2.9 [3] Group PC Programming Manual 221 Value Range None, 1–15 Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Maximum No. of Busy Extensions Specifies the number of extensions that can accept calls simultaneously in the incoming call distribution group. Default Max. Value Range Max: Call arrives at an idle extension. 1–32 : Call will not arrive at an idle extension when the number of busy extensions exceeds the assigned number. Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.9.2 ICD Group Features—Group Call Distribution Last Extension Log-out Specifies whether the last extension logged-in to the incoming call distribution group is allowed to log out. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings

2.9 [3] Group 222 PC Programming Manual Programming Manual References None Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out VIP Call Mode Enables VIP Call mode, to prioritize calls received from multiple incoming call distribution groups. Default Disable Value Range Disable, Enable Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.9.6 ICD Group Features—VIP Call Programmed Mailbox No. Specifies the mailbox number of the incoming call distribution groups mailbox for Voice Processing Systems (VPS) with DTMF Integration. Default Not stored. Value Range Max. 16 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.19.5 Voice Mail DTMF Integration Group Log / Group FWD To set extension numbers easily, click Destination Setting (see 2.1.6 Extension Number Setting).

2.9 [3] Group PC Programming Manual 223 Floating Extension Number Specifies the floating extension number of the incoming call distribution group. Note that groups that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Groups 001-064: 601–664 Groups 065-128: Not stored Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References None Group Name Specifies the name of the incoming call distribution group. Default ICD Group 001–ICD Group 128 Value Range Max. 20 characters Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References None Incoming Call Log Memory Specifies the number of unanswered calls to the incoming call distribution group that can be logged in the call log memory. Default 10

2.9 [3] Group 224 PC Programming Manual Value Range 0–100 Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.3.3 Call Log, Incoming Group FWD Call from CO—Setting Indicates the current FWD status for incoming CO line calls directed to the incoming call distribution group (reference only). Default Off Value Range Off, On Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.6.6 FWD (Call Forwarding) Group FWD Call from CO—Destination Specifies the forward destination of incoming CO line calls directed to the incoming call distribution group. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, [ ] [Secret], and P [Pause]) Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None

2.9 [3] Group PC Programming Manual 225 Feature Manual References 1.6.6 FWD (Call Forwarding) Group FWD Call from Extension—Setting Indicates the current FWD status for incoming intercom calls directed to the incoming call distribution group (reference only). Default Off Value Range Off, On Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.6.6 FWD (Call Forwarding) Group FWD Call from Extension—Destination Specifies the forward destination of incoming intercom calls directed to the incoming call distribution group. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, [ ] [Secret] and P [Pause]) Maintenance Console Location 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Programming Manual References None Feature Manual References 1.6.6 FWD (Call Forwarding)

2.9 [3] Group 226 PC Programming Manual 2.9.10 [3-5-2] Incoming Call Distribution Group—Queuing Time Ta b l e A Queuing Time Table can contain up to 16 sequences which control how calls waiting in a queue are handled. A maximum of 64 Queuing Time Tables can be programmed. Queuing Sequence—Sequence 01–16 Specifies the command activated by the corresponding sequence. Default None Value Range None: Redirects the call to the next sequence Overflow: Redirects the call to the overflow destination when there is no answer Disconnect: Disconnects the line Sequence 01–16: Redirects the call to a different sequence Wait 5 × n (n=1–16) s: If preceded by an OGM, plays the Music on Hold for the specified period of time; if not preceded by an OGM, sends a ringback tone for the specified period of time. OGM 01–32: Sends a certain OGM Maintenance Console Location 2.9.10 [3-5-2] Incoming Call Distribution Group—Queuing Time Table Programming Manual References None Feature Manual References 1.11.4 Music on Hold 1.12.1 OGM (Outgoing Message) 1.9.4 ICD Group Features—Overflow 1.9.5 ICD Group Features—Queuing 2.9.11 [3-5-3] Incoming Call Distribution Group—Miscellaneous Optional settings related to Incoming Call Distribution Groups can be programmed. Options—Call Log to ICD Group for Answered Call Selects whether answered calls to an ICD Group are also logged in the Incoming Call Log for the group, in addition to the log of the extension that answered the call. Default Enable

