Trillium Standard Piactice ,’ They are: . The Panther 306 Non-Handsfree (NHF) Telephone Set . The Panther’306 Handsfree/ Busy Lamp Field (HF/BLF) Telephone Set l The Panther 612 Standard Telephone Set . The Panther 612 Attendant (HF/BLF) Telephone Set l The Panther 1032 NHF Telephone Set l The Panther 1032 HF Telephone Set l The Panther 2064 NHF Telephone Set l The Panther 2064 HF Telephone Set l The Panther II Display Set (Available only on Panther II) . The Panther II Set (Available only on Panther II - may be referred to as Basic Set). 2.03 In addition to the 10 types of sets, there are also two types of Direct Station Selection / Busy Lamp Field (DSWBLF) Consoles, which allow visual monitocng of all other Panther Sets in the system. The Panther 1032 DSWBLF Console provld.es 32- station indicator lamps, and the Panther 2064 DSWBLF Console provides 64-station indicator lamps. Each of the consoles occupy one station in the system. 2.0 4 The differences between the Panther Telephone sets are clearly defined in Panther II 820/I 03212064-I 00, General Information. Installation and Commissioning Page 2
Pant her II 820/l 032/2064-200 TOP AC Power Cord Ground Terminal AMP Connector 37.6 cm (14.8 inch) 34.5 cm (13.6 inch) I llllIIIlllllIIIIlllllIIIIIIIIIIIIII I 6.9 cm .75 inch) . I I- lllll NIlI II L BOTTOM Figure 2-1 Key Service Unit Dimensions 42.7 cm (16.8 inch) RIGHT Installation and Commissioning Page 3
Trillium Standard Practice Ringer Volume Handset Jack 10.7 cm (4.2 inch) 17.8 cm (7 inch) 23.9 cm (9.4 inch) Figure 2-2 Panther Telephone Set Dimensions 3. EQUIPMENT IDENTIFICATION General 3.0 1 The major components of the Panther II systems are identified by a part number normally located on the right-hand side of the KSU and on the bottom of the Panther ) telephone sets. Part Numbers 3.0 2 The part numbers of field-replaceable items are given in Table 3-l(a) and Table 3-l(b). Installation and Commissioning Page 4
Panther II 820/1032/2064-200 PANTHER II 1032: 1032 KSU Non Handsfree (NHF) Set Handsfree (HF) Set 1032 DSS/BLF Console PANTHER II 2064: 90-0466 go-0320 go-0421 go-031 2 2064 KSU 2064 Non Handsfree (NHF) Set 2064 Handsfree HF Set 2064 DSS/BLF Console PANTHER II 820: 90-0468 90-0288 go-0225 90-0226 820 KSU 90-0465 ADDITIONAL SETS: 306 NHF Set 306 HF/BLF Set 612 Standard Set 612 Attendant Set (HF/BLF Set) Panther II Display Set Panther II Set (Basic Set) ANCILLARY DEVICES: go-0291 go-0292 90-0266 90-0168 90-0469 go-0470 Panther I I SMDR go-0471 Desk/Wail Mount 90-0059 Door Answer Unit go-0057 Door Module 90-0058 Power Fail Transfer Off-Premises Extension Unit go-0052 90-0308 FAX Interface Unit go-0472 6-Line Expander Unit 90-0467 Table 3-l(a) System Components Installation and Commissioning Page 5
Trillium Standard Practice PANTHER 11 306 SETS: Plastic Lens - Set Plastic Lens - BLF Set Designation Card - Set . Pk of IO Designation Card - BLF Set, Pk of 10 Designation Card - Set (French) Pk of 10 Designation Card - BLF Set (French) Pk of 10 Line Key Overlay Line Key Overlay (French) PANTHER II 6 12 SETS: Plastic Lens - Set Plastic Lens - BLF Set Designation Card - Set, Pk of 10 Designation Card - BLF Set, Pk of 10 Designation Card - Set (French) Pk of IO Designatiol’;Card - BLF Set (French) Pk of 10 Line Key Overlay Line Key Overlay (French) ALL PANTHER II SETS: Handset Cord - Coiled. 