Panasonic Kx Taw848 Programing Manual
Have a look at the manual Panasonic Kx Taw848 Programing Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2.8 [2] System PC Programming Manual 141 Programming Manual References 2.10.2 [4-1-2] Wired Extension—FWD/DND 2.10.9 [4-2-2] Portable Station—FWD / DND Feature Manual References 1.6.6 FWD (Call Forwarding) FWD No Answer Timer Set Specifies the feature number used to set the length of time before a call is forwarded. Default *713 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.10.2 [4-1-2] Wired Extension—FWD/DND 2.10.9 [4-2-2] Portable Station—FWD / DND Feature Manual References 1.6.6 FWD (Call Forwarding) Group FWD Set / Cancel: Call from CO & Extension Specifies the feature number used to set or cancel FWD for incoming CO line and intercom calls to an incoming call distribution group. Default *714 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.6.6 FWD (Call Forwarding)
2.8 [2] System 142 PC Programming Manual Group FWD Set / Cancel: Call from CO Specifies the feature number used to set or cancel FWD for incoming CO line calls to an incoming call distribution group. Default *715 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.6.6 FWD (Call Forwarding) Group FWD Set / Cancel: Call from Extension Specifies the feature number used to set or cancel FWD for incoming intercom calls to an incoming call distribution group. Default *716 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.6.6 FWD (Call Forwarding) Call Pickup Deny Set / Cancel Specifies the feature number used to set or cancel Call Pickup Deny (i.e., preventing other extensions from picking up calls to your extension). Default *720
2.8 [2] System PC Programming Manual 143 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.3.6 Call Pickup Paging Deny Set / Cancel Specifies the feature number used to set or cancel Paging Deny (i.e., preventing other extensions from paging your extension). Default *721 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.6 [3-4] Paging Group Feature Manual References 1.13.1 Paging Walking Extension Specifies the feature number used to use the same extension settings at a new extension. Default *727 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None
2.8 [2] System 144 PC Programming Manual Feature Manual References 1.20.2 Walking Extension Data Line Security Set / Cancel Specifies the feature number used to set or cancel Data Line Security (i.e., preventing signals from other extensions during data transmission). Default *730 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.4.1 Data Line Security Call Waiting Mode: Manual Call Waiting for Extension Call Specifies the feature number used to set or change the method of receiving a Call Waiting notification from an extension. Default *731 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.3.9 Call Waiting Tone Call Waiting Mode: Automatic Call Waiting Specifies the feature number used to set or cancel a Call Waiting notification from a CO line, doorphone, or a call via an incoming call distribution group.
2.8 [2] System PC Programming Manual 145 Default *732 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.3.9 Call Waiting Tone Executive Override Deny Set / Cancel Specifies the feature number used to set or cancel Executive Busy Override (i.e., preventing other extensions from joining your conversation). Default *733 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—Extension Feature—Executive Busy Override 2.8.11 [2-7-1] Class of Service—COS Settings—Programming & Manager—Executive Busy Override Deny Feature Manual References 1.5.3 Executive Busy Override Not Ready (Manual Wrap-up) Mode On / Off Specifies the feature number used to enter or leave Not Ready mode. Default *735 Value Range Max. 4 digits (consisting of 0–9, *, and #)
2.8 [2] System 146 PC Programming Manual Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Log-in / Log-out Specifies the feature number used to join or leave an incoming call distribution group. Default *736 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings Feature Manual References 1.9.3 ICD Group Features—Log-in/Log-out Hot Line (Pickup Dial) Program Set / Cancel Specifies the feature number used to set/cancel the Hot Line feature, or program the number to be automatically dialed. Default *740 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Hot Line (Pickup Dial) Start Feature Manual References 1.8.6 Hot Line
2.8 [2] System PC Programming Manual 147 Absent Message Set / Cancel Specifies the feature number used to set or cancel the display of an Absent Message. Default *750 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.1.1 Absent Message BGM Set / Cancel Specifies the feature number used to set or cancel the BGM heard through the telephone speaker while on-hook. Default *751 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.8.3 [2-2] Operator & BGM Feature Manual References 1.2.1 BGM (Background Music) Remote Timed Reminder (Remote Wakeup Call) Specifies the feature number used to set or cancel a Timed Reminder remotely (Wake-up Call). Default *76* Value Range Max. 4 digits (consisting of 0–9, *, and #)
2.8 [2] System 148 PC Programming Manual Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.17.3 Timed Reminder Timed Reminder Set / Cancel Specifies the feature number used to set or cancel a Timed Reminder. Default *760 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.17.3 Timed Reminder Printing Message Specifies the feature number used to select a Printing Message to be output on SMDR. Default *761 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.12.9 [6-8] Hotel—Main—SMDR for External Hotel Application 2—Printing Message 1–8 Feature Manual References 1.13.9 Printing Message
2.8 [2] System PC Programming Manual 149 Extension Dial Lock Set / Cancel Specifies the feature number used to lock or unlock an extension to make certain CO line calls and change the forwarding destination, using the Extension Dial Lock feature. Default *77 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None Feature Manual References 1.5.4 Extension Dial Lock Time Service (Day / Lunch / Break / Night) Switch Specifies the feature number, available for manager extensions, used to change the time mode manually. Default *780 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—Programming & Manager—Time Service Switch 2.8.11 [2-7-1] Class of Service—COS Settings—Programming & Manager—Manager Feature Manual References 1.17.4 Time Service Remote Extension Dial Lock Off Specifies the feature number, available for manager extensions, used to unlock other extensions using the Extension Dial Lock feature. Default *782
2.8 [2] System 150 PC Programming Manual Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—Programming & Manager—Manager Feature Manual References 1.5.4 Extension Dial Lock Remote Extension Dial Lock On Specifies the feature number, available for manager extensions, used to lock other extensions using the Extension Dial Lock feature. Default *783 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References 2.8.11 [2-7-1] Class of Service—COS Settings—Programming & Manager—Manager Feature Manual References 1.5.4 Extension Dial Lock Extension Feature Clear Specifies the feature number used to reset certain features of an extension to the default values. Default *790 Value Range Max. 4 digits (consisting of 0–9, *, and #) Maintenance Console Location 2.8.8 [2-6-1] Numbering Plan—Main Programming Manual References None