2.9 [3] Group PC Programming Manual 201 Simplified Voice Message Tone Detection—Silence Enables the disconnection of an SVM-originated CO-to-CO line call by silence detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Simplified Voice Message Tone Detection—Continuous Enables the disconnection of an SVM-originated CO-to-CO line call by continuous signal detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Simplified Voice Message Tone Detection—Cyclic Enables the disconnection of an SVM-originated CO-to-CO line call by cyclic signal detection. Default Enable Value Range Disable, Enable
2.9 [3] Group 202 PC Programming Manual Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References None Feature Manual References 1.16.5 SVM (Simplified Voice Message) Host PBX Access Code Group Name Specifies the name of the trunk group for programming reference. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References None Host PBX Access Code 1–10 Specifies the feature number used to access a CO line from the host PBX. Default Not stored. Value Range Max. 10 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings
2.9 [3] Group PC Programming Manual 203 Feature Manual References 1.8.5 Host PBX Access Code (Access Code to the Telephone Company from a Host PBX) 2.9.2 [3-1-2] Trunk Group—Local Access Priority Trunk groups can be assigned a priority for Idle Line Access. When making a CO line call by Idle Line Access, the PBX will search trunk groups for an idle CO line according to the priority assigned here. Trunk Group No. & Name Specifies the trunk group assigned to the corresponding priority level. Select the blank option to not assign a trunk group to the priority. Default Priority 1–64 = Trunk Group No. 1–64 Value Range Trunk Group No. 1–64 Maintenance Console Location 2.9.2 [3-1-2] Trunk Group—Local Access Priority Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.11 CO Line Access 1.7.1 GROUP FEATURES 2.9.3 [3-2] Extension Group Extensions can be assigned to a tenant according to their extension user groups. An extension user group can belong to only one tenant. However, one extension user group can belong to several call pickup groups and several paging groups. A maximum of 8 tenants can be programmed. Extension Group Name Specifies the name of the extension user group. Default Extension User Group 1–32: Extension Group 01–32 Value Range Max. 20 characters
2.9 [3] Group 204 PC Programming Manual Maintenance Console Location 2.9.3 [3-2] Extension Group Programming Manual References 2.9.4 [3-3] Call Pickup Group 2.9.6 [3-4] Paging Group 2.10.1 [4-1-1] Wired Extension—Extension Settings—Main—Extension Group 2.10.8 [4-2-1] Portable Station—Extension Settings—Main—Extension Group Feature Manual References 1.7.1 GROUP FEATURES Tenant Number Specifies the tenant to which the extension user group belongs. Default 1 Value Range 1–8 Maintenance Console Location 2.9.3 [3-2] Extension Group Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.7.1 GROUP FEATURES 1.17.2 Tenant Service 2.9.4 [3-3] Call Pickup Group Extensions can be assigned to a call pickup group according to their extension user groups. One extension user group can belong to up to 8 call pickup groups. A maximum of 64 call pickup groups can be programmed. To assign extension user groups to call pickup groups easily, click All Setting. Extension Group Name Indicates the name of the extension user group (reference only). Default Extension User Group 1–32: Extension Group 01–32
2.9 [3] Group PC Programming Manual 205 Value Range Max. 20 characters Maintenance Console Location 2.9.4 [3-3] Call Pickup Group Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES Pickup Group—1st–8th Selects the call pickup groups that the extension user group belongs to. One extension user group can be assigned to a maximum of 8 call pickup groups on this screen. To assign an extension user group to more than 8 call pickup groups, click All Setting. Default Same as extension user group number Value Range None, 01–64 Maintenance Console Location 2.9.4 [3-3] Call Pickup Group Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES 2.9.5 [3-3] Call Pickup Group—All Setting Extensions can be assigned to a call pickup group according to their extension user groups. One extension user group can belong to multiple call pickup groups. Call Pickup Group Name Specifies the name of the call pickup group.
