    							2.10 [4] Extension
    PC Programming Manual 361
    Value Range
    None, Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.5.7 Extension Port Configuration
    Ty p e
    Specifies the feature to be assigned to the flexible DSS button.
    Default
    Not Stored
    Value Range
    Not Stored, Loop CO, Single CO, Group CO, DSS, One-touch, ICD Group, Message Waiting, FWD/
    DND (Both), FWD/DND (External), FWD/DND (Internal), Group Fwd (Both), Group Fwd (External), 
    Group Fwd (Internal), Account, Conference, Terminate, EFA, Call Park, Call Log, Log-in/Log-out, 
    Hurry-up, Wrap-up, System Alarm, Time Service, Answer, Release, TRS Level Change, Time 
    Service - Automatic/Manual, Two-way Record, Two-way Transfer, LCS, Voice Mail Transfer
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.10.14 [4-3] DSS Console—Flexible Button—Flexible button Data Copy
    Feature Manual References
    1.6.3 Flexible Buttons
    Parameter Selection (for Single CO)
    Specifies the CO line to be accessed.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button 
    						
    							2.10 [4] Extension
    362 PC Programming Manual
    Programming Manual References
    None
    Feature Manual References
    1.3.11 CO Line Access
    Parameter Selection (for Group CO)
    Specifies the trunk group to be accessed.
    Default
    1
    Value Range
    1–64
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.1 [3-1-1] Trunk Group—TRG Settings
    Feature Manual References
    1.3.11 CO Line Access
    Parameter Selection (for Call Park)
    Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone.
    Default
    Automatic
    Value Range
    Automatic, Specific
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.3.5 Call Park
    Parameter Selection (for Log-in/Log-out)
    Specifies which incoming call distribution groups that the paired extension belongs to are logged in 
    to or logged out from. 
    						
    							2.10 [4] Extension
    PC Programming Manual 363
    Default
    None
    Value Range
    None: The incoming call distribution group is selected manually.
    All: All incoming call distribution groups that the paired extension belongs to.
    Incoming Group: A pre-specified incoming call distribution group
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out
    Parameter Selection (for Time Service)
    Selects which time modes are switched manually.
    Default
    All
    Value Range
    All (Day/Night/Lunch/Break), Day/Night/Break, Day/Night/Lunch, Day/Night
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.17.4 Time Service
    Parameter Selection (for TRS Level Change)
    Specifies the TRS level to be used temporarily on a certain extension.
    Default
    1
    Value Range
    1–7
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button 
    						
    							2.10 [4] Extension
    364 PC Programming Manual
    Programming Manual References
    2.8.11 [2-7-1] Class of Service—COS Settings—TRS
    2.13 [7] TRS
    Feature Manual References
    1.4.4 Dial Tone Transfer
    1.17.5 TRS (Toll Restriction)
    Parameter Selection (for Time Service - Automatic/Manual)
    Specifies the Time Table to be used when the Time Service Switching Mode is set to automatic.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.17.4 Time Service
    Ext. No. / Floating Ext. No. (for DSS)
    Specifies the number of an extension to be accessed.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    None 
    						
    							2.10 [4] Extension
    PC Programming Manual 365
    Ext. No. / Floating Ext. No. (for ICD Group)
    Specifies the floating extension number of an incoming call distribution group to be accessed.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Feature Manual References
    1.9.1 ICD GROUP FEATURES
    Ext. No. / Floating Ext. No. (for Message Waiting)
    Specifies the number of an extension or floating extension number of an incoming call distribution 
    group for which messages are checked. If this cell is left empty, the paired extension will check its own 
    messages only.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.11.3 Message Waiting
    Ext. No. / Floating Ext. No. (for Group Fwd (Both))
    Specifies the floating extension number of an incoming call distribution group for which both intercom 
    and CO line calls are forwarded.
    Default
    Not stored. 
    						
