2.7 [1] Configuration PC Programming Manual 61 Supported Card Types 2.7.2 [1-1] Slot—Summary Summary information is displayed for all cards installed in the PBX. Slot Indicates the slot number (reference only). Default Current slot number Value Range Available slot numbers. Maintenance Console Location 2.7.2 [1-1] Slot—Summary Programming Manual References NoneCard Maximum QuantitySupported Slot NumbersCard Programming MPR: Main Processing Card 1 00 2.7.2 [1-1] Slot—Summary HLC4: Pre-installed Hybrid Ports 1 01 2.7.3 [1-1] Slot—Extension Card Property HLC4: 4-Port Hybrid Extension Card 1 02–04 (Type A Slots) PLC4: 4-Port Proprietary Extension Card LCOT4: 4-Port Analog CO Line Card 2 2.7.7 [1-1] Slot—LCO Card Property PLC8: 8-Port Proprietary Extension Card 205–06 (Type B Slots)2.7.3 [1-1] Slot—Extension Card Property SLC8: 8-Port Single Line Telephone Extension Card DPH4: 4-Port Doorphone Card 108–09 (Option Slots)2.7.10 [1-1] Slot—DPH Card Property MSG2: 2-Channel Message Card 2 08–11 (Option Slots)None ECHO8: 8-Channel Echo Canceller Card1 EXT-CID: Extension Caller ID Card 1 SVM2: 2-Channel Simplified Voice Message Card2
2.7 [1] Configuration 62 PC Programming Manual Feature Manual References None Slot Type Indicates the type of each slot (reference only). Default Not applicable. Value Range Fixed Slot: For initially installed 4 Hybrid ports Free Slot Type A (02–04): For LCOT4/HLC4/PLC4 card Free Slot Type B (05–06): For PLC8/SLC8 card Option Slot (08–09): For MSG2/DPH4/ECHO8/EXT-CID/SVM2 card Option Slot (10–11): For MSG2/ECHO8/EXT-CID/SVM2 card Maintenance Console Location 2.7.2 [1-1] Slot—Summary Installation Manual References 2.2.6 Installing/Removing the Optional Service Cards Programming Manual References None Feature Manual References None Card Type Indicates the type of service card installed in each slot of the PBX (reference only). Note that for MPR cards, the PBX model code is displayed in parentheses after the name. Default Slot 00: MPR (Main Processing Card: fixed) Other slots: Not stored. Value Range HLC4: 4-Port Hybrid Extension Card PLC4: 4-Port Proprietary Extension Card PLC8: 8-Port Proprietary Extension Card SLC8: 8-Port Single Line Telephone Extension Card LCOT4: 4-Port Analog CO Line Card MSG2: 2-Channel Message Card DPH4: 4-Port Doorphone Card ECHO8: 8-Channel Echo Canceller Card
2.7 [1] Configuration PC Programming Manual 63 EXT-CID: Extension Caller ID Card SVM2: 2-Channel Simplified Voice Message Card MPR: MPR Card Maintenance Console Location 2.7.2 [1-1] Slot—Summary Programming Manual References 2.7.1 [1-1] Slot 2.7.3 [1-1] Slot—Extension Card Property 2.7.7 [1-1] Slot—LCO Card Property 2.7.10 [1-1] Slot—DPH Card Property Feature Manual References None Status Indicates the card status (reference only). Note that MPR card status is always displayed as -. Default Slot 00: - (fixed) Other slots: Current status Value Range INS: The port is in service. OUS: The por t is out of service. Fault: The port is not communicating with the network. Pre-Install: A card has been added to the slot. Idle: No card is installed in the slot. Maintenance Console Location 2.7.2 [1-1] Slot—Summary Programming Manual References 2.7.1 [1-1] Slot Feature Manual References None 2.7.3 [1-1] Slot—Extension Card Property The property for the extension cards can be specified.
