    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    DCFailTransientRecord:No action required; this error
    Indicates a dc power failure.display is a record of the start
    time of the failure.
    DC Power Failed: Indicates theCheck the +5 V dc voltage level
    absence of +5 V dc on a cabinet.on the power supply (see Figure
    Each cabinet has its own power4-2).
    supply; therefore, this may not
    cause a warm start.
    DC Power Restored:IndicatesIt is possible to produce this error
    that +5 V dc has been restored.when a CP is inserted into a slot
    The“DC Fail Check”log iswith power “On” (not a real
    removed. This message keeps aProblem).
    record of dc “hits.”
    Down Link Buffer Overflow: TheRecoverable; no action required.
    down-linkbuffer isreceiving
    messages too fast.
    DSP Insane:Service Circuit orIf a  DSP Sane  occurred, the
    Tone Detector CP problem.
    system will remove this error from
    the permanent alarm table. If the
    problempersists,check or
    replace the faulty CP.
    DSP Sane: DSP recovered fromRecoverable; no action required.
    an insane condition.
    Dual Port RAM Read-Back Failure:Check CP, and replace if required.
    Service Circuit dual port RAM
    problem.
    WART Test Failed:PeripheralThis problem affects the tape,
    port on CPU/Memory CP hasadministration,maintenance and
    failed.
    SMDR ports.If the problem
    persists, replace the CPU/Memory
    CP. 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    DXS Reset; The DXS console hasRecoverable; no action required.
    been reset.
    ElectronicPowerFeed Off,
    Check the wiring for shorts from
    Overcurrent:A Hybrid
    Linethe backplane/SIP up to the
    (ZTN79) port EPF chip shut down.phone jack. Check the ATL set at
    Two ports are effected, for
    the SIP. Try swapping ATL sets.
    example, 1-2,3-4,5-6,7-8.
    Error removed if Audit passed and
    short removed. Audit runs every 4
    minutes.
    Electronic Power Feed Overload:Check the tie trunk pairs from the
    A Tie Trunk (TN760B) port EPL
    back of the cabinet through to the
    chip went into overload.network for an external short (see
    Figure 4-4). If the short is not
    detected on the pairs, replace the
    board.
    Electronic PowerFeed Test
    Check the E and M leads for
    Overload: The “M” lead on a tieexternal shorts (see Figure 4-4). If
    trunk has an external short circuit.the short is not on the pairs,
    replace the board.
    Empty CSMA Queue: (STAR LANIf the reset is not successful
    Interface CP) This error resets thereseat board. If the reseat fails,
    CP.
    replace the CP.
    Error Log Table Full: TransientCorrect indicated errors, and then
    Error Log is full.remove entries from the Transient
    Error Log to free-up space.
    External RAM Failure: Port orReseat board. If problem persists,
    CPU/Memory CP error whilecheck or replace appropriate CP.
    runningbackgroundnon-
    destructive external RAM tests.
    4-36 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    External Stack Full: (STARLANIf the reset is not successful
    Interface CP) This error resets thereseat board. If the reseat fails,
    CP.
    replace the board.
    Fault onOutgoingSeizure:
    Check trunk for slow dial tone;
    ZTN76/TN747 CO ground was notmore than 10 seconds. Perform
    detected within a predeterminedtrunktestcall
    per“Trunk
    time-frame.ZTN77/747loopTroubles”procedure in this
    current was not detected within asection.If the problem persists,
    predetermined time frame.see Figure 4-3.
    Frame Length Error: (STAR LANRecoverable; no action required.
    Interface CP) Packet length too
    long for ZTN84.
    .
    Generator DSP Insane: ServiceIf a
    “Generator DSP Sane”
    Circuit problem.occurred, the system will remove
    this error from the permanent
    alarm table.If the problem
    persists, check or replace the
    faulty CP.
    Generator DSP Sane:ServiceRecoverable; no action required.
    Circuit recovered from insane
    condition.
    Ground But No Ringing: TheIncoming calls are okay. The
    switch does not detect ringingproblem could exist at the CO,
    from the CO within 5 seconds ofbad ringing generator or a bad
    Tip ground on an incoming groundring detector on the board. The
    start call.Tip lead could be getting ground
    hits. Perform a trunk test call per
    “Trunk Troubles”
    procedure in
    this section.
    4-37 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    Illegal Instruction: This error isThe Problem could be with the
    logged when an illegal instructionROM on the CPU/Memory CP. If
    is encountered by the CPU.the problem persists, check or
    replace CP.
    Illegal Interrupt: CPU/Memory CPThe CP may still pass the power-
    problem.up test for the ROM. Check or
    replace the CPU/Memory CF.
    Illegal Port Command: (STARLANRecoverable; no action required.
