Panasonic Kx Taw848 Programing Manual
Have a look at the manual Panasonic Kx Taw848 Programing Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2.10 [4] Extension PC Programming Manual 361 Value Range None, Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.5.7 Extension Port Configuration Ty p e Specifies the feature to be assigned to the flexible DSS button. Default Not Stored Value Range Not Stored, Loop CO, Single CO, Group CO, DSS, One-touch, ICD Group, Message Waiting, FWD/ DND (Both), FWD/DND (External), FWD/DND (Internal), Group Fwd (Both), Group Fwd (External), Group Fwd (Internal), Account, Conference, Terminate, EFA, Call Park, Call Log, Log-in/Log-out, Hurry-up, Wrap-up, System Alarm, Time Service, Answer, Release, TRS Level Change, Time Service - Automatic/Manual, Two-way Record, Two-way Transfer, LCS, Voice Mail Transfer Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.10.14 [4-3] DSS Console—Flexible Button—Flexible button Data Copy Feature Manual References 1.6.3 Flexible Buttons Parameter Selection (for Single CO) Specifies the CO line to be accessed. Default 1 Value Range 1–8 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button
2.10 [4] Extension 362 PC Programming Manual Programming Manual References None Feature Manual References 1.3.11 CO Line Access Parameter Selection (for Group CO) Specifies the trunk group to be accessed. Default 1 Value Range 1–64 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.1 [3-1-1] Trunk Group—TRG Settings Feature Manual References 1.3.11 CO Line Access Parameter Selection (for Call Park) Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone. Default Automatic Value Range Automatic, Specific Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Parameter Selection (for Log-in/Log-out) Specifies which incoming call distribution groups that the paired extension belongs to are logged in to or logged out from.
2.10 [4] Extension PC Programming Manual 363 Default None Value Range None: The incoming call distribution group is selected manually. All: All incoming call distribution groups that the paired extension belongs to. Incoming Group: A pre-specified incoming call distribution group Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Parameter Selection (for Time Service) Selects which time modes are switched manually. Default All Value Range All (Day/Night/Lunch/Break), Day/Night/Break, Day/Night/Lunch, Day/Night Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Parameter Selection (for TRS Level Change) Specifies the TRS level to be used temporarily on a certain extension. Default 1 Value Range 1–7 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button
2.10 [4] Extension 364 PC Programming Manual Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—TRS 2.13 [7] TRS Feature Manual References 1.4.4 Dial Tone Transfer 1.17.5 TRS (Toll Restriction) Parameter Selection (for Time Service - Automatic/Manual) Specifies the Time Table to be used when the Time Service Switching Mode is set to automatic. Default 1 Value Range 1–8 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Ext. No. / Floating Ext. No. (for DSS) Specifies the number of an extension to be accessed. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References None
2.10 [4] Extension PC Programming Manual 365 Ext. No. / Floating Ext. No. (for ICD Group) Specifies the floating extension number of an incoming call distribution group to be accessed. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.1 ICD GROUP FEATURES Ext. No. / Floating Ext. No. (for Message Waiting) Specifies the number of an extension or floating extension number of an incoming call distribution group for which messages are checked. If this cell is left empty, the paired extension will check its own messages only. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.11.3 Message Waiting Ext. No. / Floating Ext. No. (for Group Fwd (Both)) Specifies the floating extension number of an incoming call distribution group for which both intercom and CO line calls are forwarded. Default Not stored.
2.10 [4] Extension 366 PC Programming Manual Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext. No. (for Group Fwd (External)) Specifies the floating extension number of an incoming call distribution group for which CO line calls are forwarded. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext. No. (for Group Fwd (Internal)) Specifies the floating extension number of an incoming call distribution group for which intercom calls are forwarded. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Group Log / Group FWD
2.10 [4] Extension PC Programming Manual 367 Feature Manual References 1.6.6 FWD (Call Forwarding) Ext. No. / Floating Ext. No. (for Call Log) Specifies the paired extensions number or the floating extension number of an incoming call distribution group for which call log information is displayed. If the cell is left empty, the paired extension will display its own call log information. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.3.3 Call Log, Incoming Ext. No. / Floating Ext. No. (for Log-in/Log-out) Specifies the floating extension number of an incoming call distribution group to log-in to or log-out from. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Ext. No. / Floating Ext. No. (for Hurry-up) Specifies the floating extension number of the incoming call distribution group whose longest waiting call will be redirected (Manual Queue Redirection).
2.10 [4] Extension 368 PC Programming Manual Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings—Overflow No Answer Feature Manual References 1.9.5 ICD Group Features—Queuing Ext. No. / Floating Ext. No. (for Two-way Record) Specifies the floating extension number of the VM (DPT) group containing the paired extensions mailbox. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.16 [3-7-2] VM(DPT) Group—Unit Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext. No. / Floating Ext. No. (for Two-way Transfer) Specifies the floating extension number of the VM (DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button
2.10 [4] Extension PC Programming Manual 369 Programming Manual References 2.9.16 [3-7-2] VM(DPT) Group—Unit Settings 2.9.19 [3-8-2] VM(DTMF) Group—Group Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration Ext. No. / Floating Ext. No. (for Voice Mail Transfer) Specifies the floating extension number of the VM (DTMF/DPT) group containing the desired mailbox. Default Not stored. Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.9.16 [3-7-2] VM(DPT) Group—Unit Settings 2.9.19 [3-8-2] VM(DTMF) Group—Group Settings Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration 1.19.5 Voice Mail DTMF Integration Dial (for One-touch) Specifies the number to be dialed. The PBX can have a maximum of 2000 One-touch Dialing buttons for extensions and DSS Consoles. Default Not stored. Value Range Max. 32 digits (consisting of 0–9, *, #, T [Transfer], [ ] [Secret], P [Pause], and F [Flash]) Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.12.2 One-touch Dialing
2.10 [4] Extension 370 PC Programming Manual Optional Parameter (Ringing Tone Type Number) (for Time Service) Specifies the Time Table to be used for changing time modes in the Automatic Switching mode. Default 1 Value Range 1–8 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References 2.8.5 [2-4] Week Table Feature Manual References 1.17.4 Time Service Optional Parameter (Ringing Tone Type Number) (for Call Park) Specifies the number of the parking zone a call is to be parked in when a Call Park button with Parameter Selection (for Call Park) on this screen set to Specific is pressed. Default 0 Value Range 0–99 Maintenance Console Location 2.10.13 [4-3] DSS Console—Flexible Button Programming Manual References None Feature Manual References 1.3.5 Call Park Ext. No. of Mailbox (for Two-way Transfer) Specifies the number of the extension whose mailbox will be used to record conversations using One- touch Two-way Transfer. (For example, a secretary can record a conversation into the mailbox of a boss.) If the cell is left empty, the extension user must specify the number of an extension each time. Default Not stored.