    							APPENDIX E: Administration Codes and Data
    Table E-J.MET Set Button Defaults
    †Cannot be changed.
    E-22 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-K.PORT/PDC Administration, Data Terminals (Menu=12)
    ACTIONDESCRIPTlONDATA
    0Physical port numberCSSPP
    1Enter data type code[See Table E-K]
    2Enter DDC[1 -9999; 600-704]
    3Restrict dial access to CO trunk pool†[1=Y/0=N]
    4Restrict dial access to all other trunk[1=Y/0=N]
    pools†
    12DDC of station to hunt to next[PDC; 0 for none]
    13Restrict this stationfrom making[1=Y/0=N]
    outward calls†
    14Assign toll restriction class†[1-4; 0 for none]
    15Assign ARS Facility Restriction Level†[0-3; 3]
    21Enter associated voice/data endpoint[PDC/DDC or
    station*0 for none]
    22Restrict Third-Party Call Set-Up so user[1=Y/0=N]
    canonlyestablish calls for the
    associated station (see Action 21)†
    61Auto-adjustbaudrate oncall[1=Y/0=N]
    origination.*(The default is 0 for
    STARLAN CP.)
    62Allow terminal to operate at low bits[1=Y/0=N]
    per second (bps)*
    63Allow terminal to operate at a baud rate[1=Y/0=N]
    of 300 bps*
    64Allow terminal to operate at a baud rate
    [1=Y/0=N]
    of 1200 bps*
    65Allow terminal to operate at a baud rate[1=Y/0=N]
    of 2400 bps*
    66Allow terminal to operate at a baud rate[1=Y/0=N]
    of 4800 bps*I
    † If data port type code 1802 (STARLAN CP), default values are relevant for the first installed port
    on the board. Values assigned to this action item on 
    any of the four ports will be copied to all
    four ports on this board.
    ‡ Not administrable for STARLAN CP.
    lRead-only for STARLAN CP.
    E-23 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-K.PORT/PDC Administration,Data Terminals (Menu=1/2)
    (Contd)
    ACTIONDESCRIPTIONDATA
    67Allow terminal to operate at a baud rate[1=Y/0=N]
    of 9600 bps†
    68Allow terminal to operate at a baud rate[1=Y/0=N]
    of 19200 bps†
    69Assign this parity setting to correspond[0-3; 2]
    with terminal’s parity setting†
    0= Bit in parity
    position (no parity);
    1 =Bit in parity
    position (no parity)
    2=Even parity;
    3= Odd parity
    70Allow keyboard dialing/Command Mode†[1=Y/0=N]
    71Allow user configuration of data port[1=Y/0=N]
    parameters.† (The default is 0 for
    STARLAN CP.)
    72Allow mismatch of user’s data module[1=Y/0=N]
    and data port baud rate†
    73
    Allow characters dialed from keyboard[1=Y/0=N]
    to be echoed by the data port†
    74Enter your disconnect code†[1=2 short BREAKS/
    0=1 long BREAK]
    75Allow call progress text messages to be[1=Y/0=N]
    displayed on screen.†
    77Display connection indication message†[1=Y/0=N]
    90Assign/remove DDC Display ID[11 characters
    or less, or 
    to remove]
    † Read-only for STARLAN CP.
    E-24 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-L.Data Port Type Codes
    IF THE DATA PORT TYPE IS
    CODE:I
    (
    DataLineCard (DLC)1801
    functionality for ZTN126 or
    TN726
    STAR LAN Interface Circuit1802
    Pack (STARLAN CP) in
    DLC-compatibility mode
    Disable this individual port (for0
    any of the above data port
    types)
    E-25 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-M.Port Administration, Trunks (Menu=1)
    ACTION
    DESCRIPTIONDATA
    0Physical port numberCSSPP
    1
    Enter trunk port type code[See Table E-N]
    2Enter trunk number[0001 -9999;
    0001-0104]
    3Assign class-of-service code[(DID–1-4; 3)
    (All other—
    See Table E-O; 8)]
    4Assign pooled facility access code.[Facility access code;
    (100,101,102)
    O if trunk not in
    any group]
    5Allow dial access[l=Y/0=N]
    6Assign the trunk to a DGC group[1-32; 0 or none]
    7Make this a directed night service trunk[1 Y/0=N]
    8Assign night service delay announcement[1 for first
    announcement,
    2 for second
    announcement,
    O for none]
    9Type of signaling on incoming calls[1=Tone/0=Pulse]
    (Tie-Trunks only)
    10
    Determine pooled trunk hunting order of a
    specified trunk {Read Only}
    11For Switched Loop Attendant systems ONLY:[0-7; 0=won’t ring
    Priority of trunk to ring in queue†in queue/or
    1=highest priority,
    thru 7=lowest
    priority]
    Note: The TN747B CO Trunk port can be administered as either Ioop-start or ground-
    start, but not both at the same time. If a TN747B is administered before it is installed in
    a slot, the System 25 must be warm started before it will recognize the TN747B.
    †Not administrable for trunk port type codes 901-902 or 1003-1008.
    *Not administrable for trunk port type codes 901-902 or 1001-1008.
    E-26 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-M. PORT Administration, Trunks (Menu=1) (Contd)
    ACTION
    DESCRIPTlON
    DATA
    12For Switched Loop Attendant Systems
    [0-2; 0=either Att./
    ONLY; Which attendant should receive
    1=1st At. ONLY/
    calls from this trunk?†
    2=2nd Att. ONLY]
    13Specify Remote Access usage type‡
    [0-2; 0=name,
    1=shared, 2-dedicated]
    14Allow dial-access users to queue for this
    [1=Y/0=N]
    trunk?
