2.16 [10] Maintenance PC Programming Manual 441 Maintenance Local Alarm Display—Extension 1, Extension 2 Specifies the extension numbers of PTs that will be notified by the PBX about local alarms. When the PBX detects a PBX error, the System Alarm button on the PT turns on red. When this button is pressed, the display will show the error number, and the button light will turn off automatically. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.10.4 Local Alarm Information Daily Test Start Time—Set Enables the daily self check of the PBX for local alarm and error log. Default Disable Value Range Disable, Enable Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.10.4 Local Alarm Information Daily Test Start Time—Hour Specifies the hour of the PBX daily self check start time. Default 0
2.16 [10] Maintenance 442 PC Programming Manual Value Range 0–23 Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.10.4 Local Alarm Information Daily Test Start Time—Minute Specifies the minute of the PBX daily self check start time. Default 0 Value Range 0–59 Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.10.4 Local Alarm Information Remote Remote—Analog Remote (Modem) Floating Extension Number Specifies the floating extension number for analog remote maintenance. To enable this setting, an RMT card must be installed, and Remote—Remote Programming on this screen must be enabled. Default 599 Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main
2.16 [10] Maintenance PC Programming Manual 443 Programming Manual References None Feature Manual References 1.13.5 PC Programming Remote—Remote Programming Enables system programming, diagnosis, and data upload from a remote location. Default Enable Value Range Disable, Enable Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming Remote—Password Lock Counter for Remote Programming Specifies the number of successive incorrect password entries allowed before remote access is locked. Default None Value Range None, 1–15 Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming
2.16 [10] Maintenance 444 PC Programming Manual Remote—Remote Maintenance Dial Number (Own Telephone number for reference) Specifies the telephone number of the PBX used to access the PBX from a remote location for maintenance purposes. This number can be specified by Quick Setup. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.14.2 Quick Setup Password Passwords authorize the user to program the extension and the PBX by a PT or a personal computer. System Password - PT Programming—Prog ** : User Level Specifies the user level system password to authorize the PT user to access only the permitted system programming. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.15 PT Programming
2.16 [10] Maintenance PC Programming Manual 445 System Password - PT Programming—Prog *# : Administrator Level Specifies the administrator level system password to authorize the PT user to access all system programming. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.15 PT Programming Manager Password - PT Programming—Prog *1 Specifies the manager password to authorize the PT user to access manager programming. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.11.1 Manager Features System Password - PC Programming—User Level Specifies the system password used to access KX-TAW848 Maintenance Console at User Level. Default 1234 Value Range 4–10 digits (consisting of 0–9)
2.16 [10] Maintenance 446 PC Programming Manual Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming System Password - PC Programming—Administrator Level Specifies the system password used to access KX-TAW848 Maintenance Console at Administrator Level. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming System Password - PC Programming—Installer Level Specifies the system password used to access KX-TAW848 Maintenance Console at Installer Level. Default 1234 Value Range 4–10 digits (consisting of 0–9) Maintenance Console Location 2.16.1 [10-1] Main Programming Manual References None Feature Manual References 1.13.5 PC Programming
2.16 [10] Maintenance PC Programming Manual 447 2.16.2 [10-2] PT Programming Access The programming items accessible at User and Administrator level can be specified. 100 programming item numbers are displayed at a time. To display other sets of numbers, click the applicable tab. Program Number Indicates the programming item number (reference only). Default Current programming item number Value Range 000–999 Maintenance Console Location 2.16.2 [10-2] PT Programming Access Programming Manual References None Feature Manual References 1.13.15 PT Programming PROG** Selects whether User Level PT users can access each system programming item. Default 000–009, 020–099: Enable 010–019, 100–999: Disable Value Range Disable, Enable Maintenance Console Location 2.16.2 [10-2] PT Programming Access Programming Manual References None Feature Manual References 1.13.15 PT Programming
3.1 Revision History 450 PC Programming Manual 3.1 Revision History 3.1.1 KX-TAW848 PSMPR Software File Version 4.0xxx New Contents 2.8.20 [2-11-2] Audio Gain—Card 2.9.11 [3-5-3] Incoming Call Distribution Group—Miscellaneous 2.13.5 [7-5] Miscellaneous—TRS Table Mode for Level N (N=2_6) Changed Contents 2.3.3 Connect—Modem 2.4 Tool 2.5.8 Utility—Error Log 2.9.12 [3-5-4] Incoming Call Distribution Group—Member 2.10.1 [4-1-1] Wired Extension—Extension Settings 2.10.8 [4-2-1] Portable Station—Extension Settings 2.11.3 [5-3-1] Voice Message—DISA System 2.11.5 [5-3-3] Voice Message—SVM—SVM Cyclic Tone Option—Tone On Maximum Time 2.11.5 [5-3-3] Voice Message—SVM—SVM Cyclic Tone Option—Tone Off Maximum Time 2.12.7 [6-7] Dialing Plan 2.15.3 [9-3] Miscellaneous 2.16.1 [10-1] Main