Home > NEC > Communications System > NEC Neax 2400 Ipx Wireless System Manual

NEC Neax 2400 Ipx Wireless System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Ipx Wireless System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 5 NDA-24301
    Pag e 2 84
    Revision 1.0
    APSP  : Assignment of Trunk Line Appearance for DM
    1. GENERAL
    This command is used to assign/delete the “COT trunk seizure” data, when a PS makes a call via this trunk and
    an LC (made cross connection with the COT) of the existing PBX with no wireless feature.
    2. PRECAUTIONS
    1. Assign the physical PS station number for the “PS STN” input data.
    2. This command data must be assigned to each COT circuit, that is provided with the physical cross
    connection with an LC of the “existing PBX with no wireless feature”.
    3. DATA ENTRY INSTRUCTIONS
    TENANT 
        (TN)PS STATION NUMBER 
                 (PS STN)Route Number 
             (RT) 
           1 - 255Trunk Number 
             (TK) 
           1 - 255
              PS STN 
    Enter the physical PS 
    station number.
                    RT 
    Enter the route number for 
    COT trunk to be provided.
                 TN 
    Enter Tenant Number.
                     TK 
    Enter the trunk number for  
    COT trunk to be provided. 
    						
    							NDA-24301 CHAPTER 5
    Page 285
    Revision 1.0
    4. DATA SHEET
    COT Trunk Seizure Data Assignment Sheet
    TENANT
    (TN)PS STATION NUMBER
    (PS STN)ROUTE NUMBER
    (RT)
    1 - 255TRUNK NUMBER
    (TK)
    1 - 255 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 86
    Revision 1.0
    AZDL  : ZT Program Download
    1. GENERAL
    This command is used to download ZT program from “Program Master ZT” to “Program Download ZT”.
    2. PRECAUTIONS
    1. This feature is available for Series 7300 or later software.
    2. For detailed information on ZT program Download service.
    3. DATA ENTRY INSTRUCTIONS
    PROGRAM MASTER ZT PCN : PHS Community Number of rogram Master ZT: 1-1024
    PROGRAM MASTER ZT CRN : Calling Area Number of Program Master ZT: 1-32
    PROGRAM MASTER ZT GRN : Group Number of Program Master ZT: 1-8
    PROGRAM MASTER ZT CSN/ZTN : ZT Number of Program Master ZT: 1-32
    PROGRAM DOWNLOAD ZT PCN : PHS Community Number of Slave Program Download ZT: 1-1024
    PROGRAM DOWNLOAD ZT CRN : Calling Area Number of Slave Program Download ZT: 1-32
    PROGRAM DOWNLOAD ZT GRN : Group Number of Slave Program Download ZT: 1-8
    PROGRAM DOWNLOAD ZT CSN/ZTN: ZT Number of Slave Program Download ZT: 1-32 
    						
    							NDA-24301 CHAPTER 5
    Page 287
    Revision 1.0
    4. DATA SHEET
    ZT Program Download Data Sheet 
    PROGRAM
    MASTER
    ZT PCN
    1-1024PROGRAM
    MASTER
    ZT CRN
    1-32PROGRAM
    MASTER
    ZT GRN
    1-8PROGRAM
    MASTER
    ZT
    CSN/ZTN
    1-32PROGRAM
    DOWNLOAD
    ZT PCN
    1-1024PROGRAM
    DOWNLOAD
    ZT CRN
    1-32PROGRAM
    DOWNLOAD
    ZT GRN
    1-8PROGRAM
    DOWNLOAD
    ZT
    CSN/ZTN
    1-32 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 88
    Revision 1.0
    AHLG  : Assignment of CFT Hot Line Group
    1. GENERAL
    This command is used to assign, delete and display the DM data which is concerned with PCS Calling
    Conference Group.
    List Up Command: LHLG
    2. PRECAUTIONS
    1. This command is available for Series 7400 or later software.
    2. “Set” key and “Del” key can be used after TN and ACC are entered and then this data is read by pressing
    “Get” key.
    If this data is not programmed, press “Get” key again, PORT, TYPE, D_TN, D_STN and D_ADC can be
    assigned.
    3. The input parameter depends on TYPE value.
    TYPE=0 or blank : Not displayed
    TYPE=1 : D_TN, D_STN
    TYPE=2 : D_ADC
    4. Only Speed Calling Dial Number which is the same tenant as conference leader port can be entered.
    5. The user must assign the data to all ports (PORT 0-7).
    6. If all ports are TYPE=0, this assignment ends in failure.
    7. Data writing is executed by pressing “Set” key.
    3. DATA ENTRY INSTRUCTIONS
    TN (TENANT NUMBER) : 1-
    ACC (CFTB H/L ACCESS CODE) : 0-9, #, * (maximum 5 digits)
    PORT (PORT NUMBER) : 1-7
    TYPE (KIND OF STN) : 0=Vacant Port
    1=STN/PS
    2=OUTSIDE TRUNK
    D_TN (TENANT NUMBER OF DESTINATION) : 1-
    D_STN (STATION NUMBER OF DESTINATION) : 0-9, #, * (maximum 5 digits)
    D_ADC (SPEED CALLING DIAL NUMBER OF DESTINATION): 0-9, #, * (maximum 4 digits) 
    						
