
    office code exists - list 2in list 2.
    8411:
    inappropriate requestThe office code is already entered
    office code exists-list 3
    in list 3.
    8412:inappropriate requestThe office code is already entered
    office code exists-list 4
    in list 4.
    8413:inappropriate requestThe office code was never installed,
    office code not installedso it cannot be removed.
    8414:
    inappropriate requestThe office code cannot be removed,
    office code exists-list 1
    its in list 1.
    8415:
    inappropriate requestThe office code cannot be removed,
    office code exists-list 2
    its in list 2.
    8416:inappropriate requestThe office code cannot be removed;
    office code exists-list 3
    it’s in list 3.
    8417:
    inappropriate requestThe office code cannot be removed;
    office code exists-list 4
    it’s in list 4.
    F-28 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    8418:entry out of rangeMENU = 11 (ARS) ACTlON = 501
    list member must be 1DATA = 1 digit value, 1-8 range.
    digit; value 1-8
    8419:inappropriate requestAll members of the list have already
    all members of list were
    been displayed.
    displayed
    8420:
    incorrect entryEntered number is not valid;
    first digit can’t be O-1 (7recheck number.
    digit max)
    8421:at installed maxInstalled maximum reached for
    -8 phone numberARS-HAC exception list.
    See: MENU =11 (ARS)
    ACTION = 512 and ACTION = 522
    ACTION = 822
    for more information.
    8422:inappropriate requestThe telephone number cannot be
    phone number exists-listinstalled; it already exists in list 1.
    1
    8423:inappropriate requestThe telephone number cannot be
    phone number exists-listinstalled; it already exists in list 2.
    2
    8424:inappropriate requestThe telephone number cannot be
    phone number exists-listinstalled; it already exists in list 3.
    3
    8425:inappropriate requestThe telephone number cannot be
    phone number exists-listinstalled; it already exists in list 4.
    4
    8426:inappropriate requestThe telephone number cannot be
    phone number notremoved because it was not
    installedinstalled in any lists.
    8427:inappropriate requestThe telephone number cannot be
    phone number exists-listremoved because it’s installed in list
    11.
    8428:inappropriate requestThe telephone number cannot be
    phone number exists-listremoved because it’s installed in list
    22.
    F-29 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    8429:inappropriate requestThe telephone number cannot be
    phone number exists-list
    removed because it’s installed in list
    33.
    8430:inappropriate requestThe telephone number cannot be
    phone number exists-list
    removed because it’s installed in list
    44.
    8501:incorrect entryThe entered telephone number is
    number can’t exceed 7not valid.
    digits
    8502:inappropriate requestThe telephone number is already in
    phone number already
    the list at another location.
    exists
    8503:incorrect entry
    Check character entry within phone
    illegal character withinnumber.
    phone number
    8600:incorrect action numberAction number must be in the range
    must be 0-5
    0-5.
    8601:inappropriate requestThe trunk pool must be specified
    must enter pool firstbefore actions 1-5 can be entered.
    8602:incorrect entryThe entered number was not
    pool number does nottranslated.
    exist
    8603:incorrect entryEntered number is not a trunk pool.
    must be pool number ,
    8604:incorrect entryEntered NPA is not valid.
    must be 3 digits-first
    can’t be 0 or 1
    8605:incorrect entryThe number of digits that are
    out of range for removalspecified to be removed at the
    beginning of the dialed number is
    not in range.
    8606:entry out of range
    A maximum of 5 digits can be
    prefixed digits can’tentered for the prefixed digits.
    exceed 5
    8607:entry out of rangeThe first prefixed digit cannot be 0.
    first digit can’t be 0
    F-30 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    8700:action number out ofMust enter pattern number first.
    sequence
    must enter pattern
    number first
    8701:incorrect action numberGo back and verify the action item
    does not exist or used
    taken.
    improperly
    8702:incorrect entry
    Pattern number for other area
    pattern number does notcodes exception numbers must be
    existbetween 1-8.
    See: MENU =11 (ARS) ACTION =
    800
    for more information.
    8703:entry out of rangeMust be 8 digits, first cannot be a O
    must be 8 digits -first
    or 1.
    can’t be O or 1
    See: MENU =11 (ARS) ACTION =
    822
    8704:entry out of rangeMust be 2 digits. The 2 digits must
    must be 2 digitsbe 
    						
    							APPENDIX F: Administration Error Messages
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    9003:
    inappropriate requestMENU =1 (Port) under Special
    station to be linked notFeature port.
    installedACTION = 1 DATA = 253
    ACTION = 2 DATA = PDC or 0
    In this case, the PDC is invalid or
    does not exist.
    9004:inappropriate requestTrying to administer an external
    station already assigned
    alert to a station that already has
    external alertone.
    9005:entry out of rangeMENU = 1 (PORT)
    pre-night service rings(under special Feature
    max reachedPorts/Auxiliary Equipment)
    ACTION = 1 DATA = 251 or 252
    ACTION= 2 DATA = 0-15
    9007:
    inappropriate request
    Check to see if selector console is
    selector console portalready installed.
    already installedGo to MENU = 8 Search
    ACTION = 1 DATA = 16
    ACTION = 2 DATA = 1602 or 1602
    ACTION = 3 DATA = 0
    (hit c for continue)
    9011:inappropriate request
    Selector console button already
    selector console buttonexists. Recheck selector console
    already existsbuttons that are already installed.
    9020:inappropriate requestRemoval of a station is disallowed if
    station is being queuedit is being queued for.
    for
    9021:inappropriate request
    Removal of a data port is
    data port is being queueddisallowed if it is being queued for.
    for
    9022:inappropriate request
    Removal of a trunk port is
    trunk is being queued fordisallowed if it is being queued for.
    9023:inappropriate requestRemoval of a DGC group is
    DGC group is beingdisallowed if it is being queued for.
    queued for
    9024:inappropriate request
    Removal of a trunk pool is
    trunk pool is beingdisallowed if it is being queued for.
    queued for
    F-32 
    						