    Interface CP) This error is an
    isolated transient condition.
    Illegal Port Interrupt: (STAR LANNormally, this is a isolated
    Interface CP) This error is antransientcondition
    thatis
    isolated transient condition.recoverable; however, if problem
    occurstoofrequently, a
    permanentalarmwill be
    generated.If problem persists,
    check or replace CP.
    Internal RAM Failure: Port CPCheck port CF.
    error while running background
    non-destructiveinternalRAM
    tests.
    InternalSanityTimeout:If the reset is not successful,
    (STARLAN Interface CP) Thisreseat board. If the reseat fails,
    error resets the CP.replace the CP.
    Invalid Board Message: The portIf the problem persists, check or
    CP sent an up-link message thatreplace the port CP.
    is not in the expected message
    set.
    4-38 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTION
    POSSIBLE SOLUTION
    Invalid Message Length: The portIf the problem persists, check or
    CP sent an up-link message that
    replace the port CP.
    is not in the expected message
    set.
    Invalid Port Board:(Other thanRemove or replace CP with a
    CPU or Memory) Port CP not
    board that is supported by System
    supported by system.25.
    Invalid Port Message: The port
    If problem persists, check or
    CP sent an up-link message that
    replace the port CP.
    is not in the expected message
    set.
    LAN 
    Protocol Error:(STARLANSystem will normally recover;
    Interface CP) This error may behowever, if the problem persists,
    caused by a defective endpoint on
    a defective endpoint may exist on
    the STARLAN NETWORK.
    the STARLAN NETWORK (see
    Figure 4-5).
    Limited Default Cold Start: This isConnectSAT and
    translate
    a cold start after which only asystem.Perform
    “Restore
    limited
    amount ofdefaultSystem” procedure listed in the
    translations have been made. TheAdministration Manual.
    CPU/Memory, Service Circuit, and
    Tone Detector are the only CPs
    initialized.
    Memory Management Corruption:If problem persists, check or
    Software audit determined andreplace CPU/Memory CP.
    corrected memory management.
    4-39 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    Memory Management Error: BusPossible
    software
    error.If
    error that occurs while accessingproblem
    persists,check or
    the “other than protected” RAM.replace CPU/Memory CP. A
    A warm start is logged after thiswarm start or retranslation of the
    error.
    system could be a possible fix for
    this problem.
    Memory ROM Checksum Error:If this problem persists, replace
    Memory has failed the ROM test.CPU/Memory CP.
    Message Corruption: (Other thanIf consistent error for particular
    CPU/Memory)Down-link
    port CP, check TDM bus drivers
    message checksum error.on the CP. If error is associated
    with many CPs, drivers on CPU
    may be bad.Also check 1/O
    cables and TDM bus terminator.
    MessageFrom Non-TranslatedTranslate the CP and its port, or
    Port: Untranslated port CP sentremove the CP from system.
    an up-link message.
    No External Release On PBXCheck associated trunk(see
    Disconnect:CO did not releaseFigure 4-4). Error is cleared from
    within 4-5 minutes on DID orlog when trunk release occurs
    ground start trunk after System 25belatedly.
    disconnected.Messagesent
    every 4-5 minutes until release.
    NoFreeBuffer:
    (STARLANIf the reset is not successful,
    Interface CP) This error resets thereseat board. If the reseat fails,
    CP.replace CP.
    No Loop Current On Incoming
    Swap CP with similar CP. If
    Call:CP does not detect dcproblem follows the boards,
    current on answered incomingreplace CP. If problem persists,
    call. Call will drop.
    test the trunk per Figure 4-3. 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    On-HookBeforeReady To Receive
    Digits: For a tie trunk with delay
    dial or winkstart—after the
    handshake is complete, a 50-ms
    guard time must pass before
    digits are received. If the far-end
    goes on-hook before guard time
    elapses, this message is logged.
    On-Hook Before Wink: For a tie
    trunk with delay dial or wink
    start—if the far end goes on-hook
    (possibly indicating the beginning
    of a rotary dial digit) before the
    wink handshake is completed, the
    error is logged.A disconnect
    sequence is started, and the call
    may be dropped.
    Recoverable; no action required.
    If this problem persists, check the
    tie trunk configuration (see Figure
    4-6).
    On-Hook During Wink: This error
    indicates that digits are being sent
    by the far end before the switch is
    ready to receive them.The two switches are probably notcompatible.Checkthe
    configuration of each switch.
    PhysicalandLogicalType
    Mismatch: (Other than CPU or
    Memory) Port CP plugged into
    wrong slot.
