Panasonic Kx Taw848 Programing Manual
Have a look at the manual Panasonic Kx Taw848 Programing Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2.10 [4] Extension PC Programming Manual 271 Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Call Pickup Deny Specifies whether calls can be picked up by other extensions. Default Disable Value Range Disable: Allows other extension users to pick up calls to your extension Enable: Prevents other extension users from picking up calls to your extension Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.3.6 Call Pickup Executive Override Deny Specifies whether calls can be interrupted by other extensions. Default Disable Value Range Disable: Allows other extension users to interrupt an existing call Enable: Prevents other extension users from interrupting an existing call Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings
2.10 [4] Extension 272 PC Programming Manual Programming Manual References None Feature Manual References 1.5.3 Executive Busy Override Absent Message Specifies the Personal Absent Message which, unlike the System Absent Message, can be customized for each extension. Default Not stored. Value Range Max. 16 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.1.1 Absent Message Intercom Call by Voice Selects the method of receiving intercom calls. When Deny Voice Call is selected, the extension will always ring when receiving calls, regardless of how the caller wants to make the call. Default Tone Call Value Range Tone Call, Voice Call, Deny Voice Call Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.9.11 Intercom Call
2.10 [4] Extension PC Programming Manual 273 Option 4 Slot Indicates the slot position of each extension card (reference only). Default Current slot number Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the por t number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply. 2.Set the status of the extension port to OUS, then INS.
2.10 [4] Extension 274 PC Programming Manual When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the port is in use, the new extension number will not come into effect. Note that extensions that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Starting at 101 (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent extensions by adding one to the previous extension number.) Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the name of the extension. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Outgoing Preferred Line Selects the line to be seized after going off-hook to make a call. Default ICM
2.10 [4] Extension PC Programming Manual 275 Value Range No Line: No line is seized. Idle: An idle CO line is seized automatically from the programmed trunk groups. ICM: An extension line is seized. F-1–F-36: A CO line programmed for a flexible CO button (F-1–F-36) is seized. A flexible CO button customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected. Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.10.4 [4-1-4] Wired Extension—Flexible Button Feature Manual References 1.10.3 Line Preference—Outgoing Incoming Preferred Line Selects the line on which an incoming call is answered after going off-hook. Default Ringing Line Value Range No Line: No line is selected. Select a line by pressing the desired Line Access button to answer a call. Ringing Line: The longest ringing call is selected. F-1–F-36: The call arriving at a flexible CO button (F-1–F-36) is selected. A flexible CO button customized as a Single-CO, Group-CO, Loop-CO, or ICD Group button must be selected. Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.10.4 [4-1-4] Wired Extension—Flexible Button Feature Manual References 1.10.2 Line Preference—Incoming Call Waiting Tone Type Selects the type of Call Waiting tone sent to the busy extension. Default CW Tone 1 Value Range CW Tone 1, CW Tone 2
2.10 [4] Extension 276 PC Programming Manual Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.3.9 Call Waiting Tone LCS Recording Mode Specifies whether to continue or stop recording the message in the extensions mailbox when the extension user answers a call that was being monitored. Default Stop Record Value Range Stop Record, Keep Record Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.19.4 Voice Mail DPT (Digital) Integration LCS Answer Mode Specifies whether the extensions mailbox is monitored in Hands-free or Private mode. Default Hands free Value Range Hands free: Monitor through the built-in speaker Private: Monitor through the handset or the built-in speaker after hearing a warning tone Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.8.2 Hands-free Operation
2.10 [4] Extension PC Programming Manual 277 1.19.4 Voice Mail DPT (Digital) Integration Option 5 Slot Indicates the slot position of each extension card (reference only). Default Current slot number Value Range Slot number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Por t Indicates the por t number (reference only). Default Current port number Value Range Port number Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.4 [1-1] Slot—Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension. To change the extension number of a wired extension, follow the steps below: 1.Type the new extension number, then click Apply.
2.10 [4] Extension 278 PC Programming Manual 2.Set the status of the extension port to OUS, then INS. When changing the extension number, make sure that the extension port is not in use. If the extension number is changed while the port is in use, the new extension number will not come into effect. Note that extensions that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits. Default Starting at 101 (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent extensions by adding one to the previous extension number.) Value Range Max. 5 digits (consisting of 0–9) Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References 2.7.5 [1-1] Slot—Extension Port—Port Command Feature Manual References None Extension Name Specifies the name of the extension. Default Not stored. Value Range Max. 20 characters Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Display Language Selects the display language of the extension telephone. Default Language1
2.10 [4] Extension PC Programming Manual 279 Value Range Language1–Language5 Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.4.7 Display Information Incoming Call Display Selects which caller information is shown on the first line of the extensions display. Default Caller ID Name Value Range Caller ID Name, CO Line Name Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.4.7 Display Information Automatic LCD Switch when Start Talking Enables the first line of the display to show the call duration automatically after answering a CO line call. Default Enable Value Range Disable, Enable Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None
2.10 [4] Extension 280 PC Programming Manual Feature Manual References 1.4.7 Display Information Key Pad Tone Specifies whether key pad tones are heard when dialing. Default On Value Range Off, On Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References None Automatic Answer for CO Call Enables the extension to answer an incoming CO line call automatically after a cer tain number of rings without going off-hook, when Hands-free Answerback has been set on the extension. This setting is only effective when Forced Automatic Answer on this screen has been set to Off. Default Disable Value Range Disable, Enable Maintenance Console Location 2.10.1 [4-1-1] Wired Extension—Extension Settings Programming Manual References None Feature Manual References 1.8.1 Hands-free Answerback Option 6 Slot Indicates the slot position of each extension card (reference only).