    							2.7 [1] Configuration
    PC Programming Manual 61
    Supported Card Types
    2.7.2 [1-1] Slot—Summary
    Summary information is displayed for all cards installed in the PBX.
    Slot
    Indicates the slot number (reference only).
    Default
    Current slot number
    Value Range
    Available slot numbers.
    Maintenance Console Location
    2.7.2 [1-1] Slot—Summary
    Programming Manual References
    NoneCard Maximum 
    QuantitySupported Slot 
    NumbersCard Programming
    MPR: Main Processing Card 1 00 2.7.2 [1-1] Slot—Summary
    HLC4: Pre-installed Hybrid Ports 1 01
    2.7.3 [1-1] Slot—Extension Card 
    Property HLC4: 4-Port Hybrid Extension Card
    1
    02–04 (Type A 
    Slots) PLC4: 4-Port Proprietary Extension 
    Card
    LCOT4: 4-Port Analog CO Line Card 2 2.7.7 [1-1] Slot—LCO Card Property
    PLC8: 8-Port Proprietary Extension 
    Card
    205–06 (Type B 
    Slots)2.7.3 [1-1] Slot—Extension Card 
    Property
    SLC8: 8-Port Single Line Telephone 
    Extension Card
    DPH4: 4-Port Doorphone Card
    108–09 (Option 
    Slots)2.7.10 [1-1] Slot—DPH Card Property
    MSG2: 2-Channel Message Card 2
    08–11 (Option 
    Slots)None ECHO8: 8-Channel Echo Canceller 
    Card1
    EXT-CID: Extension Caller ID Card 1
    SVM2: 2-Channel Simplified Voice 
    Message Card2 
    						
    							2.7 [1] Configuration
    62 PC Programming Manual
    Feature Manual References
    None
    Slot Type
    Indicates the type of each slot (reference only).
    Default
    Not applicable.
    Value Range
    Fixed Slot: For initially installed 4 Hybrid ports
    Free Slot Type A (02–04): For LCOT4/HLC4/PLC4 card
    Free Slot Type B (05–06): For PLC8/SLC8 card
    Option Slot (08–09): For MSG2/DPH4/ECHO8/EXT-CID/SVM2 card
    Option Slot (10–11): For MSG2/ECHO8/EXT-CID/SVM2 card
    Maintenance Console Location
    2.7.2 [1-1] Slot—Summary
    Installation Manual References
    2.2.6 Installing/Removing the Optional Service Cards
    Programming Manual References
    None
    Feature Manual References
    None
    Card Type
    Indicates the type of service card installed in each slot of the PBX (reference only).
    Note that for MPR cards, the PBX model code is displayed in parentheses after the name.
    Default
    Slot 00: MPR (Main Processing Card: fixed)
    Other slots: Not stored.
    Value Range
    HLC4: 4-Port Hybrid Extension Card
    PLC4: 4-Port Proprietary Extension Card
    PLC8: 8-Port Proprietary Extension Card
    SLC8: 8-Port Single Line Telephone Extension Card
    LCOT4: 4-Port Analog CO Line Card
    MSG2: 2-Channel Message Card
    DPH4: 4-Port Doorphone Card
    ECHO8: 8-Channel Echo Canceller Card 
    						
    							2.7 [1] Configuration
    PC Programming Manual 63
    EXT-CID: Extension Caller ID Card
    SVM2: 2-Channel Simplified Voice Message Card
    MPR: MPR Card
    Maintenance Console Location
    2.7.2 [1-1] Slot—Summary
    Programming Manual References
    2.7.1 [1-1] Slot
    2.7.3 [1-1] Slot—Extension Card Property
    2.7.7 [1-1] Slot—LCO Card Property
    2.7.10 [1-1] Slot—DPH Card Property
    Feature Manual References
    None
    Status
    Indicates the card status (reference only).
    Note that MPR card status is always displayed as -.
    Default
    Slot 00: - (fixed)
    Other slots: Current status
    Value Range
    INS: The port is in service.
    OUS: The por t is out of service.
    Fault: The port is not communicating with the network.
    Pre-Install: A card has been added to the slot.
    Idle: No card is installed in the slot.
    Maintenance Console Location
    2.7.2 [1-1] Slot—Summary
    Programming Manual References
    2.7.1 [1-1] Slot
    Feature Manual References
    None
    2.7.3 [1-1] Slot—Extension Card Property
    The property for the extension cards can be specified. 
    						
