System & Station Program 77-3 – Night Ringing Over PIOU External Page Zones Strata DK System Record Sheets 5/9997 System & Station Program 77-3 – Night Ringing Over PIOU External Page Zones Processor Type:DK40i, All RCTUs Program Type:System Initialized Default:Zones 1~4 assigned to tenant 1 6SNU +ROG 6SNU +ROG 6SNU+ROG 6SNU+ROG TenantZone 1Zone 2Zone 3Zone 4 Tenant 1 CO Lines Tenant 2 CO Lines Tenant 3 CO Lines Tenant 4 CO Lines Enter the tenant (1~4) to be assigned with the zone entered in the preceding step. These assignments apply to ground and loop start lines only; they do not apply to DID and Tie lines. SELECT = 3 Enter a PIOU external page zone relay (1~4).
![](/img/blank.gif)
System & Station Program 77-4 – RSIU Open Architecture Interface (OAI) Data Output Assignments 98Strata DK System Record Sheets 5/99 Program 77-4 – RSIU Open Architecture Interface (OAI) Data Output Assignments Processor Type:All RCTUs (Release 3.2 and above) Program Type:System Initialized Default:All LEDs are OFF 6SNU +ROG 6SNU +ROG 6SNU+ROG 6SNU+ROG LED/ ButtonXLED ONLED OFF 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 04 03 02DNIS Number will be sent from OAI port DNIS Number will not be sent from OAI port 01Caller ID/ANI will be sent from OAI port Caller ID/ANI will not be sent from OAI port Light the LED Buttons that are marked with an X in the table below.SELECT = 4
![](/img/blank.gif)
System & Station Program 78 – CO Line Special Ringing Assignments Strata DK System Record Sheets 5/9999 System & Station Program 78 – CO Line Special Ringing Assignments Processor Type:DK14, DK40i Program Type:Station Initialized Default:All LEDs are OFF 6SNU +ROG 6SNU+ROG 6SNU+ROG 6SNU+ROG ProcessorCO Line RangeProcessorCO Line Range DK14 001~004 RCTUBA/BB 001~048 DK40i 001~012 RCTUC/D 001~144 RCTUA 001~016 RCTUE/F 001~200 Feature NumberCodeFeature DescriptionLine LED 0102030405060708091011121314151617181920 13Ring Over External Page during NIGHT mode 21DISA CO Line during DAY Mode 2DISA CO Line during DAY2 Mode 3DISA CO Line during NIGHT Mode 51Ring IMDU or RMDS 1 Modem during DAY Mode 1. RMDS requires RSIU and is available with DK424 only, IMDU requires PIOU or PIOUS. See Programs 77-1 LED 14, and Program 76 for RMDS. Only one built-in maintenance modem, IMDU or RMDS, will function at a time in DK424. 2Ring IMDU or RMDS1 Modem during DAY2 Mode 3Ring IMDU or RMDS 1 Modem during Night Mode 61Auto Attendant during DAY Mode 2 2. If CO lines should ring telephones before the Auto Attendant answers, use Program 81~89 to assign telephones to ring. Do not assign telephones in Program 81~89, if the Auto Attendant should answer on the first ring. 2Auto Attendant during DAY2 Mode2 3Auto Attendant during Night Mode2 CO Line Specify CO lines with LED Buttons as defined by the table below. All LEDs with an X should be lit when finished. Press 6FUROO to advance or 3DJH to go back. After programming, press: Press 9R Os to turn all LEDs ON Press 9R Ot to turn all LEDs OFF 0RGH + CO line number + to display and advance Feature Number 1, 2, 5, or 6 Code 1~3
![](/img/blank.gif)
System & Station Program 79 – Door Phone Ringing 100Strata DK System Record Sheets 5/99 Program 79 – Door Phone Ringing Processor Type:DK14, DK40i, All RCTUs Program Type:Station Initialized Default:All LEDs are OFF DP = Door Phone Program 6SNU +ROG 6SNU +ROG 6SNU+ROG 6SNU+ROG ProcessorPort RangeProcessorPort Range DK14 000~009 RCTUBA/BB 000~079 DK40i 000~027 RCTUC/D 000~239 RCTUA 000~031 RCTUE/F 000~335 FeatureLEDPorts Muted ring to busy DKT/EKT 20 19 18 17 16 15 14 13 Door phone 4C Ring DP12 12 Door phone 4B Ring DP11 11 Door phone 4A Ring DP10 10 Door phone 3C Ring DP9 9 Door phone 3B Ring DP8 8 Door phone 3A Ring DP7 7 Door phone 2C Ring DP6 6 Door phone 2B Ring DP5 5 Door phone 2A Ring DP4 4 Door phone 1C Ring DP3 3 Door phone 1B Ring DP2 2 Door phone 1A Ring DP1 1 Light the LED Buttons that are marked with an X in the table below.SELECT = Port Number Enter the port number having Door Phone Ringing assigned. To specify a port range, enter XXX XXX (low port high port).