    							2.10 [4] Extension
    366 PC Programming Manual
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext. No. / Floating Ext. No. (for Group Fwd (External))
    Specifies the floating extension number of an incoming call distribution group for which CO line calls 
    are forwarded.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext. No. / Floating Ext. No. (for Group Fwd (Internal))
    Specifies the floating extension number of an incoming call distribution group for which intercom calls 
    are forwarded.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD 
    						
    							2.10 [4] Extension
    PC Programming Manual 367
    Feature Manual References
    1.6.6 FWD (Call Forwarding)
    Ext. No. / Floating Ext. No. (for Call Log)
    Specifies the paired extensions number or the floating extension number of an incoming call 
    distribution group for which call log information is displayed. If the cell is left empty, the paired 
    extension will display its own call log information.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.3.3 Call Log, Incoming
    Ext. No. / Floating Ext. No. (for Log-in/Log-out)
    Specifies the floating extension number of an incoming call distribution group to log-in to or log-out 
    from.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out
    Ext. No. / Floating Ext. No. (for Hurry-up)
    Specifies the floating extension number of the incoming call distribution group whose longest waiting 
    call will be redirected (Manual Queue Redirection). 
    						
    							2.10 [4] Extension
    368 PC Programming Manual
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Overflow No Answer
    Feature Manual References
    1.9.5 ICD Group Features—Queuing
    Ext. No. / Floating Ext. No. (for Two-way Record)
    Specifies the floating extension number of the VM (DPT) group containing the paired extensions 
    mailbox.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.16 [3-7-2] VM(DPT) Group—Unit Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    Ext. No. / Floating Ext. No. (for Two-way Transfer)
    Specifies the floating extension number of the VM (DPT) group containing the desired mailbox.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button 
    						
    							2.10 [4] Extension
    PC Programming Manual 369
    Programming Manual References
    2.9.16 [3-7-2] VM(DPT) Group—Unit Settings
    2.9.19 [3-8-2] VM(DTMF) Group—Group Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    Ext. No. / Floating Ext. No. (for Voice Mail Transfer)
    Specifies the floating extension number of the VM (DTMF/DPT) group containing the desired mailbox.
    Default
    Not stored.
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.9.16 [3-7-2] VM(DPT) Group—Unit Settings
    2.9.19 [3-8-2] VM(DTMF) Group—Group Settings
    Feature Manual References
    1.19.4 Voice Mail DPT (Digital) Integration
    1.19.5 Voice Mail DTMF Integration
    Dial (for One-touch)
    Specifies the number to be dialed. The PBX can have a maximum of 2000 One-touch Dialing buttons 
    for extensions and DSS Consoles.
    Default
    Not stored.
    Value Range
    Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash])
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.12.2 One-touch Dialing 
    						
    							2.10 [4] Extension
    370 PC Programming Manual
    Optional Parameter (Ringing Tone Type Number) (for Time Service)
    Specifies the Time Table to be used for changing time modes in the Automatic Switching mode.
    Default
    1
    Value Range
    1–8
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    2.8.5 [2-4] Week Table
    Feature Manual References
    1.17.4 Time Service
    Optional Parameter (Ringing Tone Type Number) (for Call Park)
    Specifies the number of the parking zone a call is to be parked in when a Call Park button with 
    Parameter Selection (for Call Park) on this screen set to Specific is pressed.
    Default
    0
    Value Range
    0–99
    Maintenance Console Location
    2.10.13 [4-3] DSS Console—Flexible Button
    Programming Manual References
    None
    Feature Manual References
    1.3.5 Call Park
    Ext. No. of Mailbox (for Two-way Transfer)
    Specifies the number of the extension whose mailbox will be used to record conversations using One-
    touch Two-way Transfer. (For example, a secretary can record a conversation into the mailbox of a 
    boss.) If the cell is left empty, the extension user must specify the number of an extension each time.
    Default
    Not stored. 
    						