    							NDA-24301 CHAPTER 5
    Page 289
    Revision 1.0
    4. DATA SHEET
    TENANT
    NUMBER
    (TN)STATION NUMBER OF CFTB H/L 
    ACCESS CODE
    (ACC)
    Max. 5 digits
    PORTKIND OF STN 
    (TYPE)
    0~2TENANT
    NUMBER OF 
    DESTINATION 
    (D_TN)STATION NUMBER OF
    DESTINATION
    (D_STN)
    Max. 5 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7
    TENANT
    NUMBER
    (TN)STATION NUMBER OF CFTB H/L 
    ACCESS CODE
    (ACC)
    Max. 5 digits
    PORTKIND OF STN 
    (TYPE)
    0~2TENANT
    NUMBER OF 
    DESTINATION 
    (D_TN)STATION NUMBER OF
    DESTINATION
    (D_STN)
    Max. 5 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7
    TENANT
    NUMBER
    (TN)STATION NUMBER OF CFTB H/L 
    ACCESS CODE
    (ACC)
    Max. 5 digits
    PORTKIND OF STN 
    (TYPE)
    0~2TENANT
    NUMBER OF 
    DESTINATION 
    (D_TN)STATION NUMBER OF
    DESTINATION
    (D_STN)
    Max. 5 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 90
    Revision 1.0
    AHLGL  : Assignment of CFT Hot Line Group for LDM
    1. GENERAL
    This command is used to assign, delete and display the LDM data which is concerned with PCS Calling
    Conference Group.
    List Up Command: LHLGL
    2. PRECAUTIONS
    1. This command is available for Series 7400 or later software.
    2. This command is used for the Local Node (LN).
    3. “Set” key and “Del” key can be used after UGN and TELN are entered and then this data is read by pressing
    “Get key”.
    If this data is not programmed, press “Get” key again, DA, PORT, TYPE, D_UGN, D_TELN and D_ADC
    can be assigned.
    4. The input parameter depends on TYPE value.
    TYPE=0 or blank : Not displayed
    TYPE=1 : D_UGN, D_TELN
    TYPE=2 : D_ADC
    5. Only Speed Calling Dial Number which is the same tenant as conference leader port can be entered.
    6. The user must assign the data to all ports (PORT 0-7).
    7. If all ports are TYPE=0, this assignment ends in failure.
    8. Data writing to LDM is executed by pressing “Set” key.
    3. DATA ENTRY INSTRUCTIONS
    UGN (USER GROUP NUMBER)
    TELN (CFTB H/L ACCESS CODE  : 0-9, #, * (maximum 16 digits)
    [TELEPHONE NUMBER])
    DA : 0=Stop
    : 1=Continue alerting, when the STN
    does not answer.
    PORT (PORT NUMBER) : 1-7
    TYPE (KIND OF STN) : 0=Vacant Port
    1=STN/PS
    2=OUTSIDE TRUNK (Not used)
    D_UGN (USER GROUP NUMBER OF DESTINATION)
    D_TELN (TELEPHONE NUMBER OF DESTINATION) : 0-9, #, * (maximum 16 digits)
    D_ADC (SPEED CALLING DIAL NUMBER OF DESTINATION): 0-9, #, * (maximum 4 digits) (Not used) 
    						
    							NDA-24301 CHAPTER 5
    Page 291
    Revision 1.0
    4. DATA SHEET
    USER GROUP
    NUMBER
    (UGN)TELEPHONE NUMBER OF CFTB H/L 
    ACCESS CODE
    (TELN)
    Max. 16 digitsRINGING STOP AFTER NO 
    ANSWER TIMER
    (DA) 0/1
    PORTKIND OF STN 
    (TYPE)
    0~2USER GROUP
    NUMBER OF 
    DESTINATION 
    (D_UGN)TELEPHONE NUMBER 
    OF DESTINATION 
    (D_TELN)
    Max. 16 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7
    USER GROUP
    NUMBER
    (UGN)TELEPHONE NUMBER OF CFTB H/L 
    ACCESS CODE
    (TELN)
    Max. 16 digitsRINGING STOP AFTER NO 
    ANSWER TIMER
    (DA) 0/1
    PORTKIND OF STN 
    (TYPE)
    0~2USER GROUP
    NUMBER OF 
    DESTINATION 
    (D_UGN)TELEPHONE NUMBER 
    OF DESTINATION 
    (D_TELN)
    Max. 16 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7
    USER GROUP
    NUMBER
    (UGN)TELEPHONE NUMBER OF CFTB H/L 
    ACCESS CODE
    (TELN)
    Max. 16 digitsRINGING STOP AFTER NO 
    ANSWER TIMER
    (DA) 0/1
    PORTKIND OF STN 
    (TYPE)
    0~2USER GROUP
    NUMBER OF 
    DESTINATION 
    (D_UGN)TELEPHONE NUMBER 
    OF DESTINATION 
    (D_TELN)
    Max. 16 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7 
    						
