Trillium Standard Practice To MDF stations: 24 Vdc Battery AC Power Backup s _~lllli~lllllllllllllllll~ll 4 0 IIIIIIIIIIIIIIIIIIIIIIIII IIbdhn -18to25 KEY Background Music Music on Hold AmDlifier I Feature Module Cartridge e Power Fail Station M:yge I rl . Answer Door Unit Module Dl 02 DA Incoming - $%xBW Lines (1 -8) !53 Printer / Terminal Figure 6-l (a) Panther II 820 Main Configuration Installation and Commissioning Page 12
![](/img/blank.gif)
Panther II 820/1032/2064-200 A a T 24 Vdc Battery AC Power Backup To MDF stations: Back round Music Music on Hold I Feature Module Cartridge II Door III III Station MreTtt Recorder Connect to Panther 2064 Cabinet or connect to 6 C.O. Line Module, if applicable I Incoming C.O./PBW Centrex Lines (1 - 10) II I I 557 To Printer/Terminal Figure 6-l(b) Panther II 1032 Main Configuration Installation and Commissioning Page 13
![](/img/blank.gif)
Trillium Standard Practice To MDF stations: AC Pnwer 24 Vdc Battery L’ I Backup , ._ . __._. I ~lllllllllllllllllllli L KEY SEURNL;FE Power Fail Connect to Panther 1032 Cabinet 1 I= -ill Incoming C.O./PBX/ Centrex Lines (11 -20) Figure 6-l(c) Panther II 2064 Main Configuration Installation and Commissioning Page 14
![](/img/blank.gif)
Panther II 820/1032/2064-200 Mounting System Components 6.0 4 The following instructions detail the installation of the KSU. The installation procedure is similar for any ancillary devices included in the system, only the location of the mounting screws may differ. This can be seen in Figures 6-2 to 6-6. Step 1. Using suitable fasteners, mount a wooden backboard, of sufficient size to accommodate the KSU and ancillaq devices (if any), to the wall, within 4 feet of the ac outlet and at least 12 inches (305 mm) above the floor. Allow room for installation of the ancillary devices which may be installed at a later date. Step 2. Position the KSU on the backboard. Mark the positions of the KSU’s four mounting screws on the backboard. Step 3. Install the mounting screws supplied, into the backboard, leaving approximately an 0.2 inch (5 mm) gap between the back of the screw head and the backboard. Step 4. Hang the KSU on the mounting screws. Tighten the mounting screws. Caution: Do not connect the KSU power cord until instructed to do so. I Step 5. Repeat Steps 1 through 4 for each of the ancillary devices to be installed. Installing the Feature Module Cartridge 6.0 5 Panther II 820 and 1032 Key Service Units have a Feature Module Cartridge that contains the software for the Panther II features. Step 1. Unpack the Feature Module Cartridge. An information sheet packed with the Feature Module Cartridge provides an installation diagram. Step 2. There are two small grooves on the Feature Module Cartridge connector. Holding the Feature Module Cartridge so that the grooves are facing you, plug it into the port that is located halfway down the right-hand side of the KSU. Step 3. Place the protective cover over the Feature Module Cartridge, push in the plastic expander plugs, and tighten the two screws. Installation and Commissioning Page 15
![](/img/blank.gif)
Panther II 820/1032/2064-200 t 17.8 cm (7 inch) 14.9 cm (5.875 inch) Wooden Backboard Door / Answer Unit Figure 6-3 Door Answer Unit Wall Mounting Installation and Commissioning Page 17
![](/img/blank.gif)
Trillium Standard Practice --. 7.9 cm (3.125 inch) -1 Wooden 8.9 cm (3.5 inch) Power Fail Transfer Unit Figure 6-4 Power Fail Transfer Unit Wall Mounting Installation and Commissioning Page 18
![](/img/blank.gif)
Panther II 820/1032/2064-200 7.9 cm ( 3.11 inch) r-7 Wooden t n 1- -. -. . . -. Station Message Detail Recording Unit J Ull (3.56 inch) Figure 6 -5 SMDR Unit Wall Mounting Connect The Equipment To Ground 6.0 6 The KSU must be connected to ground through a single solid conductor. Caution: DO NOT rely on the third wire (Green) of the AC cord to connect the KSU to ground. A separate external ground lead must be connected. Installation and Commissioning Page 19
![](/img/blank.gif)
Panther II 820/1032/2064-200 Step 2. When the system comprises a 2064 KSU, repeat Step 1 for CO. lines 11 through 20. When a second Door Answering Unit forms part of the system configuration, do not connect C.O. line 20. Line Lead Designation Conductor Color MDF Terminal RJ21 Pin Number 1 Tip White-Blue 1 26 Ring Blue-White 2 1 2 Tip White-Orange 3 27 Ring Orange-White 4 2 3 Tip White-Green 5 28 Ring Green-White 6 3 4 Tip White-Brown 7 29 Ring Brown-White 8 4 5 Tip White-Slate 9 30 Ring Slate-White 10 5 6 Tip Red-Blue 11 31 Ring Blue-Red 12 6 7 Tip Red-Orange 13 32 Ring Orange-Red 14 7 8 Tip Red-Green 15 33 Ring Green-Red 16 8 9 Tip Red-Brown 17 34 Ring Brown-Red 18 9 10 Tip Red-Slate 19 35 Ring Slate-Red 20 10 DO NOT connect line 8 if the Door Answer Unit is being installed on the Panther II 820 system. DO NOT connect line 10 if the Door Answer Unit is being installed on the Panther II IO32 system. *Not required for the Panther II 820 system. Table 6-l Pin-to-Pin Designations (for Panther II 820/1032 KSU) (RJ21X Connector) Installation and Commissioning Page 21