7ft, 4 Conductor Handset Cord - Coiled, 14ft, 4 Conductor Handset, Hearing Aid Compatible (box of 10) Modular Cord - 4 conductor Connecting Cord - PFT Unit Rubber Feet - Telephone Base (Pk of 100) PANTHER II 1032 SETS: Plastic Lens - Set Plastic Lens - BLF Set Designation Card - Set, 10 Pk Designation Card - Attendant Set , 10 Pk Designation Card - DSS/BLF 10 Pk Designation Card - Set (French) 10 Pk Designation Card - Attendant (French) 10 Pk Designation Card - 1032 (on 2064) Set 10 Pk Line Key Overlay Panther 1032 or 2064 (French) PANTHER II 2064 SETS: Plastic Lens - Set Designation Card - Set , Pk of 10 Designation Card - DSS/BLF Set, Pk of 10 Designation Card - Set (French) Pk of 10 PANTHER II DISPLAY SET Plastic Lens - Set Designation Card - Set , 10 Pk Designation Card - Set (French) 10 Pk . LCDLabel Designation Card - (Blank) IO Pk Designation Card - (Blank) (French) 10 Pk Keypad Overlay (French) PANTHER II SET - (BASIC SET) Plastic Lens - Set Keypad Overlay (French) Designation Card - Set , 10 Pk Designation Card - Set (French) 10 Pk Designation Card - Set (Blank) 10 Pk Designation Card - Set (Blank) (French) 10 Pk OTHER BLANK DESIGNATION CARDS Panther 306 BLF Set - 10 Pk Panther 306 Set - 10 Pk Panther 612 Set - 10 Pk Panther 612 Attendant Set - 10 Pk 70-02 11 70-02 12 90-0296 go-0297 90-0298 90-0299 77-0349 77-0350 70-0171 70-0172 90-0192 90-0193 90-0191 go-0194 77-0254 77-0255 69-0048 69-0049 90-0233 69-0030 69-0050 90-0133 70-0208 70-0209 90-0258 90-0306 90-0259 90-0268 90-03 10 90-0414 77-037 1 70-0210 90-0300 90-0301 90-0302 70-0293 90-048 1 90-0482 77-0602 90-0483 90-0484 77-0603 70-0294 77-0609 90-0485 90-0486 90-0487 90-0488 90-0407 90-0408 90-0409 90-0410 Table 3-l(b) Spare Parts Installation and Commissioning Page 6
Panther II 820/1032/2064-200 4. EQUIPMENT CONFIGURATION 4.0 1 The basic equipment configuration for each Panther II 820 system is one 820 Key Service Unit, and up to 20 Panther telephone sets. The Panther II 1032 system is made up of one 1032 Key Service Unit, and up to 32 Panther telephone sets. The Panther II 2064 requires two Key Service Units and up to 64 Panther telephone sets. The two KSUs making up the Panther II 2064 system are: l a 1032 KSU which acts as the main control centre for the system and accommodates the frost 10 lines and 32 stations l a 2064 KSU which allows expansion of the system up to 20 lines and 64 stations. In addition, each system may be configured with the following ancillary devices: l Door Answer Unit, supporting a maximum of 2 Door Modules. For a general description of the Door Answer Unit refer to Panther II 820/1032/2064- 290, Door Answer Unit. l Power Fail Transfer Unit. For a general description of the Power Fail Transfer Unit refer to Panther II 82OfIO32/2064-291, Power Fail Transfer Unit. l Station Message Detail Recording Unit. For a general description of the Station Message Detail Recording Unit, refer to Panther II 820/1032/2064-292, Station Message Detail Recording Unit. 5. INSTALLATION REQUIREMENTS Space Requirements 5.0 1 It is recommended that the KSU be wall mounted on a wooden backboard. The thickness of the backboard should be 20 mm (0.75 inch) to accommodate the KSU mounting screws. The area of the backboard should be sufficient to accommodate the KSU, the Main Distribution Frame (MDF) connection block and any ancillary devices which form part of the system. The KSU alone requires clearance of 12 inches around its perimeter to facilitate installation, maintenance and ventilation. See Figure 5-1. In addition, the KSU should be mounted at least 12 inches (305 mm) above the floor. Temperature 5.0 2 The Panther II KSUs can be installed in a location which complies with the following temperature and humidity constraints. l Temperature: 32 degrees Fahrenheit to 104 degrees Fahrenheit (0 degrees Centigrade to 40 degrees Centigrade). l Humidty: 90% or less, non-condensing. Installation and Commissioning Page 7
Trillium Standard Practice Figure 5-l KSU Space Requirements KSU Location 5.0 3 The KSU should be mounted in a location which: l is clean, dry and well ventilated. l provides access to the incoming C.O. lines. l is equipped with a grounded 110 Volt ac electrical outlet. l provides an earth ground (an all metal cold water pipe is ideal) 5.0 4 The position of the KSU in relation to the other equipment must be chosen so as to ensure maximum cable lengths from the Main Distribution Frame (MDF), and from the stations are not exceeded. Installation and Commissioning Page 8