![](/img/blank.gif)
System & Station Program *79 – Door Phone to [DN] Flashing Assignments Strata DK System Record Sheets 5/99101 System & Station Program *79 – Door Phone to [DN] Flashing Assignments Processor Type:DK14, DK40i, All RCTUs Program Type:Station Initialized Default:No [DNs] assigned to ring for any door phone 6SNU +ROG 6SNU+ROG 6SNU+ROG Processor[PDN] Port Range[PhDN] Port RangeProcessor[PDN] Port Range[PhDN] Port Range DK14 000~009 500~509 RCTUBA/BB 000~079 500~579 DK40i 000~027 500~527 RCTUC/D 000~239 500~739 RCTUA 000~031 500~531 RCTUE/F 000~335 500~835 Door Phone Number/LocationDoor Phone Box NumberDoor Box Circuit Number[DN] Port Reference Number 1 11 22 33 4 21 52 63 7 31 82 93 10 41 11 2 12 3 Enter a [DN] Port Reference (Port Number of the [DN] that should flash when the door phone button is pressed.) [DN] = [PDN] or [PhDN] port (see Legend below)Door Box Number (1~4) Door Box Circuit Number (1~3)
![](/img/blank.gif)
System & Station Program 80 – EKT and DKT Ringing Tones (CO Line Calls) 102Strata DK System Record Sheets 5/99 Program 80 – EKT and DKT Ringing Tones (CO Line Calls) Processor Type:DK14, DK40i, All RCTUs Program Type:Station Initialized Default:Tone 1 is assigned to all ports 6SNU +ROG 6SNU +ROG 6SNU+ROG 6SNU+ROG ProcessorPort RangeProcessorPort Range DK14 000~009 RCTUBA/BB 000~079 DK40i 000~027 RCTUC/D 000~239 RCTUA 000~031 RCTUE/F 000~335 Ringing Tone (Code)Ringing Tone (Code)Ringing Tone (Code) Port NumberTo n e 1 (1)To n e 2 (2)To n e 3 (3)Port NumberTo n e 1 (1)To n e 2 (2)To n e 3 (3)Port NumberTo n e 1 (1)To n e 2 (2)To n e 3 (3) Ringing Tone Code 1 = Tone Option 1 2 = Tone Option 2 3 = Tone Option 3SELECT = Station Logical Port Number Enter the telephone port number for which the ringing tone is being defined. To specify a port range, enter XXX XXX (low port high port). *Incoming Line Call distinctive ring tones apply to DID, ground, and loop start CO lines. Ring tone for internal or [DN] calls, and Tie line incoming calls is Ring Tone Option123 Incoming Line Call* 500/640 Hz 1200/1500 Hz 800/1000 Hz Transferred Line Call 540/760 Hz 1300/1780 Hz 880/1180 Hz
![](/img/blank.gif)
System & Station Program *80 – Call Forward Station Ring Assignment Strata DK System Record Sheets 5/99103 System & Station Program *80 – Call Forward Station Ring Assignment Processor Type:All RCTUs with Release 3.2 and above Program Type:Station Initialized Default:LED 01, 04, and 07 ON for all lines 6SNU +ROG 6SNU +ROG 6SNU+ROG 6SNU+ROG ProcessorCO Line RangeProcessorCO Line Range DK14 NA RCTUBA/BB 001~048 DK40i NA RCTUC/D 001~144 RCTUA 001~016 RCTUE/F 001~200 System Ring ModeCall Forward Station Ring AssignmentLEDCO Lines Night Delay 2 (89)09 Delay 1 (88)08 Immediate (87)07 Day 2 Delay 2 (86)06 Delay 1 (85)05 Immediate (84)04 Day Delay 2 (83)03 Delay 1 (82)02 Immediate (81)01 LED buttons = ringing assignment in which calls should Call ForwardSELECT = CO Line Number To specify a CO line range, enter XXX XXX (low line high line).
