2.8 [2] System PC Programming Manual 191 Programming Manual References None Feature Manual References 1.3.1 Caller ID Mark Signal bits Specifies the number of mark bits to send when sending Caller ID information to an SLT. Default 180 bits Value Range 10 × n (n=3–40) bits Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID Channel Seizure Wait Time Specifies the length of time that the PBX waits before starting to send the seizure signal following the first ring when sending Caller ID information to an SLT. Default 512 ms Value Range 64 × n (n=5–35) ms Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID
2.8 [2] System 192 PC Programming Manual Additional Local Trunk Access Code to Extension Caller ID Enables the PBX to automatically add a CO Line Access number to the received telephone number when sending the Caller ID number of an incoming CO line call to an SLT. Default Enable Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID Send Caller ID Date & Time to Extension Enables the PBX to send the date and time of an incoming call when sending Caller ID information to an SLT. Default Enable Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID Send Caller ID Name to Extension Enables the PBX to send the callers name when sending Caller ID information to an SLT. Default Enable
2.8 [2] System PC Programming Manual 193 Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID Send Caller ID Long Distance to Extension Enables the PBX to send a call qualifier (Long Distance) (if received from the CO line) when sending Caller ID information to an SLT. Default Enable Value Range Disable, Enable Maintenance Console Location 2.8.18 [2-10] Extension CID Settings Programming Manual References None Feature Manual References 1.3.1 Caller ID 2.8.19 [2-11-1] Audio Gain—Paging/MOH Gain levels for the External Pager/External BGM ports can be programmed. Paging—EPG (External Pager) Specifies the paging volume for the External Pager. Default -2 dB Value Range -15–15 dB
2.8 [2] System 194 PC Programming Manual Maintenance Console Location 2.8.19 [2-11-1] Audio Gain—Paging/MOH Programming Manual References 2.9.6 [3-4] Paging Group Feature Manual References 1.13.1 Paging MOH—(Music On Hold) Specifies the music volume for the External BGM. Default 9 dB Value Range -11–11 dB Maintenance Console Location 2.8.19 [2-11-1] Audio Gain—Paging/MOH Programming Manual References 2.8.3 [2-2] Operator & BGM Feature Manual References 1.2.1 BGM (Background Music) 1.11.4 Music on Hold 2.8.20 [2-11-2] Audio Gain—Card Gain levels can be programmed for each type of card. Up Gain (To PBX) Specifies the volume for audio signals from the selected type of card to the PBX. Default Depends on card type. Value Range -15–15 dB Maintenance Console Location 2.8.20 [2-11-2] Audio Gain—Card
2.8 [2] System PC Programming Manual 195 Programming Manual References None Feature Manual References None Down Gain (From PBX) Specifies the volume for audio signals from the PBX to the selected type of card. Default Depends on card type. Value Range -15–15 dB Maintenance Console Location 2.8.20 [2-11-2] Audio Gain—Card Programming Manual References None Feature Manual References None
2.9 [3] Group 196 PC Programming Manual 2.9 [3] Group 2.9.1 [3-1-1] Trunk Group—TRG Settings CO lines can be organized into trunk groups. The settings of each trunk group determine the settings of the CO lines within that group. A maximum of 64 trunk groups can be programmed. For more information on trunk groups, see 1.7.1 GROUP FEATURES in the Feature Manual. Main Group Name Specifies the name of the trunk group for programming reference. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References None COS Specifies the COS of the trunk group. If you wish to prevent such calls from being made, ensure that the COS specified here has a TRS level of 7 assigned for all relevant time modes in 2.8.11 [2-7-1] Class of Service—COS Settings. Default 7 Value Range 1–64 Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings
2.9 [3] Group PC Programming Manual 197 2.15.1 [9-1] CO Line Settings Feature Manual References None Line Hunting Order Specifies the CO line hunting sequence for the trunk group. The hunting sequence can be programmed to start from the lowest or highest numbered CO lines, or to rotate uniformly among all CO lines. Default High -> Low Value Range High -> Low, Low -> High, Rotation Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.11 CO Line Access CO-CO Duration Time Specifies the length of time that a CO-to-CO line call line call can be maintained before being disconnected. Default 10 min Value Range None, 1–60 min Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.12 CO Line Call Limitation
2.9 [3] Group 198 PC Programming Manual Extension-CO Duration Time Specifies the length of time that an extension-to-CO line call can be maintained before being disconnected. Default 10 min Value Range None, 1–60 min Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings 2.8.17 [2-9] System Options 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.12 CO Line Call Limitation Caller-ID Modification Table Specifies the table to be used for modifying caller information (telephone number). Default 1 Value Range 1–4 Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.12.2 [6-2] Caller ID Modification 2.15.1 [9-1] CO Line Settings Feature Manual References 1.3.1 Caller ID Dialing Plan Table Specifies the table to be used for en-bloc dialing. Default 1
2.9 [3] Group PC Programming Manual 199 Value Range 1–4 Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.12.7 [6-7] Dialing Plan Feature Manual References None Tone Detection Group Name Specifies the name of the trunk group for programming reference. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.15.1 [9-1] CO Line Settings Feature Manual References None DISA Tone Detection—Silence Enables the disconnection of a DISA-originated CO-to-CO line call line call by silence detection. Default Disable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings
2.9 [3] Group 200 PC Programming Manual Programming Manual References 2.11.3 [5-3-1] Voice Message—DISA System 2.15.1 [9-1] CO Line Settings Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA Tone Detection—Continuous Enables the disconnection of a DISA-originated CO-to-CO line call line call by continuous signal detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.11.3 [5-3-1] Voice Message—DISA System 2.15.1 [9-1] CO Line Settings Feature Manual References 1.4.6 DISA (Direct Inward System Access) DISA Tone Detection—Cyclic Enables the disconnection of a DISA-originated CO-to-CO line call line call by cyclic signal detection. Default Enable Value Range Disable, Enable Maintenance Console Location 2.9.1 [3-1-1] Trunk Group—TRG Settings Programming Manual References 2.11.3 [5-3-1] Voice Message—DISA System 2.15.1 [9-1] CO Line Settings Feature Manual References 1.4.6 DISA (Direct Inward System Access)