Panther II 820/1032/2064-200 The maximum cable lengths are: l KSU to MDF - should not exceed 25 feet. l KSU to stations should not exceed the following: - 2000 feet using 24 AWG cable Power Supply Requirements 5.05 The power for the Panther II systems must be supplied from a 110 Vat, 15 Amp, mains commercial power supply. It is recommended that the supply be: l wired and fused independently from all other power receptacles. l controlled directly from the circuit breaker and not from a local switch. l located within 4 feet of the KSU. l easily accessible for removal of the plug, if required. l equipped with a surge protector to reduce the likelihood of damage to the equipment in the event of a lightning strike (Recommended Supplier: ITW LINK, Elk Grove Village, Illinois - # LP3-230-220 for C.O. Lines; # LP3-90-30 for each station pair). Grounding 5.0 6 The KSU must be connected to a ‘high quality’ ground through a separate single, solid conductor (12-gauge), terminated on the Ground Terminal on the top panel of the KSU. requirements: The ground connection for the KSU should comply with the following l The current, as measured between the Ring side of a C.O. Line and the ground source, should equal at least twice the short circuit loop current, measured between the Tip and Ring of that C.O. line. See Figure 5-2. l The 12 AWG ground cable should not exceed 18 inches in length. l The ground cable should be a continuous solid conductor having a total resistance of less than 0.5 ohms when measured between its point of origin (i.e., the ground source} and the Ground Terminal on the KSU. Note: Failure to properly ground the KSU may cause system failure. -1 Installation and Commissioning Page 9
Trillium Standard Practice Ground Source x --- m C.O. Line I I ’ Short Circuit u--._ Ring Loop Current Ampmeter (DC) *I I* 41 x = reading in milliamps Measure -_-___________. Current on Ring side of line C.O. Line Tip m Ring _--- -N I ’ Figure 5-2 Ground Verifi’cation Installation Tools and Equipment 5.07 The tools and equipment required to instaN the Panther II systems are shown in Table 5- 1, Installation and Commissioning Page 10
Panther II 820/1032/2064-200 TOOLS: Screwdrivers Punch Down Tool Staple Gun EQUIPMENT: APPLICATION: Mounting major components Terminating MDF cables Securing cables Modular Jacks Connecting Stations 50-pin ‘D’ Amp Connector KSU to MDF Cable termination MDF (BIX or 66 Block) Main Distribution Frame Surge Protector Lightning protection at mains ac Ground Wire (12 AWG) Grounding the KSU Modular-to-Modular Cords Equipment interconnection 4-wire Cable (24 AWG) Station wiring Table 5-l Installation Tools and Equipment 6. INSTALLATION PROCEDURES General 6.0 1 The installation procedures given in this subsection detail the installation of the major components of the Panther II 820, 1032 and 2064 systems along with the ancillary devices which may be incorporated. The interconnection of the complete system and its anciliary devices is shown in Figure 6-l. Delivery Check 6.0 2 Upon receipt of the Panther II system, the quantity and type of items received, should be checked against the purchase order. Any discrepancy should be reported to the supplier immediately. Unpacking and Inspection 6.0 3 After the delivery check is complete, each item of equipment should be unpacked, in accordance with the unpacking instructions located on the outside of the equipment boxes, and inspected for transit damage. Any discrepancy should be reported to the supplier_immediately. Installation and Commissioning Page 11