2.7 [1] Configuration 64 PC Programming Manual SLT Pulse Dial Mode Selects the type of pulse dial transmission appropriate to your area. Default Normal Value Range Normal, Sweden, New Zealand Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References None SLT Off Hook Time Specifies the minimum length that a pulse dial sent from an SLT must be for the PBX to recognize it as an off-hook signal. Default 160 ms Value Range 8 × n (n=3–255) ms Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References None SLT Off Hook Guard Time Specifies the length of guard time used for off-hook signals from SLTs, to prevent the PBX mistaking them for pulse dials. Default 504 ms
2.7 [1] Configuration PC Programming Manual 65 Value Range 8 × n (n=12–63) ms Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References None SLT Pulse Maximum Break Width Specifies the maximum length of the break signal in a pulse dial. Default 96 ms Value Range 8 × n (n=9–20) ms Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References None SLT Pulse Minimum Make Width Specifies the minimum length of the make signal in a pulse dial. Default 8 ms Value Range 8 × n (n=1–5) ms Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None
2.7 [1] Configuration 66 PC Programming Manual Feature Manual References None SLT Flash Detection Enables the PBX to detect the flash signal sent when an SLT user presses the hookswitch or the Flash/Recall button. Default Enable Value Range Disable: The PBX disconnects the line to prevent placing the call on hold. Enable: The PBX places the call on consultation hold. Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References 1.3.7 Call Splitting Flash Timing - Min. Specifies the minimum length that a signal sent from an SLT must be for the PBX to recognize it as a hookswitch flash signal. Default 112 ms Value Range 8 × n (n=3–63) ms Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References None Flash Timing - Range Specifies the maximum length that a signal sent from an SLT can be for the PBX to recognize it as a hookswitch flash signal.
2.7 [1] Configuration PC Programming Manual 67 Default 904 ms Value Range 8 × n (n=3–191) ms Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References None DTMF-R STD Detection Time Specifies the minimum length that a DTMF tone must be for the PBX to recognize it as a DTMF tone. Default 30 ms Value Range 2 × n (n=1–31) ms Maintenance Console Location 2.7.3 [1-1] Slot—Extension Card Property Programming Manual References None Feature Manual References None 2.7.4 [1-1] Slot—Extension Port Various settings can be programmed for each extension port. To change the status of extension ports, click Command. To view total numbers of each type of extension connected, click Por t Type View. Slot Indicates the slot position (reference only). Default Current slot number
2.7 [1] Configuration 68 PC Programming Manual Value Range Slot number Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References None Feature Manual References None Por t Indicates the port number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References None Feature Manual References 1.5.7 Extension Port Configuration Por t Type Indicates the port type (reference only). Default Current port type Value Range APT: APT port (PLC) SLT: SLT port (SLC) Hybrid: Hybrid port (HLC) Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References None
2.7 [1] Configuration PC Programming Manual 69 Feature Manual References 1.5.7 Extension Port Configuration Telephone Type Indicates the connected telephone type (reference only). The number of all connected telephones and Cell Stations can be viewed by clicking Por t Type View. Default Current connected telephone type Value Range APT: APT is connected. DSS: DSS Console is connected. VM: VPS is connected. SLT: SLT is connected (or no telephone is connected to the Hybrid or SLT port). CS: CS is connected. No Connection: No telephone is connected. Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References 2.7.6 [1-1] Slot—Extension Port—Port Type View Feature Manual References 1.5.7 Extension Port Configuration Connection Indicates the por t status (reference only). This column offers two ways to open the screen to select the por t command as follows: Click the desired cell in the column. Select the desired cell in the column, and then click Command. Default Current status Value Range INS: The port is in service. OUS: The por t is out of service. Fault: The port is not communicating with the PBX. Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command
2.7 [1] Configuration 70 PC Programming Manual Feature Manual References None Extension Number Specifies the extension number of the port. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply. 2.Set the status of the extension port to OUS, then INS. When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the port is in use, the new extension number will not come into effect. Note that extensions that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Starting at 101 Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the extension name of the port. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.7.4 [1-1] Slot—Extension Port Programming Manual References None Feature Manual References None