    Port CP in Unadministered Slot:
    (Other than CPU/Memory) Port CP
    inserted into a slot that is not
    translated or CP inserted into
    wrong slot.Change translations to reflect the
    new CP, or install the proper CP.
    Translate slot, or remove CP. If
    CP is in the wrong slot remove
    and install CP into proper location.
    4-41 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    Port CPMissingButCheck CP slot; reseat CP; change
    “Administered:(OtherthanCP; orremoveCP
    from
    CPU/Memory) Translated port CPtranslations. If CP does not pass
    that CPU cannot access.power-up, replace CP.
    Port CP Out Of Service:
    (OtherIf the CP has not been removed
    thanCPU/Memory)Messageand the problem persists, check
    occurs when a CP is removed
    or replace the port CP.
    from a cabinet. Error removed
    when the CP passes power-up.
    Port CP ROM Checksum Failure:Try reseating the CP. If this error
    The port CP has found that thehappens again, then replace the
    checksum on its firmware is bad.CP.
    Port Buffer Full:
    (STARLANIf the reset is not successful,
    Interface CP) This error resets thereseat CP. If the reseat fails,
    CP.replace the CP.
    Port Fault: For an auxiliary trunk,Checkwiring of
    external
    this message is logged when aequipment (see Figure 4-7).
    ground is expected from external
    equipment and is not detected.
    Port Queue Full:
    (STARLANIf the reset is not successful,
    Interface CP) This error resets thereseat CP. If the reseat fails,
    CP.replace the CP.
    Program
    LogicInconsistent:Reseat CP. If problem persists,
    (OtherthanCPU/Memory)replace it.
    Possible hardware problem on
    port CP.
    RAM Test Failed: CPU/MemoryCheck CPU/Memory CP.
    CP has failed the RAM test.
    4-42 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    Received Incorrect Number of
    DID Digits:
    This error indicates
    that the CO is set up to send a
    number of DID digits different
    from what the switch has been
    administered to receive.Ensure that trunks are properlytranslated.Notify local CO to
    verify the correct number of digits
    to be sent. Test trunk per Figure
    4-3.
    RIMS Insane:Service Circuit or
    Tone Detector CP problem.If an “RIMS Sane” occurred, the
    system will remove this error from
    the permanent alarm table. If the
    problem
    persists,check or
    replace the faulty CP.
    RIMS Sane: RIMS recovered fromRecoverable; no action required.
    an insane condition.
    ROM
    ChecksumFailure:
    CPU/Memory CP ROM checksum
    test has failed.If the problem persists, check orreplace the CPU/Memory CP.
    Ringing Without Ground: Ground
    was not detected from CO within
    5 seconds from the time ringing
    starts.Check Tip/Ring for possible
    reversal.
    Service Circuit In Mismatched
    slot:Service Circuit in slot
    translated for other type CP; two
    ServiceCircuitsmountedin
    cabinet. Only one Service Circuit
    (ZTN85 or ZTN131 [R3]) allowed
    persystem.Additional
    tone
    detection available using Tone
    Detector CP (TN748).Ensure that only one ZTN85 or
    ZTN131 (R3) is in the system. If
    there are others, remove them.
    Also make sure that the ZTN85 or
    ZTN131 (R3) is in it’s translated
    slot.
    4-43 
    						
    							MAINTENANCE
    ERROR MESSAGE
    AND DESCRIPTIONPOSSIBLE SOLUTION
    ServiceCircuitTestFailed:
    Check TDM bus terminator and
    Service Circuit demand test failedcabinet interconnect cables. If the
    on the DTMF receivers.problem persists, replace ZTN85
    or ZTN131 (R3).
    Signaling Lead Fault: AuxiliaryCheckwiring of
    external
    Trunk CP is expecting a groundequipment per Figure 4-7.
    from external equipment but none
    is detected.
    SlotConfigurationError:This condition can be resolved by
    (STARLAN Interface CP) Thismoving the ZTN84 port CP to
    error means that another ZTN84another slot in the carrier.
    port CP is on the STARLAN
    NETWORK and has the same
    physical address.
    System Lock-Up: This error isUsually, noactionrequired;
    logged by the task supervisor if,however if
    problem persists,
    during scheduling of tasks, noreplace CPU/Memory CP.
    messages have been read for at
    least 60 seconds. This causes a
    restart of the system.
    System Restart: System lockedCheck the power supply voltages
    up in a software task. The “Portper Figure 4-2. If problem persist,
    Number” entry in the log is thethe CPU/Memory CP could be
    task at fault.defective.
    Translation Memory Test Failed:Check if Cold Start error has
    Memory translation checksum testoccurred.Reload
    translations
    failed.from tape per the procedure in
    Administration Manual. If the
    problempersists,
    check or
    replace CPU/Memory CP. 
    						