Home > Panasonic > Wireless PBX > Panasonic Kx Taw848 Programing Manual

Panasonic Kx Taw848 Programing Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Kx Taw848 Programing Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 480
    							2.10 [4] Extension
    PC Programming Manual 321
    Intercept No Answer Time
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension No.
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension Name
    Feature Manual References
    None
    Intercept No Answer Time—Day, Lunch, Break, Night
    Specifies the length of time until an unanswered call is redirected to the intercept routing destination 
    in each time mode.
    When this setting is set to 0, the system timer is used.
    Default
    0 
    						
    							2.10 [4] Extension
    322 PC Programming Manual
    Value Range
    0–240 s
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Intercept Routing No Answer (IRNA)—
    Day, Lunch, Break, Night
    Feature Manual References
    1.9.9 Intercept Routing
    Option 1
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension No.
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings 
    						
    							2.10 [4] Extension
    PC Programming Manual 323
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension Name
    Feature Manual References
    None
    Ring Pattern Table
    Specifies the Ring Tone Pattern Table to be used by the PS.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.8.14 [2-8-1] Ring Tone Patterns—Call from CO
    2.8.15 [2-8-2] Ring Tone Patterns—Call from Doorphone
    2.8.16 [2-8-3] Ring Tone Patterns—Call from Others
    Feature Manual References
    1.15.2 Ring Tone Pattern Selection
    Programmed Mailbox No.
    Specifies the mailbox number of the PSs mailbox for Voice Processing Systems (VPS) with DTMF 
    Integration.
    Default
    Not stored.
    Value Range
    Max. 16 digits (consisting of 0–9, *, and #)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.19.5 Voice Mail DTMF Integration 
    						
    							2.10 [4] Extension
    324 PC Programming Manual
    Transfer Recall Destination
    Specifies the transfer recall destination when an extension user transfers a call with the Call Transfer 
    without Announcement feature and the transferred call is not answered within a certain time period.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.8 Call Transfer
    ARS Itemized Code
    Specifies the itemized billing code used by the ARS feature for identifying the calls made from the PS 
    for accounting and billing purposes.
    Default
    Not stored.
    Value Range
    Max. 10 digits (consisting of 0–9, *, and #)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.14.6 [8-5] Carrier
    Feature Manual References
    1.1.3 ARS (Automatic Route Selection)
    1.19.1 Verification Code Entry
    Option 2
    Extension Number
    Indicates the extension number of the PS (reference only). 
    						
    							2.10 [4] Extension
    PC Programming Manual 325
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension No.
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension Name
    Feature Manual References
    None
    Manual C. Waiting for Extension Call
    Selects the method of receiving call waiting notification from other extensions.
    Default
    BSS
    Value Range
    Off: No notification
    BSS: Tone from the handset or built-in speaker
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings 
    						
    							2.10 [4] Extension
    326 PC Programming Manual
    Programming Manual References
    None
    Feature Manual References
    1.3.9 Call Waiting Tone
    Automatic C. Waiting
    Specifies whether to receive call waiting notification for a call from CO line, a doorphone call or a call 
    via an incoming call distribution group.
    Default
    On
    Value Range
    Off, On
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.9 Call Waiting Tone
    Pickup Dial Set
    Sets or cancels the Hot Line feature. The number specified in Pickup Dial No. on this screen is dialed 
    automatically after going off-hook when the Hot Line feature is active.
    Default
    Off
    Value Range
    Off, On
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Hot Line (Pickup Dial) Start
    Feature Manual References
    1.8.6 Hot Line 
    						
    							2.10 [4] Extension
    PC Programming Manual 327
    Pickup Dial No.
    Specifies the number to be dialed automatically after going off-hook when the Hot Line feature is 
    active.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.8.6 Hot Line
    Option 3
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension No.
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS.
    Default
    Not stored. 
    						
    							2.10 [4] Extension
    328 PC Programming Manual
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension Name
    Feature Manual References
    None
    Call Pickup Deny
    Specifies whether calls can be picked up by other extensions.
    Default
    Disable
    Value Range
    Disable: Allows other extension users to pick up calls to your PS
    Enable: Prevents other extension users from picking up calls to your PS
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.6 Call Pickup
    Executive Override Deny
    Specifies whether calls can be interrupted by other extensions.
    Default
    Disable
    Value Range
    Disable: Allows other extension users to interrupt an existing call
    Enable: Prevents other extension users from interrupting an existing call
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    PC Programming Manual 329
    Feature Manual References
    1.5.3 Executive Busy Override
    Absent Message
    Specifies the Personal Absent Message which, unlike the System Absent Message, can be 
    customized for each PS.
    Default
    Not stored.
    Value Range
    Max. 16 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.1.1 Absent Message
    Option 4
    Extension Number
    Indicates the extension number of the PS (reference only).
    Default
    Not stored.
    Value Range
    Max. 4 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension No.
    Feature Manual References
    None
    Extension Name
    Specifies the name of the PS. 
    						
    							2.10 [4] Extension
    330 PC Programming Manual
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.7.12 [1-2] Portable Station—Extension Name
    Feature Manual References
    None
    Outgoing Preferred Line
    Selects the line to be seized after going off-hook to make a call.
    Default
    ICM
    Value Range
    No Line: No line is seized.
    Idle: An idle CO line is seized automatically from the programmed trunk groups.
    ICM: An extension line is seized.
    F-1–F-12: A CO line programmed for a flexible CO button (F-1–F-12) is seized. A flexible CO button 
    customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected.
    Maintenance Console Location
    2.10.8 [4-2-1] Portable Station—Extension Settings
    Programming Manual References
    2.10.10 [4-2-3] Portable Station—Flexible Button
    Feature Manual References
    1.10.3 Line Preference—Outgoing
    Incoming Preferred Line
    Selects the line on which an incoming call is answered after going off-hook.
    Default
    Ringing Line
    Value Range
    No Line: No line is selected. Select a line by pressing the desired Line Access button to answer a call.
    Ringing Line: The longest ringing call is selected. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Kx Taw848 Programing Manual