    15Adjust Digital Tie Trunk gain for satellite
    [1 = satellite,
    > 15 msec round trip delay
    0= tandem]
    16For types 702 and 802 ONLY: Is this a
    [1=yes/0=no]
    paging port?
    17Identify trunk pool with Originating Line
    [0=[IXC+] O, O+, or
    Screening
    01N+ calls are not
    allowed from toll-
    restricted stations;
    [1=[IXC+] O, O+, or
    01 N+ calls are allowed
    from toll-restricted
    stations.
    30Special Signaling DS1 (LS, GS, OPS
    [0=foreign Exchange
    ONLY)
    (default), 1=Special
    Access Unit]
    40Special Signaling
    [0=FX (default);
    1=SAU]
    90Assign/remove trunk Display ID*
    11 characters or less,”
    or **to remove]
    For trunk port type codes:
    701, 702, 801, 802, 805: default is[FAC]
    “Outsiden
    901, 902: NOT ADMINISTRABLE
    1001-1008: default is “BRANCH”
    * Not administrable for trunk port type codes 901-902.
    November 1995E-27 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-N. Trunk Type Codes
    If the Trunk Type is:
    Code:
    Ground Start, CO701†
    Ground Start, WATS, FX702
    Ground Start, WPBX/Centrex705
    Loop Start, CO801†
    Loop Start, WATS, FX802
    PBX/Centrex805’
    DID Immediate Dial901
    DID Wink Start902†
    Auto-in/Auto out1001
    Auto-in/Immediate Dial-out1002
    Immediate Dial-in/Auto-out1003
    Immediate Dial-in/Immediate Dial-out1004
    Wink Dial-in/Auto-out1005
    Wink Dial-in/Wink Dial-out
    1006†
    Delay Dial-in/Auto-out1007
    Delay Dial-in/Delay Dial-out1008
    † Default Types.
    * Required for Centrex.
    E-28November 1995 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-O.Trunk Class-of-Service (for all trunks except DID)
    TRUNK CLASS-OF-SERVICE
    (FOR ALL TRUNKS EXCEPT DID)
    COSNIGHT
    OUTWARDINSHORT
    CODESERVICESIGNALINGONLYDISCONNECT
    0TT
    1TTl
    2TTl
    3TTll
    4DP
    5DPl
    6DPl
    7DPll
    8lTT
    9lTTl
    10lTTl
    11lTTll
    12lDP
    13lDPl
    14lDPl
    15lDPll
    TT=Touch-Tone
    DP=Dial-Pulse
    E-29 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-P.Port Administration, Auxiliary Equipment (Menu=1)
    ACTlON
    DESCRIPTlON
    DATA
    0Display physical port number, in the
    form CSSPP
    1Enter special feature port type code
    (see Table E-Q).
    1Assign external alerts
    [253]
    2Assign associated station number
    [PDC of associated
    station; 0 if night
    service alert]
    1Assign paging Interface (associated
    [1301-1303]
    with auxiliary trunk circuit)
    2Assign PDC for this zone
    [PDC (zone 1)
    PDC (zone 2)
    PDC (zone 3)
    0 for none]
    3Assign all-zone PDC
    [PDC for all-zone,
    0 for none]
    4Dial restrict this zone (1=YES/0=NO)
    [1/0]
    1Assign DGC delay announcement
    [255]
    2Assign PDC
    [unique PDC]
    3Restrict Dial Access
    [1=yes,
    0=no]
    90Assign ID
    [1=yes,
    0=no]
    1Assign directed night service delay
    [251 (delay
    announcement
    announcement
    #1); 252 (delay
    announcement
    #2)]
    2Assign number of rings before delay
    [0-15]
    announcement
    1Assign music-on-hold source
    254
    2Assign music-on-hold for Special Hold?
    [1=Yes/0=No]
    E-30 
    						
    							APPENDIX E: Administration Codes and Data
    Table E-P. Port Administration, Auxiliary Equipment (Menu-1 ) (Contd)
    ACTION
    DESCRIPTlONDATA
    1Assign voice Messaging Service port[260 - 263]
    type:
    260 =standard voice mail services
    261 =call coverage/auto-attendant
    262 =message drop
    263 =
    bulletin board
    2
    Assign PD for this VMS port
    [PD.]
    3Restrict dial access to the CO trunk pool
    [1=Y/0=N]
    4Restrict dial access to all other trunk[1=Y/0=N]
    pools
    5Make this VMS port dial-accessible
    [1=Y/0=N]
    10Make this VMS port an extended station†
    [1=Y/0=N]
    13Restrict this station from making any
    [1=Y/0=N]
    outside calls
    14Assign a toll restriction class
    [0-4]
    15Assign an ARS Facility Restriction Level
    [0-3]
    90Assign/Remove VMS port Display ID[11 characters or less,”
    or** to remove]
    1Assign pooled modem[1901]
    1Assign additional tone detector
    [2101]
    1Assign dial dictation[2201 (if auxiliary trunk
    interface); 201 (if
    station port interface)]
    2
    Assign dial dictation PD.[PD.]
    1Assign selector console[1 601 or 1602]
    21-27 Assign the hundreds group to this button
    † For TN742/TN746 ports only. Use the default value for extended stations in order to meet
    FCC compliance for level of dial tone.
    November 1995
    E-31 
    						