    							CHAPTER 5 NDA-24301
    Pag e 2 92
    Revision 1.0
    AHLGN  : Assignment of CFT Hot Line Group for NDM
    1. GENERAL
    This command is used to assign, delete and display the NDM data which is concerned with PCS Calling
    Conference Group.
    List Up Command: LHLGL
    2. PRECAUTIONS
    1. This command is available for Series 7400 or later software.
    2. This command is used for the Network Control Node (NCN).
    3. “Set” key and “Del” key can be used after UGN and TELN are entered and then this data is read by pressing
    “Get key”. If this data is not programmed, press “Get” key again, DA, PORT, TYPE, D_UGN, D_TELN
    and D_ADC can be assigned.
    4. The input parameter depends on TYPE value.
    TYPE=0 or blank : Not displayed
    TYPE=1 : UGN, TELN
    TYPE=2 : ADC (Only Speed Calling Dial Number of a node assigned conference leader port can
    be entered.)
    5. Only Speed Calling Dial Number which is the same tenant as conference leader port can entered.
    6. The user must assign the data to all ports (PORT 0-7).
    7. If all ports are TYPE=0, this assignment ends in failure.
    8. Data writing for NDM is executed by pressing “Set” key.
    3. DATA ENTRY INSTRUCTIONS
    UGN (USER GROUP NUMBER)
    TELN (CFTB H/L ACCESS CODE  : 0-9, #, * (maximum 16 digits)
    [TELEPHONE NUMBER])
    DA : 0=Stop
    1=Continue alerting, when the STN
    does not answer.
    PORT (PORT NUMBER) : 1-7
    TYPE (KIND OF STN) 0=Vacant Port
    1=STN/PS
    2=OUTSIDE TRUNK (Not used)
    D_UGN (USER GROUP NUMBER OF DESTINATION)
    D_TELN (TELEPHONE NUMBER OF DESTINATION) : 0-9, #, * (maximum 16 digits)
    D_ADC (SPEED CALLING DIAL NUMBER OF DESTINATION) : 0-9, #, * (maximum 4 digits) 
    (Not used) 
    						
    							NDA-24301 CHAPTER 5
    Page 293
    Revision 1.0
    4. DATA SHEET
    USER GROUP
    NUMBER
    (UGN)TELEPHONE NUMBER OF CFTB H/L 
    ACCESS CODE
    (TELN)
    Max. 16 digitsRINGING STOP AFTER NO 
    ANSWER TIMER
    (DA) 0/1
    PORTKIND OF STN 
    (TYPE)
    0~2USER GROUP
    NUMBER OF 
    DESTINATION 
    (D_UGN)TELEPHONE NUMBER 
    OF DESTINATION 
    (D_TELN)
    Max. 16 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7
    USER GROUP
    NUMBER
    (UGN)TELEPHONE NUMBER OF CFTB H/L 
    ACCESS CODE
    (TELN)
    Max. 16 digitsRINGING STOP AFTER NO 
    ANSWER TIMER
    (DA) 0/1
    PORTKIND OF STN 
    (TYPE)
    0~2USER GROUP
    NUMBER OF 
    DESTINATION 
    (D_UGN)TELEPHONE NUMBER 
    OF DESTINATION 
    (D_TELN)
    Max. 16 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7
    USER GROUP
    NUMBER
    (UGN)TELEPHONE NUMBER OF CFTB H/L 
    ACCESS CODE
    (TELN)
    Max. 16 digitsRINGING STOP AFTER NO 
    ANSWER TIMER
    (DA) 0/1
    PORTKIND OF STN 
    (TYPE)
    0~2USER GROUP
    NUMBER OF 
    DESTINATION 
    (D_UGN)TELEPHONE NUMBER 
    OF DESTINATION 
    (D_TELN)
    Max. 16 digitsSPEED CALLING
    DIAL NUMBER
    (D_ADC)
    Max. 4 digits
    1
    2
    3
    4
    5
    6
    7 
    						
    All NEC manuals Comments (0)