Home > Panasonic > Wireless PBX > Panasonic Kx Taw848 Programing Manual

Panasonic Kx Taw848 Programing Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Kx Taw848 Programing Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 480
    							2.10 [4] Extension
    PC Programming Manual 351
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.17.4 Time Service
    Parameter Selection (for TRS Level Change)
    Specifies the TRS level to be used temporarily on a certain PS.
    Default
    1
    Value Range
    1–7
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.8.11 [2-7-1] Class of Service—COS Settings—TRS
    2.13 [7] TRS
    Feature Manual References
    1.4.4 Dial Tone Transfer
    1.17.5 TRS (Toll Restriction)
    Parameter Selection (for Time Service - Automatic / Manual)
    Specifies the Time Table to be used when the Time Service Switching Mode is set to automatic.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.8.5 [2-4] Week Table 
    						
    							2.10 [4] Extension
    352 PC Programming Manual
    Feature Manual References
    1.17.4 Time Service
    Ext. No. / Floating Ext. No. (for DSS)
    Specifies the number of an extension to be accessed.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    None
    Ext. No. / Floating Ext. No. (for ICD Group)
    Specifies the floating extension number of an incoming call distribution group to be accessed.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Feature Manual References
    1.9.1 ICD GROUP FEATURES
    Ext. No. / Floating Ext. No. (for Message Waiting)
    Specifies the number of an extension or floating extension number of an incoming call distribution 
    group for which messages are checked. If this cell is left empty, the PS will check its own messages 
    only. 
    						
    							2.10 [4] Extension
    PC Programming Manual 353
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.11.3 Message Waiting
    Ext. No. / Floating Ext. No. (for Group Fwd (Both))
    Specifies the floating extension number of an incoming call distribution group for which both intercom 
    and CO line calls are forwarded.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext. No. / Floating Ext. No. (for Group Fwd (External))
    Specifies the floating extension number of an incoming call distribution group for which CO line calls 
    are forwarded.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button 
    						
    							2.10 [4] Extension
    354 PC Programming Manual
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext. No. / Floating Ext. No. (for Group Fwd (Internal))
    Specifies the floating extension number of an incoming call distribution group for which intercom calls 
    are forwarded.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext. No. / Floating Ext. No. (for Log-in/Log-out)
    Specifies the floating extension number of an incoming call distribution group to log-in to or log-out 
    from.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out 
    						
    							2.10 [4] Extension
    PC Programming Manual 355
    Ext. No. / Floating Ext. No. (for Hurry-up)
    Specifies the floating extension number of the incoming call distribution group whose longest waiting 
    call will be redirected (Manual Queue Redirection).
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Overflow No Answer
    Feature Manual References
    1.9.5 ICD Group Features—Queuing
    Ext. No. / Floating Ext. No. (for Two-way Record)
    Specifies the floating extension number of the VM (DPT) group containing the PSs mailbox.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.16 [3-7-2] VM(DPT) Group—Unit Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    Ext. No. / Floating Ext. No. (for Two-way Transfer)
    Specifies the floating extension number of the VM (DPT) group containing the desired mailbox.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9) 
    						
    							2.10 [4] Extension
    356 PC Programming Manual
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.16 [3-7-2] VM(DPT) Group—Unit Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    Ext. No. / Floating Ext. No. (for Voice Mail Transfer)
    Specifies the floating extension number of the VM (DTMF/DPT) group containing the desired mailbox.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.9.16 [3-7-2] VM(DPT) Group—Unit Settings
    2.9.19 [3-8-2] VM(DTMF) Group—Group Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    1.19.5 Voice Mail DTMF Integration
    Dial (for One-touch)
    Specifies the number to be dialed. The PBX can have a maximum of 500 One-touch Dialing buttons 
    for PSs.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    PC Programming Manual 357
    Feature Manual References
    1.12.2 One-touch Dialing
    Optional Parameter (or Ringing Tone Type Number) (for Time Service)
    Specifies the Time Table to be used for changing time modes in the Automatic Switching mode.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.17.4 Time Service
    Optional Parameter (or Ringing Tone Type Number) (for Call Park)
    Specifies the number of the parking zone a call is to be parked in when a Call Park button with 
    Parameter Selection (for Call Park) on this screen set to Specific is pressed.
    Default
    0
    Value Range
    0–99
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.3.5 Call Park
    Ext No. of Mailbox (for Two-way Transfer)
    Specifies the number of the extension whose mailbox will be used to record conversations using One-
    touch Two-way Transfer. (For example, a secretary can record a conversation into the mailbox of a 
    boss.) If the cell is left empty, the extension user must specify the number of an extension each time. 
    						
    							2.10 [4] Extension
    358 PC Programming Manual
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    2.10.11 [4-2-3] Portable Station—Flexible Button—Flexible Button 
    Data Copy
    The flexible CO button settings of a PS can be copied to different PSs.
    Destination Extension Line
    Select the number and name of the PS that will receive the copied settings. Multiple PSs can be 
    selected. To select all PSs at once, click Select All.
    Maintenance Console Location
    2.10.11 [4-2-3] Portable Station—Flexible Button—Flexible Button Data Copy
    Programming Manual References
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Feature Manual References
    None
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    When an SVM card is installed in the PBX, Simplified Voice Message features can be provided for 
    each PS.
    This screen allows you to specify which card each extension belongs to, and the maximum number 
    of messages that can be stored for each extension.
    For more information on Simplified Voice Message, see 1.16.5 SVM (Simplified Voice Message) in 
    the Feature Manual.
    Extension Number
    Indicates the extension number (reference only). 
    						
    							2.10 [4] Extension
    PC Programming Manual 359
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension No.
    Feature Manual References
    None
    Extension Name
    Indicates the name of the extension (reference only).
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension Name
    2.10.8 [4-2-1] Portable Station—Extension Settings—Extension Name
    Feature Manual References
    None
    Simplified Voice Message
    Selects which SVM card to use to store and play back greetings and messages for the extension.
    Each extension must be assigned to a specific SVM card, and can only use the assigned card. If two 
    SVM cards are installed in the PBX, you should assign a number of extensions to each card, to 
    ensure that the necessary resources, such as message recording space, are available for each 
    extension.
    Default
    Card1
    Value Range
    None, Card1, Card2 
    						
    							2.10 [4] Extension
    360 PC Programming Manual
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    None
    Feature Manual References
    1.16.5 SVM (Simplified Voice Message)
    Maximum of SVM Log
    Specifies the maximum number of voice messages (not including greeting messages) that can be 
    stored for the extension.
    Default
    10
    Value Range
    1–100
    Maintenance Console Location
    2.10.12 [4-2-4] Portable Station—Simplified Voice Message
    Programming Manual References
    None
    Feature Manual References
    1.16.5 SVM (Simplified Voice Message)
    2.10.13 [4-3] DSS Console—Flexible Button
    A DSS Console can be used in conjunction with a PT. A maximum of 4 DSS Consoles can be 
    programmed. The DPT Type—Type (for Hybrid port) of the extension port that DSS Console is 
    connected must be set to DSS in 2.7.4 [1-1] Slot—Extension Port.
    Each flexible DSS button can be customized to access a certain feature. A maximum of 66 flexible 
    DSS buttons can be customized for each DSS Console. Select the desired DSS Console from the 
    DSS Console No. list. 
    To copy the flexible DSS button settings from one location to another, click the Copy to button.
    For more information on flexible buttons, see 1.6.3 Flexible Buttons in the Feature Manual.
    Pair Extension
    Specifies the extension number of the PT to be used in pair with the DSS Console.
    Default
    None 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Kx Taw848 Programing Manual