2.9 [3] Group 206 PC Programming Manual Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.5 [3-3] Call Pickup Group—All Setting Programming Manual References 2.9.4 [3-3] Call Pickup Group Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES Extension Group 1–32 Specifies whether the extension user group belongs to the corresponding pickup group. Default ON for the same-numbered call pickup group Value Range ON (blue), OFF Maintenance Console Location 2.9.5 [3-3] Call Pickup Group—All Setting Programming Manual References 2.9.3 [3-2] Extension Group 2.9.4 [3-3] Call Pickup Group Feature Manual References 1.3.6 Call Pickup 1.7.1 GROUP FEATURES 2.9.6 [3-4] Paging Group Extensions can be assigned to a paging group according to their extension user groups. External pagers can also be assigned to a paging group. One extension user group or external pager can belong to multiple paging groups. A maximum of 32 paging groups can be programmed. To assign external pagers to paging groups, click External Pager. To assign extension user groups to paging groups easily, click All Setting.
2.9 [3] Group PC Programming Manual 207 Extension Group Name Indicates the name of the extension user group (reference only). Default Extension User Group 1–32: Extension Group 01–32 Value Range Max. 20 characters Maintenance Console Location 2.9.6 [3-4] Paging Group Programming Manual References 2.9.3 [3-2] Extension Group—Extension Group Name Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging Paging Group—1st–8th Selects the paging groups that the extension user group belongs to. One extension user group can be assigned to a maximum of 8 paging groups on this screen. To assign an extension user group to more than 8 paging groups, click All Setting. Default Same as extension user group number Value Range None, 01–32 Maintenance Console Location 2.9.6 [3-4] Paging Group Programming Manual References 2.9.3 [3-2] Extension Group 2.9.7 [3-4] Paging Group—All Setting Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging 2.9.7 [3-4] Paging Group—All Setting Extensions can be assigned to a paging group according to their extension user groups. One extension user group or external pager can belong to multiple paging groups.
2.9 [3] Group 208 PC Programming Manual Paging Group Name Specifies the name of the paging group. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.7 [3-4] Paging Group—All Setting Programming Manual References 2.9.6 [3-4] Paging Group Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging Extension Group 1–32 Specifies whether the extension user group belongs to the corresponding paging group. Default ON for same numbered paging group Value Range ON, OFF Maintenance Console Location 2.9.7 [3-4] Paging Group—All Setting Programming Manual References 2.9.3 [3-2] Extension Group 2.9.6 [3-4] Paging Group Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging 2.9.8 [3-4] Paging Group—External Pager External pagers can be assigned to a paging group. One external pager can belong to multiple paging groups.
2.9 [3] Group PC Programming Manual 209 Paging Group Name Indicates the name of the paging group (reference only). Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.8 [3-4] Paging Group—External Pager Programming Manual References 2.9.7 [3-4] Paging Group—All Setting—Paging Group Name Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging External Pager 1 Specifies whether the external pager belongs to the corresponding paging group. Default ON Value Range ON (blue), OFF Maintenance Console Location 2.9.8 [3-4] Paging Group—External Pager Programming Manual References 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings Feature Manual References 1.7.1 GROUP FEATURES 1.13.1 Paging 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Extensions can be assigned as members of an incoming call distribution group. Calls to an incoming call distribution group are distributed to its member extensions as programmed. A maximum of 128 incoming call distribution groups can be programmed. To view a list of all programmed extension numbers and types, click Extension List View (see 2.4.4 Tool—Extension List View). To assign extensions to ICD groups and change extension settings,
2.9 [3] Group 210 PC Programming Manual click Member List. For more information on ICD Groups, see 1.9.1 ICD GROUP FEATURES in the Feature Manual. Main Floating Extension Number Specifies the floating extension number of the incoming call distribution group. Note that groups that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Groups 001-064: 601–664 Groups 065-128: Not stored Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References None Group Name Specifies the name of the incoming call distribution group. Default ICD Group 001–ICD Group 128 Value Range Max. 20 characters Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References None