![](/img/blank.gif)
System & Station Programs 81~89 – Ground/Loop Start/CO Line Station Ringing 104Strata DK System Record Sheets 5/99 Programs 81~89 – Ground/Loop Start/CO Line Station Ringing Processor Type:DK14, DK40i, All RCTUs Program Type:System Initialized Default:All LEDs ON for Port 000 (81), Port 001 (87), all other LEDs OFF 6SNU +ROG 6SNU +ROG 6SNU+ROG 6SNU+ROG ProcessorStation Port RangeDH PortCO LineProcessorStation Port RangeDH PortCO Line DK14 000~009 900~909 001~004 RCTUBA/BB 000~079 900~915 001~048 DK40i 000~027 900~915 001~012 RCTUC/D 000~239 900~915 001~144 RCTUA 000~031 900~915 001~016 RCTUE/F 000~335 900~915 001~200 CO LineLEDStation or DH Port 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 LED Buttons = CO line assigned to ring selected station port or DH Group number(s). Press 6FUROO to advance or 3DJH to go back. SELECT = 1~9 (for type of ringing) Selected trunks ring selected station ports as follows: 81 = Immediate 84 = Immediate 87 = Immediate DAY 82 = 12-second delay DAY 2 85 = 12-second delay NIGHT 88 = 12-second delay 83 = 24-second delay 86 = 24-second delay 89 = 24-second delay SELECT = Station or DH port (see legend below)
![](/img/blank.gif)
System & Station Programs *81, *84, and *87 – Ground/Loop Start/CO Line to [DN] LED Flash Assignments Strata DK System Record Sheets 5/99105 System & Station Programs *81, *84, and *87 – Ground/Loop Start/CO Line to [DN] LED Flash Assignments Processor Type:DK14, DK40i, All RCTUs Program Type:System Initialized Default:CO 018~200 flashes Port 000 (*81) and Port 001 (*87) 6SNU +ROG 6SNU 6SNU+ROG 6SNU+ROG ProcessorCO Line[PDN] Port Range[PhDN] Port RangeProcessorCO Line[PDN] Port Range[PhDN] Port Range DK14 001~004 000~009 500~509 RCTUBA/BB 001~048 000~079 500~579 DK40i 001~012 000~027 500~527 RCTUC/D 001~144 000~239 500~739 RCTUA 001~016 000~031 500~531 RCTUE/F 001~200 000~335 500~835 CO Line NumberDay Ring [DN] (*81)Day 2 Ring [DN] (*84)Night Ring [DN] (*87)CO Line NumberDay Ring [DN] (*81)Day 2 Ring [DN] (*84)Night Ring [DN] (*87) . Ringing Assignments 1 = Day Ring 4 = Day 2 Ring 7 = Night Ring CO line number (see table below) To add a CO line range, enter XXX XXX (low CO line high CO line). Station Logical Port Number Enter the [PDN] or [PhDN] that should flash LED Button 01 enters blank data.
![](/img/blank.gif)
System & Station Program 93 – CO Line Identification 106Strata DK System Record Sheets 5/99 Program 93 – CO Line Identification Processor Type:DK14, DK40i, All RCTUs Program Type:System Initialized Default:Blank Numeric Mode ~ are treated as numerals. Dial pad starts in numeric mode. Press to switch to alpha mode. 6SNU +ROG 6SNU ‡‡‡ +ROG 6SNU+ROG 6SNU+ROG ProcessorCO Line RangeProcessorCO Line Range DK14 001~004 RCTUBA/BB 001~048 DK40i 001~012 RCTUC/D 001~144 RCTUA 001~016 RCTUE/F 001~200 LEDLineCO Line Identification (16 Characters Max. Enter One per Rectangle) 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 CO Line Identification Enter the CO line identification. (See next page for data entry procedures.)SELECT = 1 LED Button for CO line being named. To advance the line range, press Scroll. Press Page for a lower range.