2.9 [3] Group PC Programming Manual 227 Value Range Disable, Enable Maintenance Console Location 2.9.11 [3-5-3] Incoming Call Distribution Group—Miscellaneous Programming Manual References None Feature Manual References 1.9.1 ICD GROUP FEATURES 2.9.12 [3-5-4] Incoming Call Distribution Group—Member Each incoming call distribution group can have a maximum of 32 members (extensions) assigned to it, and each member can have its own delayed ringing and Wrap-up time settings. An extension can be a member of multiple incoming call distribution groups. Select the desired ICD group (1–128) from the ICD Group No. list. To assign members to the group, enter directly or click Extension Number Setting (see 2.1.6 Extension Number Setting). To copy the members to another group, click Member List Copy, select the group, and click OK. Extension Number Specifies the extension number of each member. In addition to the extension numbers of PT, SLT and PS extensions, floating extension numbers of PS Ring groups can also be specified. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.9.12 [3-5-4] Incoming Call Distribution Group—Member Programming Manual References 2.9.21 [3-9] PS Ring Group—Floating Extension Number Feature Manual References 1.9.1 ICD GROUP FEATURES Extension Name Indicates the name of the extension (reference only). Default Not stored.

2.9 [3] Group 228 PC Programming Manual Value Range Max. 20 characters Maintenance Console Location 2.9.12 [3-5-4] Incoming Call Distribution Group—Member Programming Manual References 2.9.21 [3-9] PS Ring Group—Group Name 2.10.1 [4-1-1] Wired Extension—Extension Settings—Main—Extension Name 2.10.8 [4-2-1] Portable Station—Extension Settings—Main—Extension Name Feature Manual References 1.9.1 ICD GROUP FEATURES Delayed Ring Specifies the delayed ringing setting of each member. (Applicable when the call distribution method of the incoming call distribution group is set to Ring.) Default Immediate Value Range Immediate, 1–6 Rings, No Ring Maintenance Console Location 2.9.12 [3-5-4] Incoming Call Distribution Group—Member Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Main—Distribution Method Feature Manual References 1.9.2 ICD Group Features—Group Call Distribution 2.9.13 [3-6] Extension Hunting Group If an extension within an idle extension hunting group is called when it is busy or in DND mode, the call can be redirected to another extension in the same hunting group, according to a preprogrammed hunting type. If there is no idle extension in the group, the call can then be redirected to the overflow destination, which can be different depending on the time mode (day/lunch/break/night). A maximum of 64 hunting groups can be programmed, each containing up to 16 extensions. To assign members to the group, click Member List. To assign extensions as overflow destinations easily, click Destination Setting (see 2.1.6 Extension Number Setting). Hunting Group Name Specifies the name of the hunting group.

2.9 [3] Group PC Programming Manual 229 Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.13 [3-6] Extension Hunting Group Programming Manual References None Feature Manual References 1.9.7 Idle Extension Hunting Hunting Type Specifies the hunting type for the hunting group. Default Circular Value Range Circular: Circulates until the call is answered or overflowed Terminated: Terminates at the last extension Maintenance Console Location 2.9.13 [3-6] Extension Hunting Group Programming Manual References None Feature Manual References 1.7.1 GROUP FEATURES 1.9.7 Idle Extension Hunting Overflow—Day, Lunch, Break, Night Specifies the overflow destination of an unanswered call in each time mode. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])

2.9 [3] Group 230 PC Programming Manual Maintenance Console Location 2.9.13 [3-6] Extension Hunting Group Programming Manual References None Feature Manual References 1.9.7 Idle Extension Hunting 2.9.14 [3-6] Extension Hunting Group—Member List Each hunting group can contain up to 16 extensions. Select the hunting group to program from the Hunting Group No. list. To assign members to the group, enter the extension numbers in Extension Number or click Extension Number Setting (see 2.1.6 Extension Number Setting). To copy numbers to another group, click Member List Copy, select the group, and click OK. Extension Number Specifies the extension number of the hunting group member. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.9.14 [3-6] Extension Hunting Group—Member List Programming Manual References 2.9.13 [3-6] Extension Hunting Group Feature Manual References 1.9.7 Idle Extension Hunting Extension Name Indicates the name of the extension, when an extension number is specified in Extension Number above (reference only). Default Not stored. Value Range Max. 20 characters