    							2.7 [1] Configuration
    64 PC Programming Manual
    SLT Pulse Dial Mode
    Selects the type of pulse dial transmission appropriate to your area.
    Default
    Normal 
    Value Range
    Normal, Sweden, New Zealand
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    SLT Off Hook Time
    Specifies the minimum length that a pulse dial sent from an SLT must be for the PBX to recognize it 
    as an off-hook signal.
    Default
    160 ms
    Value Range
    8 × n (n=3–255) ms
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    SLT Off Hook Guard Time
    Specifies the length of guard time used for off-hook signals from SLTs, to prevent the PBX mistaking 
    them for pulse dials.
    Default
    504 ms 
    						
    							2.7 [1] Configuration
    PC Programming Manual 65
    Value Range
    8 × n (n=12–63) ms
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    SLT Pulse Maximum Break Width
    Specifies the maximum length of the break signal in a pulse dial.
    Default
    96 ms
    Value Range
    8 × n (n=9–20) ms
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    SLT Pulse Minimum Make Width
    Specifies the minimum length of the make signal in a pulse dial.
    Default
    8 ms
    Value Range
    8 × n (n=1–5) ms
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None 
    						
    							2.7 [1] Configuration
    66 PC Programming Manual
    Feature Manual References
    None
    SLT Flash Detection
    Enables the PBX to detect the flash signal sent when an SLT user presses the hookswitch or the 
    Flash/Recall button.
    Default
    Enable
    Value Range
    Disable: The PBX disconnects the line to prevent placing the call on hold.
    Enable: The PBX places the call on consultation hold.
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    1.3.7 Call Splitting
    Flash Timing - Min.
    Specifies the minimum length that a signal sent from an SLT must be for the PBX to recognize it as 
    a hookswitch flash signal.
    Default
    112 ms
    Value Range
    8 × n (n=3–63) ms
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    Flash Timing - Range
    Specifies the maximum length that a signal sent from an SLT can be for the PBX to recognize it as a 
    hookswitch flash signal. 
    						
    							2.7 [1] Configuration
    PC Programming Manual 67
    Default
    904 ms
    Value Range
    8 × n (n=3–191) ms
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    DTMF-R STD Detection Time
    Specifies the minimum length that a DTMF tone must be for the PBX to recognize it as a DTMF tone.
    Default
    30 ms
    Value Range
    2 × n (n=1–31) ms
    Maintenance Console Location
    2.7.3 [1-1] Slot—Extension Card Property
    Programming Manual References
    None
    Feature Manual References
    None
    2.7.4 [1-1] Slot—Extension Port
    Various settings can be programmed for each extension port.
    To change the status of extension ports, click Command. To view total numbers of each type of 
    extension connected, click Por t Type View.
    Slot
    Indicates the slot position (reference only).
    Default
    Current slot number 
    						
    							2.7 [1] Configuration
    68 PC Programming Manual
    Value Range
    Slot number
    Maintenance Console Location
    2.7.4 [1-1] Slot—Extension Port
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the port number (reference only).
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.7.4 [1-1] Slot—Extension Port
    Programming Manual References
    None
    Feature Manual References
    1.5.7 Extension Port Configuration
    Por t Type
    Indicates the port type (reference only).
    Default
    Current port type
    Value Range
    APT: APT port (PLC)
    SLT: SLT port (SLC)
    Hybrid: Hybrid port (HLC)
    Maintenance Console Location
    2.7.4 [1-1] Slot—Extension Port
    Programming Manual References
    None 
    						
    							2.7 [1] Configuration
    PC Programming Manual 69
    Feature Manual References
    1.5.7 Extension Port Configuration
    Telephone Type
    Indicates the connected telephone type (reference only).
    The number of all connected telephones and Cell Stations can be viewed by clicking Por t Type View.
    Default
    Current connected telephone type
    Value Range
    APT: APT is connected.
    DSS: DSS Console is connected.
    VM: VPS is connected.
    SLT: SLT is connected (or no telephone is connected to the Hybrid or SLT port).
    CS: CS is connected.
    No Connection: No telephone is connected.
    Maintenance Console Location
    2.7.4 [1-1] Slot—Extension Port
    Programming Manual References
    2.7.6 [1-1] Slot—Extension Port—Port Type View
    Feature Manual References
    1.5.7 Extension Port Configuration
    Connection
    Indicates the por t status (reference only).
    This column offers two ways to open the screen to select the por t command as follows:
     Click the desired cell in the column.
     Select the desired cell in the column, and then click Command.
    Default
    Current status
    Value Range
    INS: The port is in service.
    OUS: The por t is out of service.
    Fault: The port is not communicating with the PBX.
    Maintenance Console Location
    2.7.4 [1-1] Slot—Extension Port
    Programming Manual References
    2.7.5 [1-1] Slot—Extension Port—Port Command 
    						
    							2.7 [1] Configuration
    70 PC Programming Manual
    Feature Manual References
    None
    Extension Number
    Specifies the extension number of the port.
    To change the extension number of a wired extension, follow the steps below:
    1.Type the new extension number, then click Apply.
    2.Set the status of the extension port to OUS, then INS.
    When changing the extension number, make sure that the extension port is not in use. If the extension 
    number is changed while the port is in use, the new extension number will not come into effect.
    Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
    numbers of 2–4 digits.
    Default
    Starting at 101
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.7.4 [1-1] Slot—Extension Port
    Programming Manual References
    2.7.5 [1-1] Slot—Extension Port—Port Command
    Feature Manual References
    None
    Extension Name
    Specifies the extension name of the port.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.7.4 [1-1] Slot—Extension Port
    Programming Manual References
    None
    Feature Manual References
    None 
    						
    All Panasonic manuals Comments (0)