2.10 [4] Extension PC Programming Manual 351 Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Parameter Selection (for TRS Level Change) Specifies the TRS level to be used temporarily on a certain PS. Default 1 Value Range 1–7 Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—TRS 2.13 [7] TRS Feature Manual References 1.4.4 Dial Tone Transfer 1.17.5 TRS (Toll Restriction) Parameter Selection (for Time Service - Automatic / Manual) Specifies the Time Table to be used when the Time Service Switching Mode is set to automatic. Default 1 Value Range 1–8 Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table
2.10 [4] Extension 352 PC Programming Manual Feature Manual References 1.17.4 Time Service Ext. No. / Floating Ext. No. (for DSS) Specifies the number of an extension to be accessed. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References None Feature Manual References None Ext. No. / Floating Ext. No. (for ICD Group) Specifies the floating extension number of an incoming call distribution group to be accessed. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.1 ICD GROUP FEATURES Ext. No. / Floating Ext. No. (for Message Waiting) Specifies the number of an extension or floating extension number of an incoming call distribution group for which messages are checked. If this cell is left empty, the PS will check its own messages only.
2.10 [4] Extension PC Programming Manual 353 Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References None Feature Manual References 1.11.3 Message Waiting Ext. No. / Floating Ext. No. (for Group Fwd (Both)) Specifies the floating extension number of an incoming call distribution group for which both intercom and CO line calls are forwarded. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext. No. (for Group Fwd (External)) Specifies the floating extension number of an incoming call distribution group for which CO line calls are forwarded. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button
2.10 [4] Extension 354 PC Programming Manual Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext. No. (for Group Fwd (Internal)) Specifies the floating extension number of an incoming call distribution group for which intercom calls are forwarded. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext. No. (for Log-in/Log-out) Specifies the floating extension number of an incoming call distribution group to log-in to or log-out from. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out
2.10 [4] Extension PC Programming Manual 355 Ext. No. / Floating Ext. No. (for Hurry-up) Specifies the floating extension number of the incoming call distribution group whose longest waiting call will be redirected (Manual Queue Redirection). Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Overflow No Answer Feature Manual References 1.9.5 ICD Group Features—Queuing Ext. No. / Floating Ext. No. (for Two-way Record) Specifies the floating extension number of the VM (DPT) group containing the PSs mailbox. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.16 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext. No. / Floating Ext. No. (for Two-way Transfer) Specifies the floating extension number of the VM (DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 5 digits (consisting of 0–9)
2.10 [4] Extension 356 PC Programming Manual Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.16 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext. No. / Floating Ext. No. (for Voice Mail Transfer) Specifies the floating extension number of the VM (DTMF/DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.9.16 [3-7-2] VM(DPT) Group—Unit Settings 2.9.19 [3-8-2] VM(DTMF) Group—Group Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration 1.19.5 Voice Mail DTMF Integration Dial (for One-touch) Specifies the number to be dialed. The PBX can have a maximum of 500 One-touch Dialing buttons for PSs. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References None
2.10 [4] Extension PC Programming Manual 357 Feature Manual References 1.12.2 One-touch Dialing Optional Parameter (or Ringing Tone Type Number) (for Time Service) Specifies the Time Table to be used for changing time modes in the Automatic Switching mode. Default 1 Value Range 1–8 Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Optional Parameter (or Ringing Tone Type Number) (for Call Park) Specifies the number of the parking zone a call is to be parked in when a Call Park button with Parameter Selection (for Call Park) on this screen set to Specific is pressed. Default 0 Value Range 0–99 Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Ext No. of Mailbox (for Two-way Transfer) Specifies the number of the extension whose mailbox will be used to record conversations using One- touch Two-way Transfer. (For example, a secretary can record a conversation into the mailbox of a boss.) If the cell is left empty, the extension user must specify the number of an extension each time.
2.10 [4] Extension 358 PC Programming Manual Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.10 [4-2-3] Portable Station—Flexible Button Programming Manual References None Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration 2.10.11 [4-2-3] Portable Station—Flexible Button—Flexible Button Data Copy The flexible CO button settings of a PS can be copied to different PSs. Destination Extension Line Select the number and name of the PS that will receive the copied settings. Multiple PSs can be selected. To select all PSs at once, click Select All. Maintenance Console Location 2.10.11 [4-2-3] Portable Station—Flexible Button—Flexible Button Data Copy Programming Manual References 2.10.10 [4-2-3] Portable Station—Flexible Button Feature Manual References None 2.10.12 [4-2-4] Portable Station—Simplified Voice Message When an SVM card is installed in the PBX, Simplified Voice Message features can be provided for each PS. This screen allows you to specify which card each extension belongs to, and the maximum number of messages that can be stored for each extension. For more information on Simplified Voice Message, see 1.16.5 SVM (Simplified Voice Message) in the Feature Manual. Extension Number Indicates the extension number (reference only).
2.10 [4] Extension PC Programming Manual 359 Default Not stored. Value Range Max. 4 digits (consisting of 0–9) Maintenance Console Location 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Programming Manual References 2.7.12 [1-2] Portable Station—Extension No. Feature Manual References None Extension Name Indicates the name of the extension (reference only). Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Programming Manual References 2.7.12 [1-2] Portable Station—Extension Name 2.10.8 [4-2-1] Portable Station—Extension Settings—Extension Name Feature Manual References None Simplified Voice Message Selects which SVM card to use to store and play back greetings and messages for the extension. Each extension must be assigned to a specific SVM card, and can only use the assigned card. If two SVM cards are installed in the PBX, you should assign a number of extensions to each card, to ensure that the necessary resources, such as message recording space, are available for each extension. Default Card1 Value Range None, Card1, Card2
2.10 [4] Extension 360 PC Programming Manual Maintenance Console Location 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Maximum of SVM Log Specifies the maximum number of voice messages (not including greeting messages) that can be stored for the extension. Default 10 Value Range 1–100 Maintenance Console Location 2.10.12 [4-2-4] Portable Station—Simplified Voice Message Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) 2.10.13 [4-3] DSS Console—Flexible Button A DSS Console can be used in conjunction with a PT. A maximum of 4 DSS Consoles can be programmed. The DPT Type—Type (for Hybrid port) of the extension port that DSS Console is connected must be set to DSS in 2.7.4 [1-1] Slot—Extension Port. Each flexible DSS button can be customized to access a certain feature. A maximum of 66 flexible DSS buttons can be customized for each DSS Console. Select the desired DSS Console from the DSS Console No. list. To copy the flexible DSS button settings from one location to another, click the Copy to button. For more information on flexible buttons, see 1.6.3 Flexible Buttons in the Feature Manual. Pair Extension Specifies the extension number of the PT to be used in pair with the DSS Console. Default None